OUTPUT VALUES
Output Voltage2 (Vout): lout = 100mA
Output High Vout = Vs - 1V max
Output Low Vout = 0V + 0.5V max
PWM
Duty cycle in air 25% ± 10%
Duty cycle in liquid 75% ± 10%
Frequency 2kHz ± 10%
Other sensor options available on request, email:
technical@sstsensing.com
Need help? Ask the expert
Tel: + 44 (0)1236 459 020
and ask for “Technical”
BENEFITS
Low power
Low cost
Compact design
TECHNICAL SPECIFICATIONS
Supply voltage (Vs) 4.5VDC to 15.4VDC
Supply current (ls) 2.5mA max. (Vs = 15.4VDC)
Output sink and source
current (lout) 100mA
Operating temperatures Standard: -25°C to +80°C
Extended: -40°C to +125°C
Storage temperatures Standard: -30°C to +85°C
Extended: -40°C to +125°C
Housing material Trogamid® or Polysulfone1
Sensor termination 24AWG, 250mm PTFE
wires, 8mm tinned
Housing/
Mounting
Output Type / Logic Supply
Voltage
Output
Current
Temp
FEATURES
Liquid level switches that can detect almost any liquid type;
oil or water based
Choice of material; Trogamid® or Polysulfone
Choice of threads and terminal connections
DATA SHEET
Liquid Level Switches
Optomax Digital Series
1) Before use check that the fluid in which you wish to use these devices is compatible either with Trogamid® or
Polysulfone.
2) Voltages applicable to output value stated.
NOTES
1) Hex nut and O-ring sold separately; email: technical@sstsensing.com for details.
2) NPT version can be sealed with PTFE tape.
3) When correctly sealed.
NOTES
OUTLINE DRAWING
All dimensions shown in mm. Tolerances = ±1mm.
HOUSING SPECIFICATIONS
ELECTRICAL INTERFACE
Wire Designation
Red Vs
Green Output
Blue 0V
LLx5x0 Series
LLx2x0 Series
LLx6x0 Series
LLx7x0 Series
Housing Series
5x0 2x0 6x0 7x0
Thread M10x1
M12x1x8g
with
hex nut1
1/2” SAE
with
O-ring1
1/4” NPT2
Pressure3 20 bar 7 bar maximum
Tightening
Torque 1.5 Nm / 13.26 in-lbs maximum
CIRCUIT DIAGRAMS
In order to suit any application, these sensors have been designed with various output circuit configurations.
CAUTION: Take care when connecting loads.
The minimum load impedance should not exceed Vs/max output current.
Note: Shorting the output to Vs or 0V will result in irreparable damage to the sensor.
ORDER INFORMATION
Generate your specific part number using the convention shown opposite. Use only those letters and numbers that
correspond to the sensor and output options you require — omit those you do not.
Sensor mounted from inside vessel Sensor mounted from outside vessel
Notes:
5x0 series sensors are mounted internally
2x0, 6x0 & 7x0 series sensors are mounted externally
SH suffix applicable to 2x0, 6x0 & 7x0 series sensors only; omit from 5x0 series sensor part number
Please contact SST Sensing for details; email: technical@sstsensing.com
Housing
Material
Housing
Type
Operating
Temp.
Output
Logic
C
Polysulfone
2
2x0 SH series
M12x1
0
-25 °C
to +80°C
Blank
Output
High in air
T
Trogamid®
6
6x0 SH series
1/2” SAE
1
-40 °C
to +125°C
L
Output
Low in air
7
7x0 SH series
1/4” NPT
P
PWM output
L L X X X 0 D 3 X S H
Housing
Material
Operating
Temp.
Output
Logic
C
Polysulfone
0
-25 °C
to +80°C
Blank
Output
High in air
T
Trogamid®
1
-40 °C
to +125°C
L
Output
Low in air
P
PWM output
L L X 5 X 0 D 3 X
General Note: SST Sensing Ltd. reserves the right to make changes to product specifications without notice or liability.
All information is subject to SST Sensing Ltd.'s own data and considered accurate at time of going to print.
DS-0032 REV 12 © 2016 SST SENSING LTD.
5 H A GMI LL C RES E NT, S HA W HEA D IN DU STRIA L E S T ATE , COA TB RI D GE, U K M L5 4 NS
ww w .s st s e ns i ng . co m | e: s al e s @s s t s e ns in g .c o m | t : + 44 ( 0 )12 36 4 5902 0 | f: + 4 4 (0 ) 123 6 459 02 6
CAUTION
Do not exceed maximum ratings and ensure sensor(s) are operated in
accordance with their requirements.
Carefully follow all wiring instructions. Incorrect wiring can cause
permanent damage to the device.
SST Sensing Ltd recommend using alcohol based cleaning agents.
Do NOT use chlorinated solvents such as tricholerthane as these are
likely to attack the sensor material.
Failure to comply with these instructions may result in product
damage.
INFORMATION
As customer applications are outside of SST Sensing Ltd.’s control, the
information provided is given without legal responsibility. Customers
should test under their own conditions to ensure that the equipment is
suitable for their intended application. Before use, check that the fluid in
which you wish to use these devices is compatible with Polysulfone or
Trogamid®.
For technical assistance or advice, please email:
technical@sstsensing.com