60WAC-DC High Reliability Slim Wall-mountedAdaptor SGA60U series
Features Applications
Model Encoding
-U05SGA P1J60
Series name
Output wattage
US 2 pin AC plug
Output voltage
DC plug type
Description
File Name:SGA60U-SPEC 2015-05-05
Ultra slim
Universal AC input / Full range
2 pole USA plug
No load power consumption< 0.075W for 5~7.5V
<0.15W for 9 ~48V
Energy efficiency Level
Comply with EISA 2007/DoE
Class power (without earth pin)
Protections: Short circuit / Overload / Over voltage
Fully enclosed plastic case
Pass LPS
LED indicator for power on
3 years warranty
Consumer electronic devices
Telecommunication devices
Office facilities
Industrial equipments
SGA60U is a 60W ultra slim wall-mounted style single-output green adaptor series, which is compact and
convenient for carry. SGA60U is a class power unit (without FG) equipped with the standard 2-Pin U.S.
plug, accepting the input range from 90VAC to 264VAC. The whole series provides different models with
output voltages ranging between 5VDC and 48VDC that it can satisfy the demands for various types of
consumer electronic devices.
With the efficiency up to 91% and the extremely low no-load power consumption below 0.075W for 5~7.5V,
below 0.15W for 9 ~48V, SGA60U is compliant with the latest U.S. energy regulation EISA 2007/DoE(Level ).
The supreme feature allows the adaptor to save the energy when it is under either the operating mode or
the standby mode. The entire series is approved for international safety regulations; moreover, it adopts
the 94V-0 flame retardant plastic case that it can effectively prevent users from electric hazards.
C+ tuning fork type
P1J: Plug for standard model, 2.1 5 5 11mm,ψ× ψ×.
Optional plug type available per request
{
SPECIFICATION
60WAC-DC High Reliability Slim Wall-mountedAdaptor SGA60U series
File Name:SGA60U-SPEC 2015-05-05
ORDER NO.
SAFETY MODEL NO.
DC VOLTAGE Note.2
RATED CURRENT
CURRENT RANGE
RATED POWER (max.)
RIPPLE & NOISE (max.) Note.3
OUTPUT
SETUP, RISE, HOLD UP TIME
VOLTAGE RANGE Note.7
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT
INPUT
ENVIRONMENT
INRUSH CURRENT (max.)
LEAKAGE CURRENT(max.)
SAFETY STANDARDS
SAFETY &
EMC
(Note. 8)
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
LIFE
MTBF
DIMENSION
OTHERS
NOTE
PACKING
PROTECTION
5V 9V7.5V 12V 15V 18V 24V 48V
SGA60U05 SGA60U09SGA60U07 SGA60U12 SGA60U15 SGA60U18 SGA60U24 SGA60U48
SGA60U05-P1J
SGA60U09-P1JSGA60U07-P1J
SGA60U12-P1J
SGA60U15-P1J
SGA60U18-P1J
SGA60U24-P1J
SGA60U48-P1J
6A 5.5A6A 5A 4A 3.33A 2.5A 1.25A
0 ~ 6A 0 ~ 5.5A0 ~ 6A
0 ~ 5A
0 ~ 4A 0 ~ 3.33A 0 ~ 2.5A
80mVp-p 80mVp-p80mVp-p 80mVp-p 80mVp-p 80mVp-p 100mVp-p 120mVp-p
VOLTAGE TOLERANCE Note.4
LINE REGULATION Note.5
LOAD REGULATION Note.6
±5.0% ±5.0%±5.0% ±3.0% ±3.0% ±2.0% ±2.0% ±2.0%
±1.0% ±1.0%±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0%
±5.0% ±5.0%±5.0% ±3.0% ±3.0% ±2.0% ±2.0% ±2.0%
90 ~ 264VAC
47 ~ 63Hz
1.5A / 115VAC 0.75A / 230VAC
40A / 115VAC 80A / 230VAC
0.25mA / 240VAC
UL60950-1, CSA C22.2 approved
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:4242VDC
I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH
3 years : 100% load 40 , 12hours / day
400Khrs min. MIL-HDBK-217F(25 )
-20 ~ +50 (Refer to "Derating Curve")
20% ~ 90% RH non-condensing
-20 ~ +85 , 10 ~ 95% RH
±℃0.03% / (0 ~ 40 )
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
93.5*35*51.5mm (L*W*H)
250g ; 60pcs / 17kg / CARTON
CONNECTOR
PLUG
CABLE
30W 49.5W45W 60W 60W 60W 60W 60W
0 ~ 1.25A
1.All parameters are specified at 115VAC input, rated load, 25 70% RH ambient.
2.DC voltage: The output voltage set at point measure by plug terminal & 50% load.
3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
4.Tolerance: includes set up tolerance, line regulation, load regulation.
5.Line regulation is measured from low line to high line at rated load.
6.Load regulation is measured from 10% to 100% rated load.
7.Derating may be needed under low input voltages. Please check the static characteristics for more details.
8.The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the
EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)
OVERLOAD
OVER VOLTAGE
110 ~ 200% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
110 ~ 140% rated output voltage
Protection type : Clamp by zener diode, output short
500ms, 50ms, 12ms/230VAC 500ms, 50ms, 12ms/115VAC at full load
84% 87%86% 88% 87% 88% 88% 91%
See page 3 ; Other type available by customer requested
See page 3 ; Other type available by customer requested
Compliance to FCC PART15/CISPR22 Class B
EMC EMISSION
Derating Curve Static Characteristics
Mechanical Specification
Installation Manual
Please refer to : http://www.meanwell.com/webnet/search/InstallationSearch.html
Ta ( )
LOAD (%)
-20 10 20 30 40
70
100
LOAD (%)
50
INPUT VOLTAGE
90 115100 130120 160140 200180 240220 264
90
100
80
70
60
50
40
Plug Assignment
Standard plug: P1J
P/N OUTPUT
P1J
CENTER +
60WAC-DC High Reliability Slim Wall-mountedAdaptor SGA60U series
File Name:SGA60U-SPEC 2015-05-05
Unit:mm
UL1571 16AWG 1000 50mm for 12V±
UL1571 14AWG 1000 50mm for 5~9V±
UL1185 18AWG 1500 50mm for 24~48V±
UL1185 16AWG 1000 50mm for 15~18V±
93.5
35
11 0.5mm±
51.5
ID 2.1 x OD 5.5
C"+"
InsideOutside
Mouser Electronics