3 Scotch-WeldTM Hot Melt Applicator PG II LT Owner's Manual Aplicador por fusion al calor de Scotch-WeldTM PG II LT de 3MTM Manual del usuario Manuel de l'utilisateur - Applicateur d'adhesif thermo-fusible PG II LT 3MTM Scotch-WeldTM Use only with 3MTM Scotch-WeldTM Hot Melt LM Adhesives Uselo solamente con adhesivos de fusion al calor Scotch-WeldTM LM de 3MTM A utiliser uniquement avec les adhesifs thermo-fusibles LM 3MTM Scotch-Weld TM General Information Important Safety Instructions..........................................................................1 General Information........................................................................................2 Set Up and Installation....................................................................................3 Operation.........................................................................................................5 Preventive Maintenance ..................................................................................7 Troubleshooting ..............................................................................................9 Repair Part Kits .............................................................................11 Repair Procedures .........................................................................................13 General Assembly (Schematic).....................................................................20 Electrical Control/Wiring Arrangement........................................................21 Flow Control .................................................................................................22 Accessories....................................................................................................23 Repair Service ...............................................................................................24 Important Notice ...........................................................................................24 Warranty and Limitation of Remedies..........................................................24 Limitation of Liability...................................................................................24 3M Sales Branches.........................................................................Back Cover Important Safety Instructions SAVE THESE INSTRUCTIONS Read instructions thoroughly before operating or performing any maintenance on 3MTM Scotch-WeldTM Hot Melt Applicator PG II LT. ! Danger Do not modify the plug provided with the 3M Scotch-Weld Hot Melt Applicator PG II LT. Improper grounding connection of the plug may cause electrical shock. Check with a qualified electrician or service person to determine whether the plug is properly grounded. ! Caution Use only an approved extension cord with 3M Scotch-Weld Hot Melt Applicator PG II LT. Use of improper extension cord may cause electrical shock. Use an extension cord that complies with NEC requirements and state and local electrical requirements. ! Caution ! Caution Contact with molten adhesive or hot applicator tip or metal components may cause burns. Wear heatresistant gloves and safety glasses when operating or repairing the 3M Scotch-Weld Hot Melt Applicator PG II LT. ! Important Do not connect 3M Scotch-Weld Hot Melt Applicator PG II LT to air supply with air pressure greater than 80 psi. Damage to the applicator may result. ! Important Use 3MTM Scotch-WeldTM Hot Melt LM Adhesives only. Use of other adhesives may damage the applicator or result in hazardous conditions. Disconnect air and electrical power and make sure applicator is at room temperature before servicing 3M Scotch-Weld Hot Melt Applicator PG II LT. Failure to disconnect air and electrical power before servicing may cause electrical shock or damage to the applicator. 1 (c) 3M 2006 General Information READ INSTRUCTIONS THOROUGHLY BEFORE OPERATING OR PERFORMING ANY MAINTENANCE ON 3MTM SCOTCH-WELDTM HOT MELT APPLICATOR PG II LT. The 3MTM Scotch-WeldTM Hot Melt Applicator PG II LT is designed to be a simple, reliable tool for dispensing 3MTM Scotch-WeldTM Hot Melt LM Adhesive Sticks. ! Important Use 3M Scotch-Weld Hot Melt LM Adhesives only. Use of other adhesives may damage the applicator or result in hazardous conditions. It is self-contained and hand held, designed for multistation or intermittent manual adhesive application. The 3M Scotch-Weld Hot Melt Applicator PG II LT uses electric heat to melt the adhesive, and air pressure to deliver the adhesive. Adhesive temperature is automatically maintained by a fixed thermostat on the heat block. The system is further protected by a thermal cutout (TCO), which acts as a thermal fuse. Please take time to properly fill out and return your 3M Scotch-Weld Hot Melt Applicator PG II LT Warranty Card. (c) 3M 2006 When trigger (1) is pulled, the