1
New Product
A22E Common NoteA22NE-P
Common Accessories and Tools
Install in 22-dia. or 25-dia.
Panel Cutout (When Using a Ring)
Direct opening mechanism to open the circuit when the
contact welds.
Safety lock mechanism prevents operating errors.
Lever for easily mounting and removing the Switch Blocks.
Finger protection mechanism on Switch Unit provided as a
standard feature.
Use 25-dia. ring to install in 25-dia. panel cutouts.
Types of Emergency Stop Pushbutton Switches
A22E Screw Terminal Block Types ................................... from page 2
A22NE-P Push-in Plus Terminal Block Types ........................ from page 16
Common Items
Common Accessories / Tools................................................... from page 32
Safety Precautions..................................................................... from page 37
For the most recent information on models that have been certified for
safety standards, refer to your OMRON website.
Be sure to read the "Safety Precautions" on pages 15,
28, and 37.
Emergency Stop Pushbutton Switches (22-dia. or 25-dia.)
A22E/A22NE-P
2
A22E A22NE-P Common Note
Common Accessories and Tools
Emergency Stop Pushbutton Switches (22-dia. or 25-dia.) Screw Terminal Block types
A22E
Install in 22-dia. or 25-dia. Panel Cutout
(When Using a Ring)
Increase wiring efficiency with three-row mounting of Switch
Units.
(with non-lighted Switch Blocks, three Units can be
mounted for multiple contacts).
Mounted using either open-type (fork-type) or closed-type
(round-type) crimp terminals.
Oil-resistant to IP65 (non-lighted models) / IP65 (lighted models).
A lock plate is provided as a standard feature to ensure that the
control box and switch are not easily separated.
Model Number Structure
Model Number Legend (Completely Assembled)........Shipped as a set which includes the Operation Unit, LED
Lamp (lighted model only), Mounting Latches, Switch
Block, and Lock Plate
Be sure to read the "Safety Precautions" on pages 15 and 37.
For the most recent information on models that have been certified for
safety standards, refer to your OMRON website.
1. Lighted/Non-lighted 4. Contacts
5. Configuration
3. LED Lamp voltage
Lighting unit (Direct lighting)
Lighting unit (Voltage-reduction lighting)
2. Operation Unit size (diameter)/Reset function
Code Description
None Non-lighted
LLighted *
Code
None
B
Configuration
Switch only
Note 1. NO: 1a-contact NC: 1b-contact
2. For details on the unit position, refer to the figure below.
Switch with Integrated Control Box
Code Size Description
MP 40 dia. Pull-reset
S 30 dia.
Turn-reset
M40 dia.
L60 dia.
Code Description Operating Voltage
Lighted
(LED) *
None Non-lighted ---
6 A
12 A 12 VAC/DC
6 VAC/DC
24 A 24 VAC/DC
* Equipped with 24-VAC/DC LED.
Code Operating Voltage
T2 200 VAC
T1 100 VAC
* Lighted Emergency
Stop Switches are
available only for the
medium (M). turn-reset
models.
6. Configuration
Code Configuration
Neither “EMO” nor “EMS” printed, arrows engraved in red.
“EMO” printed in white, arrows engraved in red.
“EMO” and arrows printed in white.
None
EMO-RD
EMO
“EMS” and arrows printed in white.
EMS
EMS-RD “EMS” printed in white, arrows engraved in red.
Lighted
(LED) *
Description
(Example: A22EL-M-24A-01)
Number of
Switch Blocks
Unit position
Non-lightedCode Lighted
NO NC 1 2 3 1 2 3
0 1 --- --- NC --- Lighting unit NC
11 NC NO Lighting unit NC
02
NC --- NC NC Lighting unit NC
01
11
02
12 NCNO NC
03
NC NC NC
12
03
---
NO ---
A22E
3
A22E A22NE-P Common Note
Common Accessories and Tools
Ordering Information
List of Models (Completely Assembled)
Non-lighted Models (Without EMO/EMS Indication)
*Models with Korean S-mark certification
Note: Yellow cap models are also available (not for emergency stop use). Contact your OMRON representative.
Non-lighted Models (With EMO/EMS Indication)
*Models with Korean S-mark certification
Note: The colors of switch blocks are as follows:
NO (a-contact): Black
NC (b-contact): Red
The above illustration shows the 2NC (2b-contact) configuration.
Operation
Set Model Color of cap
Appearance Contact configuration
(Number of switch blocks)
1NC (1) A22E-MP-01
Red
1NC, 1NO (2) A22E-MP-11
2NC (2) A22E-MP-02
1NC (1) A22E-S-01 *
1NC, 1NO (2) A22E-S-11 *
2NC (2) A22E-S-02 *
2NC, 1NO (3) A22E-S-12 *
3NC (3) A22E-S-03 *
1NC (1) A22E-M-01 *
1NC, 1NO (2) A22E-M-11 *
2NC (2) A22E-M-02 *
2NC, 1NO (3) A22E-M-12 *
3NC (3) A22E-M-03 *
1NC (1) A22E-L-01 *
1NC, 1NO (2) A22E-L-11 *
2NC (2) A22E-L-02 *
Operation
Set Model Color of cap
Appearance Contact configuration
(Number of switch blocks)
1NC (1) A22E-M-01-EMO *
Red
A22E-M-01-EMO-RD
1NC, 1NO (2) A22E-M-11-EMO *
A22E-M-11-EMO-RD
2NC (2) A22E-M-02-EMO *
A22E-M-02-EMO-RD
2NC, 1NO (3) A22E-M-12-EMO *
A22E-M-12-EMO-RD
3NC (3) A22E-M-03-EMO *
A22E-M-03-EMO-RD
1NC (1) A22E-M-01-EMS *
A22E-M-01-EMS-RD
1NC, 1NO (2) A22E-M-11-EMS *
A22E-M-11-EMS-RD
2NC (2) A22E-M-02-EMS *
A22E-M-02-EMS-RD
2NC, 1NO (3) A22E-M-12-EMS *
A22E-M-12-EMS-RD
3NC (3) A22E-M-03-EMS *
A22E-M-03-EMS-RD
40-dia. head
Medium Pull-reset
A22E-MP
30-dia. head
Small Turn-reset
A22E-S
40-dia. head
Medium Turn-reset
A22E-M
60-dia.
Large Turn-reset
A22E-L
40-dia. head
Medium Turn-reset
With EMO Indication
40-dia. head
Medium Turn-reset
With EMS Indication
A22E
4
A22E A22NE-P Common Note
Common Accessories and Tools
Lighted Models
*Models with Korean S-mark certification
Switch with Integrated Control Box
Note: The A22Z-B101Y Control Box is used.
*Models with Korean S-mark certification
Operation Push-lock turn-reset system
Color of cap
Appearance
Contacts
(Number of
switch blocks)
LED Lamp voltage
Set Model
40-dia. head
Push-lock
Turn-reset
Lighting unit
(Direct lighting)
A22E
1NC (1)
6 VAC/VDC A22EL-M-6A-01 *
Red
12 VAC/VDC A22EL-M-12A-01 *
24 VAC/VDC A22EL-M-24A-01 *
1NC, 1NO (2)
6 VAC/VDC A22EL-M-6A-11 *
12 VAC/VDC A22EL-M-12A-11 *
24 VAC/VDC A22EL-M-24A-11 *
2NC (2)
6 VAC/VDC A22EL-M-6A-02 *
12 VAC/VDC A22EL-M-12A-02 *
24 VAC/VDC A22EL-M-24A-02 *
40-dia. head
Push-lock
Turn-reset
Lighting unit
(Voltage-
reduction lighting)
A22E
1NC (1) 100 VAC A22EL-M-T1-01
200 VAC A22EL-M-T2-01
1NC, 1NO (2) 100 VAC A22EL-M-T1-11
200 VAC A22EL-M-T2-11
2NC (2) 100 VAC A22EL-M-T1-02
200 VAC A22EL-M-T2-02
Appearance Contact configuration (Number of switch blocks) Model
1NC (1) A22E-M-01B *
1NC, 1NO (2) A22E-M-11B *
2NC (2) A22E-M-02B *
A22E
5
A22E A22NE-P Common Note
Common Accessories and Tools
Subassembled.... The Operation Unit, LED Lamp, Mounting Latches, and Switch Blocks can be ordered separately. Use them in
combination for models that are not available as assembled Units. These can also be used as inventory for
maintenance parts.
*Up to three Switch Blocks can be mounted for multiple contacts.
Operation Unit
Mounting Latches
Non-lighted
Switch Blocks *
Lock Plate
Operation Unit
Lighted
LED Lamp
LED
Lock Plate
Switch Blocks + Lighting unit
Screw Terminal BlockScrew Terminal Block
A22E
6
A22E A22NE-P Common Note
Common Accessories and Tools
Operation Unit
Non-lighted
Lighted
LED lamp
Note: For a model with a Lighting unit (Voltage-reduction lighting), use the A22-24AR.
Sealing capability IP65 oil-resistant models
Function Size Small (30 dia.) Medium (40 dia.) Large (60 dia.)
Pull-reset ---
A22E-MP
---
Turn-reset
A22E-S
A22E-M
A22E-L
A22E-M-EMO
A22E-M-EMO-RD
A22E-M-EMS
A22E-M-EMS-RD
Sealing capability IP65
Function Size Medium (40 dia.)
Turn-reset
A22EL-M
Appearance LED light Rated voltage Model
Red Standard
6 VAC/VDC A22-6AR
12 VAC/VDC A22-12AR
24 VAC/VDC A22-24AR
A22E
7
A22E A22NE-P Common Note
Common Accessories and Tools
Switch
Non-lighted / Direct lighting
Voltage-reduction lighting (100 VAC, 200 VAC)
Note: For a model with a Lighting unit (Voltage-reduction lighting), use the A22-24AR.
