Product Specification
XL125/160DC Series
125/160
Power Supplies
Document No.
Product Specification
XL125/160DC Series
125/160
-Watt DC to DC
Power Supplies
Document No.
703152 Rev 07-01-19
XL125/160DC Series
703152 Rev 07-01-19
i
Notices
N2Power is a wholly owned subsidiary of Qualstar Corporation.
N2Power and the N2Power logo are registered trademarks of Qualstar Corporation.
Copyright
©
2009-2019 by Qualstar Corporation — All Rights Reserved
Information contained in this document is copyrighted by Qualstar Corporation and is
intended for use by customers and prospective customers to evaluate and integrate our
power supplies. Customers and prospective customers may reproduce this document as
needed for these purposes. Reproduction in whole or in part for any other purpose or by
any other party is prohibited without prior written permission from Qualstar
Corporation.
Every effort has been made to keep the information contained in this document current
and accurate as of the date of publication or revision. However, no guarantee is given or
implied that the document is error-free or that it is accurate with regard to any
specification.
N2Power reserves the right to modify the design or specification without notice. This
specification may not be construed as a contractual obligation except as specifically
agreed to by N2Power in writing at the time of order.
For warranty information refer to www.n2power.com
For information about this product specification, please write or call N2Power at:
N2Power
1267 Flynn Road
Camarillo, CA 93012
Fax: (805) 978-5212
Phone: (805) 583-7744
E-Mail: sales@n2power.com
www.n2power.com
703152 Rev 07-01-19
ii
Table of Contents
1. Introduction .............................................................................................................................. 1-1
1.1 Introduction ............................................................................................................................................1-1
1.2 Safety Warning .......................................................................................................................................1-2
1.3 Agency Compliance ..............................................................................................................................1-2
2. DC Input ...................................................................................................................................... 2-1
2.1 Input Requirements .............................................................................................................................2-1
2.2 Input Characteristics ...........................................................................................................................2-1
2.3 Input Isolation ........................................................................................................................................2-1
3. DC Outputs ................................................................................................................................. 3-1
3.1 Output Voltage Regulation ................................................................................................................3-1
3.2 No Load Operation ...............................................................................................................................3-2
3.3 Output Loading for Models XL125/160-1DC and XL125/160-8DC ....................................3-2
3.4 Output Loading for Single-Output Models ..................................................................................3-3
3.5 Cooling .......................................................................................................................................................3-3
3.6 Output Ripple/Noise ...........................................................................................................................3-4
3.7 Local and Remote Sensing .................................................................................................................3-6
3.8 Parallel Operation: XL125/160-05DC CS thru XL125/160-56DC CS ..............................3-7
3.9 Output Protection .................................................................................................................................3-8
3.10 Output Rise Time .............................................................................................................................3-9
3.11 Overshoot At Turn On/Turn Off ................................................................................................3-9
3.12 Output Transients ...........................................................................................................................3-9
3.13 Closed Loop Stability ................................................................................................................... 3-10
3.14 Capacitive Loading ....................................................................................................................... 3-10
4. General Specifications ........................................................................................................... 4-1
4.1 Environmental .......................................................................................................................................4-1
4.2 Mean Time Between Failures ..........................................................................................................4-1
4.3 Component Stress .................................................................................................................................4-1
4.4 Labeling/Marking .................................................................................................................................4-2
4.5 Weight .......................................................................................................................................................4-2
4.6 Mounting ..................................................................................................................................................4-2
4.7 Physical Dimensions ............................................................................................................................4-3
4.8 Mating Connectors ...............................................................................................................................4-3
4.9 Output Grounding .................................................................................................................................4-5
4.10 Signal Pin Definitions .....................................................................................................................4-6
703152 Rev 07-01-19
iii
5. Efficiency .................................................................................................................................... 5-1
5.1 XL125-1, -8DC Efficiency ...................................................................................................................5-1
5.2 XL125-05DC Efficiency .......................................................................................................................5-3
5.3 XL125-12…56DC Efficiency ..............................................................................................................5-4
5.4 XL160-1, -8DC Efficiency ...................................................................................................................5-9
5.5 XL160-05DC Efficiency .................................................................................................................... 5-11
5.6 XL160-12…56DC Efficiency ........................................................................................................... 5-12
6. Timing and Control ................................................................................................................. 6-1
6.1 Power Supply Timing ..........................................................................................................................6-1
6.2 Power Good Signal/PS_OK Signal/Remote ON Input ............................................................6-1
6.3 Power Good LED ...................................................................................................................................6-2
6.4 Power Sequencing: XL125/160-1DC and XL125/160-8DC ................................................6-2
7. Ordering Information ............................................................................................................ 7-1
703152 Rev 07-01-19
Introduction 1-1
1. Introduction
1.1 Introduction
This specification defines the design and performance characteristics of the
XL125/160DC-Series of open frame DC-input power supplies. These supplies provide
single or multiple regulated DC outputs that are electrically isolated from the nominal
48VDC-input. All models are available in either 125-watt or 160-watt output power
ratings. Single output models also have isolated 12V @ 1A auxiliary outputs and can be
connected as plus or minus voltages. The 54V and 56V models have additional output
insulation to meet the NEBS 1500VDC output isolation to chassis requirement.
The XL125/160DC-Series have similar output characteristics to N2Power’s AC-input XL-
Series but are distinguished from each other by the heat sink/cover color: black for AC-
input models and aluminum (clear anodized) for DC-input models.
Figure 1-1 XL125/160DC (models differ slightly)
703152 Rev 07-01-19
1.2
Safety Warning
This product
is a component, not a stand
mounted inside a protective enclosure to prevent accidental shock by contact
with the supply. Lethal voltages are present while and after power is applied
Allow 1-
minute for storage capacitors to
handling the
power supply
The safety ground connection is
be securely
connected to Protective Earth.
1.3
Agency Compliance
Safety
Complies with Standard
United States UL 60950-
1 (2007) Second Edition
UL 62368-
1 Second Edition
(Information Technology Equipment)
Canada
CSA 22.2: 60950
EU Council 2006/95/EC
International IEC 60950-
1 (2005) Second Edition
IEC 62368-
1 (2014) Second Edition
EMC
Complies with Standard
United States
FCC part 15, subpart B
EU Council 2004/108/EC
International EN 61204-
3 (refers to the following)
EN 55022 Class B
EN 55024 (refers to the following)
EN 61000
EN 61000
EN 61000
EN 61000
EN 61000
Reduction of Hazardous Substances (RoHS)
EU Council
Marks of Conformance
United States & Canada
Europe
EU Council
RoHS
XL125/160DC Series Product Specification
Introduction
Safety Warning
WARNING
is a component, not a stand
-
alone power supply. It must be
mounted inside a protective enclosure to prevent accidental shock by contact
with the supply. Lethal voltages are present while and after power is applied
minute for storage capacitors to
discharge after removing power before
power supply
.
