88V/A - Automotive Meter Combo Kit
78 and 88V Automotive Meters
Perhaps the most important tool you'll use
in troubleshooting auto electrical systems
is the multimeter. Basic multimeters
measure voltage, current and resistance,
while automotive multimeters like the
Fluke 78 or Fluke 88V have features that
can check things such as frequency,
duty cycle, make diode tests, and
measure temperature, pressure and
vacuum.
Included Accessories
Fluke 88V/A: H80M Holster with TPAK
Meter Hanging Solution, TL224 SureGrip
Silicone Test Lead Set, TP220 SureGrip
Test Probe Set, AC285 SureGrip Large Jaw
Alligator Clip Set, 80BK Integrated
Temperature Probe, RPM80 Inductive Pick-
up Probe, 2 Automotive Back Probe Pins,
Insulation Piercing Clip, C800 Hard Case,
User's Manual + Quick Reference Guide
Fluke 78: C70Y Holster, TL75 Test Lead
Set, AC72 Alligator Clip Set, 80BK
Integrated Temperature Probe, User's
Manual + Quick Reference Guide
Ordering Information
Fluke 88V/A Automotive Meter Combo Kit
Fluke 78 Automotive Meter
Features
Continuity for detecting open and shorts
Frequency for "pulsed-DC" and AC tests
Duty cycle to verify operation of feedback carburetors
Diode test for alternator testing
Built-in thermometer; thermocouple probe included
Min/Max Recording
Min/Max/Average recording with Min/Max Alert
Peak capture to record transients as fast as 250 µs
Relative mode to remove test lead resistance from low ohms
measurements
Millisecond pulse width measurements for fuel injectors
AutoHOLD to capture stable readings
Large display with bright, two-level backlight
Magnet hanger to attach meter to the vehicle
RPM80 Inductive Pickup for both conventional and
distributorless (DIS) ignitions
Hard Meter Case
Safety rating
Fluke 78 Fluke 88V
Range Resolution Accuracy Range Resolution Accuracy
300V 0.1mV 0.3% 1000V 0.01mV 0.1%
300V 1mV 2.5% 1000V (5 kHz) 0.01mV 0.5%
10A1mA 1% 10A 0.01µA 0.4%
10A 10mA 2%10A0.01µA1.2%
40M0.10.5% 400.010.4%
10mF 0.01nF 1%
100kHz 0.01Hz 0.1% 200kHz 0.01Hz 0.01%
1000ºC 1ºC 1% 1090ºC 0.1ºC 1%
Voltage DC
Voltage AC
Current DC
Current AC
Resistance
Capacitance
Frequency
Temperature
Specifications
Battery Life: 88V – Over 400 hours typical
(alkaline)
78 - 2000 hours typical
Weight: 88V – 0.6 kg; 78 – 0.42 kg
Lifetime Warranty
Size (HxWxD): 88V - 200 mm x 95 mm x 48 mm
78 - 190 mm x 89 mm x 45 mm
On all inputs
Fluke 88
Fluke 88V
●●
●●
●●
●●
●●
78 88V/A
optional
Cat II 300 V CAT III 1000V,
CAT IV 600 V
The right meters for auto-electric diagnosis
Fluke 78
Automotive Accessories
TP81 and TP82 Insulation Piercing Clip Set
Banana jack accepts all DMM and banana
jack leads
Non-rotating banana jack prevents leads
from tangling, allowing you to tighten/loosen
clamp while still connected to the test lead
Available for 4 mm input, modular
connection with TP81 or available as a 2 mm
input to slip onto probe tips with the TP82
Tested to 60 V DC
TP84 Oxygen Sensor Insulation Piercing Clip
Banana jack accepts all DMM and
banana jack leads
Non-rotating banana jack prevents
leads from tangling, allowing you to
tighten/loosen clamp while still
connected to the test lead
Tested to 60 V DC
TP88 Rigid Back Probe Pin Set
Slides onto test probes measuring 2 mm
Tested to 60 V DC
Banana jack accepts all DMM and
banana jack leads
Tested to 60 V DC
Kit contains:
TP81 Insulation Piercing Clip Set
TL224 SuregripTM Silicone Test Lead
Set
TP220 SuregripTM Test Probe Set
AC220 SuregripTM Alligator Clip Set
AC285 SuregripTM Large Jaw
Alligator Clip Set
Soft Case
TLK282 SureGrip™ Deluxe Automotive Test Lead Kit
Kit contains:
TP81 Insulation Piercing Clip Set
TP40 Automotive Back Probe Pins (five)
TL224 SuregripTM Silicone Test Lead Set
TP220 SuregripTM Test Probe Set
AC220 SuregripTM Alligator Clip Set
AC285 SuregripTM Large Jaw Alligator
Clip Set
AC280 SuregripTM Hook Clip Set
Soft Case
Current Range: 2 to 600A DC or AC Peak
Basic Accuracy (DC to 400Hz):
+/- (2% of reading + 1A)
Output Signal: 100A range: 10mV/A
600A range: 1mV/A
Frequency Range: 40Hz to 400Hz
Working Voltage: 600V AC rms
Maximum Conductor Diameter: 34 mm
Provides RPM readings
Fluke Corporation
P.O. Box 9090
Everett, WA USA 98206
Fluke Europe B.V.
P.O. Box 1186
5602 BD Eindhoven
The Netherlands
For more information call:
In the U.S.A. (800) 443-5853
or Fax (425) 446 -5116
In Europe/M-East/Africa
+31 (0)40 2 675 200
or Fax +31 (0)40 2 675 222
In Canada (905) 890-7600
or Fax (905) 890-6866
From other countries
+1 (425) 446 -5500
or Fax +1 (425) 446 -5116
Visit us on the world wide web at:
http://www.fluke.com
Fluke (UK) Ltd.
52 Hurricane Way
Norwich
Norfolk
NR6 6JB
United Kingdom
Tel .: 0207 942 0700
Fax: 0207 942 0701
E-mail: industrial@uk.fluke.nl
Fluke. Keeping your world
up and running.
TLK281 SureGrip™ Automotive Test Lead Kit
RPM80 Inductive Pick-up
TP40 Automotive Back Probe Pins (five)
BP880 BNC to Female Double Stacking Banana Plug
BP881 BNC to Male Double Stacking Banana Plug
© Copyright 2004 Fluke Corporation.
All rights reserved.
Printed in the Netherlands 08/04
Data subject to alteration without notice.
Pub_ID: 10761-eng
BP880
Allows for hands-free testing in controlled
voltage environments 500 VRMS maximum
Banana plug is nickel-plated, beryllium
copper for low contact resistance
The BNC shell is plated for tarnish resistance
Operating temperature +50°C maximum
TL28A Automotive Test Lead Set
Flexible silicone insulated leads are heat and
cold resistant
Cat I 30 V, 10 A
90i-610s AC/DC Current Probe (600 A)
Compatible with all Fluke and most popular
DMMs
Digital pressure and vacuum measurements in a
single module
Transducer sealed in 316 stainless steel
compatible with variety of liquids and gases
Measures vacuum to 76 cm Hg
Display results in English (psig or Hg) or metric
(kPa or cm Hg) units
Measures pressure to 500 psig (3447 kPa)
PV350 Pressure Vacuum Module
BP881