Classification
Appearance
Non-lighted Direct lighting
Contact specifications/
Configuration (Number of switch blocks) Model Model
For Standard
loads
1NC (1) A22-01M A22L-01M
1NC, 1NO (2) A22-11M A22L-11M
2NC (2) A22-02M A22L-02M
Classification
Appearance
100 VAC, Lighted 200 VAC, Lighted
Contact specifications/
Configuration (Number of switch blocks) Model Model
For Standard
loads
1NC (1) A22L-01M-T1 A22L-01M-T2
1NC, 1NO (2) A22L-11M-T1 A22L-11M-T2
2NC (2) A22L-02M-T1 A22L-02M-T2
A22E
8
A22E A22NE-P Common Note
Common Accessories and Tools
Accessories (Order Separately)
Note: For details on the accessories common to the screw terminal block types and push-in plus terminal block types, refer to "Common
Accessories and Tools (Order Separately)" on page 32.
Item Appearance Contact specifications Model Remarks
Switch Blocks
(one contact)
1NO (Black)
Standard load
A22-10
Provided as standard.
Order Switch Blocks only when
adding or replacing them.
Microload
A22-10S
1NC (Red)
Standard load
A22-01
Microload
A22-01S
Switch Blocks
(two contacts)
2NO (Black)
Standard load
A22-20
Order Switch Blocks only when
adding or replacing them.
Microload
A22-20S
2NC (Red)
Standard load
A22-02
Microload
A22-02S
1NC + 1NO
Contact (Black/
Red)
Standard load
A22-11
Microload
A22-11S
Lighting unit
Direct lighting A22-TN
Used when changing the lighting
method.
Voltage-reduction
lighting
100 VAC A22-T1
200 VAC A22-T2
Mounting Latches --- A22-3200
Provided as standard.
Order Mounting Latches only when
mounting Switch Blocks or Lighting
Units that are purchased
individually.
Lock Plate
--- A22Z-3380 Use to fix the lever on the Switch.
Control Boxes
(Enclosures) One hole, yellow box
A22Z-B101Y
Material: Polycarbonate resin.
The A22Z-B101Y does not support
2NO, 2NC, or 1NC + 1NO two-
contacts Switch Blocks.
A22Z-B201Y
A22E
9
A22E A22NE-P Common Note
Common Accessories and Tools
Specifications
Certified Standard Ratings
UL, cUL (File No. E41515)
6 A at 220 VAC, 10 A at 110 VAC
TÜV (EN60947-5-1) (Low Voltage Directive)
3 A at 220 VAC
CCC (GB14048.5)
3 A at 240 VAC, 1.5 A at 24 VDC
Certified Standards
Note:
Only models with NC contacts have a direct opening mechanism.
*1. UL-certification for CSA C22.2 No. 14 has been obtained.
Certification has been obtained for individual Switch Blocks and
Lighting Units.
*2. Some models have been certified.
Ratings
Contacts (Standard Load)
Note: 1. Rated current values are determined according to the
testing conditions. The above ratings were obtained by
conducting tests under the following conditions.
(1) Ambient temperature: 20°±2°C
(2) Ambient humidity: 65±5%
(3) Operating frequency: 20 operations/minute
2. Minimum applicable load: 10 mA at 5 VDC
LED Lamp
Voltage-reduction lighting
Characteristics
*1. With no icing or condensation.
*2. The degree of protection from the front of the panel.
*3. The degree of protection is IP65 even with an integrated control box, but the system is not oil resistant.
Certification
body Standards File No.
UL *1
UL508, C22.2 No.14
E41515
TÜV SÜD
EN60947-5-1
(Certified direct opening),
EN60947-5-5
Consult your OMRON
representative for details.
CQC (CCC) GB14048.5 2003010303070635
KOSHA *2 EN60947-5-1 Consult your OMRON
representative for details.
Rated carry
current (A)
Rated
voltage
(V)
Rated current (A)
AC15
(Inductive
load)
AC12
(Resistive
load)
DC13
(Inductive
load)
DC12
(Resistive
load)
10
24 VAC 10 10
--- ---
110 VAC 5 10
220 VAC 3 6
380 VAC 2 3
440 VAC 1 2
24 VDC
--- ---
1.5 10
110 VDC 0.5
2
220 VDC 0.2
0.6
380 VDC 0.1
0.2
Rated voltage Operating voltage Current value
6 VAC/VDC 6 VAC/VDC ± 5%
Approx. 8 mA12 VAC/VDC 12 VAC/VDC ± 5%
24 VAC/VDC 24 VAC/VDC ± 5%
Rated voltage Operating voltage Rated current Applicable lamp
(BA9S/Base: 13)
110 VAC 100 VAC
(95 to 115 V) Approx. 8 mA LED lamp
A22-24A@
220 VAC 200 VAC
(190 to 230 V)
Type Turn-reset Pull-reset
Item Non-lighted model Lighted model Non-lighted model
Allowable operating
frequency
Mechanical 30 operations/minute (One operation consists of set and reset operations.)
Electrical 30 operations/minute (One operation consists of set and reset operations.)
Insulation resistance 100 MΩ min. (at 500 VDC)
Contact resistance 100 mΩ max. (initial value)
Dielectric strength Between terminals of same polarity 2,500 VAC, 50/60 Hz for 1 min.
Between each terminal and ground 2,500 VAC, 50/60 Hz for 1 min.
Vibration resistance 10 to 55 Hz, 1.5-mm double amplitude (contact separation within 1 ms)
Shock resistance Destruction 1000 m/s2
Malfunction 250 m/s2 max. (contact separation within 1 ms)
Durability Mechanical 300,000 operations min. (One operation consists of set and reset operations.)
Electrical 300,000 operations min. (One operation consists of set and reset operations.)
Ambient operating temperature *1-20 to +70°C -20 to +55°C -20 to +70°C
Ambient operating humidity 35 to 85% RH
Ambient storage temperature -40 to +70°C
Degree of protection IP65 (oil-resistant) *2 *3 IP65 *2 IP65 (oil-resistant) *2 *3
Electric shock protection class Class II
PTI (tracking characteristic) 175
Degree of contamination 3 (EN60947-5-1)
Minimum direct opening stroke 11 mm
Minimum direct opening force 45 N
Conditional short-circuit current 100 A (EN 60947-5-1)
Weight (for a 40-dia. head 1NC/1NO Operation Unit) Approx. 65 g Approx. 80 g Approx. 100 g
A22E
10
A22E A22NE-P Common Note
Common Accessories and Tools
Operating Characteristics
*Rotation torque value.
Terminal Arrangement (BOTTOM VIEW)
Terminal connection
Note: The above terminal connection diagrams are examples of the number of contacts.
Terminal wiring drawings of two-contact Switch Units
Item Turn-reset Pull-reset
Total travel force (TTF) 44.1 N max. 58.8 N max.
Return force (RF) 0.25 N·m * max. 58.8 N max.
Total travel (TT) 10 ±1 mm 5.5 ±1 mm
Non-lighted (two contacts) Non-lighted (three contacts) Lighted (two contacts)
Type Terminal Connection (BOTTOM VIEW)
1NC, 1NO (two contacts) 2NC (two contacts) 2NC, 1NO (three contacts) 3NC (three contacts)
Non-lighted
Lighted with
Direct lighting
Lighted with
Voltage-reduction
lighting
16.7
20.7
Switch Blocks
M3.5 screws
OPEN
LOC
10
Switch Blocks
16.7
22
10 Switch Blocks
Lighting unit
3
4
1
2
NC NO
3
4
1
2
1
2
NC NONC
1
2
1
2
1
2
NC NCNC
1
2X2
X1
X
3
4
1
2
1
2
X2
X1
X
X1
X2
1
2
X
3
4
X1
X2
X
1
2
1
2
AB
Type Terminal Connection (BOTTOM VIEW)
2NC (two contacts) 2NO (two contacts)
1NC, 1NO (two contacts)
A
B
21
22
24
23
24
23
12
11
14
13
12
11
A22E
11
A22E A22NE-P Common Note
Common Accessories and Tools
Structure and Nomenclature
Dimensions (Unit: mm)
Non-lighted Models
Note: Unless otherwise specified, a tolerance of ±0.8mm applies to all dimensions.
A22E-MP A22E-S
A22E-M A22E-L
}
Color: Red
Non-lighted
LED lighting
Light source
LED Lamp
Mounting Latches
Switch Blocks
Lighting unit
Contact Ratings
10 A at 100 VAC (resistive load)
10 A at 24 VDC (resistive load)
Lighting Method
Non-lighted
Lighted (Direct lighting)
Lighted (Voltage-reduction lighting)
Lock Plate (Attached with the Operation Unit)
(Refer to the "Mounting the Lock Plate" on page 15 for use.)
Operation Unit
Lamp
Switch
1.8
5.9
0.5
32 54.7
40 dia. 34
Medium Push-pull (40-dia.)
1.8
5.9
0.5
32 54.7
34
30 dia.
Small Turn-reset (30-dia.)
2
1.5 2
5.9
1.8
0.5
32
54.7
41.2
18.5
6.5
40 dia. 34
Note: The dimensions are the same as for EMO/EMS
indication models.
Medium Turn-reset (40-dia.)
1.8
5.9
0.5
32 54.7
60 dia. 34
Large Turn-reset (60-dia.)
A22E
12
A22E A22NE-P Common Note
Common Accessories and Tools
Note: Unless otherwise specified, a tolerance of ±0.8mm applies to all dimensions.
Accessories (Order Separately)
Control Box
Control Box
Note: For details on the accessories common to the screw terminal block types and push-in plus terminal block types, refer to "Common
Accessories and Tools (Order Separately)" on page 32.
Lighted Model
Switch dimensions when mounted to a 2NO (2NC) one-piece
switch block
A22EL-M
LED Lamp
A22-6@, 12@, 24@
2
1.5 2
5.9
1.8
0.5
32
54.7
41.2
18.5
6.5
40 dia. 34
Medium Turn-reset (40-dia.)
72.7
57.8
4424
Note: The operation unit is an example for the A22E-M.
10.6 dia.
9.5 dia.