The safety ground connection is
made via one of the
four mounting holes.
connected to Protective Earth.
See Figure 4-2.
Agency Compliance
Complies with Standard
Remarks
1 (2007) Second Edition
1 Second Edition
(Information Technology Equipment)
Leakage Current
Hi-pot –
2121vdc for 1 second
CSA 22.2: 60950
-1
Low Voltage Directive
1 (2005) Second Edition
1 (2014) Second Edition
Complies with Standard
Remarks
FCC part 15, subpart B
Conducted emissions
Limits per CISPR 22 Class B
Tested to ANSI C63.4: 2003
EMC Directive
3 (refers to the following)
Low Voltage Power Supplies
EN 55022 Class B
Conducted emissions
Limits per CISPR 22 Class B
EN 55024 (refers to the following)
Immunity
EN 61000
-4-3
Radiated Susceptibility
EN 61000
-4-4
Fast Transient/Burst Immunity
EN 61000
-4-5
Power Mains Surge Immunity
EN 61000
-4-6 RF Immunity
EN 61000
-4-11
Voltage Dips, Short Interruptions
Reduction of Hazardous Substances (RoHS)
Complies with Standard
2002/95/EC
(Underwriters Laboratories File E211115)
Table 1-1 Agency Compliance
10
XL125/160DC Series Product Specification
1-2
alone power supply. It must be
mounted inside a protective enclosure to prevent accidental shock by contact
with the supply. Lethal voltages are present while and after power is applied
.
discharge after removing power before
four mounting holes.
It must
– DC Output
Remarks
RoHS Directive
703152 Rev 07-01-19
DC Input 2-1
2. DC Input
2.1 Input Requirements
The following table defines the DC input power requirements for the XL125/160DC-
Series, which are capable of supplying full rated power in continuous operation
throughout the specified ranges of input voltages. The power supplies will automatically
recover from DC power loss and are capable of starting under maximum load at the
minimum DC input voltage described below.
Parameter Minimum Nominal Maximum
Input Voltage 36 VDC 48 VDC 76 VDC
XL125-05DC 4.6 A @ 36 V 3.4 A @ 48 V 2.1 A @ 76 V
Other XL125DC Models 4.1 A @ 36 V 3.1 A @ 48 V 1.9 A @ 76 V
XL160-05DC 6.2 A @ 36 V 4.6 A @ 48 V 2.8 A @ 76 V
Other XL160DC Models 5.4 A @ 36 V 4.0 A @ 48 V 2.5 A @ 76 V
Table 2-1 DC Input Requirements at Full-Load (approximate)
2.2 Input Characteristics
Power-on inrush current is primarily a function of the power supply’s input capacitance
and the risetime of the input voltage. The XL125/160DC-Series presents an input
capacitance of approximately 13uF (37mJ at 76VDC in). Additional passive resistance
and inductance further limit the inrush current when power is applied.
For safety protection, 8-amp input fuses are provided on both the plus and minus inputs
in case of excessive input voltage or an internal failure. These fuses are not user
replaceable.
Repetitive ON/OFF cycling of the DC input voltage within the specified values shall not
damage the power supply or cause the input fuses to fail.
The application of an input voltage below the minimums specified in Table 2-1, or of
reversed polarity (below the rated maximum) shall not cause damage. The supply will
not turn-on in either case, but will recover when the proper input voltage is applied.
2.3 Input Isolation
The input is electrically isolated from the output and chassis terminals with an isolation
resistance in excess of 10-megaohms. To minimize conducted noise, capacitors are
provided between the chassis mounting holes and the input and output terminals. There
is approximately 1.7-microfarads between the input terminals and the chassis, and 0.1-
microfarads between the output terminals and the chassis.
703152 Rev 07-01-19
DC Outputs 3-1
3. DC Outputs
3.1 Output Voltage Regulation
The DC output voltages shall remain within the Minimum and Maximum limits of Table
3-1 when measured at the power supply connector under all specified line, load and
environmental conditions contained herein (V1 can maintain these tolerances at the load
when 2-wire remote sense is implemented). The 12-volt auxiliary outputs float on models
XL125/160-12DC through XL125/160-56DC. Thus, they can be used as either a positive
or negative supply. On the XL125/160-05DC models the output returns of V1 and the 12V
auxiliary output are tied together.
XL125:
XL160:
Output Rated
Voltage
Regulation Minimum
(VDC)
Nominal
(VDC)
Maximum
(VDC)
Remote
Sense
-1DC
V1 +3.3 ±3% 3.201 3.300 3.399 V1/RTN
V2 +5 ±4% 4.848 5.050 5.252 V2
V3 +12 ±5% 11.400 12.000 12.600 -
V4 -12 ±5% -11.400 -12.000 -12.600 -
-8DC
V1 none - - - - -
V2 +5 ±4% 4.848 5.050 5.252 RTN only
V3 +12 ±5% 11.400 12.000 12.600 -
V4 -12 ±5% -11.400 -12.000 -12.600 -
-05DC V1 +5 ±3% 4.850 5.000 5.150 V1/RTN
V2 +12V
aux
±5% 11.400 12.000 12.600 -
-12DC V1 12 ±3% 11.640 12.000 12.360 V1/RTN
V2 +/-12V
aux
±5% 11.400 12.000 12.600 -
-15DC V1 15 ±3% 14.550 15.000 15.450 V1/RTN
V2 +/-12V
aux
±5% 11.400 12.000 12.600 -
-24DC V1 24 ±3% 23.280 24.000 24.720 V1/RTN
V2 +/-12V
aux
±5% 11.400 12.000 12.600 -
-48DC V1 48 ±3% 46.560 48.000 49.440 V1/RTN
V2 +/-12V
aux
±5% 11.400 12.000 12.600 -
-54DC V1 54 ±3% 52.380 54.000 55.620 V1/RTN
V2 +/-12V
aux
±5% 11.400 12.000 12.600 -
-56DC V1 56 ±3% 54.320 56.000 57.680 V1/RTN
V2 +/-12V
aux
±5% 11.400 12.000 12.600 -
Table 3-1 XL125/160DC Output Voltage Specifications
XL125/160DC Series Product Specification
703152 Rev 07-01-19
DC Outputs 3-2
3.2 No Load Operation
The power supply will operate with reduced output voltage regulation of +/-10% with all
outputs unloaded. This no load condition will not damage the power supply or cause a
hazardous condition, however the Power Good signal may not go true with less than a 5-
watt load. The power supply will remain stable and operate normally after application of
loads.