variable regulator (2) allows air pressure into rear of the Speedloader stick feed (3). Air pushes the piston (4), which advances adhesive stick through applicator. As adhesive advances, it passes through hard plastic insulating sleeve (5) which acts as thermal barrier to keep molten adhesive and heat in forward portion of the applicator. The rest of the applicator stays cool. As adhesive advances into the heat block, it is melted and liquefied. With pressure from the solid adhesive sticks and the piston, the liquid adhesive is forced out of the applicator through the nozzle tip (6). When the trigger is released, air pressure is released from the rear of the loading chamber. Pressure on the molten adhesive in the front of the applicator is then also relieved. Spring tension in the nozzle valve retracts the valve, neatly cutting off the adhesive flow. The delivery rate of molten adhesive for the 3M Scotch-Weld Hot Melt Applicator PG II LT is approximately six pounds per hour with 3MTM Scotch-WeldTM Hot Melt Adhesive 3762-LM utilizing the standard tip 9921. Adhesive flow rates will vary with the different 3M adhesives in the line and the nozzle tip you choose. 2 Setup and Installation 1. Remove the 3MTM Scotch-WeldTM Hot Melt Applicator PG II LT from its shipper and inspect for obvious damage. 2. Connect Air and Electrical Service Select a work station where 120 VAC grounded receptacle and compressed air service are available. Grounding Instructions The 3M Scotch-Weld Hot Melt Applicator PG II LT must be grounded. If it should malfunction or break down, grounding provides a path of least resistance for electric current to help reduce the risk of electrical shock. This applicator is equipped with a cord having an equipment-grounding conductor and grouding plug. This plug must be used with appropriate outles that are properly installed and grounded in accordance with all local codes and ordinances. The 3M Scotch-Weld Hot Melt Applicator PG II LT is designed for use on a nominal 120-volt circuit and has a grounding plug as shown in illustration above. Make sure the applicator is connected to an outlet having the same configuration as the plug. No adaptor should be used. 3 ! Danger Do not modify the plug provided with the 3M Scotch-Weld Hot Melt Applicator PG II LT. Improper grounding connection of the plug may cause electrical shock. Check with a qualified electrician or service person to determine whether the plug is properly grounded. Electrical outlet should be as close to air supply as possible. Filtered air regulated to 80 psi maximum is vital to optimum operation. Important ! Do not connect 3M Scotch-Weld Hot Melt Applicator PG II LT to air supply with air pressure greater than 80 psi. Damage to the applicator may result. Refer to step 3 on page 4 for air filter and regulator installation procedure. Connect air hose using two 1/2'' open-end wrenches. Remove the steel swivel portion of the connector and insert the steel swivel into 1/8'' female pipe thread air source. Insert and tighten the brass fitting into the swivel and snug up all fittings. (c) 3M 2006 Setup and Installation 3. Install Air Filter and Regulator An air filter and moisture trap must be installed at the applicator connection point of the air system. Install an air filter WATTS #602-2S Model M4 or equivalent at the air outlet or as close as possible to it. The hose connection at the end of the 3MTM Scotch-WeldTM Hot Melt Applicator PG II LT air hose is 1/8'' standard male pipe fitting. (c) 3M 2006 4. Install Bench Stand Prior to start up in operation, set the bench stand on work surface so that tip of the applicator points away from work area when applicator is not in use. When bench stand is in most desirable position, fasten permanently using the screws provided. (If portability of the bench stand is desired, simply attach the stand to a piece of scrap wood approximately 7'' x 16'' using either screws or by adhering the stand to the wood.) 4 Operation Warm Up Set the off/on switch to the "on" position and set the 3MTM Scotch-WeldTM Hot Melt Applicator PG II LT in the bench stand for approximately 15 minutes. During this warm-up period you may note a slight dripping from the nozzle tip. This dripping is due to expansion of the adhesive during warm-up. ! Caution Contact with molten adhesive or hot applicator tip or metal components may cause burns. Wear heatresistant gloves and safety glasses when operating or repairing the 3M Scotch-Weld Hot Melt Applicator PG II LT. Loading ! Important Use 3MTM Scotch-WeldTM Hot Melt LM Adhesives only. Use of other adhesives may damage the applicator or result in hazardous conditions. After warm-up, load applicator with the 3M Scotch-Weld Hot Melt LM Adhesive you'll be using on the job. To do this, fully retract the Speedloader piston by pulling one of the retract knobs located on either side of the loading chamber. Insert up to three 3M ScotchWeld Hot Melt LM Adhesive Sticks into the chamber through the rear loading port. The applicator is now ready for operation. Note Do not depress trigger on the applicator unless there is adhesive in the loading chamber. Damage to the applicator may result. 