20±1.5
BA9S/13
Model indication
6.3
2-R3
4.3
41
16±1 dia.
(Bottom lead
draw-out hole)
32
39
Two, mounting holes
56
4-4×38 tapping screw
22.1±0.3
0.1 dia.
10 (10×36) 0.6 depression
75
20.5±0.1
2.8±0.1
68
36
Two, 21 dia.
(Side lead
draw-out hole)
20
41
69.5
A22Z-B101Y (1-hole) Cable Draw-out Hole
(Top View)
Mounting Hole
Two, 19±1 dia.
(Bottom lead draw-out hole)
40
Two, mounting holes
54
Four, M4 Screws
22.1±0.3
0.1 dia.
10 (10×36) 0.6 depression
68
2.8±0.1
68
36
20.5±0.1
Two, 21 dia.
(Side lead
draw-out hole)
30.5
60
16
6.3
2-R3
4.3
A22Z-B201Y (1-hole) Cable Draw-out Hole
(Top View)
Mounting Hole
A22E
13
A22E A22NE-P Common Note
Common Accessories and Tools
Installation
Mounting to the Panel
Assembling the Cap
(1) Preparing the Panel (2) Mounting the Operation Unit on the Panel
The panel dimensions are shown below.
The panel thickness must be 1 to 5 mm.
Always use a 25-mm-dia. A22Z-R25 Lock Ring for a 25-mm-dia. hole.
IP65 degree of protection will be lost if the 25-mm-dia. Lock Ring is not used
because of the larger size of a 25-mm-dia. hole.
When painting or coating the panel, make sure that the specified panel
dimensions apply to the panel after painting or coating.
Insert the Operation Unit from the front surface of the panel, insert the Lock
Ring and the mounting Ring from the terminal side, then tighten the Ring.
Before tightening, check that the rubber washer is present between the
Operation Unit and the panel.
Align the Lock Ring with the groove in the casing, then insert the Lock Ring so
that its edge is located on the panel side.
Tighten the mounting nut at a torque of 0.98 to 1.96 N·m.
When using a Lock Ring, replace with the supplied Lock Ring, insert the
projecting part into the lock slot, and then tighten the mounting Ring.
(3) Mounting the Switch on the Operation Unit
Insert the Operation Unit into the Switch Unit, aligning the arrow mark inscribed
on the Case with the lever on the Switch Blocks, then move the lever in the
direction indicated by the arrow in the following figure.
(4) Removing the Switch
Emergency Stop Switch
Insert the protrusion of the Tightening Wrench (A22Z-3905) into the Cap slot and then turn to remove the Cap.
22.3 dia.
+0.4
0 25 dia.
+0.5
0
22.3 dia.
+0.4
0
24.1+0.4
0
3.2
R0.8 max.
With Lock Ring Without Lock Ring
+0.2
0
Hold here
Mounting Ring
Lock Ring
Rubber Washer Panel
Panel
Lock Ring
Projecting
part
1. When the panel cutout dimension is
25 dia., remove the supplied rubber
washer and mount the 25-dia. Ring as
shown below. (Since the A22Z-R25 is
not attached to the main body, order
separately.) When using a Legend
Plate (Order Separately), do not
remove the rubber washer.
22 dia.
22.3 dia.
25 dia.
25 dia.
22.3 dia.
0.5 1.3
Panel
Lock Ring
Mounting Ring
25-dia. Ring
(A22Z-R25)
Operation Unit
Rubber washer
(mounted to
Operation Unit)
When not using a
Legend Plate,
remove the rubber
washer.
(If required)
Legend Plates for
Emergency Stop
(order separately)
2. When the panel cutout
dimension is 30 dia., use resin
attachment A22Z-A30. Since it
is not attached to the main
body, order separately.
Operation Unit
Rubber washer
(mounted to
Operation Unit)
30-dia.
Resin Attachment
(A22Z-A30)
Rubber washer
(included)
Mounting
panel
Lock Ring
Mounting
Ring
Lever
Arrow mark
Operation
Unit
Move the lever in the direction indicated by the arrow in the following figure,
then pull the Operation Unit or the Switch Blocks.
Since the lever has a hole with an inside diameter of 6.5 mm, the lever can
be moved in the specified direction by inserting a screwdriver into the hole
and then moving the screwdriver.
Screwdriver
Cap slot Protrusion
A22E
14
A22E A22NE-P Common Note
Common Accessories and Tools
Installing/Replacing the LED Lamp
Control Box (Enclosure)
Installing/Removing the Switch Blocks Wiring
Installing/Replacing on the Switch
Grip the lamp with your fingers, then rotate the lamp while pressing it against the Switch.
(1) Mounting the Switch (2) Creating a Cable Port Hole (3) Securing the Connector Cable
The Standard-size Legend Plate Frame can
be mounted.
Mount the Frame as shown in the following
diagram. Mount the Switch in the same way
as for an ordinary panel.
Place the tip of a screwdriver on the surface
where the cable port hole is to be created
with the cover attached and strike the
screwdriver to punch a hole.
Attempts to punch a hole on the other side
of the case will damage the Box.
1. Insert the connector into the cable port hole in the Box and secure
with the Mounting Ring inside the box.
2. Pass the tightening cap through the cable, insert the cable into the
connector, and tighten the tightening cap to secure the cable.
(1) Installing the Switch Blocks (2) Removing the Switch Blocks Wiring Round Crimp Terminals
Hook the small protrusion on the Mounting Latch
into the groove on the other side of the lever, then
push up the Switch Block in the direction indicated
by the arrow in the figure below.
Insert a screwdriver between the Mounting Latch
and the Switch Block, then push down the screw-
driver in the direction indicated by the arrow in the
following figure.
Loosen the terminal screw from the Switch
Unit until it completely comes off the groove,
insert a screwdriver as shown in the following
figure, then push up the washer in the direc-
tion indicated by the arrow to temporarily
secure it.
Now, a round crimp terminal can be con-
nected. After inserting the terminal, tighten the
screws to complete wiring.
Snap-in Legend Plate
Mounting
RIng
Rubber washer
Connector
Outside Inside
Box
Cable
Tightening cap
Cable diameter (mm)
Connector
7 to 9 dia. A22Z-3500-1
9 to 11 dia. A22Z-3500-2
Switch Blocks
Mounting Latches
Lever
Protrusion
Screwdriver
Use either of the following screwdrivers.
Flat-head screwdriver 3 to 6 mm
3 to 6 mm dia.
Phillips screwdriver
Screwdriver
Washer
Screw
A22E
15
A22E A22NE-P Common Note
Common Accessories and Tools
Safety Precautions
Be sure to read the precautions for All PushButton Switches in the website at:http://www.ia.omron.com/.
Indication and Meaning for Safe Use
If the Operation Unit is separated from the Socket Unit, the
equipment will not stop, creating a hazardous condition.
Secure the lever on the Socket Unit by using the
A22Z-3380 Lock Plate so that the Operation Unit cannot be
easily separated from the Socket Unit.
(Refer to “Mounting the Lock Plate” at the below.)
Mounting the Lock Plate
1. Confirm that the lever on the Mounting Latch is on the side where
the Operation Unit is secured and then insert the protrusion on the
Lock Plate into the hole in the lever on the Mounting Latch.
2. Press the hole on the Lock Plate onto the protrusion on the
Mounting Latch until it clicks into place.
Wiring
Terminal screws must be Phillips or slotted M3.5 screws with a
square washer.
The tightening torque is 1.08 to 1.27 N·m.
Single wires, stranded wires, and crimp terminals can be
connected to the Switch.
Applicable Wiring Materials:
Twisted strands: 2 mm2 max.
Solid wire: 1.6 mm dia. max.
After wiring the Switch, maintain an appropriate clearance and
creepage distance.
LED Lamps
The LED current-limiting resistor is built-in, so internal resistance
is not required.
If commercially available LEDs are used, select the ones that meet
the following conditions:
Base: BA9S/13
Overall length: 26 mm max.
Power consumption: 2.6 W max.
When DC-specific LEDs are used, wire the Switch so that the X1
terminal is positive.
Mis-lighting of the LED
The LED lights with approx. 0.1 mA or less of micro-current. Take
a countermeasure like adding a resistor to prevent mis-lighting in
parallel to the LED.
The micro-current varies with the machine (leak current or stray
capacity between cables, etc.). Select resistance value and
allowable power consumption that meet the actual current.
Do not use a lamp that does not satisfy the rating.
Using the Microload
Contact failure may occur if a Switch designed for a standard load is
used to switch a microload. Use Switches within the application
ranges shown in the following graph. Even within the application
range, insert a contact protection circuit, if necessary, to prevent the
reduction of life expectancy due to extreme wear on the
contacts caused by loads where inrush current occurs when the
contact is opened and closed.
The minimum applicable load is the N-level reference value. This
value indicates the malfunction reference level for the reliability
level of 60% (λ 60) (conforming to JIS C5003).
The equation, λ 60 = 0.5 x 106/time indicates that the estimated
malfunction rate is less than 1/2,000,000 with a reliability level of 60%.
Be sure to read the "Safety Precautions" on page 37.
Indicates a potentially hazardous situation
which, if not avoided, may result in minor
or moderate injury or in property damage.
Precautions
for Safe Use
Supplementary comments on what to do
or avoid doing, to use the product safely.
Caution
Precautions for Correct Use
CAUTION
Lever
Operation
Unit
Mounting Latch
Lock Plate
1
2
Naked Crimp Terminals
8 mm max.
16.0 mm max.
8 mm dia. max.
16.0 mm max.
Crimp Terminals with
Insulating Sheaths
20.2 mm max.
8 mm max.
20.2 mm max.
8 mm dia. max.
