Product data sheet Characteristics XACA2014 pendant station XAC-A pistol grip - 2 push buttons 1 Emergency stop Range of product Harmony XAC Product or component type Pendant control station Control station name XACA pistol grip Control station type Double insulated Enclosure material Polypropylene Control type Intuitive Electrical circuit type Control circuit Enclosure type Complete ready for use Control station application Control of single speed hoist motor Control station composition 2 pushbuttons + 1 emergency stop Control button type Second pushbutton 1 NO lower, slow First pushbutton 1 NO raise, slow Emergency stop pushbutton O 30 mm 1 NC, trigger action Contact block name ZB2BE102 for emergency stop ZB2BE101 for each direction Mechanical interlocking With mechanical interlocking Complementary Control station colour Yellow Connections - terminals Screw clamp terminals, connection capacity: 2 x 1.5 mm with or without cable end Screw clamp terminals, connection capacity: 1 x 2.5 mm with or without cable end Mechanical durability 1000000 cycles Cable entry Rubber sleeve with stepped entry, cable outer diameter: 7...15 mm Contact code designation Q600 DC-13, Ue = 600 V, Ie = 0.1 A conforming to IEC 60947-5-1 appendix A Q600 DC-13, Ue = 250 V, Ie = 0.27 A conforming to IEC 60947-5-1 appendix A A600 AC-15, Ue = 600 V, Ie = 1.2 A conforming to IEC 60947-5-1 appendix A A600 AC-15, Ue = 240 V, Ie = 3 A conforming to IEC 60947-5-1 appendix A [Ithe] conventional enclosed thermal current 10 A [Ui] rated insulation voltage 600 V (degree of pollution: 3) conforming to IEC 60947-1 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-1 Contacts operation Slow-break Resistance across terminals <= 25 MOhm Operating force 13...15 N Short circuit protection 10 A fuse protection by cartridge fuse type gG Rated operational power in W 65 W DC-13 for 1000000 cycles, operating rate = 60 cyc/mn at 24 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C 48 W DC-13 for 1000000 cycles, operating rate = 60 cyc/mn at 48 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C 40 W DC-13 for 1000000 cycles, operating rate = 60 cyc/mn at 120 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C Terminals description ISO n1 (13-14)NO Terminals description ISO n2 (11-12)NC Terminal identifier (11-12)NC (13-14)NO Product weight 0.31 kg Mar 18, 2014 1 The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein. This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein. Main Environment Standards EN/IEC 60204-32 EN/IEC 60947-5-1 EN/IEC 60947-5-5 EN/ISO 13850: 2006 UL 508 CSA C22.2 No 14 Product certifications CSA UL Protective treatment TH Ambient air temperature for operation -25...70 C Ambient air temperature for storage -40...70 C Vibration resistance 15 gn (f = 10...500 Hz) conforming to IEC 60068-2-6 Shock resistance 100 gn conforming to IEC 60068-2-27 Class of protection against electric shock Class II conforming to IEC 61140 IP degree of protection IP65 conforming to IEC 60529 IK degree of protection IK08 conforming to EN 50102 2 Product data sheet Dimensions Drawings XACA2014 Dimensions (1) (2) With trigger action latching O 30 mm / 1.18 in. Emergency stop. Internal O 3 Product data sheet Connections and Schema Control of Single-Speed Reversing Motor 4 XACA2014 XACA2014 Product data sheet Performance Curves Rated Operational Power AC Supply 50/60 Hz Inductive Circuit Operating rate: 3600 operating cycles/hour. Load factor: 0.5. Millions of operating cycles, AC-15 utilization category Ithe Thermal current (A) Current DC Supply Operating rate: 3600 operating cycles/hour. Load factor: 0.5. Power broken in W for 1 million operating cycles, DC-13 utilization category Voltage V 24 48 120 Inductive circuit W 65 48 40 5 Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Schneider Electric: XACA2014