5 As adhesive is extruded, the piston will move forward. This will be visually evident by the forward movement of the retract knobs. As the piston approaches the front of the chamber, a whistling sound will be heard. At this point the piston may be retracted and another adhesive stick will fall into place. The applicator is again ready for operation. Adhesive may be loaded into the chamber via the rear port at any time during operation thus saving time and increasing productivity. If it is desired to remove adhesive once it is in the loading chamber, simply roll the applicator to one side and then point up. This will allow the adhesive to roll up and out of the chamber. In order to keep the Speedloader stick feed operating at maximum efficiency, the chamber should be sprayed inside while the piston is in the full forward position with 3MTM Silicone Lubricant or equivalent once a week. Application Get a feel for your new 3M Scotch-Weld Hot Melt Applicator PG II LT. Start by applying small amounts of adhesive in puddles on a piece of scrap or paper. Try feathering the trigger. The 3M ScotchWeld Hot Melt Applicator PG II is unique in this respect. Pull the trigger back slowly and note a small discharge of adhesive; pull the trigger back more and note increasing adhesive flow. When the trigger is fully depressed; you will get maximum flow. If more or less flow is desired, refer to page 22 of this manual. Note Do not operate the applicator without a nozzle tip. Damage to the applicator may result. (c) 3M 2006 Operation Changing Tips ! Caution Contact with molten adhesive or hot applicator tip or metal components may cause burns. Wear heatresistant gloves and safety glasses when operating or repairing the 3MTM Scotch-WeldTM Hot Melt Applicator PG II LT. Tips can be changed only when the applicator is hot. You will need a 5/8'' and a 1/2'' open-end wrench. Hold the nozzle valve hex firmly with the 5/8'' wench, while removing the nozzle tip with the 1/2'' wrench. The accessory tip is mounted using the reverse procedure. Snug the tip lightly. Note Do not tighten the tip. Overtightening could damage the valve assembly. The 3M Scotch-Weld Hot Melt Applicator PG II LT includes a 9921 (.093'') tip as standard equipment. Other tips, available from your 3M Scotch-Weld Hot Melt Adhesive distributor, are shown on page 22 of this manual. Note Disconnect air supply before changing tips. (c) 3M 2006 6 Preventive Maintenance Before Operation 1. Make sure filtered compressed air is available, regulated to a maximum of 80 psi or to a minimum of 40 psi. DO NOT OPERATE 3MTM SCOTCH-WELDTM HOT MELT APPLICATOR PG II LT BELOW 40 PSI. If low flow is experienced at 40 psi see page 9, Troubleshooting. ! Caution Contact with molten adhesive or hot applicator tip or metal components may cause burns. Wear heat-resistant gloves and safety glasses when operating or repairing the 3M Scotch-Weld Hot Melt Applicator PG II LT. 4. Be sure there is adhesive in the loading chamber. 5. Under normal conditions, allow at least 15 minutes for the applicator to warm up. Note If proper shutdown procedure has not been followed (see Preventive Maintenance, "After Operation," page 8), up to one hour heat up prior to use may be required. 2. Make sure that the 3M Scotch-Weld Hot Melt Applicator PG II LT is plugged into 120 VAC and that the switch is in the "on" position. TM eld -W or P tch plicat Scoelt Ap Ho 3. Inspect nozzle tip daily. Make sure tip is clean and clear of foreign matter. Using a coarse cloth, wipe off any accumulated adhesive or other foreign matter on the tip. 7 tM 6. Under normal operations the in-line air filter should be removed and cleaned every six months (some air systems may require more periodic changing). Simply remove the filter from the air supply line and blow compressed air through the filter in reverse of normal air flow to remove particular matter. 