CAUTION
Remove DC power prior to installing or removing secondary loads.
3.3 Output Loading for Models XL125/160-1DC and XL125/160-8DC
The combined power of all outputs must not exceed the total power figures listed in
Table 3-5. Additionally, the combined output power of V1 and V2 must not exceed the
values listed in Table 3-3.
Output Rated
Voltage
Minimum
Load
XL125
Maximum
Load
XL125
Maximum
Watts/Output
XL160
Maximum
Load
XL160
Maximum
Watts/Output
V1 +3.3 V 0.0 A 10.0 A 33 15.0 A 50
V2 +5 V 1.0 A 15.0 A 75 20.0 A 100
V3 +12 V 0.0 A 5.0 A 60 6.0 A 72
V4 -12 V 0.0 A 1.0 A 12 1.0 A 12
Table 3-2 XL125/160-1DC and -8DC Min/Max Load Currents
V1+V2 Power
Restrictions
Forced
CFM
Forced
@ 50°C
Forced
@ 70°C
Convection
@ 50°C
XL125-1DC 5 CFM 80-watts 40-watts 75-watts
XL160-1DC 10 CFM 100-watts 50-watts 75-watts
Table 3-3 Maximum Continuous Combined V1+V2 Output Power vs. Available Cooling
XL125/160DC Series Product Specification
703152 Rev 07-01-19
DC Outputs 3-3
3.4 Output Loading for Single-Output Models
These single-output models all have an auxiliary 12V output (V2, 12V AUX) that is
typically used to drive a cooling fan. The load on this V2 output can vary from 0 to 1.0
amp and does not affect the Power Good or PS_OK signals. Its output power detracts from
that otherwise available to the V1 load. The maximum load currents listed in Table 3-4
assume V2 is unloaded. The V2 supply floats on these models. The combined power of all
outputs must not exceed the total power figures listed in Table 3-5.
XL125:
XL160:
Rated V1
Output
Power Good
Load
XL125
Maximum
Load
XL160
Maximum
Load
-05DC 5 V 1.00 A 25.0 A 32.0 A
-12DC 12 V 0.40 A 10.4 A 13.3 A
-15DC 15 V 0.33 A 8.3 A 10.7 A
-24DC 24 V 0.20 A 5.2 A 6.7 A
-48DC 48 V 0.09 A 2.6 A 3.3 A
-54DC 54 V 0.09 A 2.3 A 3.0 A
-56DC 56 V 0.09 A 2.2 A 2.9 A
Minimum load needed for the Power Good signal to go high and the
PS_OK signals to go low.
Assuming no load on the V2 output.
Table 3-4 Min/Max Load Currents for single-output models
3.5 Cooling
The maximum continuous output power is always a function of the cooling airflow and
ambient temperature. The maximum output power is attainable with the listed Forced
CFM (cubic feet per minute) of air flow at a temperature of 50°C or less. The airflow may
be co-planar with the circuit board or impinge down on the top of the heat sink/cover.
See Section 3.5.1 for derating output power above 50°C. The total available output power
is reduced considerably with unrestricted convection cooling. Unrestricted means there
are no nearby obstructions that would impede the convection cooling process.
Model Forced
CFM
Forced
@ 50°C
Forced
@ 70°C
Convection
@ 50°C
XL125 5 CFM 125-watts 62.5-watts 85-watts
XL160 10 CFM 160-watts 80-watts 85-watts
Table 3-5 Maximum Continuous Total Output Power vs. Available Cooling
XL125/160DC Series Product Specification
703152 Rev 07-01-19
DC Outputs 3-4
3.5.1 High Temperature Derating
The XL125/160DC can be operated at elevated temperatures by derating the total
maximum output power (or current) by 2.5%/C from 50C to 70C (see Figure 3-1).
-25 0 25 50 70
Degrees C
0
50
100
% Load
Figure 3-1 Derating Curve for Elevated Temperature Operation
3.6 Output Ripple/Noise
Output ripple voltage and noise are defined as periodic or random signals over a
frequency band of 10 Hz to 20 MHz. Measurements are to be made with an oscilloscope
with at least 20 MHz bandwidth. Outputs should be bypassed at the connector with a 0.1
F ceramic disk capacitor and a 10 F tantalum capacitor to simulate system loading (see
Figure 3-2). Ripple and noise shall not exceed the limits specified in the following tables.
3.6.1 Ripple and Noise
The ripple voltage of the outputs is measured at the pins of the mating connector. Ripple
and noise shall not exceed the limits specified in Table 3-6 under any condition of line
voltage and frequency specified in Section 2.1 and DC loading specified in Section 3.3.
XL125/160DC Series Product Specification
703152 Rev 07-01-19
DC Outputs 3-5
XL125:
XL160:
Output Voltage Maximum
Ripple+Noise
(peak-to-peak)
-1DC, -8DC
V1 +3.3 V 50 mV
V2 +5 V 50 mV
V3 +12 V 120 mV
V4 -12 V 120 mV
-05DC
through
-56DC
V1 5 V 50 mV
V1 12 V 120 mV
V1 15 V 150 mV
V1 24 V 240 mV
V1 48 V 480 mV
V1 54 V 540 mV
V1 56 V 560 mV
V2 12 V 120 mV
Table 3-6 Maximum Ripple+Noise (P-P)
3.6.2 Ripple/Noise Test Setup
Figure 3-2 Ripple Noise Measurement Setup
Power Supply
DC+
DC-
V Out
DC Return
Earth Ground
Load
Load must be
isolated from the
earth ground of
the power supply.
Differential
Oscilloscope
10uf 0.1uf
Notes:
1. Load the output with its minimal
load current.
2. Connect the probes as shown but
keep them as close as possible to
the J2 (output) connector.
3. Repeat the measurement with
maximum load on the output.
XL125/160DC Series Product Specification
703152 Rev 07-01-19
DC Outputs 3-6
3.7 Local and Remote Sensing
Remote sensing is provided to compensate for voltage drops in the V1 (+ Output) and DC
RETURN connections to the load. For every model, the 0V Sense input must be connected
to either one of the DC Return pins of the supply or the DC Return terminal at the load.
This is necessary for the power supply to guarantee it will meet specification. Connecting
it to the return side of the load will reduce the voltage drop in the external return wiring.
If the V1 Sense input is left open, the V1 output will raise slightly (approximately 0.3V)
above its load regulation specification. The V1 output will meet its load regulation
specification when the V1 Sense pin is connected to one of the V1 output pins. Connecting
the V1 Sense pin to the V1 output at the load will reduce the voltage drop in the external
V1 wiring.
3.7.1 Local and Remote Sensing: XL125/160-1DC, XL125/160-8DC
The V1 Sense input need not be connected for the X125/160-8, as it has no V1 output.
