Basic Panels ___________________ Preface 1 ___________________ Overview SIMATIC HMI HMI devices Basic Panels 2 ___________________ Safety instructions 3 ___________________ Mounting and connecting 4 ___________________ Operating the device 5 ___________________ Configuring the HMI device Operating Instructions 6 ___________________ Commissioning a project 7 ___________________ Maintenance and care 8 ___________________ Technical specifications A ___________________ Technical Support B ___________________ Abbreviations 04/2012 A5E02421799-03 Legal information Legal information Warning notice system This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are graded according to the degree of danger. DANGER indicates that death or severe personal injury will result if proper precautions are not taken. WARNING indicates that death or severe personal injury may result if proper precautions are not taken. CAUTION with a safety alert symbol, indicates that minor personal injury can result if proper precautions are not taken. CAUTION without a safety alert symbol, indicates that property damage can result if proper precautions are not taken. NOTICE indicates that an unintended result or situation can occur if the relevant information is not taken into account. If more than one degree of danger is present, the warning notice representing the highest degree of danger will be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property damage. Qualified Personnel The product/system described in this documentation may be operated only by personnel qualified for the specific task in accordance with the relevant documentation, in particular its warning notices and safety instructions. Qualified personnel are those who, based on their training and experience, are capable of identifying risks and avoiding potential hazards when working with these products/systems. Proper use of Siemens products Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems. The permissible ambient conditions must be complied with. The information in the relevant documentation must be observed. Trademarks All names identified by (R) are registered trademarks of Siemens AG. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner. Disclaimer of Liability We have reviewed the contents of this publication to ensure consistency with the hardware and software described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the information in this publication is reviewed regularly and any necessary corrections are included in subsequent editions. Siemens AG Industry Sector Postfach 48 48 90026 NURNBERG GERMANY A5E02421799-03 04/2012 Technical data subject to change Copyright (c) Siemens AG 2012. All rights reserved Preface Purpose of the operating instructions These operating instructions provide information based on the requirements defined by IEC 62079 for documentation. This information relates to the HMI device, its storage, transportation, place of use, installation, use and maintenance. These operating instructions are intended for a variety of target groups. The following table shows the chapters of these operating instructions that are of particular importance for the respective target group. Target group Chapter All "Safety instructions" Operators "Overview" The operator operates and monitors the system during the process control phase. "Operating a project" Commissioning engineers All chapters. The commissioning engineer integrates the HMI device into the system and ensures the operating capability of the HMI device for the process control phase. Depending on the use of the HMI device, certain chapters may not be of relevance to the commissioning engineer, e.g. the section "Maintenance and servicing." Service technicians All chapters. Service technicians rectify faults that occur during the process control phase. Depending on the use of the HMI device, certain chapters may not be of relevance to the service technicians, e.g. the section "Maintenance and servicing." Maintenance technicians Maintenance and care Maintenance technicians carry out servicing and maintenance work during the process control phase. The information system of WinCC flexible and WinCC contains further additional informaiton. The information system is integrated as online help in WinCC flexible and WinCC and contains instructions, examples and reference information in electronic form. Basic Panels Operating Instructions, 04/2012, A5E02421799-03 3 Preface Scope These operating instructions are valid for all SIMATIC HMI Basic Panels. The following naming conventions apply: Device designation Device type Interface type Can be configured with Keyboard unit Basic Panel PN WinCC (TIA Portal) as of V11 SIMATIC HMI KP300 Basic mono PN KP400 Basic color PN KTP400 Basic mono PN KTP400 Basic color PN WinCC (TIA Portal) as of V11 SP2 Update 2 with HSP Basic 4" color WinCC flexible and WinCC (TIA Portal) as of V11 Touch device with function keys WinCC (TIA Portal) as of V11 SP2 Update 2 with HSP Basic 4" color KTP600 Basic mono PN KTP600 Basic color DP Basic Panel DP KTP600 Basic color PN Basic Panel PN KTP1000 Basic color DP Basic Panel DP KTP1000 Basic color PN Basic Panel PN TP1500 Basic color PN WinCC flexible and WinCC (TIA Portal) as of V11 Touch device In addition, the following collective designations are also used in these operating instructions: Designation Covers the HMI devices KTP400 Basic KTP400 Basic mono PN, KTP400 Basic color PN KTP600 Basic KTP600 Basic mono PN, KTP600 Basic color DP, KTP600 Basic color PN KTP1000 KTP1000 Basic color DP, KTP1000 Basic color PN Basic knowledge required Knowledge of automation technology and process communication is necessary to understand the operating instructions. An understanding of the use of computers and operating systems is also required. Basic Panels 4 Operating Instructions, 04/2012, A5E02421799-03 Preface Illustrations and text highlighting This manual contains illustrations of the described devices. The illustrations may deviate from the supplied device in certain details. The following graphical highlighting facilitates reading these operating instructions: Graphical highlighting Description If the instructions involve several tasks, the individual tasks are highlighted by a red number circle. 0.2 Nm A light blue highlight indicates components and tools that are required in the course of a task. Safety instructions are highlighted by an orange frame. KTP600 Basic is sometimes shown in the illustrations as a representation of all Basic Panels. .7 3 The following text highlighting facilitates reading these operating instructions: Text highlighting Scope "Add screen" * Terms that appear in the user interface, for example, dialog names, tabs, buttons, menu commands * Input values, for example, limits, tag values * Path information "File > Edit" Operational sequences, for example, menu commands, shortcut menu commands Keyboard operation Configuration and runtime software have different names as follows: "WinCC flexible 2008" or "WinCC (TIA Portal) V11", for example, refers to the configuration software. The term "WinCC flexible" or "WinCC" is used in a general context. The full name, for example, "WinCC flexible 2008", is always used when it is necessary to differentiate between different versions of the configuration software. "WinCC flexible Runtime" or "WinCC Runtime" refers to the runtime software that can run on HMI devices. Basic Panels Operating Instructions, 04/2012, A5E02421799-03 5 Preface Note information highlighted as follows: Note A note contains important information on described products and their handling or on a section of this documentation. Trademarks Names labeled with a (R) symbol are registered trademarks of the Siemens AG. Other names used in this documentation may be trademarks, the use of which by third parties for their own purposes could violate the rights of the owner. HMI(R) SIMATIC(R) SIMATIC HMI(R) WinCC(R) Basic Panels 6 Operating Instructions, 04/2012, A5E02421799-03 Table of contents Preface ...................................................................................................................................................... 3 1 2 3 Overview.................................................................................................................................................. 11 1.1 Product Overview.........................................................................................................................11 1.2 Design of the KP300 Basic mono PN ..........................................................................................12 1.3 Design of the KP400 Basic color PN ...........................................................................................13 1.4 Design of the KTP400 Basic mono PN........................................................................................15 1.5 Design of the KTP400 Basic color PN .........................................................................................16 1.6 Design of the KTP600 Basic mono/color PN ...............................................................................17 1.7 Design of the KTP600 Basic color DP .........................................................................................18 1.8 Design of the KTP1000 Basic color PN .......................................................................................19 1.9 Design of the KTP1000 Basic color DP .......................................................................................20 1.10 Design of the TP1500 Basic color PN .........................................................................................21 1.11 Product package ..........................................................................................................................22 1.12 Accessories..................................................................................................................................23 1.13 Commissioning the HMI device ...................................................................................................24 Safety instructions ................................................................................................................................... 25 2.1 General safety instructions ..........................................................................................................25 2.2 Security information .....................................................................................................................26 2.3 Notes about usage.......................................................................................................................26 Mounting and connecting......................................................................................................................... 29 3.1 3.1.1 3.1.2 3.1.3 3.1.4 3.1.5 3.1.6 Preparations.................................................................................................................................29 Checking the package contents...................................................................................................29 Checking the operating conditions...............................................................................................29 Selecting a mounting position ......................................................................................................29 Checking clearances....................................................................................................................31 Making the mounting cut-out........................................................................................................31 Labeling the function keys ...........................................................................................................33 3.2 Mounting the HMI device .............................................................................................................34 3.3 3.3.1 3.3.2 3.3.3 3.3.4 3.3.5 3.3.6 Connecting the HMI device..........................................................................................................36 Connection sequence ..................................................................................................................36 Connecting the equipotential bonding circuit ...............................................................................38 Connecting the power supply.......................................................................................................39 Connecting a programming device ..............................................................................................41 Connecting the configuration PC .................................................................................................42 Connecting the PLC.....................................................................................................................45 Basic Panels Operating Instructions, 04/2012, A5E02421799-03 7 Table of contents 4 5 6 3.4 Switching on and testing the HMI device .................................................................................... 48 3.5 Securing the cables..................................................................................................................... 50 Operating the device................................................................................................................................ 51 4.1 4.1.1 4.1.2 4.1.3 4.1.4 Operating touch devices ............................................................................................................. 51 Overview ..................................................................................................................................... 51 General functions of the screen keyboard .................................................................................. 53 Entering data on the KTP400 Basic............................................................................................ 54 Entering data on the KTP600 Basic, KTP1000 Basic , TP1500 Basic ....................................... 57 4.2 4.2.1 4.2.2 Operating KP300 Basic............................................................................................................... 59 Overview ..................................................................................................................................... 59 Entering data on the KP300 Basic .............................................................................................. 60 4.3 4.3.1 4.3.2 Operating KP400 Basic............................................................................................................... 63 Overview ..................................................................................................................................... 63 Entering data on the KP400 Basic .............................................................................................. 66 Configuring the HMI device...................................................................................................................... 67 5.1 5.1.1 5.1.2 5.1.3 5.1.4 5.1.5 5.1.6 5.1.7 5.1.8 5.1.9 5.1.10 5.1.11 5.1.12 5.1.13 Configuring devices with graphical Control Panel ...................................................................... 67 Opening the Control Panel.......................................................................................................... 67 Overview ..................................................................................................................................... 68 Changing MPI/DP settings .......................................................................................................... 69 Changing the network configuration ........................................................................................... 70 Time server configuration............................................................................................................ 71 Changing monitor settings .......................................................................................................... 72 Displaying information about the HMI device.............................................................................. 73 Calibrating the touch screen ....................................................................................................... 74 Displaying licensing information for the HMI device ................................................................... 75 Enabling a data channel.............................................................................................................. 76 Changing password settings ....................................................................................................... 78 Setting the Screen Saver ............................................................................................................ 79 Setting acoustic signals............................................................................................................... 79 5.2 5.2.1 5.2.2 5.2.3 5.2.4 5.2.5 5.2.6 5.2.7 5.2.8 5.2.9 Configuring KP300 Basic ............................................................................................................ 80 Opening the Control Panel.......................................................................................................... 80 Overview ..................................................................................................................................... 81 Displaying information about the HMI device.............................................................................. 83 Changing monitor settings .......................................................................................................... 83 Enabling a data channel.............................................................................................................. 84 Changing the network configuration ........................................................................................... 85 Time server configuration............................................................................................................ 86 Changing password settings ....................................................................................................... 87 Setting the Screen Saver ............................................................................................................ 88 Commissioning a project.......................................................................................................................... 89 6.1 Overview ..................................................................................................................................... 89 6.2 Operating modes......................................................................................................................... 90 6.3 Data transmission options........................................................................................................... 91 Basic Panels 8 Operating Instructions, 04/2012, A5E02421799-03 Table of contents 7 8 6.4 6.4.1 6.4.2 6.4.3 6.4.4 Transfer........................................................................................................................................91 Overview ......................................................................................................................................91 Starting manual transfer...............................................................................................................91 Starting automatic transfer...........................................................................................................93 Testing a project ..........................................................................................................................95 6.5 6.5.1 6.5.2 6.5.3 6.5.4 Backup and restore......................................................................................................................96 Overview ......................................................................................................................................96 Backup and restore using WinCC flexible ...................................................................................97 Backup and restore using ProSave .............................................................................................99 Backup and restore using WinCC..............................................................................................100 6.6 6.6.1 6.6.2 6.6.3 6.6.4 OS update - Basic Panel DP......................................................................................................101 Overview ....................................................................................................................................101 Resetting factory settings...........................................................................................................102 Updating the Operating System using WinCC flexible ..............................................................102 Updating the Operating System using ProSave ........................................................................104 6.7 6.7.1 6.7.2 6.7.3 6.7.4 6.7.5 6.7.6 6.7.7 6.7.8 OS update - Basic Panel PN......................................................................................................105 Overview ....................................................................................................................................105 Resetting factory settings...........................................................................................................106 Updating the operating system using WinCC flexible................................................................106 Updating the operating system using ProSave..........................................................................108 Updating the operating system using WinCC ............................................................................109 Resetting to factory settings with WinCC flexible ......................................................................110 Resetting to factory settings with ProSave ................................................................................112 Resetting to factory settings with WinCC...................................................................................114 Maintenance and care ........................................................................................................................... 115 7.1 Maintenance and care ...............................................................................................................115 7.2 Recycling....................................................................................................................................116 Technical specifications......................................................................................................................... 117 8.1 Certificates and approvals .........................................................................................................117 8.2 8.2.1 8.2.2 Directives and declarations........................................................................................................118 Electromagnetic compatibility ....................................................................................................118 ESD guideline ............................................................................................................................119 8.3 8.3.1 8.3.2 8.3.3 8.3.4 8.3.5 8.3.6 8.3.7 8.3.8 8.3.9 Dimension drawings...................................................................................................................122 Dimension drawing of the KP300 Basic mono PN.....................................................................122 Dimension drawing of the KP400 Basic color PN......................................................................123 Dimension drawing of the KTP400 Basic mono PN ..................................................................124 Dimension drawing of the KTP400 Basic color PN....................................................................125 Dimension drawing of the KTP600 Basic color DP....................................................................126 Dimension drawing of the KTP600 Basic mono/color PN .........................................................127 Dimension drawing of the KTP1000 Basic color DP..................................................................128 Dimension drawing of the KTP1000 Basic color PN..................................................................129 Dimension drawing of the TP1500 Basic color PN ....................................................................130 Basic Panels Operating Instructions, 04/2012, A5E02421799-03 9 Table of contents A B 8.4 8.4.1 8.4.2 8.4.3 8.4.4 8.4.5 8.4.5.1 8.4.5.2 8.4.5.3 Specifications ............................................................................................................................ 