X1
X2
LED
lamp
R:10kΩ (1W)
Bleeder resistor
(Circuit example)
In case of using 24 VAC/VDC, Direct lighting
Invalid
area
0.1 1 10 100 1,000
10 mA
1 mA
5
12
24
30
0.16 mA 1.6 mA 100 mA
0
Voltage (V)
Microload area
Area of
use
Standard
load area
Current (mA)
16
A22E A22NE-P
Common Accessories and Tools
Common Note
Emergency Stop Pushbutton Switches (22-dia. or 25-dia.) with Push-In Plus technology
A22NE-P
Install in 22-dia. or 25-dia. Panel Cutout
(When Using a Ring)
The small size of the control panel is realized by conserving space
and changing the direction of the wiring.
Since there is no looseness in the wiring, there is a reduction in
the maintenance efforts.
A lock lever mechanism that can be easily operated is adopted.
A maximum of up to six contact points can be combined together
in the contact-point configuration.
Oil-resistant to IP65 (non-lighted models) / IP65 (lighted models).
Model Number Structure
Model Number Legend (Completely Assembled)........Shipped as a set which includes the Operation Unit, LED
Lamp (lighted model only), Mounting Latches, Lighting
Units (lighted model only), and Switch Block.
Be sure to read the "Safety Precautions" on pages 28 and 37.
For the most recent information on models that have been
certified for safety standards, refer to your OMRON website.
2. Reset function
4. Contacts
5. LED lamp voltage
1. Operation Unit size (diameter)
Code Description
None Turn-reset
PPull-reset *
Code
Description
LED Lamp Voltage
Lighted
(LED) *
NNon-lighted ---
A
B
* Lighting color is red.
* The pull-reset type is only available on the 40 dia.
Operation Unit, non-lighted type.
Not available on lighted types.
A22NE- ---
65421
6. Others
Code Configuration
None Standard
B *Built-in control box
* One-contact unit type.
3. Contact specification/Terminal specification
Code Description
PStandard load/Push-in plus terminal block
Code Description
S30 dia.
M40 dia.
L60 dia.
C
D
E
6 VAC/DC
12 VAC/DC
24 VAC/DC
200/220/230/240 VAC
100/110/120 VAC
3
Note 1. NO: 1a-contact NC: 1b-contact
2. For details on the unit position, refer to the figure below.
Code
Number of
Switch Blocks
Unit position
Non-lighted Lighted
NO NC 1 2 3 1 2 3
002 0 1 --- --- NC --- Lighting unit NC
102 1 1 NC NO Lighting unit NC
202 0 2 NC --- NC NC Lighting unit NC
212 1 2 NC NO NC
222 0 3NC NC NC
---
NO ---
(Example: A22NE-M-P102-N)
A22NE-P
17
A22E A22NE-P Common Note
Common Accessories and Tools
Ordering Information
Non-lighted Models
Lighted Model
Switch with Integrated Control Box
Operation
Set Model Color of cap
Appearance Contact configuration
(Number of switch blocks)
1NC (1) A22NE-MP-P002-N
Red
1NC, 1NO (2) A22NE-MP-P102-N
2NC (2) A22NE-MP-P202-N
2NC, 1N
O
(3)
A22NE-MP-P212-N
3NC (3) A22NE-MP-P222-N
1NC (1) A22NE-S-P002-N
1NC, 1NO (2) A22NE-S-P102-N
2NC (2) A22NE-S-P202-N
2NC, 1N
O
(3)
A22NE-S-P212-N
3NC (3) A22NE-S-P222-N
1NC (1) A22NE-M-P002-N
1NC, 1NO (2) A22NE-M-P102-N
2NC (2) A22NE-M-P202-N
2NC, 1N
O
(3)
A22NE-M-P212-N
3NC (3) A22NE-M-P222-N
1NC (1) A22NE-L-P002-N
1NC, 1NO (2) A22NE-L-P102-N
2NC (2) A22NE-L-P202-N
2NC, 1N
O
(3)
A22NE-L-P212-N
3NC (3) A22NE-L-P222-N
Operation
Set Model Color of cap
Appearance Contacts
(Number of switch blocks) LED lamp voltage
1NC (1)
6 VAC/VDC
A22NE-M-P002-A
Red
1NC, 1NO (2) A22NE-M-P102-A
2NC (2) A22NE-M-P202-A
1NC (1)
12 VAC/VDC
A22NE-M-P002-B
1NC, 1NO (2) A22NE-M-P102-B
2NC (2) A22NE-M-P202-B
1NC (1)
24 VAC/VDC
A22NE-M-P002-C
1NC, 1NO (2) A22NE-M-P102-C
2NC (2) A22NE-M-P202-C
1NC (1)
100, 110, 120 VAC
A22NE-M-P002-D
1NC, 1NO (2) A22NE-M-P102-D
2NC (2) A22NE-M-P202-D
1NC (1)
220, 230, 240 VAC
A22NE-M-P002-E
1NC, 1NO (2) A22NE-M-P102-E
2NC (2) A22NE-M-P202-E
Appearance Contact configuration
(Number of switch blocks) Model
1NC (1) A22NE-M-P002-N-B
1NC, 1NO (2) A22NE-M-P102-N-B
2NC (2) A22NE-M-P202-N-B
40-dia. head
Medium Pull-reset
A22NE-MP-P@@2-N
30-dia. head
Small Turn-reset
A22NE-S-P@@2-N
40-dia. head
Medium Turn-reset
A22NE-M-P@@2-N
60-dia.
Large Turn-reset
A22NE-L-P@@2-N
40-dia. head
Medium Turn-reset
A22NE-M-P@@2-A
40-dia. head
Medium Turn-reset
A22NE-M-P@@2-B
40-dia. head
Medium Turn-reset
A22NE-M-P@@2-C
40-dia. head
Medium Turn-reset
A22NE-M-P@@2-D
40-dia. head
Medium Turn-reset
A22NE-M-P@@2-E
A22NE-P
18
A22E A22NE-P
Common Accessories and Tools
Common Note
Subassembled........The Operation Unit, LED Lamp, Mounting Latches, Switch Blocks, and Lighting Unit can be ordered separately. Use
them in combination for models that are not available as assembled Units. These can also be used as inventory for
maintenance parts.
*Up to three Switch Blocks can be mounted for multiple contacts.
Operation Unit Operation Unit
Non-lighted Lighted
Switch Blocks *
LED Lamp
Mounting Latches
Push-in Plus Terminal Block Push-in Plus Terminal Block
Switch Blocks + Lighting Unit
A22NE-P
19
A22E A22NE-P Common Note
Common Accessories and Tools
Operation Unit
Non-lighted
Lighted
LED lamp
Sealing capability IP65 oil-resistant models
Function Size Small (30 dia.) Medium (40 dia.) Large (60-dia.)
Pull-reset ---
A22NE-MP-N
---
Turn-reset
A22NE-S-N
A22NE-M-N
A22NE-L-N
A22NE-MRO-N
A22NE-MRO-N-RD
A22NE-MRS-N
A22NE-MRS-N-RD
Sealing capability IP65
Function Size Medium (40 dia.)
Turn-reset
A22NE-M-L
Appearance LED light Rated voltage Model Remarks
Red
6 VAC/VDC A22NZ-L-RA These LED lamps are for
exclusive use with the A22N
and the A22NE-P. These are
provided with the completely
assembled set of lighted
models. Order LED lamps only
when replacing them.
12 VAC/VDC A22NZ-L-RB
24 VAC/VDC A22NZ-L-RC
100, 110, 120 VAC A22NZ-L-RD
200, 220, 230, 240 VAC A22NZ-L-RE
A22NE-P
20
A22E A22NE-P
Common Accessories and Tools
Common Note
Accessories (Order Separately)
Note: For details on the accessories common to the screw terminal block types and push-in plus terminal block types, refer to "Common
Accessories and Tools (Order Separately)" on page 32.
*The A22NZ-A-B01Y Control Box cannot be used in combination with the A22Z-3476-1 90-dia. Legend Plates for Emergency Stop or the A22Z-
EG@ E-stop Shrouds.
Item Appearance Contact specifications Model Remarks
Switch Blocks
(one contact)
1NO (Blue) Standard load A22NZ-S-P1AN Provided as standard.
Order Switch Blocks only when
adding or replacing them.
1NC (Red) Standard load A22NZ-S-P1BN
Switch Blocks
(two contacts)
2NC (Red) Standard load A22NZ-S-P2BN
Order Switch Blocks only when
adding or replacing them.
1NO/1NC
(White) Standard load A22NZ-S-P2CN
Lighting unit
6 VAC/VDC A22NZ-T-APN
These are provided with the
completely assembled set of
lighted models. Order Lighting
Units only when replacing them.
12 VAC/VDC A22NZ-T-BPN
24 VAC/VDC A22NZ-T-CPN
100, 110, 120 VAC A22NZ-T-DPN
200, 220, 230, 240 VAC A22NZ-T-EPN
Mounting
Latches --- A22NZ-H-02
This Mounting Latch is for
exclusive use with the A22NE-P.
It is provided with the completely
assembled set.
Order Mounting Latches only
when mounting Switch Blocks or
Lighting Units that are
purchased individually.
Control Boxes
(Enclosures) One hole, yellow box A22NZ-A-B01Y
Material: Polycarbonate resin.
Can be used only with a one-
contact Switch Block.
*
A22NE-P
21
A22E A22NE-P Common Note
Common Accessories and Tools
Specifications
Certified Standard Ratings
UL508 (File No. E76675), CSA C22.2 No.14
6 A at 240 VAC, 10 A at 120 VAC
TÜV (EN60947-5-1) - Certified direct opening -
(EN60947-5-5)
AC-15 3 A at 240 VAC
DC-13 4 A at 24 VDC
CCC (GB14048.5)
AC-15 3 A at 240 VAC
DC-13 4 A at 24 VDC
Applicable Standards
UL1059, UL486E (Push-in Plus Terminal Block Types)
Note: Use a 10 A fuse type gI or gG that conforms to IEC60269 as a
short-circuit protection device. This fuse is not provided in the
main unit.
Certified Standards
Note: Only models with NC contacts have a direct opening
mechanism.
*UL-certification for CSA C22.2 No. 14 has been obtained.