The XL125/160-1DC can compensate for up to 0.2V drop in each side (+Output and
RETURN). Figure 3-3 shows the required and optional remote sensing connections. Refer
to Table 4-7 for the pin definition of the XL125/160 connectors.
Single pin J4 should be connected to the V2 (+5V) load to improve regulation at the load.
Local V1 Sense
Load
V1 +Output
DC RETURN
1
2
3
J3
1
2
3
J3
Remote V1 Sense
V1 +Output
DC RETURN
Load
Figure 3-3 Remote V1 Sensing: XL125/160-1DC and XL125/160-8DC
3.7.2 Local and Remote Sensing: XL125/XL160-05DC [CS]
Up to 0.2V in the return and 0.2V in the V1 connection may be compensated.
Figure
3-4
shows the required and optional remote sensing connections. J3 actually has five pins but
only the first three are shown below. Refer to Table 4-7 for the pin definition of the XL160
connectors.
The CS models contain an internal OR-ing diode (MOSFET) so that V1 output of multiple
power supplies may be connected in parallel. Follow the same sense wiring for each
paralleled supply as if it were a single supply.
XL125/160DC Series Product Specification
703152 Rev 07-01-19
DC Outputs 3-7
Figure 3-4 Remote Sensing Wiring: XL125/XL160-05DC [CS]
3.7.3 Local and Remote Sensing: XL125/160-12DC [CS] through XL125/160-
56DC [CS]
Up to 0.5V in the return and 0.5V in the V1 connection may be compensated. Figure 3-5
shows the required and optional remote sensing connections. J3 actually has five pins but
only the first three are shown below. Refer to Figure 4-3 for the pin definition of the
connectors.
These models contain internal OR-ing diodes so that V1 output of multiple power
supplies may be connected in parallel. Follow the same sense wiring for each paralleled
supply as if it were a single supply.
Figure 3-5 Remote Sensing Wiring: XL125/160-12DC through XL125/160-56DC
3.8 Parallel Operation: XL125/160-05DC CS thru XL125/160-56DC CS
Two, three or four power supplies may be connected in parallel to provide higher output
power. They can also be used in a N+1 configuration to provide higher output power and
greater reliability. Each of these models has a built-in output OR-ing diode (or MOSFET)
and a Current Share signal for parallel operation.
3.8.1 Current Sharing Connections
The Current Share signal (see Table 4-7) of each supply operating in parallel must be
connected together. Power sharing does not require the 0V Sense signals be connected
together, but the sharing accuracy may not meet published specification unless they are
also connected together.
Local V1 Sense
Load
V1 +Output
DC RETURN
1
2
3
J3
1
2
3
J3
Remote V1 Sense
V1 +Output
DC RETURN
Load
Local V1 Sense
Load
V1 +Output
DC RETURN
1
2
3
J3
1
2
3
J3
Remote V1 Sense
V1 +Output
DC RETURN
Load
XL125/160DC Series Product Specification
703152 Rev 07-01-19
DC Outputs 3-8
Power Good signals may be wire OR-ed together, but this is not recommended, as a failing
power supply will pull the signal low. They should be monitored individually by the
user’s system.
3.8.2 Current Share Accuracy
When all the current share signals are connected together and all the 0V Sense signals are
connected together, the load delivered by any two supplies of the sharing supplies will
not vary by more than 10% at full load.
3.8.3 Transients
The output rise time and monotonic requirements of Section 6.3 may not be met where
the load exceeds 125/160 watts, because of the difference in start-up times of the
paralleled power supplies.
When the input power to one of the parallel power supplies is disconnected or
reconnected, or a power supply fails, the transient on the V1 output is within five (5)
percent of nominal output voltage, although the output voltage may ramp to a new
nominal voltage within the regulation band.
3.9 Output Protection
There are three different output protection schemes designed to protect the load and the
supply from component failures and extraordinary circumstances.
3.9.1 Over Temperature Protection
If the supply is operated without adequate cooling, it will sense an over-temperature
condition and shut itself down. It will automatically restart when it has cooled down to
below its maximum operating temperature.
3.9.2 Over Voltage Protection
No single fault is able to cause a sustained over voltage condition on any main output.
When an over-voltage condition occurs, the power supply will shut down and then
periodically attempt to restart. The supply will shut down under the following over
voltage conditions:
Output Minimum Nominal Maximum
3.3 V 3.76 V 4.2 V 4.8 V
5.0 V 5.74 V 6.3 V 7.0 V
12.0 V 13.5 V 15.0 V 16.5 V
15.0 V 16.87 V 18.75 V 20.6 V
24.0 V 27.0 V 30.0 V 33.0 V
48.0 V 54.0 V 58.0 V 64.0 V
54.0 V 60.8V 64.8V 74.3V
56.0 V 63.0V 70.0V 77.0V
Table 3-7 Over Voltage Protection Limits
XL125/160DC Series Product Specification
703152 Rev 07-01-19
DC Outputs 3-9
3.9.3 Over Current Protection
Overload currents applied to any output will cause the output to shut down. The power
supply will periodically attempt to restart until the over-current condition is removed.
This feature is tested with an ever-increasing load at a rate of 10 A/second starting at
maximum load.
Pulsating loads of 150% of the rated output can be sustained for 10-milliseconds
provided the duty cycle does not exceed 10%. The total RMS power must still be limited
to 125/160-watts.
3.9.4 Short Circuit Protection
A short circuit is defined as an impedance of less than 0.1 ohms placed between DC
RETURN and any output. A short circuit will cause no damage to the power supply and
will cause it to shutdown. The power supply will periodically attempt to restart until the
short circuit condition is removed. After successfully restarting, the power supply will
operate normally.
A short circuit on the 12Vaux/-12V output will not cause the power supply to shut down
and the output will resume normal operation when the short circuit is removed.
3.10 Output Rise Time
All output voltages shall rise from 10% to 90% of nominal output voltage (as
specified in Table 3-1) within 0.2ms to 20ms. The output voltages waveform must be
a monotonic ramp from 10% to 90% of final set-point within the regulation band
under any loading conditions specified in the respective load current tables in
Section 6.
For the purposes of this specification, a monotonic ramp is defined as always having
a positive slope of from zero to 10*Vout volts/millisecond. During any 5-millisecond
portion of the ramp, its slope must greater than 5% of its rated voltage per
millisecond.
3.11 Overshoot At Turn On/Turn Off
The output voltage overshoot upon the application or removal of the input mains
voltage is less than 10% above the nominal voltage. No opposite polarity voltage is
present on any output during turn-on or turn-off.