131 Power supply............................................................................................................................. 131 KP300 Basic and KP400 Basic................................................................................................. 131 KTP400 Basic and KTP600 Basic ............................................................................................ 133 KTP1000 Basic and TP1500 Basic........................................................................................... 135 Ambient conditions.................................................................................................................... 137 Transport and storage conditions ............................................................................................. 137 Conditions of use ...................................................................................................................... 138 Information on insulation tests, protection class and degree of protection............................... 140 8.5 8.5.1 8.5.2 8.5.3 Interface description.................................................................................................................. 141 Power supply............................................................................................................................. 141 PROFIBUS (Sub-D RS422/485) ............................................................................................... 141 PROFINET (Ethernet) ............................................................................................................... 142 8.6 Functional scope with WinCC flexible and WinCC ................................................................... 143 Technical Support.................................................................................................................................. 147 A.1 Service and support .................................................................................................................. 147 A.2 System events........................................................................................................................... 148 Abbreviations......................................................................................................................................... 149 Glossary ................................................................................................................................................ 151 Index...................................................................................................................................................... 157 Basic Panels 10 Operating Instructions, 04/2012, A5E02421799-03 1 Overview 1.1 Product Overview Concentrating on the essentials - the new Basic Panels Today, visualization is part of the standard repertoire for most machines. The cost factor plays a crucial role in this case, especially for small machines and simple applications. HMI devices with basic functions are often fully sufficient for simple applications. This is exactly the demand that we intend to meet - with our new SIMATIC HMI Basic Panels. By concentrating on the essentials, the Basic Panels offer exactly those basic features that are demanded - at the right price. A perfect cost-to-performance ratio. Like all devices in our product catalog, the new Basic Panels offer proven SIMATIC quality and - regardless of their display dimensions - many software functions as standard: for example, an alarm system, recipe management, trend functionality and language switching. Users therefore profit from the advantages of visualization, such as improved process quality, even with simple applications. Basic Panels Operating Instructions, 04/2012, A5E02421799-03 11 Overview 1.2 Design of the KP300 Basic mono PN 1.2 Design of the KP300 Basic mono PN Power supply connector PROFINET interface Display Control keys Cutouts for a mounting clamp Function keys Rating plate Mounting seal Interface name Functional earth connection Basic Panels 12 Operating Instructions, 04/2012, A5E02421799-03 Overview 1.3 Design of the KP400 Basic color PN 1.3 Design of the KP400 Basic color PN Cutouts for mounting clamps Power supply connector PROFINET interface Function keys Control keys Data input keys Display Basic Panels Operating Instructions, 04/2012, A5E02421799-03 13 Overview 1.3 Design of the KP400 Basic color PN Rating plate Mounting seal Functional earth connection Guides for labeling strips Interface name Basic Panels 14 Operating Instructions, 04/2012, A5E02421799-03 Overview 1.4 Design of the KTP400 Basic mono PN 1.4 Design of the KTP400 Basic mono PN Power supply connector Functional earth connection PROFINET interface Cutouts for a mounting clamp Display/touch screen Mounting seal Guide for a labeling strip Function keys Rating plate Interface name Basic Panels Operating Instructions, 04/2012, A5E02421799-03 15 Overview 1.5 Design of the KTP400 Basic color PN 1.5 Design of the KTP400 Basic color PN Cutouts for mounting clamps Power supply connector PROFINET interface Display/touch screen Function keys Guide for a labeling strip Rating plate Mounting seal Interface name Functional earth connection Basic Panels 16 Operating Instructions, 04/2012, A5E02421799-03 Overview 1.6 Design of the KTP600 Basic mono/color PN 1.6 Design of the KTP600 Basic mono/color PN Power supply connector PROFINET interface Cutouts for a mounting clamp Display/touch screen Mounting seal Function keys Rating plate Interface name Guide for a labeling strip Functional earth connection Basic Panels Operating Instructions, 04/2012, A5E02421799-03 17 Overview 1.7 Design of the KTP600 Basic color DP 1.7 Design of the KTP600 Basic color DP Power supply connector RS-422/RS-485 interface Cutouts for a mounting clamp Display/touch screen Mounting seal Rating plate Interface name DIP switch Guide for a labeling strip Functional earth connection Function keys Basic Panels 18 Operating Instructions, 04/2012, A5E02421799-03 Overview 1.8 Design of the KTP1000 Basic color PN 1.8 Design of the KTP1000 Basic color PN Power supply connector PROFINET interface Cutouts for a mounting clamp Display/touch screen Mounting seal Rating plate Interface name Fixing element Functional earth connection Guide for labeling strips Function keys Basic Panels Operating Instructions, 04/2012, A5E02421799-03 19 Overview 1.9 Design of the KTP1000 Basic color DP 1.9 Design of the KTP1000 Basic color DP Power supply connector RS-422/RS-485 interface Cutouts for a mounting clamp Display/touch screen Mounting seal Function keys Rating plate DIP switch Interface name Fixing element Functional earth connection Guides for labeling strips Basic Panels 20 Operating Instructions, 04/2012, A5E02421799-03 Overview 1.10 Design of the TP1500 Basic color PN 1.10 Design of the TP1500 Basic color PN Power supply connector PROFINET interface Cutouts for a mounting clamp Display/touch screen Rating plate Interface name Fixing element Functional earth connection Mounting seal Basic Panels Operating Instructions, 04/2012, A5E02421799-03 21 Overview 1.11 Product package 1.11 Product package The following components are included in the product package of the HMI device. Name Figure Quantity HMI device 1 Quick Installation Guide 1 Mounting seal 1 Included with KTP 600 Basic and already installed with all other HMI devices. Mounting clamps with grub screw Plastic mounting clamps Aluminum mounting clamps Power supply terminal 4 KP300 Basic 7 KP400 Basic 5 KTP400 Basic color PN 5 KTP400 Basic mono PN 6 KTP600 Basic 12 KTP1000 Basic 14 TP1500 Basic 1 Basic Panels 22 Operating Instructions, 04/2012, A5E02421799-03 Overview 1.12 Accessories 1.12 Accessories Accessories are not included in the product package of the HMI device, but can ordered on the Internet under Industry Mall (http://mall.automation.siemens.com). This section contains the number of accessories available at the time of publication of the operating instructions. Converters, adapters and connectors 1 Name Purpose Order no. RS 422 to RS 232 converter Connection of third-party controllers to Basic Panels DP 6AV6671-8XE00-0AX0 PC/PPI cable Converts RS 422/RS 485 signals to RS 232 signals. Is required for updating the operating system with reset to factory settings 1. Can also be used for the transfer. 6ES7 901-3CB30-0XA0 90 degree elbow adapter For RS422/RS485 interface, cable outlet to rear 6AV6671-8XD00-0AX0 USB/PPI cable Converts RS 422/RS 485 signals to USB signals. Is required for updating the operating system with reset to factory settings. Can also be used for the transfer. 6ES7 901-3DB30-0XA0 PROFIBUS connector Recommended PROFIBUS connector with straight cable outlet 6GK1500-0FC10 PROFINET RJ45 connector "IE FC RJ45 Plug 2x2" Required for connection of Basic Panels PN to PROFINET 6GK1901-1BB10-2AA0 If the connection is lost during the operating system update, set a lower bit rate. If you use a higher bit rate, you must use the PC/PPI cable release 3 or higher. The release code is printed on the cable ("E version 3," for example, corresponds to release 3). Clamping frame Name Purpose Order no. Clamping frame for 10"/12" Touch For reinforcement of the mounting cutout for KTP1000 Basic when material is not thick enough 6AV6 671-8XS00-0AX0 Basic Panels Operating Instructions, 04/2012, A5E02421799-03 23 Overview 1.13 Commissioning the HMI device Protective foil Name Purpose Order no. Protective foil 4" Protective foil set for KTP400 Basic mono PN 6AV6 671-2EC00-0AX0 Protective foil 4" widescreen Protective foil set for KTP400 Basic color PN 6AV2124-6DJ00-0AX0 Protective foil 6" Protective foil set for KTP600 Basic 6AV6 671-2XC00-0AX0 Protective foil 10" Protective foil set for KTP1000 Basic 6AV6 671-3DC00-0AX5 Protective foil 15" Protective foil set for TP1500 Basic color PN 6AV6 574-1AD00-4EX0 Service packages 1.13 Purpose Order no. Set with 20 plastic clamps for KP300 Basic Mono PN, KP400 Basic color PN and KTP400 Basic color PN 6AV6671-8KX00-0AX2 Set with 20 aluminum mounting clamps for Basic Panels from 4" 6AV6671-8XK00-0AX0 Set of 10 power supply terminals 6AV6671-8XA00-0AX0 Commissioning the HMI device This section contains an overview of the tasks required for commissioning the HMI device. Description Section 1. Familiarize yourself with the safety instructions. Safety instructions (Page 25) 2. Prepare the HMI device for mounting. Preparations (Page 29) 3. Install the HMI device. Mounting the HMI device (Page 34) 4. Connect the equipotential bonding. Connecting the equipotential bonding circuit (Page 38) 5. Connect the power supply. Connecting the power supply (Page 39) 6. Connect a configuration PC. Connecting the configuration PC (Page 42) 7. Enable sharing for data channel on the HMI device. Enabling a data channel (Page 76) 8. Transfer a project. Starting manual transfer (Page 91) 9. After transferring the project, disconnect the HMI device from the configuration PC and connect the HMI device to the PLC. Connecting the PLC (Page 45) Basic Panels 24 Operating Instructions, 04/2012, A5E02421799-03 Safety instructions 2.1 2 General safety instructions Working on the control cabinet WARNING Open equipment The HMI device is open equipment. That means that the HMI device may only be installed in cubicles or cabinets that provide front panel access for operating the device. The cubicle or cabinet in which the HMI device is installed may only be accessed with a key or tool and only by trained, authorized personnel. Dangerous voltage Opening the cabinet will expose high voltage parts. Contact with these parts could be fatal. Always disconnect the cabinet from the mains before opening it. High frequency radiation NOTICE Unwanted operating states High-frequency radiation, for example, from cellular phones, can trigger unwanted operating states. Installation as intended WARNING Installation only in machinery that conforms to the machinery directive It is not allowed to commission the HMI device unless it has been verified that the machine in which the HMI device is to be installed complies with Directive 2006/42/EC. Basic Panels Operating Instructions, 04/2012, A5E02421799-03 25 Safety instructions 2.2 Security information 2.2 Security information Siemens offers IT security mechanisms for its portfolio of automation and drive products in order to support safe operation of the plant/machine. We recommend that you stay informed about the IT security developments for your products. For information on this topic, refer to: Industry Online Support (http://www.siemens.de/automation/csi_en_WW): You can register for a product-specific newsletter here. For the safe operation of a plant/machine, however, it is also necessary to integrate the automation components into an overall IT security concept for the entire plant/machine, which corresponds to the state-of-the-art IT technology. You can find information on this under: Industrial Security (http://www.siemens.com/industrialsecurity). Products used from other manufacturers should also be taken into account here. 2.3 Notes about usage CAUTION HMI device approved for indoor use only The HMI device may be damaged if operated outdoors. Operate the HMI device indoors only. Industrial applications The HMI device is designed for industrial applications. It conforms to the following standards: Requirements of the emission standard for industrial environments, EN 61000-6-4: 2007 ESD immunity requirements to DIN EN 61000-6-2:2005 Use in residential areas Note The HMI device is not intended for use in residential areas. Operation of an HMI device in residential areas can have a negative influence on radio/TV reception. If the HMI device is used in a residential area, you must take measures to achieve Limit Class B conforming to EN 55011 for RF interference. A suitable measure for achieving the RF interference level to Limit Class B is, for example, the use of filters in power supply lines. Individual acceptance is required. Basic Panels 26 Operating Instructions, 04/2012, A5E02421799-03 Safety instructions 2.3 Notes about usage Notes on communication NOTICE Communication errors caused by address conflict Communication errors can occur if several devices in a network share the same bus address or IP address. Make sure that your HMI device is assigned a unique address in the network. Note Updating tag values following a communication error If communication between an HMI device and PLC is interrupted, all tag values displayed on the HMI device will be replaced by a hash mark ("#"). When the communication between the HMI device and PLC is restored, all tag values will be updated immediately. The cycle time for updating the tag values begins again at "0." Ethernet communication with Basic Panels PN Basic Panels PN support the following types of communication: * PROFINET basic function for commissioning and diagnostics * Standard Ethernet communication Basic Panels Operating Instructions, 04/2012, A5E02421799-03 27 Safety instructions 2.3 Notes about usage Basic Panels 28 Operating Instructions, 04/2012, A5E02421799-03 Mounting and connecting 3.1 Preparations 3.1.1 Checking the package contents 3 Check the package content for visible signs of transport damage and for completeness. NOTICE Damaged parts Do not install parts damaged during shipment. In the case of damaged parts, contact your Siemens representative. The package content is described in section Product package (Page 22). Keep the supplied documentation in a safe place. The documentation belongs to the HMI device and is required for subsequent commissioning. 3.1.2 Checking the operating conditions Note the following aspects before installing the HMI device: 1. Familiarize yourself with the standards, approvals, EMC parameters and technical specifications for operation of the HMI device. This information is available in the following chapters: - Certificates and approvals (Page 117) - Electromagnetic compatibility (Page 118) - Information on insulation tests, protection class and degree of protection (Page 140) - Power supply (Page 131) 2. Check the mechanical and climatic ambient conditions for operation of the HMI device; see Conditions of use (Page 138). 3.1.3 Selecting a mounting position Select one of the approved mounting positions for your HMI device. The approved mounting positions are described in the following sections. Basic Panels Operating Instructions, 04/2012, A5E02421799-03 29 Mounting and connecting 3.1 Preparations Horizontal mounting position All Basic HMI devices are suitable for horizontal mounting positions. The maximum ambient temperature at the device with vertical mounting in horizontal positions is 50 C The following Basic HMI devices are also suitable for vertical mounting positions: * KTP400 Basic * KTP600 Basic The maximum ambient temperature at the device with vertical mounting in vertical positions is 40 C Angled mounting position The Basic HMI devices are selfventilating. Vertical and angled mounting is permitted in: 50 C 0 C rr rr 40 C 0 C 40 C 0 C * Mounting cabinets * Control cabinets * Switchboards * Consoles CAUTION Exceeding the ambient temperature Forced ventilation is required if the maximum permitted ambient temperature for operating the HMI device is exceeded. The HMI device can otherwise be damaged and its approvals and warranty will be void. See also Conditions of use (Page 138) Basic Panels 30 Operating Instructions, 04/2012, A5E02421799-03 Mounting and connecting 3.1 Preparations 3.1.4 Checking clearances The following clearances are required around the HMI device to ensure sufficient selfventilation: All Basic Panels x y y KTP400 Basic KTP600 Basic All dimensions in mm x z z x x y y 3.1.5 Required clearance around the HMI devices. x y z .3%DVLF .3%DVLF .73%DVLF .73%DVLF .73%DVLF 73%DVLF Making the mounting cut-out NOTICE Stability of the mounting cutout The material in the area of the mounting cutout must provide sufficient strength to guarantee the enduring and safe mounting of the HMI device. The force of the mounting clamps or operation of the device may not lead to deformation of the material in order to achieve the degrees of protection described below. Degrees of protection The degrees of protection of the HMI device can only be guaranteed if the following requirements are met: Material thickness at the mounting cutout 2 mm to 6 mm for IP65 degree of protection or Front face only Type 4X/Type 12 (indoor use only) degree of protection. The thickness is 2 mm to 4 mm for the KP300 Basic mono PN. Permitted deviation from plane at the mounting cutout: 0.5 mm This condition must be fulfilled for the mounted HMI device. Permissible surface roughness in the area of the seal: 120 m (Rz 120) A clamping frame is additionally available for the HMI device KTP1000 Basic with a material thickness < 2 mm at the mounting cutout. The frame enables you to achieve degree of protection IP65 or Front face only Type 4X/Type 12. Basic Panels Operating Instructions, 04/2012, A5E02421799-03 31 Mounting and connecting 3.1 Preparations Mounting compatibility The mounting cutouts of the Basic panels are compatible with the mounting cutouts of the following SIMATIC HMI devices: Mounting cutout for the Basic Panel Compatible to the mounting cutouts of the HMI device KP400 Basic OP77A, OP77B KTP400 Basic TP 177B 4" KTP600 Basic TP 177 A, TP 177B 6", TP 177micro KTP1000 Basic MP 277 10" Touch, MP 377 12" Touch TP1500 Basic MP 377 15" Touch, Thin Client 15" Touch Dimensions of the mounting cutout Dimensions of the mounting cutout for the basic HMI devices in horizontal mounting position: w w h +1 0 h +1 0 .3%DVLF .3%DVLF .73%DVLF .73%DVLF .73%DVLF 73%DVLF Dimensions of the mounting cutout for the basic HMI devices in vertical mounting position: +1 0 h .73%DVLF .73%DVLF w +1 0 All dimensions in mm See also Accessories (Page 23) Basic Panels 32 Operating Instructions, 04/2012, A5E02421799-03 Mounting and connecting 3.1 Preparations 3.1.6 Labeling the function keys The KP300 Basic has no function keys that can be labeled. Note Do not write on the keyboard to label the function keys. Any printable and writable foil can be used as labeling strip. The permitted thickness of the labeling strip is 0.15 mm. Paper labeling strips are inappropriate. 1. Edit the template on the PC. A The template is available in the "CD_3\Documents\ \Slides" directory on the WinCC/WinCC flexible DVD or on the Internet at: PLQ Downloads for Basic Panels (http://support.automation.siemens.c om/WW/view/en/28426379/133100) 2. Print the edited template on foil. 3. Apply a fixing spray film to the labeling strips. 4. Wait approx. 5 minutes until the fixing spray is dry and smear-proof. 5. Cut out the labeling strip. 6. Cut off the corners of the labeling strips at an angle of 45 to make it easier to insert them. 7. Slide the labeling strips into the slot up to the end of the guide. The labeling strips will protrude approximately 3 cm out of the guide. The template dimensions for the labeling strips are designed so that the labeling is correctly placed for the function keys. It is not necessary to secure the labeling strip. .7 3 .3 Basic Panels Operating Instructions, 04/2012, A5E02421799-03 33 Mounting and connecting 3.2 Mounting the HMI device 3.2 Mounting the HMI device Required tools and accessories Slotted screwdriver, size 2 Mounting clamp type For HMI device Aluminum mounting clamps KTP400 Basic mono 5 KTP600 Basic 6 KTP1000 Basic 12 Plastic mounting clamps Required quantity TP1500 Basic: 14 KP300 Basic 4 KP400 Basic 7 KTP400 Basic color 5 Inserting the HMI device 1. If necessary, insert the mounting seal in the groove on the back of the HMI device front panel. ,3 Make sure that the mounting seal is not twisted. A correctly inserted mounting seal is required to ensure IP65 degree of protection. 2. Insert the HMI device into the mounting cutout from the front. Ensure that the protruding labeling strips are not caught between the mounting cutout and HMI device. Basic Panels 34 Operating Instructions, 04/2012, A5E02421799-03 Mounting and connecting 3.2 Mounting the HMI device Securing the HMI device with aluminum mounting clamps 1. Insert the first clamp at the first position of the cutouts on the back of the HMI device. 0.2 Nm Set the clamp positions for your HMI device to match those of the figures in the following table row. 2. Secure the clamps using a size 2 screwdriver. The maximum permitted torque is 0.2 N/m. 3. Repeat steps 1 to 2 for all mounting clamps required to secure your HMI device. .7 3 .73 %DVLFPRQR .73%DVLF 73%DVLF .73%DVLF Basic Panels Operating Instructions, 04/2012, A5E02421799-03 35 Mounting and connecting 3.3 Connecting the HMI device Securing the HMI device with plastic mounting clamps 1. If mounting clamps and grub screws are available separately in the accessories bag, insert a grub screw into the mounting clamp bore hole and turn it several times. 2. Place the first mounting clamp into the corresponding cutout. 3. Secure the clamps using a size 2 screwdriver. The maximum permitted torque is 0.2 N/m. 0.2 Nm .7 3 4. Repeat steps 1 to 3 for all mounting clamps required to secure your HMI device. 