7. Periodically inspect the applicator to ensure that assembly is proper (i.e. watch for loose screws, worn pins, etc). See page 9 through 19 for Troubleshooting and Repair Procedures. (c) 3M 2006 Preventive Maintenance During Operation TM eld P h-W or otc licat Sc t App Hot Mel After Operation Before shutting down the 3M Scotch-Weld Hot Melt Applicator PG II LT, put the electrical switch in the "off" position. Continue using the applicator until approximately one adhesive stick has been discharged. Note If proper shutdown procedure has not been followed, up to one hour heat up prior to use may be required. Always use the bench stand provided when 3MTM Scotch-WeldTM Hot Melt Applicator PG II LT is not in use. Do not lay the applicator on its side. This impedes cooling process and may cause plugging problems. Lubricate inside loading chamber with 3MTM Silicone Lubricant or equivalent once a week. Open adhesive cartridge stick only when necessary. Keep sticks clean and free from airborne contaminants. (c) 3M 2006 8 Troubleshooting Problem Low or no adhesive flow Probable Cause (In order of priority) 1. Hung adhesive stick Correction Turn on the 3MTM Scotch-WeldTM Hot Melt Applicator PG II LT and allow it to heat for at least 60 minutes. ! Caution Contact with molten adhesive or hot applicator tip or metal components may cause burns. Wear heatresistant gloves and safety glasses when operating or repairing the 3M Scotch-Weld Hot Melt Applicator PG II LT. With incoming air at 80 psi extrude adhesive. If unsuccessful remove nozzle assembly and extrude one stick of adhesive. Readjust incoming air to desired pressure. 2. Low air pressure Check to see if there is sufficient air pressure. Test by setting pressure at 80 psi. Check in-line filter to ensure that it is not plugged with contaminants. Disconnect in-line filter from air hose. Using a compressed air line, blow compressed air through the filter in the reverse flow position. If this does not increase air flow through the filter, swivel filter should be replaced. 3. No electricity Check to see that electrical service is live, and that lighted switch is in "on" position. 4. Dirty nozzle valve assembly Remove nozzle valve and clean. Run one adhesive stick out. Replace cleaned valve assembly. This step should only be done while tip is hot ! Caution Contact with molten adhesive or hot applicator tip or metal components may cause burns. Wear heatresistant gloves and safety glasses when operating or repairing the 3M Scotch-Weld Hot Melt Applicator PG II LT. 5. Regulator malfunction 9 Squeeze trigger and try to pull retract knobs. If they can be pulled back easily, install new regulator kit. (c) 3M 2006 Troubleshooting Problem Low or no adhesive flow (cont.) Probable Cause (In order of priority) 6. Burned out heater(s) Correction With Volt/Ohm Meter, run electrical continuity check on each heater (see page 17 for repair procedure). If open circuit exists, install new heater kit. ! Caution Disconnect air and electrical power and make sure applicator is at room temperature before servicing 3MTM Scotch-WeldTM Hot Melt Applicator PG II LT. Failure to disconnect air and electrical power before servicing may cause electrical shock or damage to the applicator. No heat Dripping Nozzle (c) 3M 2006 7. Jammed adhesive sticks If the piston is retracted before reaching the point where the whistle is heard, a jam-up of the adhesive may occur. To free this, simply retract the piston fully and roll the applicator to one side so that the adhesive in the magazine will free itself. Now push the knobs forward until the adhesive stick still in the chamber is contacted by the piston. Roll the applicator back to its normal operating position and continue extruding adhesive until the whistle is heard or until the piston has traveled its full length as indicated by the orange retract knobs. 1. Blown thermal cutoff Replace with new Thermostat/TCO kit. Refer to page 18, paragraph J. 1. Regulator malfunction With finger off of trigger, attempt to retract piston. If piston is very difficult to pull back, air regulator may not be shutting off entirely. Replace regulator. 2. Expanded adhesive stick Extrude one adhesive stick. 3. Worn nozzle valve Replace with new nozzle valve assembly. Refer to page 14, paragraph C. 10 Troubleshooting Repair Parts Kit For ease and convenience in repair, 3MTM ScotchWeldTM Hot Melt Applicator PG II LT repair part kits are available from your authorized 3M Scotch-Weld Adhesive distributor. When ordering part kits, provide the name and number of the repair part kit. # of Items/ Kit Kit # Repair Part Kit 9200 Trigger Kit a. Trigger Pin b. Trigger Assembly Heat Shield Kit a. Heat Shield Regulator Kit a. Regulator Assembly Regulator Hose Sub-Assembly Kit a. Hose Assembly Power Cord Kit a. Power Cord Assembly b. Cable Ties Thermostat/TCO Kit a. Thermal Cutout Assembly b. Machine Screw Large c. Machine Screw Small d. Thermostat Sub-Assembly 9932 9204 9220 9207 9931 Repair Part Kit 9221 Handle Kit a. Right Handle Sub-Assembly b. Left- Handle Sub-Assembly c. Machine Screw d. Machine Screw Switch Kit a. Switch Sub-Assembly Hose Kit, Main a. Hose Sub-Assembly b. Cable Ties Hose Kit a. Hose b. Elbow c. Swivel Filter d. Cable Ties Heater Kit a. 125 W Heater b. Machine Screw c. Cable Tie Valve Kit a. Nozzle Tip b. Valve Assembly 1 9219 1 9220 1 9220 