3.12 Output Transients
The maximum output voltage transient caused by step load changes will not exceed
the output voltage regulation limits by more than 5%. With a DC input as specified in
Section 2.1, the power supply will remain stable when subjected to the load
transients described below:
Load changes between 75% and 100% on any output
Load changing repetition of 50 to 333 cycles per second
XL125/160DC Series Product Specification
703152 Rev 07-01-19
DC Outputs 3-10
Transient load slew rate = 1.0 A/microsecond
Capacitive loading per Table 3-8
3.13 Closed Loop Stability
The power supply is unconditionally stable under all line/load/transient load conditions
including the capacitive loads specified in Table 3-8. The power supply shall exhibit a
minimum of 45-degrees phase margin and 6 dB gain margin.
3.14 Capacitive Loading
The power supply will power up and operate normally with the capacitances listed in
Table 3-8 simultaneously present on the outputs. Other values may also provide
consistently normal operation but must be tested by the user.
Models -1DC & -8DC -05DC -12DC -15DC -24DC -48DC -54DC -56DC
+3.3 V 6,000 μF
+5 V 10,000 μF
+12 V 1,000 μF
-12 V
aux
350 μF 350 μF 350 μF 350 μF 350 μF 350 μF 350 μF 350 μF
V1 10,000 μF 3,000 μF 3,000 μF 2,000 μF 500 μF 500 μF 500 μF
Table 3-8 XL125/160DC Capacitive Loading
703152 Rev 07-01-19
General Specifications 4-1
4. General Specifications
4.1 Environmental
The XL125/160DC meets or exceeds the following environmental specifications:
Parameter Conditions Specification Remarks
Temperature Operating -25°C to 50°C See cooling requirements
Non-Operating -40°C to 85°C
Relative Humidity Operating 95% Maximum Non-Condensing
Non-Operating 95% Maximum Non-Condensing
Altitude Operating 6,561 feet MSL Max. 2,000 meters
Non-Operating 50,000 feet MSL Max. 15,240 meters
Vibration No damage 2.4G RMS Maximum 5-500Hz, 10-min. each axis per
MIL-PRF-28800F: 3.8.4.1 (Class 3,4)
6.0G RMS Maximum 100-1,000Hz random, 10-min.
vertical axis only
Mechanical Shock No damage 30G half-sine, 11mS Six shocks each axis per
MIL-PRF-28800F: 4.5.5.4.1
Table 4-1 Environmental Specifications
4.2 Mean Time Between Failures
The calculated MTBF of all models except the XL125/160-1,-8DC is equal to or greater
than 200,000 hours of continuous operation at maximum output loading and worst case
input line voltage with forced-air cooling at 25°C. The XL125/160-1,-8DC is rated at
233,000 hours. N2Power does not warrant the MTBF to be representative of any
particular unit. The MTBF of the power supply is calculated with an 80% confidence
level in accordance with Telcordia SR-332, Issue 2 at 25°C. Actual failure rates vary from
unit to unit.
4.3 Component Stress
The XL125/160DC design followed these component-derating guidelines:
semiconductor junction temperatures shall not exceed ninety (90) percent of
manufacturer’s rating with an ambient of 50C. Inductor winding temperatures shall not
exceed safety agency requirements. Capacitor case temperatures shall not exceed 95%
of rated temperature. Resistor power dissipation derating is greater than 30%.
Component voltage and current derating is greater than 10% at 50C.
XL125/160DC Series Product Specification
703152 Rev 07-01-19
General Specifications 4-2
4.4 Labeling/Marking
The power supply is marked and labeled with the N2Power logo and part number,
model number, input and output specifications, production code, appropriate safety
agency logos, CE mark, and country of origin. A typical label is pictured below.
Figure 4-1 Sample Label
4.5 Weight
XL125/XL160-1DC, -8DC XL125/XL160-05…56DC
Pounds 0.71 0.63
Ounces 11.3 10.0
Kilograms 0.32 0.29
Table 4-2 Net Weight
4.6 Mounting
The supply may be mounted in any attitude but must be mounted on all four corners. No.
6 or M3 mounting hardware should not exceed .282-inches (7.16-mm) in diameter for
any lockwasher, flat washer, standoff, screw head or other mounting hardware to avoid
contact and maintain adequate safety agency spacing requirements with components or
printed circuit board traces. The XL125/160DC requires a safety earth connection at the
mounting hole nearest J1 (See Figure 4-2). If the standoff is shorter than .250” (6.35mm)
an insulator is recommended between the PCBA and chassis.
XL125/160DC Series Product Specification
703152 Rev 07-01-19
General Specifications 4-3
4.7 Physical Dimensions
Figure 4-2 XL125/160DC Dimensions (XL125-8DC shown in example)
4.8 Mating Connectors
The user must furnish all mating connectors. The mating connectors must meet the
requirements of all applicable safety agencies (notably UL). Molex (Molex is a
trademark of the Molex Corporation) did not change their part numbers when they took
the lead out of their contacts. The Molex part numbers in this section should yield RoHS
compliant contacts. The largest wire size accepted by each contact should be used for all
power connections to help dissipate the heat generated by the resistive connections.
Note that the female contacts that mate to the power supply are only rated for 25-30
mating cycles. Excessive mating cycles causes dramatically increased terminal resistance
3.00 ±.03
[76.2]
Ø.156 ±.003 (4 places)
[4.0]
1.32 MAX
[33.58]
Note: Recommended standoff size is .375” high and all mounting hardware should
be less than .28” in diameter. A standoff less than .375” high is acceptable when a
thin insulator, 0.4mm thick (polyester, fish paper or equivalent UL rated 94V-2
minimum) is placed between the power supply and the mounting chassis (refer to
applicable UL standard for clearance requirements).
+
-
5.00 ±.03
[127.0]
.225 ±.010
[5.7]
2.55 ±.005
[64.8]
Pin 1
J1
Safety ground connection point
4.55 ±.005
[115.6]
1.00 REF
[25.4]
Dimensions in inches [mm]
1.12 MAX
[28.50]
.06
[1.6] .20 MAX
[5.08]
XL125/160DC Series Product Specification
703152 Rev 07-01-19
General Specifications 4-4
and heating resulting in the eventual failure of the mating terminal and possibly the
header on the power supply.
CAUTION
The pin-1 location differs amongst connector manufacturers. Sometimes pin-1
differs between the header (on the power supply) and the mating housing from
the same manufacturer. Disregard the manufacturer’s pin-1 location and follow
only the pin-1 locations in Figure 4-3.
4.8.1 DC Input Mating Connector (J1)
The DC input connector is a 3-pin Molex KK-156 style header with 0.156” centers. The
center pin is omitted. The Molex part numbers for the mating housing and crimp-style
snap-in terminals are listed below. There may be equivalent connectors available from
other manufacturers.