Ratings
Contacts (Standard Load)
Note: 1. The above ratings were obtained by conducting tests under
the following conditions.
(1) Ambient temperature: 20°±2°C
(2) Ambient humidity: 65±5%
(3) Operating frequency: 30 operations/minute
2. Minimum applicable load: 10 mA at 5 VDC (Resistive load)
The operating range may vary depending on the usage
conditions and type of load.
LED Lamp
Certification
body Standards File No.
UL *
UL508, C22.2 No.14
E76675
TÜV SÜD
EN60947-5-1
(Certified direct opening),
EN60947-5-5
Consult your OMRON
representative for details.
CQC (CCC) GB14048.5 2017010305959182
Rated
insulation
voltage (V)
Rated carry
current (A)
Rated
voltage
(V)
Rated current (A)
AC15
(Inductive
load)
AC12
(Resistive
load)
DC13
(Inductive
load)
DC12
(Resistive
load)
600 10
24 VAC 10 10
--- ---
120 VAC 6 10
240 VAC 3 6
380 VAC 1.9 2
440 VAC 1.6 2
24 VDC
--- ---
48
120 VDC 1.1
2.2
240 VDC 0.55
1.1
Rated voltage Operating voltage Current value
6 VAC/VDC 6 VAC/VDC ± 10% Approx. 11 mA
12 VAC/VDC 12 VAC/VDC ± 10% Approx. 12 mA
24 VAC/VDC 24 VAC/VDC ± 10% Approx. 12 mA
100 VAC 100 VAC ± 10%
Approx. 12 mA110 VAC 110 VAC ± 10%
120 VAC 100 VAC to 130 VAC
200 VAC 200 VAC ± 10%
Approx. 12 mA
220 VAC 220 VAC ± 10%
230 VAC 230 VAC ± 10%
240 VAC 220 VAC to 250 VAC
A22NE-P
22
A22E A22NE-P
Common Accessories and Tools
Common Note
Characteristics
*1. State when an LED is not added between terminals of the same polarity on a lighting unit. Does not apply to lighted-type 100 to 200 V lighting
units.
*2. With no icing or condensation.
*3. The degree of protection from the front of the panel.
*4. The degree of protection is IP65 even with an integrated control box, but the system is not oil resistant.
Operating Characteristics
*Rotation torque value.
Terminal Arrangement (BOTTOM VIEW)
Type Turn-reset Pull-reset
Item Non-lighted model Lighted Model Non-lighted model
Allowable operating
frequency
Mechanical 30 operations/minute or less (One operation consists of set and reset operations.)
Electrical 30 operations/minute or less (One operation consists of set and reset operations.)
Insulation resistance *1100 MΩ min. (at 500 VDC)
Contact resistance 100 mΩ max. (initial value)
Dielectric strength
Between terminals of
same polarity *12,500 VAC, 50/60 Hz 1 minute (initial value)
Between each terminal
and ground 2,500 VAC, 50/60 Hz 1 minute (initial value)
Vibration resistance Malfunction 10 to 55 Hz, 1.5 mm double amplitude (contact separation within 1 ms)
Shock resistance Malfunction 250 m/s2 max. (contact separation within 1 ms)
Durability Mechanical 300,000 operations min. (One operation consists of set and reset operations.)
Electrical 300,000 operations min. (One operation consists of set and reset operations.)
Ambient operating temperature *2-20 to +70°C -20 to +55°C -20 to +70°C
Ambient operating humidity 35 to 85% RH
Ambient storage temperature *2-40 to +70°C
Degree of protection*3IP65 (oil-resistant) *4 IP65 IP65 (oil-resistant) *4
Electric shock protection class Class II
PTI (tracking characteristic) 175
Degree of contamination 3 (EN 60947-5-1)
Minimum direct opening stroke 11 mm
Minimum direct opening force 45 N
Conditional short-circuit current 100 A (EN 60947-5-1)
Wight
(for a 40-dia. head 1NC/1NO Operation Unit) Approx. 55g Approx. 60g Approx. 85 g
Item Turn-reset Pull-reset
Total travel force (TTF) 45 N max. 60 N max.
Return force (RF) 0.25N·m * max. 60 N max.
Total travel (TT) 10 ±1 mm 5.5 ±1 mm
Non-lighted (two contacts) Non-lighted (three contacts) Lighted (two contacts)
Terminal
(insertion) hole
Lock lever
(17.6°)
(20°)
10
20
31.9
4
Switch Blocks
Lock lever
Terminal
(insertion) hole
(17.6°)
(20°)
10
20
31.9
4
Switch Blocks
Lock lever
Lighting unit
Terminal
(insertion) hole
(17.6°)
(20°)
10
20
31.9
4
Switch Blocks
A22NE-P
23
A22E A22NE-P Common Note
Common Accessories and Tools
Terminal connection
Note: The above terminal connection diagrams are examples for 1NO, 1NC (two contacts), or 2NC (two contacts).
Terminal wiring drawings of two-contact Switch Units
Structure and Nomenclature
Type Terminal Connection (BOTTOM VIEW)
1NC, 1NO (two contacts) 2NC (two contacts) 2NC, 1NO (three contacts) 3NC (three contacts)
Non-lighted
Lighted
3
4
1
2
NC NO
3
4
1
2
1
2
NC NONC
1
2
1
2
1
2
NC NCNC
1
2X2
X1
X
3
4
1
2
1
2
X2
X1
X
B
A
Type Terminal Connection (BOTTOM VIEW)
2NC (two contacts) 1NC, 1NO (two contacts)
A
B
22
21
22
21
11
12
14
13
}
Color: Red
Non-lighted
LED lighting
Light source
LED Lamp
Mounting Latches
Switch Blocks
Lighting unit
Contact Ratings
6 A at 240 VAC
10 A at 120 VAC
Lighting Method
Non-lighted
Lighted (LED)
Operation Unit
Lamp
Switch
A22NE-P
24
A22E A22NE-P
Common Accessories and Tools
Common Note
Dimensions (Unit: mm)
Non-lighted Models
Note: Unless otherwise specified, a tolerance of ±0.8mm applies to all dimensions.
Dimensions when a two-contact Switch Block is attached
A22NE-MP-P@@2-N A22NE-S-P@@2-N
A22NE-M-P@@2-N A22NE-L-P@@2-N
Lighted Model
A22NE-M-P@@2-@
1.8
5.9
0.5
32 39.5
40 dia. 42.5
Pull-reset (40-dia.)
1.8
5.9
0.5
32 39.5
30 dia. 42.5
Small Turn-reset (30-dia.)
1.8
5.9
0.5
32 39.5
40 dia. 42.5
Note: The dimensions the same even if the Operation Unit is replaced
with the A22NE-MR@-N or the A22NE-MR@-N-RD.
Medium Turn-reset (40-dia.)
60 dia.
1.8
5.9
0.5
32 39.5
42.5
Large Turn-reset (60-dia.)
40 dia.
1.8
5.9
0.5
32 39.5
42.5
Medium Turn-reset (40-dia.)
40 dia.
0.5
1.8
5.9
55
44
32
A22NE-P
25
A22E A22NE-P Common Note
Common Accessories and Tools
Accessories (Order Separately)
Switch Block with Push-In Plus technology
Note: For details on the accessories common to the screw terminal block types and push-in plus terminal block types, refer to "Common
Accessories and Tools (Order Separately)" on page 32.
47.6
23.8
16.4
5
9.9
4
Switch Block (one contact)
A22NZ-S-P1@N
47.6
39.3
31.9
5
9.9
4
Switch Block (two contacts)
A22NZ-S-P2@N
47.6
26.4
23.8
16.4
12 dia.
9.9
Lighting unit
A22NZ-T-@PN
51.3
17.1
R29.5
30
Mounting Latches
A22NZ-H-02
24.3
9.8 dia.
9 dia.
LED Lamp
A22NZ-L-@@
80
80
22.3 dia.
3.2
3.2
24.2
24.2
Four, M4 Phillips
binding screws
18.5
38
59.9
Two, 21.4 dia.
(Side lead hole)
Cover (Yellow) Case (Black)
Two, 14-dia.
(Bottom lead hole)
40
10
10
62
40
Four, 3.7-dia.
(M4-tapped holes)
Two, 4.4-dia.
(oval mounting hole)
5.4
Control Box
A22NZ-A-B01Y
A22NE-P
26
A22E A22NE-P
Common Accessories and Tools
Common Note
Application
Mounting to the Panel
(1) Preparing the Panel (3) Mounting the Operation Unit on the Panel
Panel hole dimension and panel thickness
If outer surface treatment such as coating is performed for the panel, the panel
dimensions after outer surface treatment must meet the specified panel
dimensions.
When using a A22Z-3360 (Order Separately) Lock Ring
For 25-dia.
Use the A22Z-R25 (Order Separately) rubber ring.
Do not tighten the Mounting Nut more than necessary using tools such as
pointed-nose pliers.
Doing so will damage the Mounting Nut.
(The tightening torque of the Mounting Nut is 1.0 to 2.0 N·m.)
Tightening Wrench: A22Z-3905
Panel Hole of 22.3-mm Diameter
Insert the Operation Unit from the front of the panel, insert the Lock Ring and
Mounting Nut from the back of the panel, and tighten the Mounting Nut. Before
tightening, check that the rubber washer is present between the Operation Unit
and the panel.
(2) Minimum mounting pitch (Dimension A, Dimension B)
Minimum mounting pitch
*1. If the Mounting Collar lock levers all face the same direction at the
minimum mounting pitch, be sure to note the order the mounting
collars are attached to the Operation Unit.
*2. When using each accessory (Order Separately), set the A and B
dimensions in view of the dimensions of the accessories.
*3. Make sure the mounting pitch does not hinder the operation.
Panel hole dimension Panel thickness
22.3 dia. 1 to 5 mm
22.3 dia.
+0.4
0
22.3 dia.+0.4
0
R0.8 max.
+0.2
0
3.2
24.1+0.4
0
25 dia.
+0.5
0
Rubber Washer
22.3 dia.