3.3 Connecting the HMI device 3.3.1 Connection sequence Required tools and accessories Before beginning the connection of the HMI device, have the following tools and accessories at hand: Slotted screwdriver, size 2 Phillips screwdriver, size 3 Basic Panels 36 Operating Instructions, 04/2012, A5E02421799-03 Mounting and connecting 3.3 Connecting the HMI device Torx screwdriver, size TX20 Crimp pliers Power supply terminal 24 VDC with sufficient amperage. See Specifications (Page 131) Procedure Keep to the following sequence of tasks when connecting the HMI device: 1. Connecting the equipotential bonding circuit (Page 38) 2. Connecting the power supply (Page 39) 3. Connecting the configuration PC (Page 42) 4. Connecting the PLC (Page 45) NOTICE Strain relief Contacts can be broken or wires can be torn off if cables are not provided adequate strain relief. Provide adequate strain relief for all cables. See also Securing the cables (Page 50) Basic Panels Operating Instructions, 04/2012, A5E02421799-03 37 Mounting and connecting 3.3 Connecting the HMI device 3.3.2 Connecting the equipotential bonding circuit Differences in electrical potential Differences in electrical potential can develop between spatially separated plant components. Such electrical potential differences can lead to high equalizing currents over the data cables and therefore to the destruction of their interfaces. Equalizing currents can develop if the cable shielding is terminated at both ends and grounded to different plant parts. Differences in potential may develop when a system is connected to different mains supplies. General requirements for equipotential bonding Differences in potential must be reduced by means of equipotential bonding in order to ensure trouble-free operation of the relevant components of the electronic system. The following must therefore be observed when installing the equipotential bonding circuit: The effectiveness of equipotential bonding increases as the impedance of the equipotential bonding conductor decreases or as its cross-section increases. If two plant parts are interconnected by means of shielded data cables and their shielding is bonded at both ends to the grounding/protective conductor, the impedance of the additionally installed equipotential bonding cable must not exceed 10% of the shielding impedance. The cross-section of an equipotential bonding conductor must be capable of handling the maximum equalizing current. The best practical results for equipotential bonding between two cabinets have been achieved with a minimum conductor cross-section of 16 mm. Use equipotential bonding conductors made of copper or galvanized steel. Establish a large surface contact between the equipotential bonding conductors and the grounding/protective conductor and protect these from corrosion. Clamp the shielding of the data cable on the HMI device flush and near the equipotential rail using suitable cable clamps. Route the equipotential bonding conductor and data cables in parallel and with minimum clearance between these. NOTICE Equipotential bonding cable Cable shielding is not suitable for equipotential bonding. Always use the prescribed equipotential bonding conductors. The cross-section of the equipotential bonding conductor must not be less than 16 mm. Always use cables with an adequate crosssection when installing MPI and PROFIBUS DP networks. The interface modules may otherwise be damaged or destroyed. Basic Panels 38 Operating Instructions, 04/2012, A5E02421799-03 Mounting and connecting 3.3 Connecting the HMI device Procedure 1. Interconnect functional ground of the HMI device with an grounding cable, cross-section 4 mm2. .7 3 2. Connect the grounding cable of the HMI device to the equipotential bonding rail. PPt PPt PPt 352),%86 352),1(7 3.3.3 Connecting the power supply Stripping the cable 6m m Use power supply cables with a maximum cross-section of 1.5 mm2. 1. Strip the ends of two power supply cables to a length of 6 mm. 2. Attach cable sleeves to the bare cable ends. 3. Fix the cable sleeve onto the cable ends using the crimp pliers. Basic Panels Operating Instructions, 04/2012, A5E02421799-03 39 Mounting and connecting 3.3 Connecting the HMI device Procedure CAUTION 24 VDC only An incorrectly dimensioned power supply can lead to destruction of the HMI device. Use a 24 VDC power supply with adequate amperage; see Specifications (Page 131). 1. Insert the two power cables into the mains terminal and secure them with a slotted screwdriver. 2. Connect the HMI device to the mains terminal. .7 3 3. Switch off the power supply. 4. Insert the two remaining cable ends into the power terminals and secure them with the slotted screwdriver. Ensure correct polarity. 2)) M L+ Basic Panels 40 Operating Instructions, 04/2012, A5E02421799-03 Mounting and connecting 3.3 Connecting the HMI device 3.3.4 Connecting a programming device A programming device provides the following options: Transferring projects. Transferring device images. Connecting a programming device to a Basic Panel DP Note A programming device cannot be used to reset the HMI device to factory settings. 1. Shut down the HMI device. Make sure that the DIP switch on the rear panel of the HMI device is in the position shown. 21 2)) RS 422/ 485 PROFIBUS 2. Connect an RS 485 PROFIBUS connector to the HMI device. 3. Connect an RS 485 PROFIBUS connector to the programming device. RS 485 PG Basic Panels Operating Instructions, 04/2012, A5E02421799-03 41 Mounting and connecting 3.3 Connecting the HMI device 3.3.5 Connecting the configuration PC A configuring PC provides the following options: Transferring projects. Transferring device images. Resetting HMI device to factory settings. Connecting a configuring PC to a Basic Panel DP 1. Shut down the HMI device. 2. Connect the RS 485 connector of the PC/PPI cable to the HMI device. 2)) RS422/485 3. Connect the RS 232 connector of the PC/PPI cable to the configuring PC. You can also use the USB/PPI cable from the accessories instead of the PC/PPI cable. Serial RS 232 You can find ordering information in the Accessories (Page 23) section. PC Basic Panels 42 Operating Instructions, 04/2012, A5E02421799-03 Mounting and connecting 3.3 Connecting the HMI device Configuring the PC/PPI cable Configure the transmission speed using the DIP switches of the PC/PPI cable if using the PC/PPI cable to interconnect the HMI device with the configuring PC. Note Set a lower bit rate if the connection is lost during the operating system update. If you use a higher bit rate, you must use the PC/PPI cable release 3 or higher. The version code is printed on the cable ("E stand 3," for example, corresponds to release 3). Set the DIP switches 1 to 3 to the same value as in WinCC flexible or WinCC. DIP switches 4 to 8 must be set to "0". In the figure, the bit rate is set to 115.2 kbps. You can set the following bit rates: Bit rate in kbps DIP switch 1 DIP switch 2 DIP switch 3 115.2 1 1 0 57.6 1 1 1 38.4 0 0 0 19.2 0 0 1 9.6 0 1 0 4.8 0 1 1 2.4 1 0 0 1.2 1 0 1 Basic Panels Operating Instructions, 04/2012, A5E02421799-03 43 Mounting and connecting 3.3 Connecting the HMI device Connecting a configuring PC to a Basic Panel PN CAUTION Data network security for communication via Ethernet With Ethernet-based communication via PROFINET, the end user is himself responsible for the security of his data network; the proper functioning of the data network cannot be guaranteed in all circumstances, for example in the case of target attacks leading to an overloading of the device. NOTICE RJ45 plug connector with 180 output required The connection of the Basic Panels PN to the HMI device requires the RJ45 plug connector "IE FC RJ45 Plug 2 x 2". You can find ordering information in the Accessories (Page 23) section. Use a standard CAT-5 Ethernet cable to connect the configuring PC. 1. Shut down the HMI device. 2. Connect one RJ45 connector of the LAN cable to the HMI device. 2)) PROFINET (LAN) 3. Connect the other RJ45 connector of the LAN cable to the configuring PC. LAN LAN PC See also Data transmission options (Page 91) Basic Panels 44 Operating Instructions, 04/2012, A5E02421799-03 Mounting and connecting 3.3 Connecting the HMI device 3.3.6 Connecting the PLC If the HMI device contains an operating system and an executable project, connect the HMI device to the PLC. Note Note the following when connecting the PLC to a panel: * Lay the data lines parallel to the equipotential bonding conductors * Connect the shields of the data lines to the ground Connecting a PLC to a Basic Panel DP You can connect Basic Panels DP via the RS 422/RS 485 interface to the following SIMATIC PLCs: RS 422/485 PROFIBUS DP SIMATIC S7-200 SIMATIC S7-300/400 RS 422/485 Serial RS 232 * SIMATIC S7-200 * SIMATIC S7-300/400 * SIMATIC S7-1200 You can interconnect Basic Panels DP with the following PLCs via converter (from the accessories): * Modicon Modbus * Allen Bradley DF1 For ordering information for the converters, refer to chapter Accessories (Page 23). If using the RS 422/RS 485 port, read the notes on configuration in the following section. Third party PLC Basic Panels Operating Instructions, 04/2012, A5E02421799-03 45 Mounting and connecting 3.3 Connecting the HMI device Configuring an RS422/RS485 port A DIP switch for the configuration of the RS422/RS485 interface is located on the back of the HMI device. The DIP switch is set at the factory to enable communication with the SIMATIC PLC via RS 485. Note Note the diagrams of DIP switch settings on the rear panel of the HMI device. The following table shows the DIP switch settings. The send and receive direction is toggled internally using the RTS signal. Communication DP/MPI/PPI Switch setting 21 Meaning No RTS signal on connector, for data exchange between the SIMATIC PLC and the HMI device (factory state) RTS signal on pin 4, same as PLC, for example, for commissioning 21 RTS signal on pin 9, same as for a programming device, for example, for commissioning 21 RS 422/RS 485 RS 422/RS 485 interface is active, for example, for connecting PLCs of other manufacturers 21 Basic Panels 46 Operating Instructions, 04/2012, A5E02421799-03 Mounting and connecting 3.3 Connecting the HMI device Connecting the PLC to a Basic Panel PN CAUTION Data network security for communication via Ethernet With Ethernet-based communication via PROFINET, the end user is himself responsible for the security of his data network; the proper functioning of the data network cannot be guaranteed in all circumstances, for example in the case of target attacks leading to an overloading of the device. NOTICE RJ45 plug connector with 180 output required The connection of the Basic Panels PN to the HMI device requires the RJ45 plug connector "IE FC RJ45 Plug 2 x 2". You can find ordering information in the Accessories (Page 23) section. Basic Panels PN can be connected to the following SIMATIC PLCs: * SIMATIC S7-200 * SIMATIC S7-300/400 SIMATIC S7 with PROFINET interface The connection is set up via PROFINET/LAN. * PROFINET (LAN) PROFINET PROFINET LAN SIMATIC S7-200 SIMATIC S7-300/400 SIMATIC S7-1200 See also Connecting the equipotential bonding circuit (Page 38) Basic Panels Operating Instructions, 04/2012, A5E02421799-03 47 Mounting and connecting 3.4 Switching on and testing the HMI device 3.4 Switching on and testing the HMI device Switching on the HMI device. Switching on the power supply. The screen lights up after power is switched on. A progress bar is displayed during startup. If the HMI device fails to start, you have probably crossed the wires on the power supply terminal. Check the connected wires and change their connection. .7 3 21 M L+ Basic Panels 48 Operating Instructions, 04/2012, A5E02421799-03 Mounting and connecting 3.4 Switching on and testing the HMI device The Loader opens after the operating system has started. Touch devices: You operate the loader via the buttons on the touch screen Key devices: You use the cursor keys to operate the loader menu. You use the key to execute a menu command or switch to a submenu. * Press the "Transfer" button or use the "Transfer" menu command to set the HMI device to "Transfer" mode. The transfer mode can only be activated when at least one data channel has been enabled for the transfer. * Press the "Start" button or use the "Start" menu command to start the project on the HMI device. If you do not perform an operation, the project on the HMI device will automatically start after a delay. * Transfer Start Info/Settings Press the "Control Panel" button or use the "Info/Settings" menu command to open the Control Panel of the HMI device. You can change various settings in the Control Panel, for example, the transfer settings. Shutting down the HMI Device 1. Close any active projects on the HMI device. 2. Shut down the HMI device. You have the following shutdown options: - Switch off the power supply. - Remove the power supply terminal from the HMI device. Basic Panels Operating Instructions, 04/2012, A5E02421799-03 49 Mounting and connecting 3.5 Securing the cables 3.5 Securing the cables The following HMI devices come equipped with a fixing element on the back for strain relief: KTP1000 Basic DP KTP1000 Basic PN TP1500 Basic After the power-on test, use a cable tie to secure the connected cables to the marked fixing element in order to provide strain relief. On the back of the HMI device KP400 Basic color PN, there are openings for leading in two cable ties for strain relief of the power supply cable and LAN cable. Basic Panels 50 Operating Instructions, 04/2012, A5E02421799-03 Operating the device 4.1 Operating touch devices 4.1.1 Overview 4 Most Basic HMI devices feature a touch screen. Certain Basic HMI devices feature function keys. Use the touch screen and function keys to operate the Control Panel or the project running on your HMI device. DANGER Incorrect operation A project can contain certain operations that require in-depth knowledge about the specific plant on the part of the operator. Ensure that only trained professional personnel operate the plant. Operating the touch screen CAUTION Damage to the touch screen Pointed or sharp objects can damage the plastic surface of the touch screen. Operate the touch screen only with your fingers or with a touch pen. Triggering unintended actions Touching several operating elements at the same time can trigger unintended actions. Touch only one operating element on the screen at a time. Operating elements are touch-sensitive symbols on the screen of the HMI device. Basic Panels Operating Instructions, 04/2012, A5E02421799-03 51 Operating the device 4.1 Operating touch devices They are basically operated in the same way as mechanical keys. You activate operating elements by touching them with your finger. Note The HMI device returns a visual feedback as soon as it detects that an operating element has been touched. The visual feedback is independent of any communication with the PLC. The visual feedback signal therefore does not indicate whether or not the relevant action is actually executed. Examples of operating elements: Buttons Buttons can assume the following states: "Untouched" "Touched" Invisible buttons The focus of invisible buttons is by default not indicated following selection. No optical operation feedback is provided in this case. The configuration engineer may, however, configure invisible buttons so that their outline appears as lines when touched. This outline remains visible until you select another operating element. I/O fields A screen keyboard appears as visual feedback after you touched an I/O field, for example, to enter a password. Depending on the HMI device and the configured operating element, the system displays different screen keyboards for entering numerical or alphanumerical values. The screen keyboard is automatically hidden again when input is complete. Note Description of all operating elements A comprehensive description of all operating elements for your HMI device is provided in "Display and operating elements" section of the WinCC flexible and WinCC Online Help. Basic Panels 52 Operating Instructions, 04/2012, A5E02421799-03 Operating the device 4.1 Operating touch devices Operating function keys The function keys can be assigned global or local functions: Function keys with global function assignment A function key with global function assignment always triggers the same action on the HMI device or in the PLC, regardless of the currently displayed screen. An example of such an action is the activation of a screen, or the closing of an alarm window. Function keys with local function assignment A function key with local function assignment is screen-specific and is therefore only effective within the active screen. The function assigned to a function key can vary from screen to screen. The function key can be assigned only a single function, either global or local, within a screen. Local function assignments override global function assignments. 4.1.2 General functions of the screen keyboard The following keys are available on the screen keyboard of all Basic HMI devices with touch functionality: Cursor left Cursor right Delete character Cancel input Confirm input Displaying infotext. This key only appears when an infotext has been configured for the operating element. Basic Panels Operating Instructions, 04/2012, A5E02421799-03 53 Operating the device 4.1 Operating touch devices 4.1.3 Entering data on the KTP400 Basic Due to the small display, the screen keyboard and the input concept of the KTP400 Basic differs compared to other Basic HMI devices. 7H[W 7H[W 681 ,FRQV 1XPEHUV 681 681 The screen keyboard appears on the HMI device touch screen when you touch an operating element that requires input. The screen keyboard of the KTP400 BASIC features four views. You can change the view while making entries using the buttons in the fourth row of the screen keyboard: Key Changes to the view Entering text, characters "A" to "M" Entering text, characters "N" to "Z" Entering numbers, "0" to "9," signed or unsigned and with or without decimal places Entering special characters Entering text, shift to lower case letters Basic Panels 54 Operating Instructions, 04/2012, A5E02421799-03 Operating the device 4.1 Operating touch devices Note Job mailbox has no effect PLC job 51 "Select screen" has no effect while the screen keyboard is open. Key assignment The alphanumerical screen keyboard layout is monolingual. A language change within the project has no effect on the layout of the alphanumerical screen keyboard. Entering alphanumerical values 1. Touch the desired operating element on the screen. The alphanumerical screen keyboard opens. 2. Enter the value. Depending on the settings, the HMI device outputs an audible signal. You can change the view of the screen keyboard using the keys and . Use the key to enter lower-case letters. 3. Press key to confirm your entries, or cancel them with . Either action closes the screen keyboard. Basic Panels Operating Instructions, 04/2012, A5E02421799-03 55 Operating the device 4.1 Operating touch devices Entering numerical values 1. Touch the desired operating element on the screen. The numerical screen keyboard opens. 2. Enter the value. Depending on the settings, the HMI device outputs an audible signal. You can change the view of the screen keyboard for entering numbers with hexadecimal notation using the and keys. 3. Press key to confirm your entries, or cancel them with . Either action closes the screen keyboard. Checking numerical value limits Tags can be assigned limit values. Any entry of a value outside this limit is rejected. If an alarm view is configured, a system event is triggered and the original value is displayed again. Decimal places of numerical values The configuration engineer can define the number of decimal places for a numerical text box. The number of decimal places is checked when you enter a value in this type of I/O field. Decimal places that exceed the limit are ignored. Unused decimal places are padded with "0" entries. Basic Panels 56 Operating Instructions, 04/2012, A5E02421799-03 Operating the device 4.1 Operating touch devices 4.1.4 Entering data on the KTP600 Basic, KTP1000 Basic , TP1500 Basic Alphanumerical screen keyboard The screen keyboard appears on the HMI device touch screen when you touch an operating element that requires input. 7H[W 1XPEHUV 681 )))) Note Job mailbox has no effect PLC job 51 "Select screen" has no effect while the screen keyboard is open. Key assignment The alphanumerical screen keyboard layout is monolingual. A language change within the project has no effect on the layout of the alphanumerical screen keyboard. Entering alphanumerical values 1. Touch the desired operating element on the screen. The alphanumerical screen keyboard opens. 2. Enter the value. Depending on the settings, the HMI device outputs an audible signal. Use the key to enter lower-case letters. 3. Press key to confirm your entries, or cancel them with . Either action closes the screen keyboard. Basic Panels Operating Instructions, 04/2012, A5E02421799-03 57 Operating the device 4.1 Operating touch devices Entering numerical values 1. Touch the desired operating element on the screen. The numerical screen keyboard opens. 2. Enter the value. Depending on the settings, the HMI device outputs an audible signal. 3. Press key to confirm your entries, or cancel them with . Either action closes the screen keyboard. Checking numerical value limits Tags can be assigned limit values. Any entry of a value outside this limit is rejected. If an alarm view is configured, a system event is triggered and the original value is displayed again. Decimal places of numerical values The configuration engineer can define the number of decimal places for a numerical text box. The number of decimal places is checked when you enter a value in this type of I/O field. Decimal places that exceed the limit are ignored. Unused decimal places are padded with "0" entries. Basic Panels 58 Operating Instructions, 04/2012, A5E02421799-03 Operating the device 4.2 Operating KP300 Basic 4.2 Operating KP300 Basic 4.2.1 Overview The KP300 Basic comes equipped with system keys. The system keys are as follows: Control keys Function keys with integrated alphanumeric keys Control keys The following table shows the function and effect of the control keys of the HMI device: Key Function Effect Moving the cursor Operating elements: Activates the next operating element in the respective direction Input: Moves the cursor in the respective direction List: Selects the next list entry. (17(5 Confirming or activating Menu: Executes the selected command. Input: Confirms and ends the entry. List: Activates the operation. Cancels the action (6& Value entry: Restores the original value. Window: Closes the window without applying a change. Help: Closes the Help and returns to the previous view. Acknowledge alarm Depending on the configuration, acknowledges the currently displayed or selected message or all messages of an acknowledgment group. Delete characters Deletes the character at the cursor position. The following characters are moved one position to the left. Displaying infotext Shows the selected configured infotext for the selected operating element. No Help is displayed if no infotext is configured. Toggle between upper-case and lower-case Toggles the text entry between upper-case and lower-case. The subsequent characters are then written either in upper or lower case. Activate next operating element Activates the next operating element within the configured TAB order within the project. $&. (6& '(/ US +(/3 ) nopUS T 7$% Vh T 7$% Vh Basic Panels Operating Instructions, 04/2012, A5E02421799-03 59 Operating the device 4.2 Operating KP300 Basic Operating function keys The function keys can be assigned global or local functions: Function keys with global function assignment A function key with global function assignment always triggers the same action on the HMI device or in the PLC, regardless of the currently displayed screen. An example of such an action is the activation of a screen, or the closing of an alarm window. Function keys with local function assignment A function key with local function assignment is screen-specific and is therefore only effective within the active screen. The function assigned to a function key can vary from screen to screen. The function key can be assigned only a single function, either global or local, within a screen. Local function assignments override global function assignments. NOTICE Function keys are disabled during keyboard input When you enter values using the keyboard, the function key assignment is disabled. Take this information into account in your configuration. Use the integrated alphanumeric keys for data input as described in the subsection below. 4.2.2 Entering data on the KP300 Basic Introduction The function keys of the KP300 Basic have the same operating concept as a cell phone keypad. Each function key assigned with several letters and symbols of the alphabet and each is assigned a number. The available ones are displayed in a menu on the display when you enter values. The selection in the menu moves one position to the right every time the function key is pressed. At the end, the selction resumes again at the start. The numerical and alphanumerical assignment alway has the following order for value entry: 1. Letters, for example JKL 2. Numers, for example 5 3. Special characters and umlauts (optional) Basic Panels 60 Operating Instructions, 04/2012, A5E02421799-03 Operating the device 4.2 Operating KP300 Basic The following figure shows the assignment using the "F5" function key as an example. ) -./ Number assignment; automatically active when you enter numerical values Function key assignment; active by default If you change to editing mode in the Control Panel or project with , the function assignment is disabled. Instead, the numerical and/or alphanumerical assignment is active. A message indicating that the function keys are disabled appears at the same time. Letter assignment; automatically active when you enter alphanumerical values. The numerical assignment is available as well. When you enter hexadecimal values, the alphanumerical assignment from "A" to "F" and the numerical assignment are active. On the KP300 Basic, you navigate either in the menu or operate the current project. Operating Menus Proceed as follows: 1. Use the cursor keys to navigate within the menu of the KP300 Basic. The selection moves to the corresponding menu entry. 