1 5 9222 9223 11 # of Items/ Kit Kit # 1 1 1 1 2 1 Part kits can also be ordered directly from the nearest 3M Sales Branch listed on the back cover. Kit # Repair Part Kit 9224 Miscellaneous Parts Kit a. Heat Shield Screw, Top b. Heat Shield Screw, Side c. Heat Shield Screw d. Shim e. Electrical Connector Screw f. Connector Strip g. Handle Screw h. Regulator Screw i. Ground Wire Screw j. Hinge Pin k. Bail Screw l. Lock Washer for Bail m. Bail Dump Valve a. Valve Speedloader Hose Assembly a. Hose Assembly Scotch-Weld SL Magazine Extension Kit a. Magazine Extension Speedloader Assembly a. Speedloader b. Hose c. Pin d. Bail 1 1 4 3 1 1 5 1 1 1 5 4 8 1 1 1 # of Items/ Kit 9226 9260 9936 9935 1 2 4 2 9 2 4 3 2 3 2 2 2 1 1 1 1 1 1 1 (c) 3M 2006 Troubleshooting Your 3MTM Scotch-WeldTM Hot Melt Applicator PG II LT has been engineered for durability and reliability. However, as with any electricalmechanical device, parts will wear with use and require replacement for optimum performance. We have listed below certain part kits that you may want to have available in case the immediate need for replacement arises. All part kits listed are available from your authorized 3M Scotch-Weld Hot Melt Adhesive distributor or from the nearest 3M Sales Branch location listed on the back cover of this manual. Please note the serial number of your 3M Scotch-Weld Hot Melt Applicator PG II LT before ordering part kits. No. of Scotch-Weld Hot Melt Applicators in Use 2-5 6-10 11-15 16-20 Kit Number Name 9200 Trigger Kit 62-9200-6921-8 0 0 1 1 9932 Heat Shield Kit 62-9783-9932-7 0 1 1 2 9204 Regulator Kit 62-9204-6922-8 1 1 2 2 9207 Power Cord Kit 62-9207-6947-8 0 0 0 1 9931 Thermostat/TCO Kit 62-9783-9931-9 1 2 2 3 9219 Switch Kit 62-9219-2798-4 0 0 1 1 9220 Hose Kit 62-9220-2797-4 0 0 0 1 9221 Handle Kit 62-9221-2651-1 0 0 0 1 9222 Heater Kit 62-9222-6930-3 0 0 1 1 9223 Valve Kit 62-9223-6930-1 1 2 3 4 9226 Dump Valve Kit 62-9226-6990-8 0 0 1 1 9260 S/L Hose Assem. Kit 62-9260-2945-5 0 0 1 1 (c) 3M 2006 12 Repair Procedures ! Handle Disassembly Instructions Caution Disconnect air and electrical power and make sure applicator is at room temperature before servicing 3MTM Scotch-WeldTM Hot Melt Applicator PG II LT. Failure to disconnect air and electrical power before servicing may cause electrical shock or damage to the applicator. Procedure A. Handle Kit Part Kit A. Handle Kit B. Regulator Kit C. Valve Kit D. Hose Kit E. Power Cord Kit F. Switch Kit G. Trigger Kit H. Heat Shield Kit I. Heater Kit J. Thermostat/TCO Kit K. Heat Block Kit Remove heat shield (see procedure H, page 16). With the nozzle of the applicator pointing away from you, remove the seven Phillips head cap screws in the handle. These screws are located in the left hand side of the handle grip, two in the pistol grip itself, two just forward of the wire terminal and three to the rear of the wire terminal. Without removing the wires from the wire terminals, lift the handle up and to the front of the applicator. This operation will allow for subsequent repair steps. To replace applicator handles, first follow "Handle Disassembly Instructions." Next remove the electrical wiring from the terminal strip on the left handle, replacing them to the same terminals on the replacement. The right half of the handle is removed by removing the four Phillips head cap screws. Next remove the electrical wiring from the terminal strip and re-assemble these to the replacement right half handle. Lift the switch out of its slot in the handle and replace it in the new handle. Replace the trigger and trigger pin at this time. Using reverse procedure, reassemble the right handle half, then the left. Be sure all the electrical wires are in place and are not being pinched. 13 (c) 3M 2006 Repair Procedures C. Valve Kit B. Regulator Kit ! Caution ! Caution Disconnect air and electrical power and make sure applicator is at room temperature before servicing 3MTM Scotch-WeldTM Hot Melt Applicator PG II LT. Failure to disconnect air and electrical power before servicing may cause electrical shock or damage to the applicator. Contact with molten adhesive or hot applicator tip or metal components may cause burns. Wear heatresistant gloves and safety glasses when operating or repairing the 3M Scotch-Weld Hot Melt Applicator PG II LT. First follow "Handle Disassembly Instructions," Procedure A on page 13. Then remove the two large Phillips head screws to the rear of the wire terminals on the right hand side of the handle. This allows the regulator assembly to swing free, connected only by the hose going from the brass rear of the regulator to the loading chamber assembly, and then main hose assembly. Remove the main hose by unscrewing the elbow fitting from the regulator. Use a 5/16'' wrench to remove the loading chamber hose from the regulator. Reassemble with a new regulator using reverse procedure. Be sure hose fittings are quite snug. Check for air leaks by activating the regulator. Once this is done, reassemble the handle and heat shield. 