Lock Ring
Mounting Ring
Panel
Tightening Wrench
(order separately, A22Z-3905)
Lock Ring
Panel
Rubber washer
Mounting Ring
Hold here
When the A22Z-3360 Lock Ring (Order Separately) is used
Take note of the direction when mounting the Lock Ring.
Panel
Projecting part
Lock Ring
25-dia. Ring
A22Z-R25
Operation Unit
Panel
Lock Ring
Mounting Ring
22.3 dia.
22.3 dia.
1.30.5
25 dia.
22.3 dia.
22 dia.
Rubber washer
(provided with the
Operation Unit)
Operation Unit
30-dia.
Resin Attachment
A22Z-A30
Rubber Washer
(included)
Mounting Panel
Lock Ring
Mounting Ring
Rubber Washer
(provided with the
Operation Unit)
Panel Hole of 25.5-mm Diameter
Insert the A22Z-R25 (Order
Separately) between the Operation
Unit and Panel, and tighten the
clamping nut to mount.
Before tightening, check that the
rubber washer supplied with the
Operation Unit is present between
the Operation Unit and the 25-dia.
Ring.
Panel Hole of 30-mm Diameter
Insert the A22Z-R30 (Order
Separately) between the Operation
Unit and Panel, and tighten the
clamping nut to mount.
Before tightening, check that the
supplied rubber washer is present
between the Operation Unit and
the panel, and between the 30-dia.
Resin Attachment and the panel.
Recommended panel thickness: 1
to 3 mm
Type of operation unit Dimension A (mm)
min.
Dimension B (mm)
min.
30-dia., 40-dia. models 50 *150
60-dia. model 70 70
Dimension A
R0.8 max.
+0.4
0
+0.4
0
22.3 dia.
24.1+0.4
0
+0.2
0
3.2
Using the
Lock Ring
Standard switch
Panel Hole Dimensions for 22.3 Diameter
Dimension B
+0.4
0
22.3 dia. 22.3 dia.
A22NE-P
27
A22E A22NE-P Common Note
Common Accessories and Tools
Removing the Mounting Latch
Switch Blocks and Lighting Unit
Attaching the LED Lamp to the Lighting Unit
Control Box
When the Mounting Latch is to be Removed
Press the lock lever in from the back side to release the lock, and then hook
the Mounting Collar with a screwdriver, move it in the direction indicated at
(2), and remove it. Turn the lever all of the way until it clicks into place.
(1) Installing the Switch Blocks and Lighting Unit
Catch the projection on the opposite side of the Mounting Collar from the
lever side and press the Switch Block in the direction indicated at (1).
(2) Removing the Switch Blocks and Lighting Units
Insert a screwdriver into the gap between the Mounting Collar and Switch
Block and press it inward in the direction shown at (2).
(1)
(3)
(2)
(1)
(1)
(2)
(3)
When the LED Lamp is to be Installed
Insert the protrusions on the LED Lamp into the guides on the Lighting Unit
and then turn the LED Lamp in direction (2) to lock it in place.
(1) Mounting the Switch
Mount the Switch in the same way as for a standard panel.
The tightening torque of the Box screws is 1.4 to 2.0 N·m.
(2) Creating a Cable Hole
To open a cable hole, leave the cover attached, place the tip of a
screwdriver in the grooves at four locations around the cable hole, and strike
the screwdriver with a hammer to open the hole.
(3) Securing the Connector Cable
1. Insert the connector into the cable port hole in the Box and
secure with the fixing nut inside the box.
2. Open a hole in the thin rubber section of the rubber ring.
3. Pass the tightening cap through the cable, insert the cable into
the connector, and tighten the hexagonal nut to secure the cable.
21
Legend Plate
Switch Box
Screwdriver
Groove
Side
Strike at four
diagonally
opposed locations
to open the hole.
Cover
Cable
Hole
Panel
Connector Tightening cap
Cable
Rubber washer
Mounting
RIng
Cable diameter
(mm) Connector
7 to 9 dia. A22Z-3500-1
9 to 11 dia. A22Z-3500-2
A22NE-P
28
A22E A22NE-P
Common Accessories and Tools
Common Note
Safety Precautions
Be sure to read the precautions for All PushButton Switches in the website at: http://www.ia.omron.com/.
Indication and Meaning for Safe Use
If the Operation Unit is separated from the Switch Units, the
equipment will not stop, resulting in a hazardous situation.
Make sure the Operation Unit, Mounting Latches, and the Switch
Units are properly assembled.
<Assembling the Operation Unit and the Mounting Latches>
Align the TOP indication (the mark) on the Operation Unit with
the TOP indication on the Mounting Latches to fit it properly, and
turn the lock lever on the Mounting Latch in the direction shown in
the figure below until a clicking sound is heard.
<Assembling the Mounting Latches and Switch Blocks>
Make sure the hooking part (convex part) on the Mounting Latches
is perfectly latched into the hooking part (concave part) on the
Switch Block.
When transition wiring is performed, make sure the switching
current inside the Switch and the current based on the transition
wiring is below the rated current of the Switch.
If a current value higher than the rated current flows, it could result
in emission of heat, or damage and deformation of the Switch,
which could cause fire and locking of the contact, and thus a loss
of safety.
Do not perform wiring with power supplied to the Switch/Indicator.
Do not touch the terminals or other charged parts while power is
being supplied. Doing so may result in electric shock.
Do not disassemble or modify the Switch/Indicator under any
circumstances.
Doing so may prevent the Switch/Indicator from functioning to its
full capability. Do not drop the Switch/Indicator. Do not apply
pressure that may deform or alter the Switch/Indicator.
The durability of the Switch varies considerably depending on the
switching conditions. Always test the Switch/Indicator under actual
working conditions before application and use the Switch/Indicator
only for the number of switching operations allowed.
Do not allow the load voltage and current to exceed the rated
value. This may damage or burn out the Switch/Indicator.
Do not use the Switch/Indicator in locations where explosive or
flammable gases or liquid may be present or scattered. The
electric ark or the heat caused by switching contacts may cause a
fire or explosion.
Do not use the Switch/Indicator in locations where toxic gases,
such as H2S, SO2, NH3, HNO3, and Cl2, may be present, or in
locations subject to high temperature or humidity. Doing so may
damage the Switch/Indicator due to contact failure or corrosion.
Do not use the Switch/Indicator submersed in oil or water, or in
locations continuously subject to splashes of oil or water. Doing so
may result in oil or water entering and damaging the Switch/
Indicator.
Do not use or keep the Switch/Indicator under the following
conditions:
Subject to severe temperature changes.
Subject to high humidity or condensation.
Subject to severe vibration or shock.
Where direct rays of the sun strike.
Where sea breeze may be present.
Make sure that a rubber washer is present between the Operation
Unit and the panel. Otherwise, the specifications of the protective
structure may not be satisfied.
Do not apply excessive force to the Switch or wirings. Damage or
deformation of the Switch Block could cause an improper contact
or a loss of safety.
Use an appropriate wiring and crimp terminals (hereinafter, called
ferrule terminals).
Exercise caution to avoid wiring errors when connecting the
terminals.
To prevent wiring materials from smoking or ignition, confirm wire
ratings and use the wiring materials given in the following table.
Use wiring crimp terminals and ferrule terminals of the specified
size.
After storing the product for a long time exceeding 1 year, perform,
at a minimum, inspections of the operating characteristics, contact
resistance, insulation resistance, and dielectric strength as well as
evaluate the product under the working conditions.
This Switch/Indicator is intended for indoor use only.
Using the Switch/Indicator outdoors may result in failure.
Precautions
for Safe Use
Comments on what to do or avoid doing, to use
the product safely.
Precautions
for Correct
Use
Supplementary comments on what to do or
avoid doing to use the product safely and
prevent its malfunctioning or an adverse effect
on its performance or functions.
Precautions for Safe Use
1
2
Mounting
Latches
Operation Unit
Lock lever
Mounting
Latches
Switch Blocks
Wire Type Wire
material
Recommended
Wire
Wire coating peeling
amount
Solid wire/
Stranded
Wire
Copper 0.25 to 1.5 mm2
AWG 24 to 16
Ferrules used: 10 to 12 mm
(Varies depending on the
recommended ferrule
conductor length)
Ferrules not used: 8 mm
A22NE-P
29
A22E A22NE-P Common Note
Common Accessories and Tools
Do not wire anything to the release holes.
Do not tilt or twist a flat-blade screwdriver while it is inserted into a
release hole on the terminal block. The terminal block may be
damaged.
Insert a flat-blade screwdriver into the release holes at an angle.
The terminal block may be damaged if you insert the screwdriver
straight in.
Do not allow the flat-blade screwdriver to fall out while it is inserted
into a release hole.
Do not bend a wire past its natural bending radius or pull on it with
excessive force.
Doing so may cause the wire disconnection.
Do not insert more than one wire into each terminal insertion hole.
Do not mount A22N-P or A22NE-P Push-In Plus terminal switch
blocks on A22N screw terminal blocks. Doing so may result in
unsatisfactory performance.
Wiring
1. Connecting Wires to the Push-In Plus Terminal Block
Part Names of the Terminal Block
Connecting Wires with Ferrules and Solid Wires
Insert the solid wire or ferrule straight into the terminal block until
the end strikes the terminal block. The angle should be
approximately 6°.
If a wire is difficult to connect because it is too thin, use a flat-blade
screwdriver in the same way as when connecting stranded wires.
Precautions for Correct Use
Release hole
Terminal (insertion) hole
Terminal (insertion) hole
Ferrule or solid wire
Approx. 6˚
Approx. 6˚
The wiring for the Lighting Unit and Switch Block (2 contacts) are the
same as for the Switch Block (1 contact) shown in the above illustra-
tion.
A22NE-P
30
A22E A22NE-P
Common Accessories and Tools
Common Note
Connecting Stranded Wires
Use the following procedure to connect the wires to the terminal
block.
1. Hold a flat-blade screwdriver at an angle and insert it into the
release hole.