J1 Molex P/N
Connector Circuits (pins) 2 of 3
PCB Header (tin) 26-62-4030
Mating Housing 09-50-8031
Rated Contact Current 7.0 A
Crimp Terminal (tin) 08-50-0113
Rated Wire Size AWG 18 or 20
Table 4-3 J1 Mating Connector
4.8.2 DC Output Connector (J2)
Except for the XL125/160-05DC, the DC output connector is a Molex KK-156 style
header with 0.156” centers. The Molex part numbers for the mating housing and crimp-
style snap-in terminals are listed below. There may be equivalent connectors available
from other manufacturers.
J2 XL125/160-1DC, -8DC XL125/160-05…56DC
Connector Circuits (pins) 14 6
Mating Housing 09-50-8141 09-50-8061
Rated Contact Current 7.0 A 7.0 A
Crimp Terminal (tin) 08-52-0072 08-52-0072
Rated Wire Size AWG 18 or 20 AWG 18 or 20
Table 4-4 J2 Mating Connectors
XL125/160DC Series Product Specification
703152 Rev 07-01-19
General Specifications 4-5
4.8.3 Remote Sense / PG Connector (J3)
The Remote Sense/PG connector on the XL125/160DC is a Molex KK-100 style header
with 0.100” centers. The Molex part numbers for the mating housing and crimp-style
snap-in terminals are listed below. There may be equivalent connectors available from
other manufacturers.
J3 XL125/160-1DC, -8DC XL125/160-05DC XL125/160-12…56DC
Connector Circuits (pins) 3 5 6
Mating Housing 22-01-3037 22-01-3057 22-01-3067
Rated Contact Current 2.5 A 2.5 A 2.5 A
Crimp Terminal (tin) 08-50-0114 08-50-0114 08-50-0114
Rated Wire Size AWG 22-30 AWG 22-30 AWG 22-30
Table 4-5 J3 Mating Connectors
4.8.4 12V Aux Connector (J4)
The 12V AUX connector found on models XL125/160-05DC through XL125/160-56DC is
a 2-pin Molex style header with 0.100” centers. The Molex part numbers for the mating
housing and crimp-style snap-in terminals are listed below. There may be equivalent
connectors available from other manufacturers.
J4 XL125/160-05…56DC
Connector Circuits (pins) 2
Mating Housing 22-01-3027
Rated Contact Current 2.5 A
Crimp Terminal (tin) 08-50-0114
Rated Wire Size AWG 22-30
Table 4-6 12V Aux Mating Connectors
4.9 Output Grounding
The DC RETURN signal may be connected to the power supply chassis ground (safety
ground) at the plated through mounting hole near the input connector.
XL125/160DC Series Product Specification
703152 Rev 07-01-19
General Specifications 4-6
4.10 Signal Pin Definitions
There are three output connector configurations for the XL125/XL160DC Series
Identical signal names are connected together on all connectors
The Auxiliary 12V supply floats only on models XL125/160-12DC through –56DC
The safety ground connection is provided by the mounting screw near J1
Refer to Figure 4-3 for connector and pin-1 locations
Pin XL125/160
-1DC
XL125/160
-8DC
XL160
-05DC
XL125
-05DC
XL125/160
-12 thru -56DC
J1-1 DC + Input DC + Input DC + Input DC + Input DC + Input
J1-2 No Pin No Pin No Pin No Pin No Pin
J1-3 DC – Input DC – Input DC – Input DC – Input DC – Input
J2-1 -12V AUX (Fan) -12V AUX (Fan) V1 (+ Output) V1 (+ Output) V1 (+ Output)
J2-2 V3 (+12V Output) V3 (+12V Output) V1 (+ Output) V1 (+ Output) V1 (+ Output)
J2-3 V1 (+3.3V Output) V3 (+12V Output) V1 (+ Output) V1 (+ Output) V1 (+ Output)
J2-4 V1 (+3.3V Output) V3 (+12V Output) DC RETURN (0V) V1 (+ Output) DC RETURN (0V)
J2-5 V1 (+3.3V Output) V3 (+12V Output) DC RETURN (0V) V1 (+ Output) DC RETURN (0V)
J2-6 DC RETURN (0V) DC RETURN (0V) DC RETURN (0V) DC RETURN (0V) DC RETURN (0V)
J2-7 DC RETURN (0V) DC RETURN (0V) DC RETURN (0V)
J2-8 DC RETURN (0V) DC RETURN (0V) DC RETURN (0V)
J2-9 DC RETURN (0V) DC RETURN (0V) DC RETURN (0V)
J2-10 DC RETURN (0V) DC RETURN (0V) DC RETURN (0V)
J2-11 V2 (+5V Output) V2 (+5V Output)
J2-12 V2 (+5V Output) V2 (+5V Output)
J2-13 V2 (+5V Output) V2 (+5V Output)
J2-14 V2 (+5V Output) V2 (+5V Output)
J3-1 0V Sense (–) 0V Sense (–) Current Share Current Share DC RETURN (0V)
J3-2 V1 Sense (+) V1 Sense (+) 0V Sense (–) 0V Sense (–) 0V Sense (–)
J3-3 Power Good Power Good V1 Sense (+) V1 Sense (+) V1 Sense (+)
J3-4 PS_OK PS_OK Current Share
J3-5 Power Good Power Good Power Good
J3-6 PS_OK
J4-1 V2 Sense (+) V2 Sense (+) 12V AUX (+) (Fan) 12V AUX (+) (Fan) 12V AUX (+) (Fan)
J4-2 No Pin No Pin 12V AUX (–) (Fan) 12V AUX (–) (Fan) 12V AUX (–) (Fan)
Table 4-7 Signal Pin Definitions
XL125/160DC Series Product Specification
703152 Rev 07-01-19
General Specifications 4-7
Figure 4-3 XL125/160-1DC, -8DC Output Connectors Layout
Figure 4-4 XL125/160-12…56DC [CS] Output Connectors Layout
Pin
1
Pin 1
J 2
J
3
J 4
Pin
1
Pin 1
J
2
J
3
J
4
Pin 1
Power Good LED
XL125/160DC Series Product Specification
703152 Rev 07-01-19
General Specifications 4-8
Figure 4-5 XL160-05DC [CS] Output Connectors Layout
Figure 4-6 XL125-05DC [CS] Output Connectors Layout
Pin1
Pin1
J2
J3
J4
Pin1
Power Good LED
Pin1
Pin1
J2
J3
J4
Power Good LED
Pin1
703152 Rev 07-01-19
5.
5.1 XL125-1, -8DC
The power supply efficiency varies with the following: input voltage, total output load,
load dis
tribution and between individual units. The following graph shows the typical
efficiency with
forced air
percentage of the total load contributed by each output is shown in
5-2
.