3M Scotch-Weld Hot Melt Applicator PG II LT must be warm prior to repairing nozzle valve. Nozzle valve assembly consists of the nozzle tip and the nozzle valve. Remove the old valve assembly using a 5/8'' open-end wrench. Replace with new assembly. Gently snug up the valve assembly. With a 1/2'' wrench, also snug up the new tip. D. Hose Kit ! Caution Disconnect air and electrical power and make sure applicator is at room temperature before servicing 3M Scotch-Weld Hot Melt Applicator PG II LT. Failure to disconnect air and electrical power before servicing may cause electrical shock or damage to the applicator. Follow "Handle Disassembly Instructions," Procedure A on page 13. Remove the main hose by unscrewing the elbow fitting from the air regulator. Cut the cable ties holding the power cord and hose assembly together. Remove the hose and reconnect the new hose using reverse procedure. Add new cable ties to the hose and power cord. (c) 3M 2006 14 Repair Procedures E. Power Cord Kit ! Caution Disconnect air and electrical power and make sure applicator is at room temperature before servicing 3MTM Scotch-WeldTM Hot Melt Applicator PG II LT. Failure to disconnect air and electrical power before servicing may cause electrical shock or damage to the applicator. Follow "Handle Disassembly Instructions," Procedure A on page 13. The power cord wire from the switch is removed from the bayonet connector. The black and white wires are removed from their respective terminals. Remember which wire came off which terminal for reassembly. Consult the electrical wiring arrangement on page 21. Reassemble, following reverse procedure. F. Switch Kit Follow "Handle Disassembly Instructions," Procedure A on page 13. Lift the switch from the slot in the right half of the handle. The power lead can be unplugged from the power cord receptacle. The other wires terminating in ring lugs should be removed from their respective terminals, noting that the black lead is connected to the Thermal Cut Out Assembly and the white lead to the heaters. Install the new switch using reverse procedure. G. Trigger Kit ! Caution Disconnect air and electrical power and make sure applicator is at room temperature before servicing 3M Scotch-Weld Hot Melt Applicator PG II LT. Failure to disconnect air and electrical power before servicing may cause electrical shock or damage to the applicator. Follow "Handle Disassembly Procedures," Procedure A on page 13. Lift the trigger assembly off the trigger pin and replace. Reassemble, following reverse procedure. ! Caution Disconnect air and electrical power and make sure applicator is at room temperature before servicing 3M Scotch-Weld Hot Melt Applicator PG II LT. Failure to disconnect air and electrical power before servicing may cause electrical shock or damage to the applicator. 15 (c) 3M 2006 Repair Procedures Heat Shield Disassembly I. Heater Kit H. Heat Shield Kit ! ! Caution Disconnect air and electrical power and make sure applicator is at room temperature before servicing 3MTM Scotch-WeldTM Hot Melt Applicator PG II LT. Failure to disconnect air and electrical power before servicing may cause electrical shock or damage to the applicator. Remove the heat shield assembly by removing the two Phillips head screws from either side of the heat shield and the one Phillips head screw on the heat shield immediately above the loading chamber. Reassemble, following reverse procedure. (c) 3M 2006 Caution Disconnect air and electrical power and make sure applicator is at room temperature before servicing 3M Scotch-Weld Hot Melt Applicator PG II LT. Failure to disconnect air and electrical power before servicing may cause electrical shock or damage to the applicator. Follow "Heat Shield Disassembly, "per procedure H. All heater wires must be disconnected from their respective terminal strips. With a suitable drift punch, drive the old heaters out through the top of the heat block. All four heaters should be replaced making sure to reconnect the wires in the proper places. Refer to the "Wiring Arrangement" and "Electrical Control" diagrams, page 21. Be sure that heaters are bottomed out in the heat block. They should not stick out above the block more than 1/4''. It may be necessary to gently tap the heaters into place, but be careful not to crack the ceramic. To ensure that heaters remain in place, gather all the wires together approximately 1/2'' below the heat block and tightly attach the cable tie provided with the kit. 16 Repair Procedures Heater Check-Out ! Use Volt/Ohm Meter to check electrical continuity of each heater. If