The angle should be approximately 6°. If the flat-blade screwdriver
is inserted correctly, you will feel the spring in the release hole.
2. With the flat-blade screwdriver still inserted into the release hole,
insert the wire into the terminal hole until the end strikes the
terminal block.
3. Remove the flat-blade screwdriver from the release hole.
Checking Connections
After the insertion, pull gently on the wire to make sure that it will
not come off and it is securely fastened to the terminal block.
If you use a ferrule with a conductor length of 10 mm, part of the
conductor may be visible after the ferrule is inserted into the
terminal block, but the product insulation distance will still be
satisfied.
2. Removing Wires from the Push-In Plus Terminal Block
Use the following procedure to remove wires from the terminal block.
The same method is used to remove stranded wires, solid wires, and
ferrules.
1. Hold a flat-blade screwdriver at an angle and insert it into the
release hole. The angle should be approximately 6°.
2. With the flat-blade screwdriver still inserted into the release hole,
remove the wire from the terminal insertion hole.
3. Remove the flat-blade screwdriver from the release hole.
3. Recommended Ferrules and Crimp Tools
Coating peeling amount
Recommended ferrules
Note: 1. Make sure that the outer diameter of the wire coating is
smaller than the inner diameter of the insulation sleeve of
the recommended ferrule.
2. Make sure that the ferrule processing dimensions conform
to the following figures.
Recommended Flat-Blade Screwdrivers
Use a flat-blade screwdriver to connect and remove wires.
Use one of the following flat-blade screwdrivers.
The following table shows manufacturers and models as of 2015/Dec.
*
The SZF 0-0,4 × 2,5 (manufactured by Phoenix Contact) can be
procured through an OMRON exclusive purchase form (XW4Z-00B).
After wiring the Switch/Indicator, provide a sufficient insulation
distance.
Approx. 6˚
(2)
Approx. 6˚
(1)
(3)
Flat-blade screwdriver
Approx. 6˚
The wiring and screwdriver angles for the Lighting Unit and Switch
Block (2 contacts) are the same as for the Switch Block (1 contact)
shown in the above illustration.
Approx. 6˚
(2)
Approx. 6˚
(1)
(3)
Flat-blade screwdriver
Approx. 6˚
The wiring and screwdriver angles for the Lighting Unit and Switch
Block (2 contacts) are the same as for the Switch Block (1 contact)
shown in the above illustration.
Recommend Wire Type Stripping length
(Ferrules not used)
0.25 to 1.5 mm2/AWG 24 to AWG 16 8 mm
Applicable
wire
Ferrule
conductor
length
(mm)
Stripping
length (mm)
(Ferrules not
used)
Recommended ferrules
(mm
2
)
(AWG)
Phoenix
Contact
product
Weidmuller
product
Wago
product
0.25 24 8 10 AI 0, 25-8 H0.25/12 216-301
10 12 AI 0, 25-10 --- ---
0.34 22 8 10 AI 0, 34-8 H0.34/12 216-302
10 12 AI 0, 34-10 --- ---
0.5 20 8 10 AI 0, 5-8 H0.5/14 216-201
10 12 AI 0, 5-10 H0.5/16 216-241
0.75 18 8 10 AI 0, 75-8 H0.75/14 216-202
10 12 AI 0, 75-10 H0.75/16 216-242
1/1.25
18/17
8 10 AI 1-8 H1.0/14 216-203
10 12 AI 1-10 H1.0/16 216-243
1.25/1.5
17/16
8 10 AI 1, 5-8 H1.5/14 216-204
10 12 AI 1, 5-10 H1.5/16 216-244
Recommended Crimp Tools
CRIMPFOX6
CRIMPFOX6T-F
CRIMPFOX10S
PZ6 roto Variocri
mp4
Model Manufacture
ESD 0,40 × 2,5 Wera
SZS 0,4 × 2,5
SZF 0-0,4 × 2,5 *Phoenix Contact
0.4 × 2.5 × 75 302 Wiha
AEF.2,5 × 75 Facom
210-719 Wago
SDI 0,4 × 2,5 × 75 Weidmuller
8 to 10 mm
Max. 1.9 mm Max. 2.6 mm
Side view
0.4 mm
2.5 mm dia.
2.5 mm
Front view
A22NE-P
31
A22E A22NE-P Common Note
Common Accessories and Tools
LED Lamps
A current-limiting resistor is built in the LED lamp, so the
installation of an external resistance is not required.
Lighting malfunction of the LED lamp
A micro-current of approximately 0.1 mA or less is sufficient to turn
on the LED lamps. Take a countermeasure like adding a resistor to
prevent mis-lighting in parallel to the LED lamp.
The micro-current varies with the machine (leak current or stray
capacity between cables, etc.). Select resistance value and
allowable power consumption that meet the actual current.
Be sure to read the "Safety Precautions" on page 37.
X1
X2
LED
lamp
R:10 kΩ (1 W)
Bleeder resistor
(Example of lighting malfunction prevention circuit)
When using a 24-VAC/VDC lighted unit
A22E/A22NE-P
32
A22E A22NE-P Common Note
Common Accessories and Tools
Ordering Information
Common to Screw Terminal Block types (A22E)/Push-in Plus Terminal Block types (A22NE-P)
*1. These Shrouds are for use with the equipment only that conforms to SEMI standards. Do not use them for any other applications (e.g.
emergency stop switches for machines or devices such as Machine tools, Printing presses, Industrial machinery, etc).
*2.
The Control Boxes cannot be used in combination with the A22Z-3476-1 Legend Plates for Emergency Stop or the A22Z-EG
@
E-stop Shrouds.
Note: 1. Accessories for A22Z-EG1: one “EMERGENCY OFF” label, two rubber packings, and one lock ring
2. Accessories for A22Z-EG10: one rubber packing and one lock ring (without label)
Common Accessories and Tools (Order Separately)
Item Appearance Classification Model Remarks
Legend Plates for
Emergency Stop
60-dia. black letters on yellow
back-ground A22Z-3466-1 Used in combination with the washer rubber when the level of
protection is to be met between panels.
90-dia. black letters on yellow
back-ground A22Z-3476-1
60-dia. black letters on yellow
background A22Z-3466-2
Cannot be used in combination with the Control Boxes.
Used in combination with the washer rubber when the level of
protection is to be met between panels.
Hole Plug Round A22Z-3530 Used for covering the panel cutouts for future panel expansion.
Black color.
Connectors Applicable cable
diameter
7 to 9 dia. A22Z-3500-1 Plastic connector used to extend a cable from the Switch Box.
(Refer to page 27).
9 to 11 dia. A22Z-3500-2
25-dia. Ring --- A22Z-R25
Use when mounting to a panel with a 25-dia. hole. (Refer to page
26).
Material: Rubber, Level of protection: IP65
30-dia.
Resin Attachment --- A22Z-A30
Use when mounting to a panel with a 30-dia. hole. (Refer to page
26).
A rubber washer (A22Z-R) is provided with the product.
Lock Ring --- A22Z-3360
The body is equipped with a Lock Ring.
This Lock Ring is used when a more secure lock feature is
required. (Refer to page 26).
Tightening Tool --- A22Z-3905 Used for tightening the mounting ring from the back side of the
panel, and for removing the cap in lighted models.
E-stop Shroud for
EMO, Yellow --- A22Z-EG1
Provides SEMI-S2/SEMATECH APPLICATION GUIDE FOR
SEMI-S2 compatibility. The SEMI-S2-compatible Shroud and
legend plate for EMERGENCY OFF come as a set. Use with an
A22E Emergency Stop Switch (for emergency shutoff) *1 *2
E-stop Shroud for
EMO, Yellow
Legend plate for EMERGENCY
OFF is not included.
A22Z-EG10
Provides SEMI-S2/SEMATECH APPLICATION GUIDE FOR
SEMI S2 compatibility. Use with an A22E with EMO indication.
(for emergency off) *2
E-stop Shroud for
EMS, White --- A22Z-EG1-W
Provides SEMI-S2/SEMATECH APPLICATION GUIDE FOR
SEMI-S2 compatibility. The SEMI-S2-compatible Shroud and
legend plate for EMERGENCY STOP come as a set. Use with
an A22E Emergency Stop Switch. (for emergency stop) *1*2
E-stop Shroud for
EMS, White
Legend plate for EMERGENCY
STOP is not included.
A22Z-EG10-W
Provides SEMI-S2/SEMATECH APPLICATION GUIDE FOR
SEMI S2 compatibility. Use with an A22E with EMS indication.
(for emergency stop) *2
E-stop Shroud,
Yellow
Spacer Unit is not included. A22Z-EG2 SEMI-S2/SEMATECH APPLICATION GUIDE FOR SEMI
S2-compatible Shroud. (for emergency shutoff) *1 *2
Use together with an A22E Emergency Stop Switch.
One Spacer Unit is included. A22Z-EG21
Two Spacer Units are included.
A22Z-EG22
E-stop Shroud for
EMO, Yellow --- A22Z-EG3
Provides SEMI-S2/SEMATECH APPLICATION GUIDE FOR
SEMI-S2 compatibility. The SEMI-S2-compatible Shroud and
legend plate for EMERGENCY OFF come as a set. Use with an
A22E Emergency Stop Switch.(for emergency shutoff) *1 *2
Rubber Packing - A22Z-R Used together with accessories.
Contains 10 packings.
A22E/A22NE-P
33
A22E A22NE-P Common Note
Common Accessories and Tools
Dimensions (Unit: mm)
Screw Terminal Block Type/Push-in Plus Terminal Block Type
30 dia. 1
13
2.5
6
Hole Plug
Round A22Z-3530
6.1
3.8
20.5
2.8
22.2 dia.
34.7 dia.
30-dia. Resin Attachment
A22Z-A30
Legend Plates for Emergency Stop
A22Z-3466-1 (60 dia.)
22.2 dia.
60 dia.
A22Z-3466-2 (60 dia.)
Black letters
Yellow
Black letter
60 dia.
