ON-BOARD DC-DC CONVERTER ENCAPSULATED MODULES
7.5 WATTS SINGLE & DUAL OUTPUT APS07DM-S & APS07DM-D SERIES
Advanced Power Solutions
FEATURES:
¢ VERY LOW PROFILE 7.0 MM HIGH
¢ SINGLE & DUAL OUTPUT
¢ WIDE 4:1 INPUT RANGE
¢ 7.5W ISOLATED OUTPUT
¢ SIX-SIDED METAL SHIELD
OUTPUT SPECIFICATION
Output Voltage: See Ratings Chart
Output Current: See Ratings Chart
Voltage Accuracy: Main O/P ±2.0% typ.
Line Regulation: ±0.5% typ.
Load Regulation: Single O/P ±1.0% typ.
Dual O/P ±2.0% typ.
Noise & Ripple: Typ. 100mV for 3.3V/5.0V &
1.0% for others peak to peak
OVP: Built-in on main output
Adjustability: Not available
Short Circuit Protection: Power fold back,
Self-recovering
Overload Protection: About 130% of overrange
foldback type
SPECIFICATION
INPUT SPECIFICATION
Input Range: Wide 4:1 DC input range
See Ratings Chart
Input Voltage: Nominal 12/24/48Vdc
Input Current: Various with input range and load
See Ratings Chart
Input Fuse: Use external fuse
Input Filter: Pi-Network
Undervoltage Shutdown: 8Vdc
Isolation Resistor: 1,000 Mega Ohms
Isolation Voltage: 1,500Vdc
EMI: Six-sided metal shielding
Remote On/Off: TTL/CMOS-Compatible Input Control
Logic input reference to –Input/-Vin
Logic [1]/Open(or 2.5-7.0Vdc above -Vin)=ON
Logic [2]/Short(or 0-0.08Vdc above -Vin)=OFF
GENERAL SPECIFICATION
Efficiency: Typ.81%, various with input.
Switching Frequency: Fixed frequency 450K Hz.
Circuit Topology: 450K Hz. Forward Circuit.
Transient Response: Full to 1/2 load <200 uSec.
Case: Black coated aluminum with non-conductive
metal base.
Weight: 20.0g (0.71 Oz.).
Power Density: 12.0Watts./ Cubic inch.
Operating Temperature: -40°C to +85°C range. –25°C to
+71°C @ full load without derating. Derating linearly
3.5%/ °C from +71°C @ full load to +85°C @ half-load.
Storage Temperature: -55°C to +110°C.
Humidity: Up to 95% RH, Non-condensing.
Temperature Coefficient: 0.02% /°C.
Cooling: Convection cooling up to 60°C @F-L. At least
100LFM moving air is recommended for F-L >+60°C in
a confined area.
Commercial Grade: Full load up to +71°C with moving air.
Industrial Grade: +71 to +85°C F-L to H-L with moving air.
NOTE:(1) All measurements are at nominal input, full load and +25°C unless otherwise specified.
(2) Line Regulation measured from High to Low Lines at full load.
(3) Load Regulation measured from Full Load (F-L) to Half-Load (H-L) at nominal input.
(4) Correct fuse size by calculating the max. DC current drain at low Line input & Load and then adding 20-25% for the desired fuse size.