LZSA Series Single Output Industrial Power Supplies Features 5 Year Warranty -40C to +71C Operation MIL-STD-810E Vibration / Shock Input transient protected UL508, SEMIF47, Factory Mutual (Class 1, Division 2) Rugged mechanical design with coating on pcbs Superior thermal design Wide range adjustment of output Key Market Segments & Applications Specifications Model LZSA500 LZSA1000 LZSA1500 Input Voltage (47-440Hz) (*) 85 - 265VAC (LZSA1500 - see output derating graphs on page 2), 100-380VDC (1) Inrush Current (110 / 220VAC) A 25 / 45A 30 / 40A Power Factor EN61000-3-2 Class A Efficiency (typical) % 84% Ripple & Noise (Pk-Pk)(max) 75mV 75mV 24V: 75mV; 48V: 150mV Line Regulation % 0.1% Load Regulation % 0.1% Transient Response 1% deviation, recovering to 0.2% in <1.25ms (25% load change) Overcurrent Protection 110 - 130% Overvoltage Protection V User adjustable from front panel Thermal Protection Internal thermostat. Recycle AC to reset Hold Up Time at 110VAC ms 20ms Hold Up, 20ms Ride Through Remote Sense Compensates for a total of 1V cable drop Remote Adjust Using front panel potentiometer, Resistance (1k/V), or Voltage (1V/V) Remote On / Off TTL compatible, active high Signals Optocoupled transistor for AC Fail, DC Good, Inverter OK. 200kHz sync signal (Ref-sense) Indicators Green LED indicates output good, red LED indicates overvoltage or over temperature Parallel Connection Single wire current share Operating Temperature C -40 to +71C, derate linearly to 60% load from 60C~71C (20 min warm up period needed for <-30C) Storage Temperature C -40 to +85C Temperature Coefficient 0.01%/C Humidity (non condensing) %RH 10 - 90%RH Cooling Internal fan Withstand Voltage Input - Ground 2,121VDC, Input - Output 4,242VDC, Output - Ground 500VDC Vibration MIL-STD-810E, Method 514.4, Category 1, 9 Shock MIL-STD-810E, Method 516.4 Proc. I, II, IV, VI Safety Agency Certifications - UL/CSA60950-1, UL508, EN60950-1, FM 3600, 3611, 3810, & CE Mark. SEMIF47(>100VAC) Leakage current uA <500uA at 265VAC, 60Hz Emissions EN55022/EN55011 Class B, EN61000-3-3, MIL STD 461/462D CE102 Immunity EN61000-4-2, -3, -4, -5, -6, -8, -11. IEEE C62.41 (6kV/30 Ohm, Criteria A) Altitude m 3,000m operating, 12,000m non operating Weight lbs 6.5 8.1 Size (WxHxD)(w/o bus bars) ins 4.25 x 4.75 x 10.25 5.62 x 4.75 x 10.5 Warranty yrs Five Years (1) Startup > 110VDC Notes: (Consult Installation Manual for detailed specifications, test methods and application notes) (*) Reduced power factor above 63Hz 1-800-526-2324 * www.us.tdk-lambda.com/lp/ 37 Disclaimer: us.tdk-lambda.com/lp/legal.htm LZSA Series Derating Charts LZSA1500-3 (Obsolete) LZSA1500-3 Output Power Derating vs Input Voltage 1600 1400 1400 800 600 400 1200 1000 800 600 400 200 0 0 5 10 5 11 5 12 5 13 5 14 5 15 5 16 5 17 5 18 5 1 5 20 5 21 5 22 5 23 5 24 5 25 5 26 5 85 200 50 Ambient 60 Ambient 70 Ambient AC Input Voltage 50 60 70 Ambient Ambient 17 5 18 5 1 5 20 5 21 5 22 5 23 5 24 5 25 5 26 5 1000 5 1200 10 5 11 5 12 5 13 5 14 5 15 5 16 5 Output Power (W) 1600 85 Output Power (W) LZSA1500-3-001 & LZSA1500-4 Output Power Derating vs Input Voltage AC Input Voltage Outline Drawing (LZSA1500) Options Model LZSA1000-2 LZSA500-3 LZSA1000-3 LZSA1500-3 LZSA1500-3-001 LZSA1500-4 Other Industrial Products Nominal Voltage (V) Adjustment Range (V) Maximum Current (A) Maximum Power (W) 12 24 24 24 24 48 10 - 15.75 18 - 29.4 18 - 29.4 18 - 29.4 18 - 29.4 36 - 56 84 21 42 63 63 31.5 1008 504 1008 1512 1512 1512 HWS DLP, DPP, DSP PFE 15W to 1800W Single Output 15W to 960W DIN Rail 300W to 1000W Power Modules For Additional Information, please visit us.tdk-lambda.com/lp/products/lzsa-series.htm *Model highlighted in blue is obsolete. Please use LZSA1500-3-001. 1-800-526-2324 * www.us.tdk-lambda.com/lp/ 38 Revision B7.1: May 2014