22.2 dia.
t1t1
t1
Yellow
22.2 dia.
90 dia.
A22Z-3476-1 (90 dia.)
Black letters
Yellow
20.5
2
1
2.8
Lock Ring
A22Z-3360
22.2 dia.
30 dia.
Material: Nickel plated on iron
25-dia. Ring
A22Z-R25
22 dia.
24.8 dia.
27 dia.
0.5
1.3
Material: NBR (black)
4.5 20
90 2
Tightening Tool
A22Z-3905
19.2 dia.
21.2 dia.
25 dia.
30 dia.
22 dia.
27 dia.
0.5
Rubber Packing
A22Z-R
A22E/A22NE-P
34
A22E A22NE-P Common Note
Common Accessories and Tools
2.3 +0.5
-1.5
Switch Mounting Dimension
2.3 +0.5
-1.5
Switch Mounting
Dimension
Sunken
section,
0.2 Switch guard
75
2.8
20.5
63
90 dia.
78 dia.
38 52.2 max.
30 40
75 min.
(Determined by the
height of the Switch
surface in the
lock position.)
22.2 dia
33 dia.
Panel Cutout Dimensions
Allowable panel thickness: 1 to 2 mm
5R
EMERGENCY OFF
inscription plate (t=1)
Rubber packing (t=0.5)
Rubber packing (t=0.5)
Locking ring
Mounting panel
21
Panel
Switch Unit
A22E-M
2.5+0.5
-1.5 8
R1.7+0.1
0
22.3+0.4
0 dia.
24.2±0.2
“EMERGENCY STOP” is indicated
on A22Z-EG1-W.
Legend plate is not provided with
A22Z-EG10 and A22Z-EG10-W.
8.5
38 52.2 max.
30 dia.
40 dia.
1-pole
Switch Unit 2-pole
Switch Unit
R5
38.5 37 max.
Panel Panel
Screw Terminal Block type
Mounting a 1-pole Switch Unit
Push-in Plus Terminal Block type
Mounting a 1-pole Switch Unit
Push-in Plus Terminal Block type
Mounting a 2-pole Switch Unit
Note: 1. The dimensions of the
Shroud conform to the
specifications of the
SEMATECH
Application Guide for
SEMI S2-93.
2. The Shroud is not
provided with the
Switch.
Common E-stop Shrouds
A22Z-EG1, A22Z-EG1-W, A22Z-EG10, A22Z-EG10-W
A22E/A22NE-P
35
A22E A22NE-P Common Note
Common Accessories and Tools
12
2R
M90
353
20.6
22.2 dia.
2.8
79 dia.
98 dia.
105 dia.
Detents
inside
(One on
each side)
95 +0.2
0
5.5 +0.2
0
90.3 +0.4
0 dia.
20
23
10
13 Panel Panel
SpacersSpacer
105 max.
1b Contact Unit
Position of
detent
notch
Position of
detent
notch
Panel
The number of spacers depends on the model
A22Z-EG2 : No Spacer
A22Z-EG21 : 1 Spacer
A22Z-EG22 : 2 Spacers
88 max.
Position of
detent
notch
Position of
detent
notch
Panel
Panel
2b One-Piece
Contact Unit
2b One-Piece
Contact Unit
72 max.
With 1 Spacer With 2 Spacers Screw Terminal Block Type
Mounting a 1-pole Switch Unit *
Screw Terminal Block Type
Mounting a 2-pole Switch Unit *
Push-in Plus Terminal Block Type
Mounting a 1-pole Switch Unit *
Push-in Plus Terminal Block Type
Mounting a 2-pole Switch Unit *
Panel Cutout Dimensions
* These are the dimension from the front of the panel when the Switch Unit is attached.
During spacer attachment
E-stop Shrouds
A22Z-EG2, A22Z-EG21, A22Z-EG22
Note: 1. The dimensions of the Shroud conform to the
specifications of the SEMATECH Application Guide
for SEMI S2-93.
2. The Shroud is not provided with the Switch.
3. Tighten to a torque of 1.96 to 2.94 Nm.
4. The allowable panel thicknesses are as follows:
Without Spacers: t=1.3 to 22.5 mm
With 1 Spacer: t=1.3 to 12.5 mm
With 2 Spacers: t=1.3 to 2.5 mm
A22E/A22NE-P
36
A22E A22NE-P Common Note
Common Accessories and Tools
1-pole
Switch Unit
1-pole
Switch Unit
2-pole
Switch Unit
1.7R+0.1
0
2.8
33 dia.
C
C
78 min. (Determined by the
height of the Switch
surface in the lock position.)
20.5
22.2 dia.
E-Stop Shroud
C-C
Panel
Panel
2.5 +0.5
-1.5
Portion B
Legend Plate
(Provided with the Switch Guard)
Rubber Packing
(t=0.5, Rubber Packing)
Panel
Locking Ring
(Rubber Packing)
Mounting Nut
(Provided with the Operation Unit)
Panel Cutout Dimensions
Allowable panel thickness:
1 to 3 mm
22.3 dia.+0.4
0
Rubber Packing
(t=0.5, Rubber Packing)
Portion A:
Indented part
90 dia.
Switch Mounting
Dimension
2.5 +0.5
-1.5
Switch Mounting
Dimension
71.2 max.
C-C
38
Panel
2-pole Switch Unit
2.5 +0.5
-1.5
Switch Mounting
Dimension
2.5 +0.5
-1.5
Switch Mounting
Dimension
Panel
52.2 max.
38.8
52.2 max.
38
37 max.
38.8
Set model number
A22Z-EG3
24.2±0.2
Screw Terminal Block Type
Mounting a 1-pole Switch Unit
Screw Terminal Block Type
Mounting a 2-pole Switch Unit
Push-in Plus Terminal Block Type
Mounting a 1-pole Switch Unit
Push-in Plus Terminal Block Type
Mounting a 2-pole Switch Unit
E-stop Shroud
A22Z-EG3
Note: 1. The dimensions of the Shroud conform to the
specifications of the SEMATECH Application Guide for
SEMI S2-93.
2. The Shroud is not provided with the Switch.
A22E/A22NE-P
37
A22E A22NE-P Common Note
Common Accessories and Tools
Safety Precautions
Be sure to read the precautions for All PushButton Switches in the website at:http://www.ia.omron.com/.
Indication and Meaning for Safe Use
Mounting
Always make sure that the power is turned OFF before wiring the
Switch. Also, do not touch the terminals or other current-carrying
ports while power is being supplied. Electric shock may occur.
Do not tighten the mounting ring more than necessary using tools
such as pointed-nose pliers. Doing so will damage the mounting
ring. The tightening torque is 0.98 to 1.96 N·m.
Recommended panel thickness: 1 to 5 mm.
When mounting the caps after changing the LED or the caps,
tighten the caps at a tightening torque of 0.49 to 0.78 N·m.
Operating Environment
The IP65 model is designed with a protective structure so that it will
not sustain damage if it is subjected to water from any direction to
the front of the panel.
The Switch is intended for indoor use only. Using the Switch
outdoor may cause it to fail.
Others
If the panel is to be coated, make sure that the panel meets the
specified dimensions after coating.
Due to the structure of the Switch, severe shock or vibration may
cause malfunctions or damage to the Switch.
Also, most Switches are made from resin and will be damaged if
they come into contact with sharp objects. Particularly scratches
on the Operation Unit may create visual and operational
obtrusions.
Handle the Switches with care, and do not throw or drop them.
Precautions
for Safe Use
Supplementary comments on what to do
or avoid doing, to use the product safely.
Precautions for Correct Use
Screwdriver
Hammer
Do not allow the
Switch to drop and hit
the floor.
Do not place or drop
heavy objects on the
Switch.
Do not operate the
Switch with hard or
sharp objects.
MEMO
38
Terms and Conditions Agreement
Read and understand this catalog.
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have
any questions or comments.
Warranties.
(a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship
for a period of twelve months from the date of sale by Omron (or such other period expressed in writing
by Omron). Omron disclaims all other warranties, express or implied.
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE
PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL
SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.
Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products
or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at Omron’s election,
to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the
non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price
of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other
claims or expenses regarding the Products unless Omron’s analysis confirms that the Products were properly handled, stored,
installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by
Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or
unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system
assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in
writing, are not to be construed as an amendment or addition to the above warranty.
See http://www.omron.com/global/ or contact your Omron representative for published information.
Limitation on Liability; Etc.
OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,
WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.
Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.
Suitability of Use.
Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the
combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable
third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is
not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system,
or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with
respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE
QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.
Programmable Products.
Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence thereof.
Performance Data.
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining
suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate it
to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.
Change in Specifications.
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice
to change part numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be
assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at any time to
confirm actual specifications of purchased Product.
Errors and Omissions.
Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is
assumed for clerical, typographical or proofreading errors or omissions.
Authorized Distributor:
In the interest of product improvement,
specifications are subject to change without notice.
Cat. No. A263-E1-01
0917(0917)
© OMRON Corporation 2017 All Rights Reserved.
OMRON Corporation Industrial Automation Company
Regional Headquarters
OMRON EUROPE B.V.
Wegalaan 67-69, 2132 JD Hoofddorp
The Netherlands
Tel: (31)2356-81-300/Fax: (31)2356-81-388
Contact: www.ia.omron.com
Kyoto, JAPAN
OMRON ASIA PACIFIC PTE. LTD.
No. 438A Alexandra Road # 05-05/08 (Lobby 2),
Alexandra Technopark,
Singapore 119967
Tel: (65) 6835-3011/Fax: (65) 6835-2711
OMRON (CHINA) CO., LTD.
Room 2211, Bank of China Tower,
200 Yin Cheng Zhong Road,
PuDong New Area, Shanghai, 200120, China
Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200
OMRON SCIENTIFIC TECHNOLOGIES INC.
6550 Dumbarton Circle Fremont
CA 94555 U.S.A.
Tel: (1) 510-608-3400/Fax: (1) 510-744-1442
CSM_19_2_1017