Figure 5-1
Output
V1
V2
V3
V4
Table 5-1
Load Distribution used for Efficiency Measurements
Efficiency
Efficiency
Efficiency
The power supply efficiency varies with the following: input voltage, total output load,
tribution and between individual units. The following graph shows the typical
forced air
cooling air at 25°C after a 15-minute warm-
up period. The
percentage of the total load contributed by each output is shown in
Table
5
Efficiency of XL125-1DC (Non Current Sharing)
Output
Rated
Voltage
Tested
Current Load
V1
+3.3 V 8.18A
V2
+5 V 10.00A
V3
+12 V 3.00A
V4
-12 V 1.00A
Load Distribution used for Efficiency Measurements
for XL125
-
5-1
Efficiency
The power supply efficiency varies with the following: input voltage, total output load,
tribution and between individual units. The following graph shows the typical
up period. The
5-1 and Table
-
1DC
703152 Rev 07-01-19
Figure 5-2
Output
V1
V2
V3
V4
Table 5-2
Load Distribution used for Efficiency Measurements
XL125/160DC Series Product Specification
Efficiency
Efficiency of XL125-8DC (Non Current Sharing)
Output
Rated
Voltage
Tested
Current Load
V1
+3.3 V
V2
+5 V 13.00A
V3
+12 V 4.00A
V4
-12 V 1.00A
Load Distribution used for Efficiency Measurements
for XL125
-
XL125/160DC Series Product Specification
5-2
-
8DC
703152 Rev 07-01-19
5.2 XL125-05DC
Efficiency
The power supply efficiency varies with the following: input voltage, total output load,
and between individual units. The following graphs show the typical
forced air cooling air at 25°C after a 15
Figure 5-3
Figure 5-4
XL125/160DC Series Product Specification
Efficiency
Efficiency
The power supply efficiency varies with the following: input voltage, total output load,
and between individual units. The following graphs show the typical efficiency with
forced air cooling air at 25°C after a 15
-minute warm-up period.
Efficiency of XL125-05DC CS (Current Sharing)
Efficiency of XL125-05DC (Non Current Sharing)
XL125/160DC Series Product Specification
5-3
The power supply efficiency varies with the following: input voltage, total output load,
efficiency with
703152 Rev 07-01-19
5.3 XL125-12…
56DC
The power supply efficiency varies with the following: input voltage, total output load,
and between individual units. The following graphs show the typical efficiency with
fo
rced air cooling air at 25°C after a 15
Figure
Figure 5-6
Efficiency of XL125
XL125/160DC Series Product Specification
Efficiency
56DC
Efficiency
The power supply efficiency varies with the following: input voltage, total output load,
and between individual units. The following graphs show the typical efficiency with
rced air cooling air at 25°C after a 15
-minute warm-up period.
Figure
5-5 Efficiency of XL125-12DC CS (Current Sharing
)
Efficiency of XL125
-12DC (Non Current Sharing)
XL125/160DC Series Product Specification
5-4
The power supply efficiency varies with the following: input voltage, total output load,
and between individual units. The following graphs show the typical efficiency with
)
703152 Rev 07-01-19
Figure 5-7
Figure 5-8
Efficiency of XL125
XL125/160DC Series Product Specification
Efficiency
Efficiency of XL125-24DC CS (Current Sharing)
Efficiency of XL125
-24DC (Non Current Sharing)
XL125/160DC Series Product Specification
5-5
703152 Rev 07-01-19
Figure 5-9
Figure 5-10
XL125/160DC Series Product Specification
Efficiency
Efficiency of XL125-48DC CS (Current Sharing)
Efficiency of XL125-48DC (Non Current Sharing)
XL125/160DC Series Product Specification
5-6
703152 Rev 07-01-19
Figure 5-11
Figure 5-12
XL125/160DC Series Product Specification
Efficiency
Efficiency of XL125-54DC CS (Current Sharing)
Efficiency of XL125-54DC (Non Current Sharing)
XL125/160DC Series Product Specification
5-7
703152 Rev 07-01-19
Figure 5-13
Figure 5-14
XL125/160DC Series Product Specification
Efficiency
Efficiency of XL125-56DC CS (Current Sharing)
Efficiency of XL125-56DC (Non Current Sharing)
XL125/160DC Series Product Specification
5-8
703152 Rev 07-01-19
5.4 XL160-1, -
8DC Efficiency
The power supply efficiency varies with the
and between individual units. The following graphs show the typical efficiency with
forced air cooling air at 25°C after a 15
total load contributed by each output is
Figure
5
Output
V1
V2
V3
V4
Table 5-3
Load Distribution used for Efficiency Measurements
XL125/160DC Series Product Specification
Efficiency
8DC Efficiency
The power supply efficiency varies with the following: input voltage, total output load,
and between individual units. The following graphs show the typical efficiency with
forced air cooling air at 25°C after a 15
-minute warm-up period.
The percentage of the
total load contributed by each output is
shown in Table 5-3 and Table 5-4
.
5
-15 Efficiency of XL160-1DC (Non Current Sharing)
Output
Rated
Voltage
Tested
Current Load
V1
+3.3 V 10.0A
V2
+5 V 13.5A
V3
+12 V 4.0A
V4
-12 V 1.0A
Load Distribution used for Efficiency Measurements
for XL160
-
XL125/160DC Series Product Specification
5-9
following: input voltage, total output load,
and between individual units. The following graphs show the typical efficiency with
The percentage of the
.
-
1DC
703152 Rev 07-01-19
Figure 5-16
Output
V1
V2
V3
V4
Table 5-4
Load Distribution used for Efficiency
XL125/160DC Series Product Specification
Efficiency
Efficiency of XL160-8DC (Non Current Sharing)
Output
Rated
Voltage
Tested
Current Load
V1
+3.3 V
V2
+5 V 17.6A
V3
+12 V 5.0A
V4
-12 V 1.0A
Load Distribution used for Efficiency
Measurements for XL160
-
XL125/160DC Series Product Specification
5-10
-
8DC
703152 Rev 07-01-19
5.5 XL160-05DC
Efficiency
The power supply efficiency varies with the following: input voltage, total output
load, and between individual units. The following graphs show the typical efficiency
with forced air cooling air at 25°C
Figure 5-17
Figure 5-18
XL125/160DC Series Product Specification
Efficiency
Efficiency
The power supply efficiency varies with the following: input voltage, total output
load, and between individual units. The following graphs show the typical efficiency
with forced air cooling air at 25°C
after a 15-minute warm-up period.