2. Press to execute a menu command. The next menu level is displayed. 3. If the menu level contains an text box, use the function keys to enter the appropriate value. 4. If the menu level contains a list: - Press to activate the operation of the list. - Use the cursor keys to move between list entries. - Press to execute a list entry. 5. To enter a value in the menu: - Press to apply a value. - Press to discard a value or return to a higher-level menu. Basic Panels Operating Instructions, 04/2012, A5E02421799-03 61 Operating the device 4.2 Operating KP300 Basic Operating a project Proceed as follows: 1. To navigate between operating elements: - Press to navigate within a configured TAB order. - Use the cursor keys to navigate freely between operating elements. The operating element is selected. 2. Press to activate the operation of a selected operating element. - Depending on the operating element, enter values or select them from the available list entries. 3. To close the operation of an operating element: - Press to apply any changes. - Press to discard any changes. Entering numbers and characters The function keys are used to enter numbers and characters. Proceed as follows: 1. Activate the operation of the operating element. 2. Press the respective key repeatedly until the character you want appears on the screen. The assignment of the function keys to letters and numbers can be restricted based on the format of the operating element. The desired character is applied in about one second or immediately after pressing a different button. 3. To navigate within the given character string, use the cursor keys. 4. Press to apply the entry. Checking numerical value limits Tags can be assigned limit values. Any entry of a value outside this limit is rejected. If an alarm view is configured, a system alarm is triggered and the original value is displayed again. Basic Panels 62 Operating Instructions, 04/2012, A5E02421799-03 Operating the device 4.3 Operating KP400 Basic Decimal places of numerical values The configuration engineer can define the number of decimal places for a numerical text box. The number of decimal places is checked when you enter a value in this type of I/O field. Decimal places that exceed the limit are ignored. Unused decimal places are padded with "0" entries. 4.3 Operating KP400 Basic 4.3.1 Overview Alphanumeric assignment of keys The following table shows the alphanumeric assignment of the data input keys. Key Alphanumeric assignment 1 ._\@#?!':;()^~{}"|1 2 ABCAA2 3 DEFE3 4 GHI4 5 JKL5 6 MNOO6 7 PRQRS7 for upper case letters, pqrs7 for lower case letters 8 TUVU8 9 WXYZ9 0 +-*/=0 . ., General functions You initiate functions either with keys or keyboard shortcuts. With keyboard shortcuts, hold the first key down. Then press the second key. Basic Panels Operating Instructions, 04/2012, A5E02421799-03 63 Operating the device 4.3 Operating KP400 Basic The following table shows the functions that are available both in the Control Panel and in the project: Key or key combination Function Switches between upper and lower case Deletes the character left of cursor. Moves to the next operating element in the TAB order. Moves to the previous operating element in the TAB order. Deletes the character right of cursor. The following characters are moved one position to the left. Inserts a space. Cancels an action, e.g., cancel an input and close the dialog Value entry: Restores the original value. Window: Closes the window without applying a change. Help: Closes the Help and returns to the previous view. Executes a command, e.g.: * Operating buttons * Open dialog or select menu command * Check value, apply value after successful check and close the dialog Operating elements: Activates the next operating element in the respective direction Input: Moves the cursor in the respective direction List: Selects the next list entry. Within a text box: Switches to the next or previous numerical or alphanumerical character Within a list: Selects the next list entry Move the cursor or selection one screen up. Move the cursor or selection one screen down. Switches to another key mapping. Basic Panels 64 Operating Instructions, 04/2012, A5E02421799-03 Operating the device 4.3 Operating KP400 Basic Operating the Control Panel and dialogs The following table shows additional key functions when operating the Control Panel and the associated dialogs. Key or key combination Function On tab level: Switches between tabs Within a text box: Positions the cursor Activates tab level, text boxes, buttons or options from top to bottom or from left to right Activates tab level, text boxes, buttons or options from bottom to top or from right to left Selects or clears check boxes as well as the element of a radio button Operating a project The following table shows additional key functions when operating an ongoing project. Key or key combination Function Acknowledges the currently displayed error alarm or all the alarms of an alarm group as group acknowledgment. Calls up the configured infotext for an operating element. Operating function keys The function keys can be assigned global or local functions: Function keys with global function assignment A function key with global function assignment always triggers the same action on the HMI device or in the PLC, regardless of the currently displayed screen. An example of such an action is the activation of a screen, or the closing of an alarm window. Function keys with local function assignment A function key with local function assignment is screen-specific and is therefore only effective within the active screen. The function assigned to a function key can vary from screen to screen. The function key can be assigned only a single function, either global or local, within a screen. Local function assignments override global function assignments. Basic Panels Operating Instructions, 04/2012, A5E02421799-03 65 Operating the device 4.3 Operating KP400 Basic 4.3.2 Entering data on the KP400 Basic Data input on an HMI device is similar to operating the keys on a cell phone. Each key has several functions. When you press a data input key for long enough, the number is automatically inserted. The following figure is an example for input of an alphanumeric value. Requirement The cursor must be in the text box. Procedure Proceed as follows: 1. Press the respective key repeatedly until the desired character is selected in the preview. The allocation of keys may be restricted to letters or numbers, depending on the context. The desired character is applied in about one second or immediately after pressing a different button. 2. To toggle between upper and a lower case, press . All subsequent characters are written either in upper or lower case. 3. To navigate within the given character string, use the cursor keys. 4. If you enter values in the Control Panel, you can apply them with or : - : Closes the dialog. - : Navigates to the next operating element within the dialog. 5. If you enter values in the project, you can apply them with . Basic Panels 66 Operating Instructions, 04/2012, A5E02421799-03 5 Configuring the HMI device 5.1 Configuring devices with graphical Control Panel 5.1.1 Opening the Control Panel With the exception of the KP300 Basic mono PN, all Basic Panels have a graphic Control Panel. Open the Control Panel by pressing the "Control Panel" button of the Loader. Configure your HMI device in the Control Panel. You can make the following settings: %DVLF3DQHOV'3 * Communication settings * Settings for operation * Password protection * Transfer settings * Screen saver * Acoustic signals The "MPI / Profibus Settings" is only available on Basic Panels DP. The "Profinet" is only available on Basic Panels PN. The "Sound Settings" symbol is only available on devices with sound reproduction. %DVLF3DQHOV31 Basic Panels Operating Instructions, 04/2012, A5E02421799-03 67 Configuring the HMI device 5.1 Configuring devices with graphical Control Panel Protecting the Control Panel with a password You can protect the Control Panel against unauthorized operation. You can read the settings in the Control Panel without having entered a password, however, you are not allowed to edit the settings. This prevents inadvertent operations and increases security for the plant or machine because the settings cannot be edited. NOTICE If the password is no longer available for the Control Panel, you first have to update the operating system before you can make any changes in the Control Panel. All data on the HMI device is overwritten when you update the operating system. 5.1.2 Overview The following table shows the functions available in the Control Panel for configuring your HMI device. Individual functions may be hidden, depending on the device type and device configuration. Symbol Function Changing MPI/DP settings (Page 69) Changing the network configuration (Page 70) Time server configuration (Page 71) Changing monitor settings (Page 72) Displaying information about the HMI device (Page 73) Calibrating the touch screen (Page 74) Displaying licensing information for the HMI device (Page 75) Changing password settings (Page 78) Enabling a data channel (Page 76) Setting the Screen Saver (Page 79) Setting acoustic signals (Page 79) Basic Panels 68 Operating Instructions, 04/2012, A5E02421799-03 Configuring the HMI device 5.1 Configuring devices with graphical Control Panel 5.1.3 Changing MPI/DP settings Note The settings for MPI or PROFIBUS DP communication are defined in the HMI device project. Edit the transfer settings only in the following situations: * Initial transfer of a project. * Changes made to the project are activated at a later time. 1. Press "MPI / Profibus Settings" to open the "MPI / Profibus Settings" dialog. 2. Deactivate the "Panel is the only master on the bus" check box if additional masters are connected to the bus. A A 3. Enter the bus address for the HMI device in the "Address" text box. The bus address must be unique within the MPI/PROFIBUS DP network. Enter the time limit for PROFIBUS communication in the "Time-out" text box. Valid values are 1 s, 10 s and 100 s. 4. Select the transmission rate from the "Transmission Rate" text box. Enter the highest station address on the bus in the "Highest Station" text box. Valid range of values: 1 to 126. Select the profile from the "Profile" selection box. Press the "Bus Parameters..." button to view the PROFIBUS profile data. 5. Close the dialog and save your entries with "OK". Basic Panels Operating Instructions, 04/2012, A5E02421799-03 69 Configuring the HMI device 5.1 Configuring devices with graphical Control Panel 5.1.4 Changing the network configuration NOTICE Communication errors caused by IP address conflicts Communication errors can occur if several devices in a network share the same IP address. Assign each HMI device an IP address that is unique within the network. 1. Press "Profinet" to open the "Profinet Settings" dialog. 2. Choose either automatic address assignment via DHCP, or user-specific address assignment. 3. If assigning a user-specific address, use the screen keyboard to enter valid values in the "IP Address", "Subnet Mask" text boxes and if applicable in the "Default Gateway" text box. 4. Open the "Mode" tab. A 5. Enter the transmission rate for the PROFINET network in the "Speed" text box. Valid values are 10 Mbps and 100 Mbps. 6. Select "Half duplex" or "Full duplex" as the connection mode. 7. If the "Auto Negotiation" check box is selected, the transmission type and transmission rate in the PROFINET network will be automatically detected and set. A 8. If the "Deactivate LLDP" check box is selected, the HMI device exchanges no information with other HMI devices. 9. Open the "Device" tab. 10. Enter a network name for your HMI device. The name must meet the following conditions. A - Maximum length: 240 characters - Characters "a" to "z", numbers "0" to "9"; allow special characters: "-" and "." - Invalid syntax: "n.n.n.n" (n=0 to 999) and "port-yxz" (x, y, z =0 to 9) 11. Close the dialog and save your entries with "OK". Basic Panels 70 Operating Instructions, 04/2012, A5E02421799-03 Configuring the HMI device 5.1 Configuring devices with graphical Control Panel 5.1.5 Time server configuration The HMI device has an unbuffered realtime clock. The realtime clock is set either using the configuration or using a time server. To fetch the time-of-day of the HMI device from a time server, specify up to four different time servers. The time-of-day is synchronized via the "Network Time Protocol" (NTP). Also specify the update cycle of the time-of-day and, if necessary, a time shift. Update cycle and time shift are valid for all configured time servers. You can test the availability of each time server separately. 1. Press "Profinet" to open the "Profinet Settings" dialog. 2. Open the "NTP" tab. 3. At "Update Rate", enter the time duration in seconds according to which the time-of-day will be synchronized. Value range: 10 to 86400 (1 day) 4. If required, use the "-" and "+" buttons to set the time shift in "hh:mm". A Value range: -24:00 to +24:00 5. Press "Configure" to open the configuration of the time server. 6. Enter the IP address of the time server at "IP Address". 7. Use the "Test" button to test the availability of the time server. The connection is established. If the connection was successfully established, date and time are displayed. Any value set at "Time shift" will not be taken into consideration. 8. Close the dialog and save your entries with "OK". 9. Close the dialog and save your entries with "OK". A Basic Panels Operating Instructions, 04/2012, A5E02421799-03 71 Configuring the HMI device 5.1 Configuring devices with graphical Control Panel 5.1.6 Changing monitor settings NOTICE Orientation of the screen for KTP400 Basic and KTP600 Basic The screen orientation is defined by the configuration engineer in the course of project creation. The appropriate screen orientation is set automatically when you transfer the project to the HMI device. Do not make any changes to the screen orientation if a project exists on the HMI device. The screen content may otherwise be truncated. 1. Press "OP" to open the "OP Properties" dialog. 2. Basic Panels Color (except KTP600 Basic color): Press the "UP" and "DOWN" buttons to adjust the screen brightness. Basic Panels mono: Press the "UP" and "DOWN" buttons to adjust the screen contrast. 3. KTP400 Basic and KTP600 Basic only: KTP400 Basic KTP600 Basic A Select the screen orientation: - "Landscape" for landscape - "Portrait" for portrait 4. Set the delay time in the "Delay time" text box. The delay time in seconds defines the waiting time expiring between the appearance of the loader and the start of the project. Valid range of values: 0 s to 60 s. 5. Close the dialog and save your entries with "OK". Note Immediate start of the project with a delay time of 0 seconds The project starts immediately if a delay time of 0 seconds is set. It is then no longer possible to call the Loader after switching on the HMI device. To handle this situation, you need to configure an operator control with the "Close project" function. Basic Panels 72 Operating Instructions, 04/2012, A5E02421799-03 Configuring the HMI device 5.1 Configuring devices with graphical Control Panel 5.1.7 Displaying information about the HMI device 1. Press "OP" to open the "OP Properties" dialog. 2. Open the "Device" tab. The "Device" tab is used to display specific information on the HMI device. You will need this information when contacting Technical Support. - "Device:" HMI device name - "Flashsize": Size of internal flash memory in which the HMI device image and project data are saved. The size of internal flash memory is not equivalent to application memory available for a project. - "Bootloader": Boot loader version - "Bootl. Rel. Date": Release date of the boot loader - "Image": Version of the HMI device image 3. Close the dialog with "OK." Basic Panels Operating Instructions, 04/2012, A5E02421799-03 73 Configuring the HMI device 5.1 Configuring devices with graphical Control Panel 5.1.8 Calibrating the touch screen This function is only available for touch screen devices. 1. Press "OP" to open the "OP Properties" dialog. 2. Change to the "Touch" tab. 3. Press "Recalibrate" to open the calibration screen. 4. Touch the cross in the screen center using the touch pen or your finger. 5. Using the touch pen or your finger, touch the floating cross in the corners of the screen. 6. Touch the cross in the screen center once again using the touch pen or your finger to confirm your entries. 7. Close the dialog and save your entries with "OK". &DUHIXOO\SUHVVDQGEULHIO\KROGVW\OXVRQWKHFHQWHURI WKHWDUJHW5HSHDWDVWKHWDUJHWPRYHVDURXQGWKHVFUHHQ New calibration settings have been measured. Tap the screen to register saved data. Wait for 30 seconds to cancel saved data and keep the current setting. Time limit: 30 sec Basic Panels 74 Operating Instructions, 04/2012, A5E02421799-03 Configuring the HMI device 5.1 Configuring devices with graphical Control Panel 5.1.9 Displaying licensing information for the HMI device 1. Press "OP" to open the "OP Properties" dialog. 2. Open the "License" tab. The "License" tab is used to display the licensing information for the software of the HMI device. 3. Close the dialog with "OK." Basic Panels Operating Instructions, 04/2012, A5E02421799-03 75 Configuring the HMI device 5.1 Configuring devices with graphical Control Panel 5.1.10 Enabling a data channel You must enable at least one data channel to transfer a project to the HMI device. Note After having completed the project transfer, you can protect the HMI device against unintentional overwriting of project data and of the HMI device image by locking all data channels. Enabling a data channel - Basic Panels DP 1. Press "Transfer" to open the "Transfer Settings" dialog. 2. If the HMI device is interconnected with the configuring PC via PC-PPI cable, activate the "Enable Channel" check box in the "Channel 1" field. If the HMI device is interconnected with a programming device via PROFIBUS, activate the "Enable Channel" check box in the "Channel 2" field. Press the "Advanced" button to open the "MPI / Profibus Settings" dialog. Verify the PROFIBUS parameters in this dialog. A description of the "MPI / Profibus Settings" dialog is provided in chapter 5.1.3, Changing MPI/DP settings (Page 69). 3. Close the dialog and save your entries with "OK". Note Automatic transfer is activated be setting the "Remote Control" check box. If automatic transfer is activated, the HMI device can be set remotely to transfer mode by a configuring PC or programming device. Basic Panels 76 Operating Instructions, 04/2012, A5E02421799-03 Configuring the HMI device 5.1 Configuring devices with graphical Control Panel Enabling a data channel - Basic Panels PN 1. Press "Transfer" to open the "Transfer Settings" dialog. 2. Select the "Enable Channel" check box in the "Channel 1" field. Press the "Advanced" button to open the "Profinet Settings" dialog. Verify the network parameters in this dialog. A description of the "Profinet Settings" dialog is provided in chapter 5.1.4, Changing the network configuration (Page 70). 3. Close the dialog and save your entries with "OK". Note Automatic transfer is activated be setting the "Remote Control" check box. If automatic transfer is activated, the HMI device can be set remotely to transfer mode by a configuring PC or programming device. Basic Panels Operating Instructions, 04/2012, A5E02421799-03 77 Configuring the HMI device 5.1 Configuring devices with graphical Control Panel 5.1.11 Changing password settings Password protection prevents unauthorized access to the Control Panel. NOTICE The password cannot contain spaces or special characters * ? . % / \ ' ". If the password is no longer available for the Control Panel, you first have to update the operating system before you can make any changes in the Control Panel. All data on the HMI device will be overwritten when you update the operating system. Procedure - activating password protection 1. Press "Password" to open the "Password Properties" dialog. 2. Enter a password in the "Password" text box. Touch the text box. The alphanumerical screen keyboard is displayed. 3. Confirm the password in the "Confirm Password" text box. A A 4. Close the dialog and save your entries with "OK". Procedure - Deactivating password protection 1. Press "Password" to open the "Password Properties" dialog. 2. Delete the entries in the "Password" text box. 3. Delete the entries in the "Confirm Password" text box. 4. Close the dialog and save your entries with "OK". A A Basic Panels 78 Operating Instructions, 04/2012, A5E02421799-03 Configuring the HMI device 5.1 Configuring devices with graphical Control Panel 5.1.12 Setting the Screen Saver NOTICE Burn-in effect The screen contents may leave a faint version (ghost) of the image in the background if they appear for too long. The "ghost" will disappear automatically after some time. The longer the same content is displayed on the screen, the longer it will take for the burn-in effect to disappear. The screen saver helps to prevent burn-in. Always use the screen saver. 1. Press "Screensaver" to open the "Screensaver Settings" dialog. 2. Enter the number of minutes before the screen saver is to be activated. Touch the text box to do this. You can enter values from 5 to 360 minutes. Entering "0" disables the screen saver. 3. Close the dialog and save your entries with "OK". A 5.1.13 Setting acoustic signals This function is only available for touch screen devices. 1. Press "Sound Setting" to open the "Sound Settings" dialog. 2. Select the "Sound ON" check box. If the "Sound ON" check box is selected, you get acoustic feedback when you touch the touch screen. 3. Close the dialog and save your entries with "OK". Basic Panels Operating Instructions, 04/2012, A5E02421799-03 79 Configuring the HMI device 5.2 Configuring KP300 Basic 5.2 Configuring KP300 Basic 5.2.1 Opening the Control Panel Use the "Info/Settings" menu command to open the Control Panel in the Loader. Configure your HMI device in the Control Panel. You can make the following settings: Communication settings Settings for operation Password protection Transfer settings Screen saver Protecting the Control Panel with a password In the control panel you have the option of protecting the "Info Settings > Logon/Settings" menu with a password. The following menu entries continue to be freely accessible even when password protection is enabled: Transfer Start Info Settings > Contrast Info Settings > Device / Network / Version / License Info This prevents inadvertent operations and increases security for the plant or machine because the settings cannot be edited. NOTICE If the password for the Control Panel is no longer available, you have to first update the operating system before you can make any changes in the Control Panel at "Info Settings > Logon/Settings". All data on the HMI device is overwritten when you update the operating system! Basic Panels 80 Operating Instructions, 04/2012, A5E02421799-03 Configuring the HMI device 5.2 Configuring KP300 Basic 5.2.2 Overview The following table shows the menu structure of the Control Panel with the functions that are available there for configuring your HMI device. Menu entry Function / Note Start Transfer Info/Settings Contrast Changing monitor settings (Page 83) [...] Info Displaying information about the HMI device (Page 83) Logon/Settings Startup Delay Setting the Screen Saver (Page 88) Value Screensaver Changing monitor settings (Page 83) Value Password Changing password settings (Page 87) Password Confirm Password Transfer/Network Channel 1: PROFINET Enabling a data channel (Page 84) Enable (rem. on) Enable (rem. on) Disabled IP Address/Station Name Changing the network configuration (Page 85) Station Name Station Name IP Address static or via DHCP IP via DHCP static IP IP Address Only available if "static IP" is set. Value Subnet Mask Only available if "static IP" is set. Value Def. Gateway Only available if "static IP" is set. Value Basic Panels Operating Instructions, 04/2012, A5E02421799-03 81 Configuring the HMI device 5.2 Configuring KP300 Basic Network Mode Changing the network configuration (Page 85) LLDP Protocol Enable Disable Auto Negotiation Enable Disable Speed Only available if "Auto Negotiation = Enable" 10 Mbits/s 100 Mbits/s Communication Link Only available if "Auto Negotiation = Enable" Half-Duplex Full-Duplex NTP Time server configuration (Page 86) Synchronisation with time server Enable Disable Server [1..4] IP Address Only available if "Synchronisation with time server = Disable" Value Test Server [1..4] DateTime Update rate Only available if "Synchronisation with time server = Disable" Shows date and time of the time server after a connection has been successfully established. Duration in seconds according to which the time-ofday is synchronized. Value Time shift Time difference in "hh:mm" Value Basic Panels 82 Operating Instructions, 04/2012, A5E02421799-03 Configuring the HMI device 5.2 Configuring KP300 Basic 5.2.3 Displaying information about the HMI device Menu commands in the "Info/Settings" menu The following table shows the menu commands in the "Info/Settings" menu: Menu item Information contained there Device Info HMI device name Size of the internal flash memory in which the HMI device image and project are stored The size of internal flash memory is not equivalent to application memory available for a project. Network Info IP address, MAC address and name of the HMI device. If the name does not fit in a row, the name is abbreviated and marked with "...". Version Info Version of the HMI device image Version and release date of the Boot loader License Info License provisions Procedure Proceed as follows: 1. Switch to "Info/Settings" menu on the HMI device. 