DECISION TABLES
Basic Product Series
Contact Operation
F=Fan(closeonrise)
L=Limit(openonrise)
Operating Temperature
in°C,3digits(fromabovetable,put“0”infrontof2digittemps)
Factory Assigned Number
Nondescript,4digitdashnumberassignedfora
customer’sspecialrequirements.Thedashand
factoryassignednumberisnotrequiredfor
orderingastandardproduct
66 F 0 9 5 5 5 8 8
OPERATE (±5°C) MIN DIFFERENTIAL (°C) MIN RESET (°C)
40 4 20
45 4 20
50 4 30
55 4 30
60 4 40
65 4 40
70 4 50
75 4 50
80 6 55
85 6 55
90 6 60
95 6 60
100 6 70
105 6 70
110 6 80
115 6 85
120 9 90
125 9 90
130 9 90
STANDARD TEMPERATURE CALIBRATION TABLE
Eachthermostatpartnumberconsistsoffunctional
“buildingblocks”toenabletheusertospecifyclearly
andpreciselythedesiredcharacteristicsineach
category.Selectthepropercodeineachcategory,
thentransferittotheboxindicated.Unlessaspecial
requirementisindicated,thepartnumberwillbe
completewhenthepropertemperatureisselected.If
youhaveaspecialrequirement,pleasecallSensatafor
afactoryassignednumbertocompletethepartnumber.
Example :
A66F095thermostatwillclose(makecontact)onarising
temperaturefrom90°Cto100°Candwillresetopen
(breakcontact)onafallingtemperaturewithinawindow
ofnogreaterthan6°Clowerthantheactualclose
temperatureandnolessthan60°Cambienttemperature.
Specialrequirementsrequirea4digitmanufacturing
dashnumberfororderingspecialfeatures,4digit
markingmaynotappearaspartofthemarkingonthe
thermostat.
SpecialrequirementsmayincludeVDE,±3.0°C(±5.4°F)
operatingtemperaturetolerance,orsurfacemount
(gullwing,SMT).
TemperaturesetpointcalibrationischeckedatSensata
Technologieswithprecisiontestequipmenttraceableto
theUSNationalInstituteofStandardsandTechnology
andProvenMethods.Becausecustomerchecking
methodsmaydiffer,atypicalvarianceallowedfor
correlationis±1.1°C(±2.0°F).
6600&6700Series
6600 Series - Decision Tables 36