The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein.
This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications.
It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof.
Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.
Mar 18, 2014
1
Product data sheet
Characteristics
XACA2014
pendant station XAC-A pistol grip - 2 push
buttons 1 Emergency stop
Main
Range of product Harmony XAC
Product or component
type
Pendant control station
Control station name XACA pistol grip
Control station type Double insulated
Enclosure material Polypropylene
Control type Intuitive
Electrical circuit type Control circuit
Enclosure type Complete ready for use
Control station applica-
tion
Control of single speed hoist motor
Control station compo-
sition
2 pushbuttons + 1 emergency stop
Control button type Second pushbutton 1 NO lower, slow
First pushbutton 1 NO raise, slow
Emergency stop pushbutton Ø 30 mm 1 NC, trigger
action
Contact block name ZB2BE102 for emergency stop
ZB2BE101 for each direction
Mechanical interlocking With mechanical interlocking
Complementary
Control station colour Yellow
Connections - terminals Screw clamp terminals, connection capacity: 2 x 1.5 mm² with or without cable
end
Screw clamp terminals, connection capacity: 1 x 2.5 mm² with or without cable
end
Mechanical durability 1000000 cycles
Cable entry Rubber sleeve with stepped entry, cable outer diameter: 7...15 mm
Contact code designation Q600 DC-13, Ue = 600 V, Ie = 0.1 A conforming to IEC 60947-5-1 appendix A
Q600 DC-13, Ue = 250 V, Ie = 0.27 A conforming to IEC 60947-5-1 appendix A
A600 AC-15, Ue = 600 V, Ie = 1.2 A conforming to IEC 60947-5-1 appendix A
A600 AC-15, Ue = 240 V, Ie = 3 A conforming to IEC 60947-5-1 appendix A
[Ithe] conventional enclosed thermal current 10 A
[Ui] rated insulation voltage 600 V (degree of pollution: 3) conforming to IEC 60947-1
[Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-1
Contacts operation Slow-break
Resistance across terminals <= 25 MOhm
Operating force 13...15 N
Short circuit protection 10 A fuse protection by cartridge fuse type gG
Rated operational power in W 65 W DC-13 for 1000000 cycles, operating rate = 60 cyc/mn at 24 V, load factor
= 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C
48 W DC-13 for 1000000 cycles, operating rate = 60 cyc/mn at 48 V, load factor
= 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C
40 W DC-13 for 1000000 cycles, operating rate = 60 cyc/mn at 120 V, load factor
= 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C
Terminals description ISO n°1 (13-14)NO
Terminals description ISO n°2 (11-12)NC
Terminal identifier (11-12)NC
(13-14)NO
Product weight 0.31 kg
2
Environment
Standards EN/IEC 60204-32
EN/IEC 60947-5-1
EN/IEC 60947-5-5
EN/ISO 13850: 2006
UL 508
CSA C22.2 No 14
Product certifications CSA
UL
Protective treatment TH
Ambient air temperature for operation -25...70 °C
Ambient air temperature for storage -40...70 °C
Vibration resistance 15 gn (f = 10...500 Hz) conforming to IEC 60068-2-6
Shock resistance 100 gn conforming to IEC 60068-2-27
Class of protection against electric shock Class II conforming to IEC 61140
IP degree of protection IP65 conforming to IEC 60529
IK degree of protection IK08 conforming to EN 50102
3
Product data sheet
Dimensions Drawings
XACA2014
Dimensions
(1) With trigger action latching Ø 30mm / 1.18in. Emergency stop.
(2) Internal Ø
4
Product data sheet
Connections and Schema
XACA2014
Control of Single-Speed Reversing Motor
5
Product data sheet
Performance Curves
XACA2014
Rated Operational Power
AC Supply 50/60 Hz Inductive Circuit
Operating rate: 3600 operating cycles/hour. Load factor: 0.5.
Millions of operating cycles, AC-15 utilization category
Ithe Thermal current
(A) Current
DC Supply
Operating rate: 3600 operating cycles/hour. Load factor: 0.5.
Power broken in W for 1 million operating cycles, DC-13 utilization category
Voltage V 24 48 120
Inductive circuit W 65 48 40
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Schneider Electric:
XACA2014