2. Select the desired menu command. 3. Press or to go back to the higher-level menu. 5.2.4 Changing monitor settings Procedure Proceed as follows: 1. To change the contrast: - Switch to "Info/Settings > Contrast" menu on the HMI device. - User the cursor keys and to change the contrast and confirm with . 2. To enter the display time duration of the Loader prior to project start: - Switch to "Info/Settings > Logon/Settings > Startup Delay" menu on the HMI device. - Activate the list with and enter the display time duration in seconds. Value range: 0 to 60 - Confirm with . Note Immediate start of the project with a delay time of 0 seconds The project starts without delay if a delay time of 0 seconds is set. It is then no longer possible to call the Loader after switching on the HMI device. To handle this situation, you need to configure an operating element with the "Close project" function. Basic Panels Operating Instructions, 04/2012, A5E02421799-03 83 Configuring the HMI device 5.2 Configuring KP300 Basic 5.2.5 Enabling a data channel You must enable at least one data channel to transfer a project to the HMI device. Note After having completed the project transfer, you can protect the HMI device against unintentional overwriting of project data and of the HMI device image by locking all data channels. Procedure Proceed as follows: 1. Switch to "Info/Settings > Logon/Settings > Transfer / Network" menu on the HMI device. 2. Using the < and cursor keys, select the desired mode under "Channel 1: PROFINET". - "Enable (rem.on)": Activates the data channel and also the automatic transfer - "Enable (rem.off)": Activates the data channel without automatic transfer - "Disable": Deactivates the data channel 3. Confirm the selection with . Note If automatic transfer is activated, the HMI device can be set remotely to transfer mode by a configuring PC or programming device. Basic Panels 84 Operating Instructions, 04/2012, A5E02421799-03 Configuring the HMI device 5.2 Configuring KP300 Basic 5.2.6 Changing the network configuration NOTICE Communication errors caused by IP address conflicts Communication errors can occur if several devices in a network share the same IP address. Assign each HMI device an IP address that is unique within the network. Procedure Proceed as follows: 1. Switch to "Info/Settings > Logon/Settings > Transfer/Network > IP Address/Station Name" menu on the HMI device. 2. To enter a name for the HMI device, enter a name under "Station Name". Rules for names: - Not more than 240 characters - Characters "a" to "z", numbers "0" to "9"; allow special characters: "-" and "." - Invalid syntax: "n.n.n.n" (n=0 to 999) and "port-yxz" (x, y, z =0 to 9) 3. Select either automatic address assignment via DHCP or manual address assignment: - To acquired the IP address from a DHCP server, set the value under "IP address static or via DHCP" to "IP via DHCP" - To set a fixed IP address, set the value under "IP address static or via DHCP" to "static IP". The entries "IP Address", "Subnet Mask" and "Def. Gateway are also displayed in the "IP Address/Station Name" menu. 4. If you have assigned a static IP address, enter valid values under "IP Address", "Subnet Mask" and, if required, under "Def. Gateway". 5. Switch to "Info/Settings > Logon/Settings > Transfer/Network > Network Mode" menu on the HMI device. 6. If necessary, set the value under "LLDP Protocol" to "Enable". 7. Configure the settings for connection type and transmission rate: - To assign the connection type and transmission rate automatically, set the value under "Auto Negotiation" to "Enable"". - To assign the connection type and transmission rate manually, set the value under "Auto Negotiation" to "Disable"". The entries "Speed" and "Communication Link" are also displayed in the "Network Mode" menu. Basic Panels Operating Instructions, 04/2012, A5E02421799-03 85 Configuring the HMI device 5.2 Configuring KP300 Basic 8. If you assign the connection type and transmission rate manually, select the desired values under "Speed" and "Communication Link". - Select "100 Mbps" or "10 Mbps". - Select "Half-Duplex" or "Full-Duplex". 5.2.7 Time server configuration Introduction The HMI device has an unbuffered realtime clock. The realtime clock is set either using the configuration or using a time server. To fetch the time-of-day of the HMI device from a time server, specify up to four different time servers. The time-of-day is synchronized via the "Network Time Protocol" (NTP). Also specify the update cycle of the time-of-day and, if necessary, a time shift. Update cycle and time shift are valid for all configured time servers. You can test the availability of each time server separately. Procedure Proceed as follows: 1. Switch to "Info/Settings > Logon/Settings > Transfer/Network > NTP" menu on the HMI device. 2. To activate the acquisition of a time-of-day from a time server, set the value under "Synchronisation with time server" to "Enable". The menu entries "Server IP Address ", Test Server ", "Update rate" and "Time shift" appear. 3. Enter the IP address of the time server under "Server IP Address ". 4. To test the availability of the time server, select the command "Test Server ". The connection is established. If the connection was successfully established, date and time are displayed. Any value set at "Time shift" will not be taken into consideration. 5. If required, configure additional time servers. 6. At "Update rate", enter the time duration in seconds according to which the time-of-day will be synchronized. Value range: 10 to 86400 (1 day) 7. If required, enter the time shift in "hh:mm" under "Time shift". Value range: -24:00 to +24:00 Basic Panels 86 Operating Instructions, 04/2012, A5E02421799-03 Configuring the HMI device 5.2 Configuring KP300 Basic 5.2.8 Changing password settings Password protection prevents unauthorized access to the "Info/Settings > Logon/Settings" menu. NOTICE The password cannot contain spaces or special characters * ? . % / \ ' ". If the password for the "Info/Settings > Logon/Settings" menu is no longer available, you have to first update the operating system before you can make any changes in the "Info/Settings > Logon/Settings" menu. All data on the HMI device will be overwritten when you update the operating system. Activating password protection Proceed as follows: 1. Switch to "Info/Settings > Logon/Settings > Password" menu on the HMI device. 2. Enter the password under "Password". 3. Confirm the password under "Confirm Password". 4. Exit the menu with . Deactivating password protection Proceed as follows: 1. Switch to "Info/Settings > Logon/Settings > Password" menu on the HMI device. 2. Delete the password under "Password". 3. Confirm the (empty) password under "Confirm Password". 4. Exit the menu with . Basic Panels Operating Instructions, 04/2012, A5E02421799-03 87 Configuring the HMI device 5.2 Configuring KP300 Basic 5.2.9 Setting the Screen Saver NOTICE Burn-in effect The screen contents may leave a faint version (ghost) of the image in the background if they appear for too long. The "ghost" will disappear automatically after some time. The longer the same content is displayed on the screen, the longer it will take for the burn-in effect to disappear. The screen saver helps to prevent burn-in. Always use the screen saver. Procedure Proceed as follows: 1. Switch to "Info/Settings > Logon/Settings > Screensaver" menu on the HMI device. 2. Enter the number of minutes before the screen saver is to be activated under "Value". Value range: 5 to 360; "0" deactivates the screen saver. 3. Confirm the entry with . Basic Panels 88 Operating Instructions, 04/2012, A5E02421799-03 Commissioning a project 6.1 6 Overview Configuration phase A project - the process image of the working process - is created during configuration to visualize automated working processes. The process displays for the project contain displays for values and messages which provide information about process statuses. The process control phase follows the configuration phase. Process control phase The project must be transferred to the HMI device if it is to be used in process control. Another precondition for process control is that the HMI device is connected online to a PLC. Current working processes - operating and observing - can then be subject to process control. Transferring the project to the HMI device You can transfer a project to an HMI device as follows: Transfer from the configuring PC Restore from a PC using ProSave In this case, an archived project is transferred from a PC to the HMI device. The configuration software need not be installed on this PC. ProSave is a service tool that enables you to manage data on your HMI device. With ProSave, you can, for example, update the operating systems of the HMI device or backup its data. Commissioning and recommissioning Initial and re-start-ups differ in the following respects: When the HMI device is commissioned there is no project at first. The HMI device is also in this state after the operating system has been updated. When recommissioning, any project already on the HMI device is replaced. Basic Panels Operating Instructions, 04/2012, A5E02421799-03 89 Commissioning a project 6.2 Operating modes 6.2 Operating modes Operating modes The HMI device may be in the following operating modes: Offline Online Transfer "Offline mode" and "Online mode" can be set on both the configuring PC and the HMI device. To set these modes on the HMI device, use a corresponding operating element of the project. Changing the operating mode The configuration engineer must have configured an appropriate operating element to allow a change of the operating mode on the HMI device during ongoing operation. Further information on this may be available in your plant documentation "Offline" operating mode In this mode, there is no communication between the HMI device and PLC. Although the HMI device can be operated, it cannot exchange data with the PLC. "Online" operating mode In this mode, the HMI device and PLC communicate. You can operate the plant on the HMI device according to your system configuration. "Transfer" mode In this mode, you can transfer a project from the configuring PC to the HMI device or backup and restore HMI device data, for example. The following options are available for setting "Transfer" mode on the HMI device: When the HMI device starts up Start "Transfer" mode manually in the HMI device Loader. During ongoing operation Start the "Transfer" mode manually within the project using an operating element. The HMI device toggles to "Transfer" mode when automatic mode is set and a transfer is initiated on the configuring PC. Basic Panels 90 Operating Instructions, 04/2012, A5E02421799-03 Commissioning a project 6.3 Data transmission options 6.3 Data transmission options Overview The following table shows the options for data transfer between the HMI device and configuration PC. 1 Type Data channel Backup/restore, Serial Operating system update MPI/PROFIBUS DP Project transfers PROFINET Updating the operating system with "Reset to factory settings" Serial 1 Basic Panels DP Basic Panels PN Yes - Yes - - Yes Yes - MPI/PROFIBUS DP - - PROFINET - Yes 1 Applies for operations with PC/PPI cable 6ES7 901-3CB30-0XA0 or USB/PPI cable 6ES7 901-3DB30-0XA0. 6.4 Transfer 6.4.1 Overview Transfer the executable project from the configuration PC to the HMI device. You can start the "Transfer" mode manually or automatically on the HMI device. Transferred data is written directly to internal flash memory of the HMI device. Parameterize a corresponding data channel before you start the transfer. 6.4.2 Starting manual transfer Introduction You can manually switch the HMI device to "Transfer" mode as follows: At runtime, using a configured operating element. In the Loader of the HMI device. Requirements The project is open in WinCC flexible or WinCC. The project is compiled. The HMI device is connected to a configuring PC. The data channel is configured on the HMI device. The HMI device is in "Transfer" mode. Basic Panels Operating Instructions, 04/2012, A5E02421799-03 91 Commissioning a project 6.4 Transfer Procedure (WinCC flexible) Proceed as follows: 1. On the configuring PC, select the "Transfer settings" command from the "Project > Transfer" menu in WinCC flexible. The "Select devices for transfer" dialog opens. 2. Select the HMI device in the left area of the dialog. 3. Select the type of interconnection for the HMI device and the configuring PC. Set the connection parameters. 4. Set the transfer parameters in the right area of the dialog. 5. Start the transfer in WinCC flexible by selecting "Transfer". The configuring PC checks the connection to the HMI device. The project is transferred to the HMI device. An error message is displayed on the configuring PC if the connection is not available or disrupted. Procedure (WinCC) If you are loading a project on an HMI device, the "Advanced loading" dialog is automatically opened. You configure the appropriate interface parameters in this dialog. For further information, refer to the documentation on WinCC. Proceed as follows: 1. If you want to load a project simultaneously on several HMI devices, use multiple selection to select all the desired HMI devices in the project tree. 2. Select the "Load to device > Software" command in the shortcut menu of an HMI device. 3. When the "Advanced loading" dialog appears, configure the "Settings for loading": - Select the interface via which the project will be loaded. - Configure the corresponding interface parameters. - Click on "Load". You can open the "Advanced loading" dialog at any time via the menu command "Online > Advanced loading to device..." The "Load preview" dialog" opens. The entire project is compiled at the same time. The results is displayed in the "Load preview" dialog. 4. Check the displayed default settings, and edit these if necessary. 5. Click on "Load". Result The project is available on the HMI device following successful transfer. The transferred project is started automatically. Basic Panels 92 Operating Instructions, 04/2012, A5E02421799-03 Commissioning a project 6.4 Transfer 6.4.3 Starting automatic transfer Introduction If automatic transfer is activated, the HMI device automatically changes to "Transfer" mode at runtime as soon as a transfer is started on the connected configuring PC. Note With automatic transfer, the HMI device only changes into "Transfer" mode when the project is running on the HMI device. Automatic transfer is particularly suited for the test phase of a new project since transfer is completed without interfering with the HMI device. NOTICE If automatic transfer is activated on the HMI device and a transfer is initiated on the configuring PC, the project currently running is automatically stopped. The HMI device then automatically switches to "Transfer" mode. After the commissioning phase, deactivate the automatic transfer so that the HMI device cannot be inadvertently switched to transfer mode. Transfer mode can trigger unintentional actions in the plant. You can issue a password in the Control Panel to restrict access to the transfer settings and thus avoid unauthorized modifications. Requirements The project is open in WinCC flexible or WinCC. The project is compiled. The HMI device is connected to a configuring PC. The data channel is configured on the HMI device The HMI device is in "Transfer" mode. The automatic transfer is activated in the data channel for the transfer The project is started on the HMI device. Basic Panels Operating Instructions, 04/2012, A5E02421799-03 93 Commissioning a project 6.4 Transfer Procedure (WinCC flexible) Proceed as follows: 1. On the configuring PC, select the "Transfer settings" command from the "Project > Transfer" menu in WinCC flexible. The "Select devices for transfer" dialog opens. 2. Select the HMI device in the left area of the dialog. 3. Select the type of interconnection for the HMI device and the configuring PC. Set the connection parameters. 4. Set the transfer parameters in the right area of the dialog. 5. Start the transfer in WinCC flexible by selecting "Transfer". Procedure (WinCC) If you are loading a project on an HMI device, the "Advanced loading" dialog is automatically opened. You configure the appropriate interface parameters in this dialog. For further information, refer to the documentation on WinCC. Proceed as follows: 1. If you want to load a project simultaneously on several HMI devices, use multiple selection to select all the desired HMI devices in the project tree. 2. Select the "Load to device > Software" command in the shortcut menu of an HMI device. 3. When the "Advanced loading" dialog appears, configure the "Settings for loading": - Select the interface via which the project will be loaded. - Configure the corresponding interface parameters. - Click on "Load". You can open the "Advanced loading" dialog at any time via the menu command "Online > Advanced loading to device..." The "Load preview" dialog" opens. The entire project is compiled at the same time. The results is displayed in the "Load preview" dialog. 4. Check the displayed default settings, and edit these if necessary. 5. Click on "Load". Result The configuring PC checks the connection to the HMI device. The HMI device shuts down the current project and automatically changes to "Transfer" mode. The project is transferred to the HMI device. An error message is displayed on the configuring PC if the connection is not available or disrupted. The project is available on the HMI device following successful transfer. The transferred project is started automatically. Basic Panels 94 Operating Instructions, 04/2012, A5E02421799-03 Commissioning a project 6.4 Transfer 6.4.4 Testing a project Introduction You have the following options to test a project: Test the project on the configuring PC You can test a project at a configuring PC, using a simulator. For detailed information, refer to the "WinCC flexible" user manual and to the WinCC flexible and WinCC Online Help. Offline testing of the project on the HMI device Offline testing means that communication between the HMI device and PLC is down while the test is being carried out. Online testing of the project on the HMI device Online testing means that the HMI device and PLC communicate with each other during testing. Perform the tests, starting with the "Offline test", followed by the "Online test". Note You should always test the project on the HMI device on which the project will be used. Check the following: 1. Check the correct layout of the screens. 2. Check the screen navigation. 3. Check the input objects. 4. Enter the tag values. The test ensures that the project will run as you intended on the HMI device. Requirements for offline testing The project has been transferred to the HMI device. The HMI device is in "Offline" mode. Procedure In "Offline" mode, you can test individual project functions on the HMI device without them being affected by the PLC. PLC tags, therefore, are not updated. Test the operator controls and visualization of the project as far as possible without connecting to the PLC. Basic Panels Operating Instructions, 04/2012, A5E02421799-03 95 Commissioning a project 6.5 Backup and restore Requirements for online testing The project has been transferred to the HMI device. The HMI device is in "Online" mode. Procedure In "Online" mode, you can test individual project functions on the HMI device without them being affected by the PLC. PLC tags are updated in this case. You have the option to test all communication-dependent functions, for example alarms, etc. Test the operator controls and views of the project. 6.5 Backup and restore 6.5.1 Overview Backup and restore You can back up and restore the following data in the internal flash memory of the HMI device with a PC: Project and HMI device image Password list Recipe data Use one of the following tools for backup and restore: WinCC WinCC flexible ProSave General information NOTICE Power failure If a complete restore operation is interrupted due to power failure on the HMI device, the operating system of the HMI device may be deleted. In this case, you have to reset the HMI device to its factory settings. Compatibility conflict If a message is output on the HMI device warning of a compatibility conflict during the restore operation, the operating system must be updated. Note A data transfer can take several minutes, depending on data volume and transmission rate. Observe the status display. Do not interrupt the data transfer. Basic Panels 96 Operating Instructions, 04/2012, A5E02421799-03 Commissioning a project 6.5 Backup and restore See also Data transmission options (Page 91) 6.5.2 Backup and restore using WinCC flexible Requirement No project is open on the configuration PC in WinCC flexible. The HMI device is connected to this configuration PC. The data channel is programmed on the HMI device. Procedure - backup Proceed as follows: 1. On the configuration PC, select the "Communication settings" command in the menu "Project > Transfer" in WinCC flexible. The "Communication settings" dialog box opens. 2. Select the type of HMI device. 3. Select the type of connection between the HMI device and the configuration PC. Set the connection parameters. 4. Close the dialog with "OK". 5. Select the "Backup" command in the menu "Project > Transfer" in WinCC flexible. The "Backup settings" dialog opens. 6. Select the data to be backed up. 7. Select a destination folder and a file name for the "*.psb" backup file. 8. Set "Transfer" mode on the HMI device. If automatic transfer mode is enabled on the HMI device, the HMI device automatically sets "Transfer" mode when a backup is initiated. 9. Start the backup operation in WinCC flexible with "OK" on the configuration PC. 10.Follow the instructions in WinCC flexible. A status view opens to indicate the progress of the operation. Result The system outputs a message when the backup is completed. The relevant data is now backed up on the configuration PC. Basic Panels Operating Instructions, 04/2012, A5E02421799-03 97 Commissioning a project 6.5 Backup and restore Procedure - restoring Proceed as follows: 1. On the configuration PC, select the "Communication settings" command in the menu "Project > Transfer" in WinCC flexible. The "Communication settings" dialog box opens. 2. Select the type of HMI device. 3. Select the type of connection between the HMI device and the configuration PC. 4. Set the connection parameters. 5. Close the dialog with "OK". 6. Select the "Restore" command in the menu "Project > Transfer" in WinCC flexible. The "Restore Settings" dialog opens. 7. Select the "*.psb" backup file to be restored from the "Open" field. You can see the HMI device for which the backup file was created and the type of backup data the file contains. 8. Set "Transfer" mode on the HMI device. If automatic transfer mode is enabled on the HMI device, the device automatically sets "Transfer" mode when a restore operation is initiated. 9. Start the restore operation in WinCC flexible with "OK" on the configuration PC. Follow the instructions in WinCC flexible. A status view opens to indicate the progress of the operation. Result When the restore is successfully completed, the data backed up on the configuration PC is now on the HMI device. Basic Panels 98 Operating Instructions, 04/2012, A5E02421799-03 Commissioning a project 6.5 Backup and restore 6.5.3 Backup and restore using ProSave Requirements The HMI device is connected to a PC on which ProSave is installed. The data channel is parameterized on the HMI device. Procedure - backup Proceed as follows: 1. Go to the Windows Start menu and start ProSave on the PC. 2. Select the HMI device type in the "General" tab. 3. Select the type of interconnection for the HMI device and the PC. Set the connection parameters. 