continuity exists, heater is okay. First remove heat shield. Heaters need not be removed from the block. Check in the following sequence: left front, right front, right rear, left rear. To start the check, remove only one wire from its connection on the terminal strip. Caution Disconnect air and electrical power and make sure applicator is at room temperature before servicing 3MTM Scotch-WeldTM Hot Melt Applicator PG II LT. Failure to disconnect air and electrical power before servicing may cause electrical shock or damage to the applicator. Place one probe from the meter on the connector of the wire that has been removed, and with the other probe, touch the matching connector on opposite side of the applicator. If needle on Volt/Ohm Meter swings, heater is okay. Reconnect wire that was removed first, and continue sequence. If one or more heaters are burned out, refer to Repair Procedure, pages 13 through 19. 17 (c) 3M 2006 Repair Procedures J. Thermostat/TCO Kit Remove the heat shield assembly by removing the two Phillips head screws from either side of the heat shield and the one Phillips head screw on the heat shield immediately above the loading chamber. The thermostat and TCO are assembled as a unit and are replaced as such no matter which component has failed. The Quick-Slide clips should be removed from the thermostat. Remove the two screws holding the thermostat, and pry the thermostat from the block. ! Caution Disconnect air and electrical power and make sure applicator is at room temperature before servicing 3MTM Scotch-WeldTM Hot Melt Applicator PG II LT. Failure to disconnect air and electrical power before servicing may cause electrical shock or damage to the applicator. (c) 3M 2006 Insert new thermostat. Make sure the rear rim of the thermostat is slipped into the slot in the heat block before affixing screws. The thermal cutout assembly is then removed by disconnecting the Phillips head screw, holding the thermal cutout to the head block on the stand off strip. Remove the other end of the thermal cutout from the terminal strip with a small Phillips screwdriver. Procedure is reversed to replace the thermal cutout. 18 Repair Procedures K. Heat Block Kit ! Caution Disconnect air and electrical power and make sure applicator is at room temperature before servicing 3MTM Scotch-WeldTM Hot Melt Applicator PG II LT. Failure to disconnect air and electrical power before servicing may cause electrical shock or damage to the applicator. If the original heat block is broken or needs replacement, you may use the 3M factory refurbish program. Please contact your distributor for information on our PG II LT equipment refurbish program. 19 (c) 3M 2006 General Assembly I M L J J C H K B F A E E D A G A. 9221 Handle Kit F. 9219 Switch Kit K. 9260 Speedloader Hose Assembly B. 9204 Regulator Kit G. 9220 Trigger Kit L. 9226 Dump Valve Kit C. 9223 Valve Kit H. 9932 Heat Shield Kit M. 9935 Speedloader Chamber Assembly D. 9220 Hose Kit I. 9222 Heater Kit E. 9207 Power Cord Kit J. 9931 Thermostat/TCO Kit (c) 3M 2006 20 General Assembly Electrical Control 20 Wiring System 21 (c) 3M 2006 Flow Control Flow control of adhesive with your new 3MTM ScotchWeld TM Hot Melt Applicator PG II LT is easy. Any operator familiar with the control devices should be able to adjust the applicator for desired flow. To adjust adhesive flow, a combination of these control methods can be used. The four control devices are: 1. Speed of 3M Scotch-Weld Hot Melt Applicator PG II LT movement. 2. The trigger. 3. The applicator tip. 3M Scotch-Weld Hot Melt Applicator PG II LT Tips Tip No. Description 9913 2 Hole Spreader 9916 3 Hole Spreader 9917 3 Hole 1'' Spreader 9921 .093'' Fluted 9922 .063'' Fluted 9726 "T" Tip P/G II 9940 .125'' Fluted Tip 9946 .072'' Brass Extension 9727 "L" Tip P/G II 4. Air pressure. The trigger of the applicator is uniquely designed to allow for variable adhesive control. By pulling the trigger slowly to the rear, you can observe the start of adhesive flow. As you continue to pull the trigger rearward, increasing amounts of adhesive are dispensed. Your 3M Scotch-Weld Hot Melt Applicator PG II LT is equipped with a 9921 (.093'') tip as a standard equipment. This tip will provide maximum flow for all 3MTM Scotch-WeldTM Hot Melt LM Adhesives. The brass extension tip (9946) will allow for maximum control of all the 3M Scotch-Weld Hot Melt LM Adhesives and substantially reduce initial surge. This is accomplished at a decrease in flow rate. Speed of movement is the preferred means to control flow. In the event that this is inappropriate for your operation, additional accessory tips are available. 