Contact Nexans - Building activity contact.fr@nexans.com H07ZZ-F - ALSECURE FLEX H07ZZ-F ALSECURE FLEX 5G1 Nexans ref.: 10056500 Country ref.: 01080979 EAN 13: 3427680008282 Halogen free and fire retardant flexible cable. Rubber cables. Oil resistant and fire behaviour according to IEC/EN 60332-3 (cat C) standard. Description Application This cable is particularly recommended for all installations in which safety conditions require the use of a flexible and low smoke cable : * * * * * * * * * wiring for industrial installations, wiring for road and rail tunnels, wiring for industrial warehouses, wiring for rooms containing electrical, electronic or computer equipment, wiring for central control rooms, wiring for airports stations, port facilities and ships wiring for hospitals, wiring for buildings open to the public, wiring for house and tall buildings. Nota Max continuous operating conductor temperature in normal use : +60C ( in every case of mobile installation) +90C ( fixed protected installation ) +250C ( in short circuit ) Permissible current rating is measured for an ambient temperature of 30C and a maximum operating and conductor temperature of 90C . For other temperature please refer to correction factors . Standards International EN 50525-3-21 Halogen free IEC 60754-1 Lead free Yes Conductor flexibility Flexible class 5 Rated Voltage Uo/ U (Um) 450 / 750 V Mechanical resistance to impacts Good Generated 2/7/16 - http://www.nexans.fr Fire retardant IEC 60332-3 Cat.C Gases toxicity IEC 60754-2 Operating temp. range -5 .. 65 C Page 1 / 3 All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact Nexans - Building activity contact.fr@nexans.com H07ZZ-F - ALSECURE FLEX H07ZZ-F ALSECURE FLEX 5G1 Nexans ref.: 10056500 Characteristics Construction characteristics Halogen free IEC 60754-1 Lead free Yes Conductor material Copper Conductor flexibility Flexible class 5 Insulation Cross-linked synthetic elastomer type EI 8 Outer sheath Cross-linked synthetic elastomer type EM 8 With Green/Yellow core Yes Sheath colour Black With smaller neutral conductor No Dimensional characteristics Number of cores 5 Conductor cross-section 1 mm Conductor diameter 1.3 mm Minimum outer diameter 10.2 mm Maximum outer diameter 13.1 mm Approximate weight 180 kg/km Electrical characteristics Rated Voltage Uo/U (Um) 450 / 750 V Perm. current rating in air 30C - flat formation Voltage drop, 3 conductors 16 A 34.0 V/A.km Mechanical characteristics Mechanical resistance to impacts Good Usage characteristics Fire retardant IEC 60332-3 Cat.C Gases toxicity IEC 60754-2 Operating temperature, range -5 .. 65 C Max. conductor temperature in service 90 C Bending factor when laying 3 (xD) Dynamic bending factor 6 (xD) U.V resistance Very good Flame retardant IEC 60332-1-2 Generated 2/7/16 - http://www.nexans.fr Page 2 / 3 All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans. Contact Nexans - Building activity contact.fr@nexans.com H07ZZ-F - ALSECURE FLEX H07ZZ-F ALSECURE FLEX 5G1 Nexans ref.: 10056500 New cores identification Core identification in accordance with HD 308 S2 - Identification of cores in cables and flexible cords. Number of cores HD 308 S2 since january 2004 G (earth core) X (without earth core) 1 Black (preferential) 2 Blue + Brown 3* Green - Yellow + Blue + Brown 3** Brown + Black + Grey Blue + Brown + Black 4 Green - Yellow + Brown + Black + Grey Blue + Brown + Black + Grey 5 Green - Yellow + Blue + Brown + Black + Grey Blue + Brown + Black + Grey + Black White printed numbers + 1 Green - Yellow White printed numbers > 5 * For the cables without Green/Yellow with a cross-section >4mm ** For the cables without Green/Yellow with a cross-section of 1,5mm & 2,5mm Selling information when this type of cable is accessible to people during operation, it is recommended that steps are taken to ensure that the temperature of its outer sheath does not exceed 50C. Generated 2/7/16 - http://www.nexans.fr Page 3 / 3 All drawings, designs, specifications, plans and particulars of weights, size and dimensions contained in the technical or commercial documentation of Nexans is indicative only and shall not be binding on Nexans or be treated as constituting a representation on the part of Nexans.