4. Select the data to be backed up in the "Backup" tab. - "Complete backup" generates a backup copy of configuration data, recipe data and the HMI device image to a file in PSB format. - "Recipes" generates a backup copy of the HMI device's recipe data records in PSB format. - "Recipes (CSV format)" saves a backup copy of the HMI device's recipe data records to a text file in CSV format. The semicolon is used as column separator. - "User management" generates a backup copy of the HMI device's user data in PSB format. 5. Select the folder and file name for the *.psb" backup file . When generating a backup copy of recipes in CSV format, only select a folder. A CSV file is generated for each recipe in this folder. 6. Set "Transfer" mode on the HMI device. If automatic transfer mode is enabled on the HMI device, the HMI device automatically sets "Transfer" mode when a backup is initiated. 7. Start the backup operation in ProSave with "Start Backup". Follow the instructions in ProSave. A progress bar opens to indicate the progress of the operation. Result The system outputs a message when the backup is completed. A backup copy of the data is now available on the PC. Basic Panels Operating Instructions, 04/2012, A5E02421799-03 99 Commissioning a project 6.5 Backup and restore Procedure - restore Proceed as follows: 1. Go to the Windows Start menu and start ProSave on the PC. 2. Select the HMI device type in the "General" tab. 3. Select the type of interconnection for the HMI device and the PC. 4. Set the connection parameters. 5. Select the "*.psb" backup file to be restored from the "Restore" tab. You can see the HMI device for which the backup file was created and the type of backup data the file contains. Select one or several CSV files from the source folder to restore the recipes from CSV files. 6. Set "Transfer" mode on the HMI device. If automatic transfer mode is enabled on the HMI device, the device automatically sets "Transfer" mode when a restore operation is initiated. 7. Start the restore operation in ProSave on the PC with "Start Restore". 8. Follow the instructions in ProSave. A progress bar indicates the progress of the operation. Result When the restore is successfully completed, the data backed up on the PC is now on the HMI device. 6.5.4 Backup and restore using WinCC Requirements The HMI device is connected to the configuring PC or the PC with ProSave The HMI device is selected in the project navigation. If a server is used for data backup: The HMI device has access to the server Backup of the data of the HMI device Proceed as follows: 1. Select the "Backup" command from the "Online > HMI device maintenance" menu. The "SIMATIC ProSave" dialog box opens. 2. Select the data to backup for the HMI device under "Data type". 3. Enter the name of the backup file under "Save as". 4. Click "Start Backup". This starts the data backup. The backup operation takes some time, depending on the connection selected. Basic Panels 100 Operating Instructions, 04/2012, A5E02421799-03 Commissioning a project 6.6 OS update - Basic Panel DP Restoring the data of the HMI device Proceed as follows: 1. Select the "Restore" command from the "Online > HMI device maintenance" menu. 2. Enter the name of the backup file under "Save as". Information about the selected backup file is displayed under "Content". 3. Click "Start Restore". This starts the restoration. This operation takes some time, depending on the connection selected. 6.6 OS update - Basic Panel DP 6.6.1 Overview Updating the operating system A compatibility conflict may occur when transferring a project to the HMI device. This is caused by different versions of the configuration software used and the HMI device image available on the HMI device. If there are different versions, the transfer is aborted. A message indicating a compatibility conflict is displayed on the configuring PC. There are two ways to match the versions: Update the HMI device image if the project was created with the most recent version of the configuration software. Transfer a matching version of the HMI device image if you do not want to adapt the project for the HMI device to the most recent version of the configuration software for the project. NOTICE Data loss All data on the HMI device, such as the project and licenses, will be deleted when you update the operating system. Note Calibrating the touch screen After the update, you may have to recalibrate the touch screen. Basic Panels Operating Instructions, 04/2012, A5E02421799-03 101 Commissioning a project 6.6 OS update - Basic Panel DP 6.6.2 Resetting factory settings In ProSave, WinCC flexible or WinCC, you can update the operating system with or without resetting to factory settings. Updating the operating system without reset to factory settings First, switch into "Transfer" mode on the HMI device or use the automatic transfer function if the project is active. Then start the operating system update in ProSave, WinCC flexible or WinCC. Updating the operating system with reset to factory setting NOTICE Data channel When resetting to factory settings, all data channel parameters used are reset. The transfer can only be started following reconfiguration of the data channel. Note You have to perform an operating system update with reset to factory setting if the HMI device does not yet have an operating system or if the HMI device's operating system is corrupt. First, start the operating system update in ProSave, WinCC flexible or WinCC, and switch the power on the HMI device off and on again when prompted. See also Data transmission options (Page 91) 6.6.3 Updating the Operating System using WinCC flexible CAUTION Updating the operating system deletes all data on the HMI device When you update the operating system you delete data on the target system. For this reason, it is advisable to backup the following data: * User administration * Recipes Resetting to factory settings also deletes the License Keys. You should also back up the License Keys before resetting to factory settings. Basic Panels 102 Operating Instructions, 04/2012, A5E02421799-03 Commissioning a project 6.6 OS update - Basic Panel DP Requirements The HMI device is connected to a configuring PC. No project is open in WinCC flexible. When updating the operating system without reset to factory setting only: The data channel is configured on the HMI device. Procedure Proceed as follows: 1. When updating the operating system with reset to factory setting only: Switch off power to the HMI device. 2. On the configuring PC, select the "Communication settings" command in the menu "Project > Transfer" in WinCC flexible. The "Communication Settings" dialog opens. 3. Select the type of HMI device. 4. Select the type of connection between the HMI device and the configuring PC, then set the connection parameters. 5. Close the dialog box with "OK". 6. Select the "OS Update" command from the "Project > Transfer" menu in WinCC flexible. 7. Select whether to update the operating system with or without restoring the factory settings by setting the "Reset to factory settings" check box accordingly. 8. Select the HMI device image file "*.img" under "Image path". The HMI device image files are available under "WinCC flexible Images" in the WinCC flexible installation folder or on the WinCC flexible installation DVD. The output area provides information on the version of the successfully opened HMI device image file. 9. When updating without reset to the factory settings only: Set "Transfer" mode on the HMI device. If automatic transfer mode is enabled on the HMI device, the device automatically sets "Transfer" mode when an update is initiated. 10.In WinCC flexible, select "Update OS" on the configuring PC to run the operating system update. 11.When updating with reset to the factory settings only: Switch on the power supply to the HMI device. 12.Follow the instructions in WinCC flexible. A progress bar indicates the progress of the operating system update. Result A message is displayed when the operating system update is successfully completed. The HMI device no longer contains any project data. Basic Panels Operating Instructions, 04/2012, A5E02421799-03 103 Commissioning a project 6.6 OS update - Basic Panel DP 6.6.4 Updating the Operating System using ProSave Requirements The HMI device is connected to a PC on which ProSave is installed. When updating the operating system without reset to factory settings only: The data channel is configured on the HMI device. Procedure Proceed as follows: 1. When updating the operating system with reset to factory settings only: Switch off power to the HMI device. 2. Go to the Windows Start menu and start ProSave on the PC. 3. Select the HMI device type in the "General" tab. 4. Select the type of connection between the HMI device and the PC, then set the connection parameters. 5. Select the "OS Update" tab. 6. Select whether to update the operating system with or without restoring the factory settings by setting the "Reset to factory settings" check box accordingly. 7. Select the HMI device image file "*.img" under "Image path". WinCC flexible: The HMI device image files are available under "WinCC flexible Images" in the WinCC flexible installation folder or on the installation CD. WinCC: The HMI device image files are available under "Programme\Automation\Portal V11\Data\Hmi\Transfer\11.0\Images". The output area provides information on the version of the successfully opened HMI device image file. 8. When updating without reset to the factory settings only: Set "Transfer" mode on the HMI device. If automatic transfer mode is enabled on the HMI device, the device automatically sets "Transfer" mode when an update is initiated. 9. Select "Update OS" on the PC to run the operating system update. 10.When updating with reset to the factory settings only: Switch on the power supply to the HMI device. 11.Follow the instructions in ProSave. A progress bar indicates the progress of the operating system update. Result A message is displayed when the operating system update is successfully completed. The HMI device no longer contains any project data. Basic Panels 104 Operating Instructions, 04/2012, A5E02421799-03 Commissioning a project 6.7 OS update - Basic Panel PN 6.7 OS update - Basic Panel PN 6.7.1 Overview Updating the operating system A compatibility conflict may occur when transferring a project to the HMI device. This is caused by different versions of the configuration software used and the HMI device image available on the HMI device. If there are different versions, the transfer is aborted. A message indicating a compatibility conflict is displayed on the configuring PC. There are two ways to match the versions: Update the HMI device image if the project was created with the most recent version of the configuration software. Transfer a matching version of the HMI device image if you do not want to adapt the project for the HMI device to the most recent version of the configuration software for the project. NOTICE Data loss All data on the HMI device, such as the project and licenses, will be deleted when you update the operating system. Note Calibrating the touch screen After the update, you may have to recalibrate the touch screen. Basic Panels Operating Instructions, 04/2012, A5E02421799-03 105 Commissioning a project 6.7 OS update - Basic Panel PN 6.7.2 Resetting factory settings In ProSave, WinCC flexible or WinCC, you can update the operating system with or without resetting to factory settings. Updating the operating system without reset to factory settings First, switch into "Transfer" mode on the HMI device or use the automatic transfer function if the project is active. Then start the operating system update in ProSave, WinCC flexible or WinCC. Updating the operating system with reset to factory setting NOTICE Data channel When resetting to factory settings, all data channel parameters used are reset. The transfer can only be started following reconfiguration of the data channel. Note You have to perform an operating system update with reset to factory setting if the HMI device does not yet have an operating system or if the HMI device's operating system is corrupt. First, start the operating system update in ProSave, WinCC flexible or WinCC, and switch the power on the HMI device off and on again when prompted. See also Data transmission options (Page 91) 6.7.3 Updating the operating system using WinCC flexible If possible, you should use the interface with the highest bandwidth for this connection, such as Ethernet. Updating the operating system via a serial connection can take up to an hour. CAUTION Updating the operating system deletes all data on the HMI device When you update the operating system you delete data on the target system. For this reason, it is advisable to backup the following data: * User administration * Recipes Resetting to factory settings also deletes the License Keys. You should also back up the License Keys before resetting to factory settings. Basic Panels 106 Operating Instructions, 04/2012, A5E02421799-03 Commissioning a project 6.7 OS update - Basic Panel PN Requirements No project is open on the configuring PC in WinCC flexible. The HMI device is connected to this configuring PC. The data channel is configured on the HMI device. Procedure Proceed as follows: 1. On the configuring PC, select the "Communication settings" command from the "Projekt > Transfer" menu in WinCC flexible. The "Communication Settings" dialog opens. 2. Select the type of HMI device. 3. Select the type of interconnection for the HMI device and the configuring PC. 4. Set the connection parameters. 5. Close the dialog box with "OK". 6. In WinCC flexible, select the command "OS Update" from the "Projekt > Transfer" menu. 7. Select the HMI device image file "*.img" under "Image path". The HMI device image files are available under "WinCC flexible Images" in the WinCC flexible installation folder or on the WinCC flexible installation CD. The output area provides information on the version of the successfully opened HMI device image file. 8. Switch into "Transfer" mode on the HMI device. If you have activated automatic transfer mode for the HMI device, the device automatically switches to "Transfer" mode when an update is initiated. 9. In WinCC flexible, select "Update OS" on the configuring PC to run the operating system update. 10.Follow the instructions in WinCC flexible. A progress bar indicates the progress of the operating system update. Result A message is displayed when the operating system update is successfully completed. The HMI device no longer contains any project data. Basic Panels Operating Instructions, 04/2012, A5E02421799-03 107 Commissioning a project 6.7 OS update - Basic Panel PN 6.7.4 Updating the operating system using ProSave Requirements The HMI device is connected to a PC on which ProSave is installed. The data channel is configured on the HMI device. Procedure Proceed as follows: 1. Go to the Windows Start menu and start ProSave on the PC. 2. Select the HMI device type in the "General" tab. 3. Select the type of connection between the HMI device and the PC. 4. Set the connection parameters. 5. Select the "OS Update" tab. 6. Select the HMI device image file "*.img" under "Image path". WinCC flexible: The HMI device image files are available under "WinCC flexible Images" in the WinCC flexible installation folder or on the installation CD. WinCC: The HMI device image files are available under "Programme\Automation\Portal V11\Data\Hmi\Transfer\11.0\Images". The output area provides information on the version of the successfully opened HMI device image file. 7. Switch into "Transfer" mode on the HMI device. If you have activated automatic transfer mode for the HMI device, the device automatically switches to "Transfer" mode when an update is initiated. 8. Select "Update OS" n the PC to run the operating system update. 9. Follow the instructions in ProSave. A progress bar indicates the progress of the operating system update. Result A message is displayed when the operating system update is successfully completed. The HMI device no longer contains any project data. Basic Panels 108 Operating Instructions, 04/2012, A5E02421799-03 Commissioning a project 6.7 OS update - Basic Panel PN 6.7.5 Updating the operating system using WinCC If possible, you should use the interface with the highest bandwidth for this connection, such as Ethernet. Updating the operating system via a serial connection can take up to an hour. CAUTION Updating the operating system deletes all data on the HMI device When you update the operating system you delete data on the target system. For this reason, it is advisable to backup the following data: * User administration * Recipes Resetting to factory settings also deletes the License Keys. You should also back up the License Keys before resetting to factory settings. Requirement The HMI device is connected to the configuring PC The appropriate data channel is configured on the HMI device. The HMI device is selected in the project navigation. Procedure Proceed as follows: Proceed as follows to update the operating system: 1. Select the "Update operating system" command from the menu under "Online > HMI device maintenance" on the configuring PC in WinCC. The "SIMATIC ProSave [OS-Update]" dialog opens. The path to the image of the operating system has been preset. 2. If necessary, select another path to the operating system image you want to transfer to the HMI device. 3. Click "Update OS". Result This starts the update. The update operation can take time, depending on the connection selected. Basic Panels Operating Instructions, 04/2012, A5E02421799-03 109 Commissioning a project 6.7 OS update - Basic Panel PN 6.7.6 Resetting to factory settings with WinCC flexible CAUTION Updating the operating system deletes all data on the HMI device When you update the operating system you delete data on the target system. For this reason, it is advisable to backup the following data: * User administration * Recipes Resetting to factory settings also deletes the License Keys. You should also back up the License Keys before resetting to factory settings. Requirements No project is open on the configuring PC in WinCC flexible. The HMI device is connected to this configuring PC over the standard Ethernet cable. Have the MAC address of your HMI device's Ethernet interface to hand. - The MAC address is displayed briefly when the HMI device is turned on. - The MAC address is displayed in the "Profinet" dialog of the "Device" tab in the Control Panel. Procedure for setting the PC interface 1. Select "Start > Control Panel > Set PG / PC interface" on the configuring PC. 2. Select "S7ONLINE (STEP7) -> TCP / IP" from the "Application access point" area. 3. Select the interface which is connected to the HMI device from the "Interface parameterization used" area. 4. Confirm your entries. Procedure for resetting factory settings Proceed as follows: 1. On the configuring PC, select the "Communication settings" command in the menu "Project > Transfer" in WinCC flexible. The "Communication Settings" dialog opens. 2. Select the HMI device type from the "General" tab, and select "Ethernet" from the "Connection" area. 3. Enter an IP address. Basic Panels 110 Operating Instructions, 04/2012, A5E02421799-03 Commissioning a project 6.7 OS update - Basic Panel PN Note Possible address conflicts with incorrect IP address Do not use a dynamic IP configuration for "Reset to factory settings". Specify a unique IP address in which the configuring PC is located. For the duration of the update process, the HMI device is automatically assigned to the specified address. If the HMI device has already been used with WinCC flexible or ProSave you can use the existing IP address for "Reset to factory settings". 4. Confirm your entries. 5. Select the "OS Update" command from the "Project > Transfer" menu in WinCC flexible. 6. Select the "Reset to factory settings" check box. A text box opens where you can enter the MAC address. 7. Enter the HMI device's MAC address in the text box. 8. Select the HMI device image file "*.img" under "Image path". The HMI device image files are available under "WinCC flexible Images" in the WinCC flexible installation folder or on the WinCC flexible installation DVD. The output area provides information on the version of the successfully opened HMI device image file. 9. In WinCC flexible, select "Update OS" on the configuring PC to run the operating system update. 10.Follow the instructions in WinCC flexible on the configuring PC. A progress bar indicates the progress of the operating system update. Result A message is displayed when the operating system update is successfully completed. The HMI device no longer contains any project data. The factory settings are reset. Note If you can no longer open the Control Panel on the HMI device because the operating system is missing, carry out the above-described steps to reset the device to the factory settings, and try again. Note Calibrating the touch screen When the restore operation has been completed, you may have to recalibrate the touch screen. Basic Panels Operating Instructions, 04/2012, A5E02421799-03 111 Commissioning a project 6.7 OS update - Basic Panel PN 6.7.7 Resetting to factory settings with ProSave Requirement The HMI device is connected over the Ethernet to a PC on which ProSave is installed. Have the MAC address of your HMI device's Ethernet interface to hand. - The MAC address is displayed briefly when the HMI device is turned on. - Touch HMI devices: The MAC address is displayed in the "Profinet" dialog of the "Device" tab in the Control Panel. - KP300 Basic: The MAC address is displayed under "Info/Settings > Network Info". Procedure for setting the PC interface 1. Select "Start > Control Panel > Set PG / PC interface" on the configuring PC. 2. Select "S7ONLINE (STEP7) -> TCP / IP" from the "Application access point" area. 3. Select the interface which is connected to the HMI device from the "Interface parameterization used" area. 4. Confirm your entries. Procedure for resetting factory settings Proceed as follows: 1. Go to the Windows Start menu and start ProSave on the PC. 2. Select the HMI device type from the "General" tab, and select "Ethernet" from the Connection area. 3. Enter an IP address. Note Possible address conflicts with incorrect IP address Do not use a dynamic IP configuration for "Reset to factory settings". Specify a unique IP address of the subnet in which the configuring PC is located. For the duration of the update process, the HMI device is automatically assigned to the specified address of ProSave. If the HMI device has already been used with WinCC flexible or ProSave you can use the existing IP address for "Reset to factory settings". Basic Panels 112 Operating Instructions, 04/2012, A5E02421799-03 Commissioning a project 6.7 OS update - Basic Panel PN 4. Change to the "OS Update" tab. 5. Select the "Reset to factory settings" check box. A text box opens where you can enter the MAC address. 6. Enter the HMI device's MAC address in the text box. 7. Select the HMI device image file "*.img" under "Image path". The HMI device image files are available under "WinCC flexible Images" in the WinCC flexible installation folder or on the WinCC flexible installation DVD. The output area provides information on the version of the successfully opened HMI device image file. 8. Select "Update OS" on the PC to start the "Reset to factory settings" process. 