9726 Tip 9727 Tip 9726 "T" tip for RSC carton closing and other uses. 9727 "L" tip for FOL carton closing and other uses. 9945 Stand Note DO NOT REDUCE AIR PRESSURE BELOW 40 PSI. If low adhesive flow occurs when operating at reduced air pressure, return to maximum (80 psi) and run at least one cartridge of adhesive through the applicator and then return to the lower pressure. (c) 3M 2006 9945 heavy-duty bench stand holds 3M Scotch-Weld Hot Melt Applicator PG II LT in proper position when the applicator is not is use. 22 Accessories Bench Mounted Systems for 3MTM Scotch-WeldTM Hot Melt Applicator PG II LT Bench mounted 3M Scotch-Weld Hot Melt Applicator PG II LT with Speedloader Magazine Feed. A special bench mount assembly is available which allows the 3M Scotch-Weld Hot Melt Applicator PG II LT to be mounted in a 45 position and operated with a foot pedal. It is adjustable to allow positioning of the nozzle tip from a minimum of 9 1/2'' to a maximum of 15 1/2'' from the bench top. A nozzle adapter that directs adhesive flow straight down is included in addition to the foot pedal unit. Speedloader Magazine Feed for 3M Scotch-Weld Hot Melt Applicator PG II LT The 3M Scotch-Weld Hot Melt Applicator PG II LT can be modified into a semi-automatic loading mode by the addition of the Speedloader Magazine Feed. By simply pushing a lever to the rear, the magazine feeds a new stick of adhesive into the melt chamber. The magazine holds 12 3MTM Scotch-WeldTM Hot Melt LM Adhesives Sticks, reduces the need for frequent reloading and helps increase production. It is ideal for hands-free benchtop applications in packaging and assembly. 23 (c) 3M 2006 3M Repair Service During warranty period Contact your nearest 3M Sales Branch or 3MTM Scotch-Weld TM Hot Melt Adhesives distributor After warranty period The 3MTM Scotch-WeldTM Hot Melt Applicator PG II LT has been engineered to be durable and reliable. Recognizing that it will eventually need maintenance, we have made it easy to disassemble and repair. Step by step repair instructions are detailed in this manual, pages 13 thru 19. Also provided are simple line drawings and exploded views. Should your 3M Scotch-Weld Hot Melt Applicator PG II LT require repair, you can order repair part kits from your local 3M Scotch-Weld Hot Melt Adhesives distributor or from the nearest 3M Sales Branch listed on the back cover. If you do not wish to make your own repair, check with your local distributor. Many of our 3M Scotch-Weld Hot Melt Adhesives distributors have in-house repair capability. 3M offers a "Refurbish Program." Information on costs and details on 3M's Refurbishing Program can be obtained by contacting your nearest 3M Sales Branch. RoHS compliant means that the product or part does not contain any of the substances in excess of the maximum concentration values in EU Directive 2002/95/EC, as amended by Commission Decision 2005/618/EC, unless the substance is in an application that is exempt under RoHS. Unless otherwise stated by 3M in writing, this information represents 3M's knowledge and belief based on information provided by third party suppliers to 3M. (c) 3M 2006 Important Notice: User is responsible for determining whether the 3M Scotch-Weld Hot Melt Applicator PG II LT is fit for a particular purpose and suitable for user's method of application. Warranty: 3M warrants for a period of 12 months from the date of use or purchase, whichever occurs first, that the 3M Scotch-Weld Hot Melt Applicator PG II LT will be free of defects in material and workmanship. 3M MAKES NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR ANY IMPLIED WARRANTY ARISING OUT OF A COURSE OF DEALING, CUSTOM, OR USAGE OF TRADE. This warranty does not cover routine maintenance, normal wear and tear, or damage resulting from accident, misuse, alteration, corrosion, lack of reasonable care, service performed by an unauthorized repair service, use of unauthorized replacement parts or accessories, installation, use, operation, or maintenance not in accordance with 3M recommended procedures, or use of adhesive cartridges not manufactured by 3M or not subject to 3M quality standards. Limitation of Remedies: If the 3M ScotchWeld Hot Melt Applicator PG II LT is proved to be defective within the warranty period stated above, THE EXCLUSIVE REMEDY, AT 3M'S OPTION, SHALL BE TO REFUND THE PURCHASE PRICE OF OR TO REPAIR OR REPLACE THE DEFECTIVE 3M APPLICATOR, provided that the defective applicator is, at 3M's choice, returned immediately to 3M or an authorized service representative designated by 3M, or made available at user's premises in a location suitable for servicing. Limitation of Liability 3M shall not otherwise be liable for any losses or damages, whether direct, indirect, special, incidental or consequential, regardless of the legal or equitable theory asserted, including contract, negligence, warranty, or strict liability. 24 Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: 3M: 9946