MEAS U5600 Wireless Pressure Transducer FEATURES Heavy Industrial CE Approval 10 V/m EMI Protection Down to 0.1% Pressure Accuracy Down to 0.75% Total Error Band -10C to +60C Compensating Temperature 3C Temperature Output Accuracy -20C to +85C Operating Temperature APPLICATIONS Industrial Process Control and Monitoring Advanced HVAC Systems Refrigeration Systems Automotive Test Stands Off-Road Vehicles Enhanced Pressure Accuracy Digital 24-bit ADC Output, I2C Protocol Bluetooth(R) 4.0 Wireless Connection CE Compliant with a Variety of Pressure Ports Compact and Battery Powered [CR2050 or CR2032] Optional Stainless Steel Snubber Weatherproof (IP66/IP67) FCC Certified Stainless Steel and Polycarbonate Enclosure Gage, Sealed, Absolute, Compound iOS, AndroidTM and Windows(R) XP/7+ Compatible The modular U5600 wireless pressure transducer from our UltraStable line is enclosed in a stainless steel and polycarbonate housing. This high accuracy, 24-bit ADC digital output wireless transducer eliminates hard wiring and provides remote process control and monitoring via Bluetooth(R) 4.0 Wireless Communication. This series is suitable for measurement of liquid or gas pressure, even for difficult media such as contaminated water, steam, and mildly corrosive fluids. The wetted material of the pressure port is made of 316L stainless steel and the transducer's durability is excellent with no O-rings or organics exposed to the pressure media. The U5600 is weatherproof and exceeds the latest heavy industrial CE requirements. This product is geared to the OEM customer for mid to high volumes. TE stands ready to provide a custom design of the U5600 where the volume and application warrants. Additional configurations not listed are available. Please inquire for further information. Pumps and Compressors Hydraulic/Pneumatic Systems Agriculture Equipment Pool/Spa Pump Monitoring Energy Generation and Management TE CONNECTIVITY SENSORS /// U5600 05/2018 Page 1 U5600 Wireless Pressure Transducer STANDARD RANGES Range (psi) Range (Bar) 0 to 005 0 to .35 0 to 015 0 to 001 0 to 030 0 to 002 0 to 050 0 to 3.5 0 to 100 0 to 007 0 to 200 0 to 014 0 to 300 0 to 020 0 to 500 0 to 035 Intermediate ranges available upon request. TE CONNECTIVITY SENSORS /// U5600 Gage Sealed 05/2018 Absolute Compound Page 2 U5600 Wireless Pressure Transducer PERFORMANCE SPECIFICATIONS Ambient Temperature: 25C (unless otherwise specified) For custom configurations, consult factory. Parameters Min Typ Max Units Supply Voltage Accuracy (RSS of linearity, hysteresis, and repeatability) Temperature Output Accuracy 2.3 3 Notes 3.6 VDC Replaceable CR2050 battery -0.25 0.25 %F.S. 5psi -0.1 0.1 %F.S. >5 and 500psi -0.25 0.25 %F.S. >500 and 5000psi -0.75 0.75 %F.S. >5000psi -3 3 C Digital I2C Output Protocol Resolution 24 Bit Endurance 1.00E+6 Stability -0.25 0.25 %F.S./year Total Error Band (@25C over compensated range) -1 1 %F.S. 5psi -0.75 0.75 %F.S. >5 and 5000psi -1.25 1.25 %F.S. >5000psi Proof Pressure 3X 20k psi Rated 0~FS Cycles Burst Pressure 4X 20k psi Rated Long Term Stability (1 year) -0.1 0.1 %F.S. Compensated Temperature -10 +60 C -20 60 C With CR2032 battery -20 +85 C with CR2050 battery -40 +120 C without battery Operating Temperature Storage Temperature Wireless Protocol Receiver Operating System Signal Pairing Distance Signal Transmission Distance Battery Life Low Battery Warning Weatherproof Pressure Port Material Enclosure Shock Vibration Bluetooth(R) 4.0 Wireless Connection or above AndroidTM 4.3 or above, iOS 7 or above, Windows(R) XP/7 or above 65 feet 65 feet affected by receiver antenna and blocking objects 2-years typical CR2050 350mAH battery, 1-year typical CR2032 210mAH battery; 5 second transmission interval 2.5VDC, red battery symbol in app IP66 & IP67 316L Stainless Steel Port, 316L Stainless Steel Snubber Stainless Steel and Polycarbonate 50g, 11msec Half Sine Shock per MIL-STD-202G, Method 213B, Condition A 20g, MIL-STD-810C, Procedure 514.2, Fig 514.2-2, Curve L Note: Battery life depends on its capacity, operating temperature and signal transmission interval. Sony Battery CR2050W or CR2032W offers high operating temperature up to 125C. Temperature can impact battery capacity retention even in idle. Check battery specifications for more details. Factory default data transmission