9. Follow the instructions in ProSave. A progress bar indicates the progress of the operating system update. Result A message is displayed when the operating system update is successfully completed. The HMI device no longer contains any project data. The factory settings are reset. Note If you can no longer open the Control Panel on the HMI device because the operating system is missing, carry out the above-described steps to reset the device to the factory settings, and try again. Note Calibrating the touch screen When the restore operation has been completed, you may have to recalibrate the touch screen. Basic Panels Operating Instructions, 04/2012, A5E02421799-03 113 Commissioning a project 6.7 OS update - Basic Panel PN 6.7.8 Resetting to factory settings with WinCC If possible, you should use the interface with the highest bandwidth for this connection, such as Ethernet. Updating the operating system via a serial connection can take up to an hour. CAUTION Updating the operating system deletes all data on the HMI device When you update the operating system you delete data on the target system. For this reason, it is advisable to backup the following data: * User administration * Recipes Resetting to factory settings also deletes the License Keys. You should also back up the License Keys before resetting to factory settings. Note The following is required to restore factory settings using Ethernet: * MAC address of the HMI device * Available IP address * PG/PC interface of the configuring PC that is set to Ethernet TCP/IP You configure the PG/PC interface using the Control Panel of the configuring PC. Select "S7ONLINE (STEP7) -> TCP/IP" under "Application access point". Requirements The HMI device is connected to the configuring PC The HMI device is selected in the project navigation. Resetting the HMI device to factory settings To reset the HMI device to factory settings, proceed as follows: 1. Switch off power to the HMI device. 2. Select the "Update operating system" command from the menu under "Online > HMI device maintenance" on the configuring PC in WinCC. The "SIMATIC ProSave [OS-Update]" dialog opens. The path to the image of the operating system has been preset. 3. If necessary, select another path to the operating system image you want to transfer to the HMI device. 4. Activate "Reset to factory settings". 5. Click "Update OS". 6. To "Reset to factory settings", switch on power to the HMI device again. This operation can take time. Result The operating system of the HMI device is now updated to the current version. Basic Panels 114 Operating Instructions, 04/2012, A5E02421799-03 Maintenance and care 7.1 7 Maintenance and care Introduction The HMI device is designed for maintenance-free operation. Make sure you keep the touch screen and keyboard membrane clean. Requirements Use a cleaning cloth dampened with a cleaning agent to clean the equipment. Only use water with a little liquid soap or a screen cleaning foam. NOTICE Unintentional response When cleaning the touch screen, an unintentional response in the PLC can be triggered by touching keys. Switch the HMI device off before cleaning to prevent unintentional responses. Damage caused by unauthorized cleaning products The HMI device may be damaged if compressed air, steam jet-air ejectors, aggressive solvents or scouring powders are used for cleaning purposes. Do not clean the HMI device with compressed air or steam jet blowers. Do not use aggressive solvents or scouring powder. Procedure Proceed as follows: 1. Shut down the HMI device. 2. Spray the cleaning solution onto a cleaning cloth. Do not spray directly onto the HMI device. 3. Clean the HMI device. When cleaning the display wipe from the screen edge inwards. Basic Panels Operating Instructions, 04/2012, A5E02421799-03 115 Maintenance and care 7.2 Recycling 7.2 Recycling Recycling and disposal The HMI devices described in these operating instructions can be recycled due to the low levels of pollutants. Contact a certified disposal service company for environmentally sound recycling and disposal of your old devices. Basic Panels 116 Operating Instructions, 04/2012, A5E02421799-03 Technical specifications 8.1 8 Certificates and approvals Approvals CAUTION The following overview shows possible approvals. The HMI device itself is certified as shown on the rear panel labels. CE approval The HMI device meets the general and safety-related requirements of the following EC directives and conforms to the harmonized European standards (EN) for programmable logic controllers published in the official gazettes of the European Union: 2004/108/EC "Electromagnetic Compatibility" (EMC Directive) EC Declaration of Conformity The EC Declarations of Conformity are available to the relevant authorities at the following address: Siemens AG Industry Sector I IA AS FA WF AMB PO Box 1963 D-92209 Amberg, Germany Marking for Australia The HMI device fulfills the requirements of standard AS/NZS 2064 (Class A). UL approval Underwriters Laboratories Inc., to UL 508 (Industrial Control Equipment) CSA C22.2 No. 142 (Process Control Equipment) IEC 61131 The HMI device fulfills requirements and criteria to IEC 61131-2, Programmable Logic Controllers, Part 2: Operating resource requirements and tests. Basic Panels Operating Instructions, 04/2012, A5E02421799-03 117 Technical specifications 8.2 Directives and declarations 8.2 Directives and declarations 8.2.1 Electromagnetic compatibility Introduction The HMI device fulfills, among other things, the requirements of the EMC law pertaining to the domestic European market. EMC-compatible installation of the HMI device The EMC-compliant installation of the HMI device and the application of interference-proof cable is the basis for interference-free operation. The "Directives for interference-free installation of PLCs" and the "PROFIBUS Networks" manual also apply for the installation of the HMI device. Pulse-shaped disturbance The following table shows the electromagnetic compatibility of modules with regard to pulseshaped interference. The precondition for electromagnetic compatibility is that the HMI device meets the specifications and guidelines for electrical installation. Pulse-shaped disturbance Tested with Degree of severity Electrostatic discharge in accordance with IEC 61000-4-2 Air discharge: 8 kV Contact discharge: 6 kV 3 Burst pulses (high-speed transient interference) in accordance with IEC 61000-4-4 2 kV power supply cable 2 kV signal cable, > 30 m 1 kV signal cable, < 30 m 3 High-power surge pulses in accordance with IEC 61000-4-5, external protective circuit required (refer to the manual Automation System S7-300, Installation, "Lightning and overvoltage protection" section) Asymmetrical coupling 2 kV power cable DC voltage with protective elements 3 2 kV signal/data cable, > 30 m, with protective elements as required Symmetrical coupling 1 kV power cable DC voltage with protective elements 3 1 KV signal cable, > 30 m, with protective elements as required Basic Panels 118 Operating Instructions, 04/2012, A5E02421799-03 Technical specifications 8.2 Directives and declarations Sinusoidal interference The following table shows the EMC behavior of the modules with respect to sinusoidal interference. This requires the HMI device to meet the specifications and directives for electrical installation. Sinusoidal interference Test values HF radiation (in electromagnetic fields) in accordance with IEC 610004-3 * 80% amplitude modulation at 1 kHz with 10 V/m in the range of 80 MHz to 1 GHz with 3 V/m in the range 1.4 GHz to 2 GHz with 1 V/m the range 2 GHz to 2.7 GHz * 10 V/m with 50% pulse modulation at 900 MHz 10 V/m with 50% pulse modulation at 1.89 GHz RF interference current on cables and cable shielding conforming to IEC 61000-4-6 Degree of severity Test voltage 10 V, with 80% amplitude modulation of 1 kHz in the 9 MHz to 80 MHz range 3 3 Emission of radio interference The following table shows the unwanted emissions from electromagnetic fields in accordance with EN 55011, Limit Value Class A, Group 1, measured at a distance of 10 m. From 30 to 230 MHz < 40 dB (V/m) quasi-peak From 230 to 1000 MHz < 47 dB (V/m) quasi-peak Additional measures To connect an HMI device to the public electric network, you must ensure its compliance with Limit Value Class B to EN 55022. 8.2.2 ESD guideline What does ESD mean? An electronic module is equipped with highly integrated components. Due to their design, electronic components are highly sensitive to overvoltage and thus to the discharge of static electricity. Such electronic components or modules are labeled as electrostatic sensitive devices. The following abbreviations are commonly used for electrostatic sensitive devices: ESD - Electrostatic sensitive device ESD - Electrostatic Sensitive Device as a common international designation Basic Panels Operating Instructions, 04/2012, A5E02421799-03 119 Technical specifications 8.2 Directives and declarations Electrostatic sensitive devices can be labeled with an appropriate symbol. CAUTION Damage to ESD from touch Electrostatic sensitive devices, ESD, can be destroyed by voltages which are far below the human perception limit. If you touch a component or electrical connections of a module without discharging any electrostatic energy, these voltages may arise. The damage to a module by an overvoltage can often not be immediately detected and only becomes evident after an extended period of operation. The consequences are incalculable and range from unforeseeable malfunctions to a total failure of the machine or plant. Avoid touching components directly. Make sure that persons, the workstation and the packaging are properly grounded. Charge Every person without a conductive connection to the electrical potential of his/her surroundings can be electrostatically charged. 9ROWDJH The material with which this person comes into contact is of particular significance. The figure shows the maximum electrostatic voltages with which a person is charged, depending on humidity and material. These values conform to the specifications of IEC 61000-4-2. >N9@ >@ 5HODWLYHKXPLGLW\ Synthetic materials Wool Antistatic materials such as wood or concrete Basic Panels 120 Operating Instructions, 04/2012, A5E02421799-03 Technical specifications 8.2 Directives and declarations CAUTION Grounding measures There is no equipotential bonding without grounding. An electrostatic charge is not discharged and may damage the ESD. Protect yourself against discharge of static electricity. When working with electrostatic sensitive devices, make sure that the person and the workplace are properly grounded. Protective measures against discharge of static electricity Disconnect the power supply before you install or remove modules which are sensitive to ESD. Pay attention to good grounding: - When handling electrostatical sensitive devices, make sure that persons, the workstation and devices, tools and packaging used are properly grounded. In this manner, you avoid static discharge. Avoid direct contact: - As a general rule, do not touch electrostatic sensitive devices, except in the case of unavoidable maintenance work. - Hold the modules at their edge so that you do not touch the connector pins or conductor paths. In this way, the discharge energy does not reach and damage the sensitive components. - Discharge your body electrostatically before you take a measurement at a module. Do so by touching grounded metallic parts. Always use grounded measuring instruments. Basic Panels Operating Instructions, 04/2012, A5E02421799-03 121 Technical specifications 8.3 Dimension drawings 8.3 Dimension drawings 8.3.1 Dimension drawing of the KP300 Basic mono PN $OOGLPHQVLRQVLQPP Basic Panels 122 Operating Instructions, 04/2012, A5E02421799-03 Technical specifications 8.3 Dimension drawings Dimension drawing of the KP400 Basic color PN 8.3.2 $OOGLPHQVLRQVLQPP Basic Panels Operating Instructions, 04/2012, A5E02421799-03 123 Technical specifications 8.3 Dimension drawings Dimension drawing of the KTP400 Basic mono PN $OOGLPHQVLRQVLQPP 8.3.3 Basic Panels 124 Operating Instructions, 04/2012, A5E02421799-03 Technical specifications 8.3 Dimension drawings Dimension drawing of the KTP400 Basic color PN 8.3.4 $OOGLPHQVLRQVLQPP Basic Panels Operating Instructions, 04/2012, A5E02421799-03 125 Technical specifications 8.3 Dimension drawings 8.3.5 Dimension drawing of the KTP600 Basic color DP $OOGLPHQVLRQVLQPP Basic Panels 126 Operating Instructions, 04/2012, A5E02421799-03 Technical specifications 8.3 Dimension drawings 8.3.6 Dimension drawing of the KTP600 Basic mono/color PN $OOGLPHQVLRQVLQPP Basic Panels Operating Instructions, 04/2012, A5E02421799-03 127 Technical specifications 8.3 Dimension drawings 8.3.7 Dimension drawing of the KTP1000 Basic color DP $OOGLPHQVLRQVLQPP Basic Panels 128 Operating Instructions, 04/2012, A5E02421799-03 Technical specifications 8.3 Dimension drawings 8.3.8 Dimension drawing of the KTP1000 Basic color PN $OOGLPHQVLRQVLQPP Basic Panels Operating Instructions, 04/2012, A5E02421799-03 129 Technical specifications 8.3 Dimension drawings Dimension drawing of the TP1500 Basic color PN $OOGLPHQVLRQVLQPP 8.3.9 Basic Panels 130 Operating Instructions, 04/2012, A5E02421799-03 Technical specifications 8.4 Specifications 8.4 Specifications 8.4.1 Power supply CAUTION Safe electrical isolation Use only 24 VDC power supply units with safe electrical isolation in accordance with IEC 60364-4-41 or HD 384.04.41 (VDE 0100, Part 410), e.g. to PELV standard. The supply voltage must be within the specified voltage range. Otherwise, malfunction at the HMI device cannot be ruled out. Applies to non-isolated plant configurations: Connect the connection for GND 24 V from the 24 V power supply output to equipotential bonding for uniform reference potential. You should always select a central point of termination. The following table shows the permitted rated voltage and the corresponding tolerance range. 8.4.2 Rated voltage Tolerance range +24 VDC 19.2 to 28.8 V (-20%, +20%) KP300 Basic and KP400 Basic Weight Weight without packaging KP300 Basic mono PN KP400 Basic color PN Approx. 250 g Approx. 510 g KP300 Basic mono PN KP400 Basic color PN Display Type LCD mono FSTN LCD TFT Active display area 87 x 31 mm (3.6") 95 x 53.8 mm (4.3") 240 x 80 pixels 480 x 272 pixels Possible colors 4 (only backlighting: white, red, green, yellow) 256 Contrast control Yes No Brightness control No Yes Resolution Basic Panels Operating Instructions, 04/2012, A5E02421799-03 131 Technical specifications 8.4 Specifications KP300 Basic mono PN Backlighting Half Brightness Life Time (MTBF 1) Pixel error class according to DIN EN ISO 13406-2 KP400 Basic color PN LED 50,000 h - II MTBF: Operating hours after which the maximum brightness is reduced by half compared to the original value. MTBF is increased by using the integrated dimming function, for example, time-controlled via screen saver or centrally via PROFIenergy. 1 Input device KP300 Basic mono PN Type KP400 Basic color PN Membrane keyboard Function keys 10 8 Labeling strips No Yes KP300 Basic mono PN KP400 Basic color PN 512 KB 1024 KB KP300 Basic mono PN KP400 Basic color PN Memory Application memory Interfaces 1 x Ethernet RJ45 10/100 Mbps Supply voltage KP300 Basic mono PN Rated voltage KP400 Basic color PN +24 V DC Range, permissible 19.2 to 28.8 V (-20%, +20%) Transients, maximum permissible 35 V (500 ms) Time between two transients, minimum 50 s Current consumption * Typical Approx. 100 mA Approx. 100 mA * Constant current, maximum Approx. 150 mA Approx. 120 mA * Inrush current I2t A2s Approx. 0.5 A2s Approx. 0.5 Fuse, internal Electronic Miscellaneous KP300 Basic mono PN Software clock, synchronizable KP400 Basic color PN Yes Basic Panels 132 Operating Instructions, 04/2012, A5E02421799-03 Technical specifications 8.4 Specifications 8.4.3 KTP400 Basic and KTP600 Basic Weight KTP400 Basic mono PN Weight without packaging KTP400 Basic color PN KTP600 Basic mono PN KTP600 Basic color DP KTP600 Basic color PN Approx. 320 g Approx. 340 g Approx. 1070 g KTP400 Basic mono PN KTP400 Basic color PN KTP600 Basic mono PN LCD mono FSTN LCD TFT LCD mono FSTN Active display area 76.8 x 57.6 mm (3.8") 95 x 53.8 mm (4.3") 115.2 mm x 86.4 mm (5.7") Resolution 320 x 240 pixels 480 x 272 pixels 320 x 240 pixels Possible colors 4 grayscales 256 4 grayscales 256 Contrast control Yes No Yes No No Display Type Brightness control KTP600 Basic color PN LCD TFT No Yes LED LED CCFL Half Brightness Life Time (MTBF 1) 30,000 h 50,000 h 50,000 h Pixel error class according to DIN EN ISO 13406-2 - II Backlighting 1 KTP600 Basic color DP No - II MTBF: Operating hours after which the maximum brightness is reduced by half compared to the original value. MTBF is increased by using the integrated dimming function, for example, time-controlled via screen saver or centrally via PROFIenergy. Input device KTP400 Basic mono PN KTP400 Basic color PN Type KTP600 Basic mono PN KTP600 Basic color DP KTP600 Basic color PN Touch screen, analog resistive Function keys 4 6 Labeling strips Yes Memory KTP400 Basic mono PN Application memory KTP400 Basic color PN KTP600 Basic mono PN KTP600 Basic color DP KTP600 Basic color PN 512 KB Basic Panels Operating Instructions, 04/2012, A5E02421799-03 133 Technical specifications 8.4 Specifications Interfaces KTP400 Basic mono PN 1 x RS 422/RS 485 KTP400 Basic color PN KTP600 Basic mono PN - - - 1 x Ethernet RJ45 KTP600 Basic color DP KTP600 Basic color PN Max. 12 Mbps 10/100 Mbps - 10/100 Mbps Supply voltage KTP400 Basic mono PN KTP400 Basic color PN Rated voltage KTP600 Basic mono PN KTP600 Basic color DP KTP600 Basic color PN +24 V DC Range, permissible 19.2 to 28.8 V (-20%, +20%) Transients, maximum permissible 35 V (500 ms) Time between two transients, minimum 50 s Current consumption * Typical Approx. 100 mA Approx. 100 mA Approx. 240 mA Approx. 350 mA * Constant current, maximum Approx. 150 mA Approx. 120 mA Approx. 350 mA Approx. 550 mA Approx. 0.5 A2s Approx. 0.5 A2s Approx. 0.5 A2s Approx. 0.5 A2s * I2 t Inrush current Fuse, internal Electronic Miscellaneous KTP400 Basic mono PN Software clock, synchronizable KTP600 Basic mono PN KTP600 Basic color DP KTP600 Basic color PN Yes Basic Panels 134 Operating Instructions, 04/2012, A5E02421799-03 Technical specifications 8.4 Specifications 8.4.4 KTP1000 Basic and TP1500 Basic HMI device KTP1000 Basic color DP Weight without packaging KTP1000 Basic color PN TP1500 Basic color PN Approx. 2.65 kg Approx. 4.2 kg Display KTP1000 Basic color DP KTP1000 Basic color PN Type LCD TFT Display area, active 211.2 mm x 158.4 mm (10.4") 304.1 mm x 228.1 mm (15") 640 x 480 1024 x 768 Resolution, pixels 1 TP1500 Basic color PN Colors, displayable 256 Brightness control Yes Pixel error class according to DIN EN ISO 13406-2 II Backlighting Half Brightness Life Time (MTBF 1) CCFL 50,000 h MTBF: Operating hours after which the maximum brightness is reduced by half compared to the original value. MTBF is increased by using the integrated dimming function, for example, time-controlled via screen saver or centrally via PROFIenergy. Input device KTP1000 Basic color DP Type KTP1000 Basic color PN TP1500 Basic color PN Touch screen, analog resistive Function keys 8 function keys No Labeling strips Yes No Memory KTP1000 Basic color DP Application memory KTP1000 Basic color PN TP1500 Basic color PN 1024 KB Interfaces KTP1000 Basic color DP 1 x RS 422/RS 485 KTP1000 Basic color PN TP1500 Basic color PN Max. 12 Mbps - - RJ45 10/100 Mbps 1 x Ethernet Basic Panels Operating Instructions, 04/2012, A5E02421799-03 135 Technical specifications 8.4 Specifications Supply voltage KTP1000 Basic color DP KTP1000 Basic color PN Rated voltage TP1500 Basic color PN +24 V DC Range, permissible 19.2 to 28.8 V (-20%, +20%) Transients, maximum permissible 35 V (500 ms) Time between two transients, minimum 50 s Current consumption * Typical Approx. 600 mA Approx. 800 mA * Constant current, maximum Approx. 1000 mA Approx. 1000 mA * Inrush current I2t Approx. 0.2 A2s Approx. 0.2 A2s Fuse, internal Electronic Miscellaneous KTP1000 Basic color DP Software clock, synchronizable KTP1000 Basic color PN TP1500 Basic color PN Yes Basic Panels 136 Operating Instructions, 04/2012, A5E02421799-03 Technical specifications 8.4 Specifications 8.4.5 Ambient conditions 8.4.5.1 Transport and storage conditions Mechanical and climatic conditions for transportation and storage The transport and storage conditions of this HMI device exceed requirements in accordance with IEC 61131-2. The following specifications apply to the transport and storage of an HMI device in its original packaging. The climatic conditions conform to the following standards: IEC 60721-3-3, Class 3K7 for storage IEC 60721-3-2, Class 2K4 for transport Mechanical requirements conform to EC 60721-3-2, Class 2M2. Type of condition Permitted range Drop test (in transport package) 1m Temperature From -20 to +60 C Atmospheric pressure From 1080 hPa to 660 hPa, corresponds to an elevation of -1000 to 3500 m Relative humidity From 10 % to 90 %, without condensation Sinusoidal vibration in accordance with IEC 60068-2-6 5 to 8.4 Hz: 3.5 mm 8.4 to 500 Hz: 9.8 m/s2 Shock conforming to IEC 60068-2-29 250 m/s2, 6 ms, 1000 shocks NOTICE Ensure that no condensation (dewing) develops on or inside the HMI device after transporting it at low temperatures or after it has been exposed to extreme temperature fluctuations. The HMI device must have acquired room temperature before it is put into operation. Do not expose the HMI device to direct radiation from a heater in order to warm it up. If dewing has developed, wait approximately 4 hours until the HMI device has dried completely before switching it on. Proper transport and storage, installation and assembly as well as careful operation and maintenance are required to ensure trouble-free and safe operation of the HMI device. The warranty for the HMI device will be deemed void if these stipulations are not heeded. See also Notes about usage (Page 26) Basic Panels Operating Instructions, 04/2012, A5E02421799-03 137 Technical specifications 8.4 Specifications 8.4.5.2 Conditions of use Mechanical and climatic conditions of use The HMI device is designed for use in a location protected from the effects of the weather. The conditions of use are compliant with requirements to DIN IEC 60721-3-3: Class 3M3 (mechanical requirements) Class 3K3 (climatic requirements) Use with additional measures The HMI device should not be used at the following locations unless additional measures are taken: In locations with a high degree of ionizing radiation In locations with difficult operating conditions - for example due to: - Corrosive vapors, gases, oils or chemicals - Electrical or magnetic fields of high intensity In plants that require special monitoring - for example: - Elevators - Systems in especially hazardous rooms Mechanical ambient conditions The mechanical ambient conditions for the HMI device are specified in the following table in terms of sinusoidal vibration. Frequency range in Hz Constant Occasional 10 f 58 Amplitude 0.0375 mm Amplitude 0.075 mm 58 f 150 Constant acceleration 0.5 g Constant acceleration 1 g Reducing vibrations If the HMI device is subjected to greater shocks or vibrations, you must take appropriate measures to reduce acceleration or amplitudes. We recommend fitting the HMI device to vibration-absorbent material (on metal shock absorbers, for example). Basic Panels 138 Operating Instructions, 04/2012, A5E02421799-03 Technical specifications 8.4 Specifications Testing mechanical ambient conditions The following table provides information on the type and scope of tests for mechanical ambient conditions. Tested for Test standard Comments Vibrations Vibration test in accordance with IEC 60068, part 2-6 (sinusoidal) Type of vibration: Transitional rate of the frequency: 1 octave/minute. 