Specification Control Drawing 55M1411 Issue 3 4th September 2009 Page 1 of 2 Page 2 is for internal use only ONE CONDUCTOR CABLE, MODIFIED FLUOROPOLYMER INSULATED, SHIELDED AND JACKETED, 450 VOLT, 150C, LIGHTWEIGHT The complete requirements for procuring the wire described herein shall consist of this document. Shield Tin Coated Copper Coverage 85% minimum Component wire - Jacket - 55M0411 Radiation Crosslinked Modified ETFE C7 Part Description C8 Wire Size C9 Shield Size (mm) 55M1411-30-*-* 55M1411-28-*-* 55M1411-26-*-* 55M1411-24-*-* 55M1411-22-*-* 55M1411-20-*-* 30 28 26 24 22 18 0.08 0.08 0.08 0.08 0.10 0.10 C10 C11 C12 C13 C14 Jacket Thickness Overall Diameter Maximum (mm) (mm) Weight (kg/ km) Min. Nom. Nom. Max. 0.10 0.15 1.16 1.27 3.57 0.10 0.15 1.24 1.36 4.20 0.10 0.15 1.34 1.47 5.24 0.10 0.15 1.46 1.61 6.59 0.15 0.20 1.79 1.97 9.73 0.20 2.02 2.22 13.47 0.15 COLOUR CODE: The '*' in the part number shall be replaced by a standard colour code designator in accordance with BS 6746C. e.g. 55M1411-24-9-9, core white, jacket white PERFORMANCE REQUIREMENTS: To be tested to and meet the requirements of the issue in effect of Raychem Specification WCD 32/1 and Raychem Specification 55A as applicable. ADDITIONAL REQUIREMENTS: Jacket APPROVAL: Electronic sign off - no signatures will appear. Elongation - 50% minimum Tensile Strength - 35 N/ mm minmum Accelerated Ageing - 2.5 kV wet dielectric test (c)2009 Tyco Electronics Corporation. All International Rights Reserved.