AGM1232G SERIES GRAPHIC MODULE
AZ DISPLAYS, INC. 04/26/01 11
12.0 DISPLAY CONTROL INSTRUCTION
The display control instructions control the internal state of the SED1520DOA/FOA. Instructions are
received from MPU to SED1520DOA/FOA for the display control.
INSTRUCTION A0 R/W DB7 DB6 DB5 DB4 DB3 DB2 DB1 DB0 DESCRIPTION
Display ON/OFF 0 0 1 0 1 0 1 1 1 1/0 Turns display on or off.
0: OFF. 1:ON
Set Page Address 0 0 1 0 1 1 1 0 Page (0~3) Sets display RAM Page in
Page address register
Set Column
(Segment address) 0 0 0 Column address (0~79)
Sets display RAM column
address in column address
register
Display Start
Line 0 0 1 1 0 Display start line (0~31)
Indicates the display data
RAM displayed at the top of
the screen.
Status Read 0 1
BUSY
ADC
ON/OFF
RESET
00 0 0
Reads the following status:
BUSY 0: Ready
1: Busy
ADC 1: CW output
0: CCW output
ON/OFF 0: Display on
1: Display off
RESET 0: Normal
1: Being Reset
Write Display Data 1 0 Write Data Writes data DB0~DB7 from
bus into display data RAM.
Read Display Data 1 1 Read Data
Reads data DB0~DB7 from
display data RAM onto the
data bus.
Select ADC 0 010100000/10: CW output,1: CCW output
Static drive ON/OFF 0 010100100/1
1: Static drive,
0: Normal driving
Select duty 0 010101000/1
Select LCD duty cycle
1:1/32, 0: 1/16
Read-Modify-Write 0 011100000Read-Modify-write ON
END 0 011101110Read-Modify-write OFF
Reset 0 011100010Software reset