10 Hz f 58 Hz, constant amplitude of 0.075 mm 58 Hz f 150 Hz, constant acceleration 1 g Vibration duration: 10 frequency cycles per axis at each of the three associated vertical axes Shock Shock test in accordance with IEC 60068, Part 2 -27 Type of shock: Half-sine Shock intensity: Peak value 15 g, duration 11 ms Direction of impact: 3 shocks in direction at each one of the three associated vertical axes Climatic ambient conditions The following table shows the climatic ambient conditions for operation of the HMI device. Ambient conditions Permitted range Comments Temperature * Vertical mounting From 0 to 50 C * Mounting at an angle From 0 to 40 C Slope angle max. 35 Relative humidity 10 to 90 %, without condensation Atmospheric pressure 1080 to 795 hPa Corresponds to an elevation of - 1,000 to 2,000 m Pollutant concentration SO2: < 0.5 ppm; Relative humidity < 60%, no condensation Test: 10 cm3/m3; 10 days H2S: < 0.1 ppm; Relative humidity < 60%, no condensation Test: 1 cm3/m3; 10 days Basic Panels Operating Instructions, 04/2012, A5E02421799-03 139 Technical specifications 8.4 Specifications 8.4.5.3 Information on insulation tests, protection class and degree of protection Test voltages Insulation strength is demonstrated in the type test with the following test voltages in accordance with IEC 61131-2: Circuits with a nominal voltage of Ue to other circuits or ground Test voltage < 50 V 500 VDC Protection class Protection Class I in accordance with IEC 60536, i.e. PE/ground terminal to profile rail required! Protection against foreign objects and water Degree of protection in accordance with IEC 60529 Explanation Front When mounted: Rear panel * IP65 * Front face only Type 4X/Type 12 (indoor use only) IP20 Touch protection test with standard test probes. There is no protection against ingress by water. The degree of protection at the front can only be guaranteed if the mounting seal is installed flush to the mounting cut-out. Read the corresponding information in section "Making the mounting cut-out". See also Making the mounting cut-out (Page 31) Basic Panels 140 Operating Instructions, 04/2012, A5E02421799-03 Technical specifications 8.5 Interface description 8.5 Interface description 8.5.1 Power supply Plug connector, 2-pin Pin number 8.5.2 Assignment 1 +24 VDC (L+) 2 GND 24 V (M) PROFIBUS (Sub-D RS422/485) Name of interface on HMI device: X2 Sub-D socket, 9-pin, with screw lock Pin Assignment for the RS 422 Assignment for the RS 485 1 n. c. n. c. 2 GND 24 V GND 24 V 3 TxD+ Data channel B (+) 4 RD+ RTS 5 GND 5 V, floating GND 5 V, floating 6 +5 VDC, floating +5 VDC, floating 7 +24 VDC, out (max. 100 mA) +24 VDC, out (max. 100 mA) 8 TxD- Data channel A (-) 9 RxD- NC Basic Panels Operating Instructions, 04/2012, A5E02421799-03 141 Technical specifications 8.5 Interface description 8.5.3 PROFINET (Ethernet) Name of interface on HMI device: X1 RJ45 plug connector Pin Assignment 1 Tx+ 2 Tx- 3 Rx+ 4 n. c. 5 n. c. 6 Rx- 7 n. c. 8 n. c. Meaning of LEDs State Green "SPEED" LED Yellow "LINK" LED On 1 Off No connection 1 10 MB connection Off On 100 MB connection On On Active data transfer 10 MB Off Flashing Active data transfer 100 MB On Flashing For KTP1000 Basic and TP1500 Basic: Off Basic Panels 142 Operating Instructions, 04/2012, A5E02421799-03 Technical specifications 8.6 Functional scope with WinCC flexible and WinCC 8.6 Functional scope with WinCC flexible and WinCC The following tables show the objects that can be integrated in a project for a Basic Panel. Alarms Object Specification Basic Panels Alarms Number of discrete alarms 200 Number of analog alarms 15 Length of the alarm text 80 characters Number of tags in an alarm Max. 8 Display Alarm window, alarm view Acknowledge error alarm individually Yes Acknowledge multiple error alarms simultaneously (group acknowledgement) 16 acknowledgment groups Edit alarm Yes Alarm indicator Alarm buffer Yes Alarm buffer capacity 256 alarms Simultaneously queued alarm events Max. 64 View alarm Yes Delete alarm buffer Yes Tags, values and lists Object Specification KP300 Basic mono PN KP400 Basic color PN KTP400 Basic mono PN KTP400 Basic color PN KTP600 Basic mono PN KTP600 Basic color DP/PN KTP1000 Basic color DP/PN TP1500 Basic color PN Tags Quantity 250 500 Limit value monitoring Input/output Yes Linear scaling Input/output Yes Text lists Quantity 150 Screens Object Specification Screens Quantity 50 Fields per screen 30 Tags per screen 30 Complex objects per screen (for example, bars) 5 Template Basic Panels Yes Basic Panels Operating Instructions, 04/2012, A5E02421799-03 143 Technical specifications 8.6 Functional scope with WinCC flexible and WinCC Recipes The specified values are maximum values and should not be used additive. Object Specification Recipes Quantity Basic Panels 5 Elements per recipe 20 Data records per recipe 20 Safety Object Specification Basic Panels Safety Number of user groups 50 Number of users 50 Number of authorizations 32 Infotexts Object Specification Basic Panels Infotexts Length (no. of characters) 320 For alarms Yes For screens Yes For screen objects (for example, for I/O field, switch, button, invisible button) Yes Additional functions Object Specification Screen settings Touch screen calibration Brightness setting Contrast setting Basic Panels mono Yes Basic Panels color Yes 1 1 - Yes 2 Yes - Language change Number of languages 5 Graphic objects Vector and pixel graphics Trend views Quantity max. 25 Trends per view Quantity max. 4 Text objects Quantity 500 Yes 1 Not KP300 Basic mono PN and KP400 Basic color PN 2 Not KTP600 Basic mono PN, KTP600 Basic color PN, KTP600 Basic color DP Basic Panels 144 Operating Instructions, 04/2012, A5E02421799-03 Technical specifications 8.6 Functional scope with WinCC flexible and WinCC New system functions In addition to the system functions already available, WinCC flexible 2008 SP2 and WinCC V11 or higher support the following system functions for the Basic Panels: 1 System function/syntax Application SetBitInTag (Tag, Bit) Sets a bit in the specified tag to 1 (TRUE). ReSetBitInTag (Tag, Bit) Sets a bit in the specified tag to 0 (FALSE). InvertBitInTag (Tag, Bit) Inverts a bit in the specified tag. SetColorBackgroundLighting (value) 1) Specifies the color for the backlighting. KP300 Basic mono PN only For more information, refer to "System functions" in the the Online Help of WinCC flexible and WinCC. Basic Panels Operating Instructions, 04/2012, A5E02421799-03 145 Technical specifications 8.6 Functional scope with WinCC flexible and WinCC Basic Panels 146 Operating Instructions, 04/2012, A5E02421799-03 Technical Support A.1 A Service and support You can find additional information and support for the products described on the Internet at the following addresses: Technical support (http://www.siemens.de/automation/csi_en_WW) Support request form (http://www.siemens.com/automation/support-request) After-sales information system for SIMATIC PC / PG (http://www.siemens.com/asis) SIMATIC Documentation Collection (http://www.siemens.com/simatic-tech-doku-portal) Your local representative (http://www.automation.siemens.com/mcms/aspa-db/en/Pages/default.aspx) Training center (http://sitrain.automation.siemens.com/sitrainworld/?AppLang=en) Industry Mall (http://mall.automation.siemens.com) When contacting your local representative or Technical Support, please have the following information at hand: Order number of the device (MLFB) BIOS version (industry PC) or image version (HMI device) Installed additional hardware Installed additional software Tools & downloads Please check regularly if updates and hotfixes are available for download to your device. The downloads are available on the Internet under "After Sales Information System SIMATIC PC/PG" (see above). Basic Panels Operating Instructions, 04/2012, A5E02421799-03 147 Technical Support A.2 System events A.2 System events System events on the HMI device provide information about internal states of the HMI device and PLC. Note System events are only indicated if an alarm window was configured. System events are output in the language currently set on your HMI device. System event parameters System events may contain encrypted parameters which are relevant to troubleshooting because they provide a reference to the source code of the runtime software. These parameters are output after the text "Error code:" Description of the system events A listing of all system alarms for your HMI device is provided in the Online Help of your configuration software. Basic Panels 148 Operating Instructions, 04/2012, A5E02421799-03 B Abbreviations ANSI American National Standards Institution CPU Central Processing Unit CSV Comma Separated Values CTS Clear To Send DC Direct Current DCD Data Carrier Detect DHCP Dynamic Host Configuration Protocol DIL Dual-in-Line (electronic chip housing design) DNS Domain Name System DP Distributed I/O DSN Data Source Name DSR Data Set Ready DTR Data Terminal Ready IO Input and Output ESD Components and modules endangered by electrostatic discharge EMC Electromagnetic Compatibility EN European standard ES Engineering System ESD Components and modules endangered by electrostatic discharge GND Ground HF High Frequency HMI Human Machine Interface IEC International Electronic Commission IF Interface IP Internet Protocol LED Light Emitting Diode MAC Media Access Control MOS Metal Oxide Semiconductor MPI Multipoint Interface (SIMATIC S7) MS Microsoft MTBF Mean Time Between Failures n. c. Not connected NTP Network Time Protocol OP Operator Panel PC Personal Computer PG Programming device PPI Point-to-Point Interface (SIMATIC S7) RAM Random Access Memory Basic Panels Operating Instructions, 04/2012, A5E02421799-03 149 Abbreviations PELV Protective Extra Low Voltage RJ45 Registered Jack Type 45 RTS Request to send RxD Receive Data SD Card Security Digital Card SELV Safety Extra Low Voltage SP Service Pack PLC Programmable Logic Controller STN Super Twisted Nematic Sub-D Subminiature D (plug) TAB Tabulator TCP/IP Transmission Control Protocol/Internet Protocol TFT Thin Film Transistor TTY Teletype TxD Transmit Data UL Underwriter's Laboratory USB Universal Serial Bus UPS Uninterruptible power supply WINS Windows Internet Naming Service Basic Panels 150 Operating Instructions, 04/2012, A5E02421799-03 Glossary "Transfer" mode HMI device operating mode for transferring an executable project from the configuring PC to an HMI device. Acknowledge Acknowledgment of an alarm confirms that it has been noted. Alarm, acknowledgment Acknowledgment of an alarm confirms that it has been noted. Alarm, activated Moment at which an alarm is triggered by the PLC or HMI device. Alarm, deactivated Moment at which the initiation of an alarm is reset by the PLC. Alarm, user-specific User-specific alarms report specific states of a plant that is interconnected with the HMI device via the PLC. Automation system An automation system is a PLC of the SIMATIC S7 product line, e.g. SIMATIC S7-300 Boot loader The boot loader is used to start the operating system and is started automatically after power on of the HMI device. The Loader is displayed after the operating system has loaded. Configuration software The configuration software is used to create projects for process visualization. WinCC flexible is such a configuration software, for example. Basic Panels Operating Instructions, 04/2012, A5E02421799-03 151 Glossary Configuring PC A configuring PC is a programming device or PC on which plant projects are created using an engineering software. Display duration Defines whether a system alarm is displayed on the HMI device and the duration of the display. EMC Electromagnetic compatibility is the ability of electrical equipment to function properly in its electromagnetic environment without influencing this environment. Event Incoming events trigger defined functions. Events can be configured. Events which can be assigned to a button include "Press" and "Release", for example. Field Area reserved in configured screens for the input and output of values. Flash memory Flash memory is a non-volatile memory with EEPROM chips that is implemented either as mobile storage medium, or as permanently installed memory module on the motherboard. Function key Function keys on the HMI device can be assigned user-specific functions. The functions assigned to those keys are defined in the engineering phase. The function key assignment can be specific to an active screen or not. Half Brightness Life Time Time period after which brightness is reduced to 50% of the original value. The specified value depends on the operating temperature. HMI device HMI devices are used to operate and monitor machinery and plants. The machine or plant states are visualized on the HMI device by means of graphic objects or signal lamps. The operator controls of the HMI device enable intervention in machine or plant processes and sequences. Basic Panels 152 Operating Instructions, 04/2012, A5E02421799-03 Glossary HMI device image The HMI device image is a file that can be transferred from the configuring PC to the HMI device. The HMI device image contains the operating system of the HMI device , including the elements of the Runtime software required for the executable project file. I/O field Enables the input or output of values on the HMI device and their transfer to the PLC. Infotext A configured infotext provides information about objects within a project. An alarm infotext, for example, can contain information on the cause and troubleshooting of faults. Object An object is a project element such as a screen or an alarm. Objects are used to view or enter texts and values on the HMI device. Operating element An operating element is a project component that is used to enter values and trigger functions. A button is such an operating element. Plant General term referring to machinery, processing centers, systems, plants and processes which are operated and monitored using an HMI device. PLC PLC is a general term for devices and systems with which the HMI device communicates, e.g. SIMATIC S7. PLC job A PLC job triggers a function at the HMI device. Process visualization Denotes visualization of technical processes by means of text and graphic elements. Configured plant screens enable intervention in runtime plant processes by means of data input and output. Basic Panels Operating Instructions, 04/2012, A5E02421799-03 153 Glossary Project A project is the result of a configuration using an engineering software. The project usually contains several screens with embedded system-specific objects, basic settings and alarms. A project configured in WinCC flexible is saved to a project file with the extension *.hmi. There is a difference between an offline project on a configuring PC and an online executable project on an HMI device. A project can be available in more languages on the configuring PC than can be managed on the HMI device. The project on the configuring PC can also be set up for different HMI devices. However, on the HMI device you can only transfer the executable project that has been generated specifically for this HMI device. Project file Source file from which the executable project file for the HMI device is generated. The project file is usually not transferred and is retained on the configuring PC. Project file, compressed Compressed format of the project file. The compressed project file can be transferred in addition to the executable project file to the corresponding HMI device. The upload function must be activated accordingly on the configuring PC at the time of the transfer. The compressed project file is usually saved to an external memory card. A compressed project file has the extension *.pdz. Project file, executable An executable project file is generated from the project file for a specific HMI device in the course of engineering. The executable project file is transferred to the associated HMI device where it is used to operate and monitor plants. ProSave ProSave provides all functions necessary to transfer data between the configuring PC and the HMI device. For example, saving and restoring data or managing license keys and addons. ProSave is installed by default together with WinCC flexible or WinCC. The standalone version of ProSave can also be used for service purposes on a PC without WinCC flexible installation. The standalone version is available on the installation DVD of WinCC flexible. Recipe A recipe represent a combination of tags that form a fixed data structure. The configured data structure can be assigned data in the configuration software or on the HMI device and is then referred to as a data record. The use of recipes ensures that all data assigned to a data record is transferred synchronously to the PLC. Basic Panels 154 Operating Instructions, 04/2012, A5E02421799-03 Glossary Runtime software The Runtime software is a process visualization software which can be used to test projects on a configuring PC. Screen Mode of visualization of all logically associated process data of a plant. Visualization of the process data can be supported by means of graphic objects. Screen object Refers to objects such as rectangles, I/O fields, or alarm views which are configured for visualization or operation of the plant. STEP 7 STEP 7 is the programming software for SIMATIC S7, SIMATIC C7 and SIMATIC WinAC PLCs. STEP 7 Micro/WIN STEP 7 Micro/WIN is the programming software for SIMATIC S7-200 PLCs. Symbolic I/O field Symbolic I/O fields are used for the input and output of values. A field contains a list of default entries from which one can be selected. System alarms System alarms are assigned the "System" alarm class. A system alarm reports internal states of the HMI device and of the PLC. Tab order The tab order defined in the course of project engineering determines the sequence for activating objects by pressing the key. Tags A tag is a defined memory area that is used to read and write values. Those tags can be accessed from the PLC or using the HMI device. We distinguish between external tags (process tags) and internal tags, depending on whether or not the tag is interconnected with the PLC. Basic Panels Operating Instructions, 04/2012, A5E02421799-03 155 Glossary Transfer Transfer of an executable project from the configuring PC to the HMI device. WinCC WinCC (TIA Portal) is engineering software for configuring SIMATIC Panels, SIMATIC Industrial PC and standard PC with the visualization software WinCC Runtime Advanced or the SCADA system, WinCC Runtime Professional. A project created with WinCC has the file extension "*.ap11". An executable project file on a HMI device has the extension "*.fwx". WinCC flexible WinCC flexible is an engineering software for configuring SIMATIC Panels, SIMATIC Industrial PC and Standard PC in machine-related areas with the visualization software WinCC flexible Runtime. A project created with WinCC flexible has the file extension "*.hmi". An executable project file on a HMI device has the extension "*.fwx". Basic Panels 156 Operating Instructions, 04/2012, A5E02421799-03 Index A ACK key, 65 Acknowledge key, 65 Activating Automatic transfer, 84 Ambient conditions Climatic, 139 Mechanical, 138 Test, 139 Approval for Australia, 117 Approvals, 117 Automatic transfer Activating, 84 B Backspace key, 64 Backup, 91, 96, 97, 99 Data of the HMI device, 100 With ProSave, 99 with WinCC, 100 With WinCC flexible, 97 Basic knowledge Required, 4 C Cancel key, 64 Care, 115 CE approval, 117 Checking Conditions of use, 138 Electromagnetic Compatibility, 118 Package content, 29 Standards and approvals, 117 Transport and storage conditions, 137 Clamping frame, 23 Climatic Storage conditions, 137 Transport conditions, 137 Clock KP300 Basic, 132 KTP1000 Basic, TP1500 Basic, 136 KTP400 Basic, KTP600 Basic, 134 Commissioning engineers, 3 Compatibility conflict, 96 Components sensitive to electrostatic charge, 119 Conductor cross-section Equipotential bonding, 38 Configuration phase, 89 Configuring MPI/Profibus Settings, 69 Network settings, 70 RS422/RS485 port, 46 Time server, 71, 86 Configuring PC, 89 Connecting Configuring PC, 42 Equipotential bonding, 38 PLC, 45 Power supply, 40 Programming device, 41 Control cabinet Working on, 25 Control Panel Menu structure, 81 Opening, 67 Overview, 68, 81 Password protection, 68, 80 Cursor key, 64 D Data channel Enabling, 84 Locking, 84 Decimal places, 56, 58, 63 Degree of protection Protection against ingress of solid foreign bodies, 140 Protection against water, 140 Delete key, 64 DIP switch Setting, 46 Basic Panels Operating Instructions, 04/2012, A5E02421799-03 157 Index Display KP300 Basic, 131 KTP1000 Basic, TP1500 Basic, 135 KTP400 Basic, KTP600 Basic, 133 Disposal, 116 Disturbance Pulse-shaped, 118 Sinusoidal, 119 E EC Declaration of Conformity, 117 Elbow adapter, 23 Electrical isolation, 131 Electrical potential difference, 38 EMC directive, 117 Emission, 26, 119 Enabling Data channel, 84 Enabling a data channel, 68 END key, 64 Enter key, 64 ENTER key, 64 Equipotential bonding Cable, 38 Connecting, 38 Requirements, 38 Wiring diagram, 39 ESC key, 64 ESD, 119 ESD guidelines, 119 F Factory setting With ProSave, 112 with WinCC, 114 With WinCC flexible, 110 Figures, 5 Functional scope Alarm buffer, 143 Alarms, 143 Graphic objects, 144 Infotext, 144 Language change, 144 Limit value monitoring, 143 Recipes, 144 Safety, 144 Scaling, 143 Screen settings, 144 Screens, 143 Tags, 143 Text lists, 143 Text objects, 144 Trend views, 144 G Guidelines ESD guidelines, 119 H High frequency radiation, 25 HMI device Connecting, 36 Data backup, 100 EMC-compatible installation, 118 Mounting, 34 Restoring data, 101 Shutting down, 49 Switching on, 48 Technical specifications, 131, 133, 135 Testing, 48 Updating the operating system, 109 HOME key, 64 I Illustrations, 5 Infotext Key, 65 Initial startup, 89 Input device KP300 Basic, 132 KTP1000 Basic, TP1500 Basic, 135 KTP400 Basic, KTP600 Basic, 133 Installation as intended, 25 Insulation test, 140 Basic Panels 158 Operating Instructions, 04/2012, A5E02421799-03 Index Interfaces KP300 Basic, 132 KTP1000 Basic, TP1500 Basic, 135 KTP400 Basic, KTP600 Basic, 134 IT Security, 26 K Key ACK, 65 Cancel, 64 Cursor, 64 Delete, 64 END, 64 ENTER, 64 ESC, 64 HOME, 64 Infotext, 65 Scroll back, 64 Scroll forward, 64 SHIFT, 64 Switching, 64 L Labeling Approvals, 117 EC Declaration of Conformity, 117 Limit value check, 56, 58, 62 List of abbreviations, 149 Locking Data channel, 84 M Maintenance, 115 Maintenance technicians, 3 Mechanical Ambient conditions, 138 Storage conditions, 137 Transport conditions, 137 Memory KP300 Basic, 132 KTP1000 Basic, TP1500 Basic, 135 KTP400 Basic, KTP600 Basic, 133 Mounting EMC-compatible, 118 HMI device, 34 Mounting clamp Aluminum, 35 Plastic, 36 MPI/Profibus Settings, 68 N Non-isolated plant configuration, 131 O Offline Operating mode, 90 Test, 95 Online Operating mode, 90 Test, 96 OP properties Device, 68 Display, 68 License, 68 Touch, 68 Operating Control Panel with system keys, 65 Dialog with system keys, 65 Keyboard unit, 63 Project with system keys, 65 Operating instructions Purpose of, 3 Scope, conventions, 4 Operating mode, 90 Changing, 90 Offline, 90 Online, 90 Transfer, 90 Operating system Update using ProSave, 104, 108 Update using WinCC flexible, 103 Updating, 101, 105 Updating using WinCC flexible, 107 Operators, 3 Basic Panels Operating Instructions, 04/2012, A5E02421799-03 159 Index P S Package content Checking, 29 Password properties, 68 Password protection, 68, 80 Activating, 78, 87 Deactivating, 78, 87 PELV, 131 Plant configuration Non-isolated, 131 PLC Configuring the interface, 46 Power failure, 96 Process control phase, 89 PROFIBUS connector, 23 PROFINET connector, 23 Profinet Settings, 68 Project Offline testing, 95 Testing online, 96 Transferring, 89 Protection class, 140 Protective foil, 24 Protective measure Static electricity, 121 Safe electrical isolation, 131 Safety Standards, 117 Safety instruction Compatibility conflict, 96 Data channel, 102, 106 Data loss, 101, 105 Equipotential bonding cable, 38 General, 26 High frequency radiation, 25 Operation indoors, 26 Power failure, 96 Preventing inadvertent operation, 115 Storage, 137 Transport, 137 unauthorized cleaning products, 115 Unintentional response, 115 Working on the control cabinet, 25 Safety regulations, 25 Screen keyboard Alphanumerical, 55, 57 Key assignment, 55, 57 KTP400 Basic, 54 KTP600 Basic, KTP1000 Basic, TP1500 Basic, 57 Numerical, 56, 58 Screen saver, 68 Screen settings Editing, 68 Scroll back key, 64 Scroll forward key, 64 Securing device with aluminum mounting clamps, 35 with plastic mounting clamps, 36 Security information, 26 Service packages, 24 Service technicians, 3 Shift key, 64 SHIFT key, 64 Shutting down HMI device, 49 Sound Settings, 68 Spare part Plastic clamp, 24 Power supply terminal, 24 Static electricity Protective measures, 121 R Radiation High frequency, 25 Radio interference, 26 Emission, 119 Rated voltage, 131 Recommissioning, 89 Recycling, 116 Registered trademarks, 6 Regulations for the prevention of accidents, 25 Restore, 91, 96, 100 With ProSave, 100 Restoring, 98 Data of the HMI device, 101 with WinCC, 101 With WinCC flexible, 98 Restoring data HMI device, 101 RS 422 to RS 232 converter, 23 RS422/RS485 port Configuring, 46 Basic Panels 160 Operating Instructions, 04/2012, A5E02421799-03 Index Storage conditions, 137 Strain relief, 50 Stripping, 39 Supply voltage KP300 Basic, 132 KTP1000 Basic, TP1500 Basic, 136 KTP400 Basic, KTP600 Basic, 134 Switching on HMI device, 48 System events in the online help, 148 Parameters, 148 System keys Operating a dialog, 65 Operating a project, 65 Operating the Control Panel, 65 U UL approval, 117 Update Using WinCC flexible, 103 Updating Operating system, 101, 105 Operating system of the HMI device, 109 Using ProSave, 104, 108 Using WinCC flexible, 107 with WinCC, 109 Usage Conditions, 138 With additional measures, 138 USB/PPI cable, 23 Use In residential areas, 26 Industrial, 26 T Technical specifications Display, 131, 133, 135 Input device, 132, 133, 135 Interfaces, 132, 134, 135 Memory, 132, 133, 135 Supply voltage, 132, 134, 136 Test Power supply, 131 Testing HMI device, 48 Time server Configuring, 86 Time Server Configuration, 68 Trademarks, 6 Transfer, 89, 90, 91 Automatic, 93 Manual, 91 Transfer settings, 68 Transferring Project, 89 Transport conditions, 137 V Vibrations, 138 W Weight KP300 Basic, 131 KTP1000 Basic, TP1500 Basic, 135 KTP400 Basic, KTP600 Basic, 133 Working on the control cabinet, 25 Basic Panels Operating Instructions, 04/2012, A5E02421799-03 161 Index Basic Panels 162 Operating Instructions, 04/2012, A5E02421799-03