Efficiency of XL160-05DC CS (Current Sharing)
Efficiency of XL160-05DC (Non Current Sharing)
XL125/160DC Series Product Specification
5-11
The power supply efficiency varies with the following: input voltage, total output
load, and between individual units. The following graphs show the typical efficiency
703152 Rev 07-01-19
5.6 XL160-
12…56DC Efficiency
The power supply efficiency varies with the following: input voltage, total output
load, and between individual units. The following graphs show the typical efficiency
with forced air cooling air at 25°C after a 15
Figure 5-19
Figure 5-20
XL125/160DC Series Product Specification
Efficiency
12…56DC Efficiency
The power supply efficiency varies with the following: input voltage, total output
load, and between individual units. The following graphs show the typical efficiency
with forced air cooling air at 25°C after a 15
-minute warm-up period.
Efficiency of XL160-12DC CS (Current Sharing)
Efficiency of XL160-12DC (Non Current Sharing)
XL125/160DC Series Product Specification
5-12
The power supply efficiency varies with the following: input voltage, total output
load, and between individual units. The following graphs show the typical efficiency
703152 Rev 07-01-19
Figure 5-21
Figure 5-22
XL125/160DC Series Product Specification
Efficiency
Efficiency of XL160-24DC CS (Current Sharing)
Efficiency of XL160-24DC (Non Current Sharing)
XL125/160DC Series Product Specification
5-13
703152 Rev 07-01-19
Figure 5-23
Figure 5-24
XL125/160DC Series Product Specification
Efficiency
Efficiency of XL160-48DC CS (Current Sharing)
Efficiency of XL160-48DC (Non Current Sharing)
XL125/160DC Series Product Specification
5-14
703152 Rev 07-01-19
Figure 5-25
Figure 5-26
XL125/160DC Series Product Specification
Efficiency
Efficiency of XL160-54DC CS (Current Sharing)
Efficiency of XL160-54DC (Non Current Sharing)
XL125/160DC Series Product Specification
5-15
703152 Rev 07-01-19
Figure 5-27
Figure 5-28
XL125/160DC Series Product Specification
Efficiency
Efficiency of XL160-56DC CS (Current Sharing)
Efficiency of XL160-56DC (Non Current Sharing)
XL125/160DC Series Product Specification
5-16
703152 Rev 07-01-19
Timing and Control 6-1
6. Timing and Control
6.1 Power Supply Timing
VAC
V1
PWR
GOOD
Reg.
10%
T1
T2
T4
T3
T5
T6
T1
T2
T3
T4
T5
T6
Min Max
1.0S
<200
µ
S
*
>20mS
>2mS
500mS
20mS
--
--
--
90%
* No Load Capacitance
Reg.
10%
90%
Figure 6-1 Timing Diagram
6.2 Power Good Signal/PS_OK Signal/Remote ON Input
The Power Good Signal provides a high logic level to indicate that sufficient time has
expired for the DC outputs to be within their regulation limits. When the input power is
removed, the Power Good Signal transitions to a low logic level. The PS_OK signal is the
logical complement of the Power Good signal and both signals are driven by open-
collector transistors. XL125/160-1DC and –8DC models add a TTL compatible pull-up
resistor on just the Power Good output. The electrical specifications for the Power Good
and PS_OK outputs are described in Table 6-1.
XL125/160DC Series Product Specification
703152 Rev 07-01-19
Timing and Control 6-2
Signal Type +5VDC, TTL Compatible
Low Logic Level <0.4V when sinking 4mA
High Logic Level Open Collector Output (see next)
Power Good
Pullup Resistor
TTL compatible only on XL125/160-1DC and -8DC
models
Power On Delay Less than 500mS after V1 outputs reaches regulation
Power Down Warning >2 mS before V1 reaches minimum regulated output
Rise Time <200 μS from 10% to 90% point.
PS_OK Logical complement of Power Good signal. Open
collector output without a pull-up resistor
Table 6-1 Status Signal Specifications
6.3 Power Good LED
A green LED on XL160-05DC through -56DC models illuminates whenever the Power
Good signal is true (high). See Figure 4-3 for the LED location near the output connector.
6.4 Power Sequencing: XL125/160-1DC and XL125/160-8DC
The +12V and +5V output voltages are equal to or greater than the V1 (+2.5V or +3.3V)
output voltage at all times during power up and normal operation. The time between the
+5V output reaching minimum in-regulation voltage and the V1 output reaching
minimum in-regulation voltage shall be less than 20 milliseconds.
703152 Rev 07-01-19
Ordering Information 7-1
7. Ordering Information
The following table provides the N2Power part numbers that should appear on your
purchase order and will appear on all N2Power correspondence:
125-W Versions 160-Watt Versions
Main Outputs
Model
Number
Part
Number
Model
Number
Part
Number
Without active current sharing (lower cost)
+3.3V, +5V,
+12V, -12V
XL125-1DC 400070-61-1 XL160-1DC 400080-01-6
+5V,
+12V, -12V
XL125-8DC 400070-68-6 XL160-8DC 400080-08-1
5V XL125-05DC 400071-01-5 XL160-05DC 400083-02-8
12V XL125-12DC 400071-63-5 XL160-12DC 400083-03-6
15V XL125-15DC 400071-64-3 XL160-15DC 400083-04-4
24V XL125-24DC 400071-65-0 XL160-24DC 400083-05-1
48V XL125-48DC 400071-66-8 XL160-48DC 400083-06-9
54V POE XL125-54DC 400071-67-6 XL160-54DC 400083-07-7
56V POE XL125-56DC 400071-68-4 XL160-56DC 400083-08-5
With active current sharing
5V XL125-05DC CS 400070-01-7 XL160-05DC CS 400080-02-4
12V XL125-12DC CS 400070-63-7 XL160-12DC CS 400080-03-2
15V XL125-15DC CS 400070-64-1 XL160-15DC CS 400080-04-0
24V XL125-24DC CS 400070-65-2 XL160-24DC CS 400080-05-7
48V XL125-48DC CS 400070-66-0 XL160-48DC CS 400080-06-5
54V POE XL125-54DC CS 400070-69-4 XL160-54DC CS 400080-09-9
56V POE XL125-56DC CS 400070-70-2 XL160-56DC CS 400080-10-7
POE Models provide 1500VDC output isolation while the others are rated at 50V.
Table 7-1 XL125/XL160-DC Model and Part Numbers
All XL125/XL160-DC models are RoHS compliant. For warranty information refer to
www.n2power.com . Direct all questions, orders or requests for quotation as follows:
N2Power Order Desk: orders@n2power.com
805-583-7744 x112
Fax (Attention N2Power): 805-978-5212
Sales: sales@n2power.com
805-583-7744 x122
Technical Support: techsupport@n2power.com
805-583-7744 x119
Street Address: 1267 Flynn Road