rate is 5sec, which can be adjusted from 100msec to 5sec in smartphone app or PC software. Compliances EN 55022 Emissions Class A & B IEC 61000-4-2 Electrostatic Discharge Immunity (4kV contact/8kV air) IEC 61000-4-3 Radiated, Radio-Frequency Electromagnetic Field Immunity (10V/m, 80M-1GHz); deviation <1.5% RoHS FCC TE CONNECTIVITY SENSORS /// U5600 05/2018 Page 3 U5600 Wireless Pressure Transducer DIMENSIONS Code Port Dim B Typ Dim C Typ Dim D Typ Dim E Typ 2 1/4-19 BSPP 0.547 [13.9] 0.366 [9.3] 0.708 [17.98] 0.075 [1.91] 3 G3/8 JIS B2351 0.615 [15.6] 0.366 [9.3] 0.858 [21.78] 0.075 [1.91] 4 7/16-20UNF MALE SAE J1926-2 STRAIGHT THREAD O-RING BUNA-N 90SH-904 0.508 [12.9] 0.366 [9.3] 0.800 [20.32] 0.075 [1.91] 5 1/4-18 NPT 0.600 [15.24] 0.366 [9.3] N/A N/A 6 1/8-27 NPT 0.390 [9.91] 0.366 [9.3] N/A N/A B G1/4 JIS B2351 0.547 [13.9] 0.366 [9.3] 0.708 [17.98] 0.075 [1.91] E 1/4-19 BSPT 0.500 [12.7] 0.366 [9.3] N/A N/A F 1/4-19 BSPP FEMALE (without snubber) 0.771 [19.58] 0.366 [9.3] N/A N/A P 7/16-20UNF FEMALE SAE J513 STRAIGHT THREAD WITH INTEGRAL VALVE DEPRESSOR 0.647 [16.4] 0.366 [9.3] N/A N/A M10 x 1.0 mm ISO 6149-2 7/16-20UNF FEMALE SAE J513 STRAIGHT THREAD 0.449 [11.4] 0.366 [9.3] 0.543 [13.79] 0.075 [1.91] 0.647 [16.4] 0.366 [9.3] N/A N/A S M12 x 1.5 mm ISO 6149-2 0.531 [13.5 0.366 [9.3] 0.661 [16.79] 0.098 [2.49] U G/14 DIN 3852 FORM E GASKET DIN3869-14 NBR 0.531 [13.5] 0.366 [9.3] 0.744 [18.9] 0.079 [2.01] W M20 x 1.5 mm ISO 6149-2 0.531 [13.5] 0.456 [11.6] N/A N/A G M14 x 1.5 mm ISO 6149-2 0.531 [13.5] 0.366 [9.3] 0.740 [18.8] 0.098 [2.49] Q N HOW TO OPERATE Please refer to the M5600_U5600 Installation Manual and M5600_U5600 Software Manual. Note: Communication is max 65 feet TE CONNECTIVITY SENSORS /// U5600 05/2018 Page 4 U5600 Wireless Pressure Transducer ORDERING INFORMATION U5600 - 0 1 0 0 0 3 - 100P G Cleaning No Selection With Snubber 0 1 0 1 2 Battery Without Battery CR2032 CR2050 0 1 Code 2 3 4 5 6 B E F P N Q S U W G Pressure Reference G Gauge S Sealed A Absolute C Compound Compound Pressure Range is -14.7 to xxxpsig or -1 to xxxbarg (e.g. 200PC: -14.7 to 200psig, 020BC: -1 to 20barg) Label Type Adhesive Label Laser Marking Pressure Range psi bar std std 005P .35B 015P 001B 030P 002B 050P 3.5B 100P 007B 200P 014B 300P 020B 500P 035B Port Type Selection Port Type 1/4"-19 BSPP G3/8 JIS B2351 7/16-20UNF Male SAE J1926-2 Straight Thread O-Ring BUNA-N 90SH-904 1/4-18 NPT 1/8-27 NPT G1/4 JIS B2351 1/4-19 BSPT 1/4-19 BSPP Female* 7/16-20UNF Female SAE J513 Straight Thread w/ Integral Valve Depressor 7/16-20UNF Female SAE J513 Straight Thread M10x1.0mm ISO 6149-2 M12x1.5mm ISO 6149-2 G1/4 DIN 3852 Form E Gasket DIN3869-14 NBR M20x1.5mm ISO 6149-2 M14x1.5mm ISO 6149-2 Intermediate Range between 0.35bar to 35bar available upon request NORTH AMERICA EUROPE ASIA Measurement Specialties, Inc., a TE Connectivity Company Phone: 1 800-522-6752 Email: customercare.frmt@te.com Measurement Specialties (Europe), Ltd., a TE Connectivity Company Phone: +31 73 624 6999 Email: customercare.lcsb@te.com Measurement Specialties (China), Ltd., a TE Connectivity Company Phone: 86 0400-820-6015 Email: customercare.shzn@te.com TE.com/sensorsolutions Measurement Specialties, Inc., a TE Connectivity company. Measurement Specialties, TE Connectivity, TE Connectivity (logo) and EVERY CONNECTION COUNTS are trademarks. All other logos, products and/or company names referred to herein might be trademarks of their respective owners. The information given herein, including drawings, illustrations and schematics which are intended for illustration purposes only, is believed to be reliable. However, TE Connectivity makes no warranties as to its accuracy or completeness and disclaims any liability in connection with its use. TE Connectivity`s obligations shall only be as set forth in TE Connectivity`s Standard Terms and Conditions of Sale for this product and in no case will TE Connectivity be liable for any incidental, indirect or consequential damages arising out of the sale, resale, use or misuse of the product. Users of TE Connectivity products should make their own evaluation to determine the suitability of each such product for the specific application. (c) 2015 TE Connectivity Ltd. family of companies All Rights Reserved. TE CONNECTIVITY SENSORS /// U5600 05/2018 Page 5