Issue 3
Specification Control Drawing 4th September 2009
ONE CONDUCTOR CABLE, MODIFIED FLUOROPOLYMER INSULATED, SHIELDED AND JACKETED,
450 VOLT, 150°C, LIGHTWEIGHT
The complete requirements for procuring the wire described herein shall consist of this document.
Shield -
Tin Coated Copper
Coverage 85% minimum
Component wire -
Jacket -
55M0411 Radiation Crosslinked
Modified ETFE
C8
C9
C10
C11
C12
C13
C14
Wire Shield Jacket Thickness Overall Diameter Maximum
Size Size (mm) (mm) Weight
(mm) (kg/ km)
Min. Nom. Nom. Max.
30 0.08 0.10 0.15 1.16 1.27 3.57
28 0.08 0.10 0.15 1.24 1.36 4.20
26 0.08 0.10 0.15 1.34 1.47 5.24
24 0.08 0.10 0.15 1.46 1.61 6.59
22 0.10 0.15 0.20 1.79 1.97 9.73
18
0.10
0.15
0.20
2.02
2.22
13.47
COLOUR CODE: The '*' in the part number shall be replaced by a standard colour code
designator in accordance with BS 6746C.
e.g. 55M1411-24-9-9, core white, jacket white
PERFORMANCE To be tested to and meet the requirements of the issue in effect of
REQUIREMENTS: Raychem Specification WCD 32/1 and Raychem Specification 55A as applicable.
ADDITIONAL Jacket Elongation - 50% minimum
REQUIREMENTS: Tensile Strength - 35 N/ mm² minmum
Accelerated Ageing - 2.5 kV wet dielectric test
APPROVAL: Electronic sign off - no signatures will appear.
©2009 Tyco Electronics Corporation. All International Rights Reserved.
C7
Part
Description
55M1411-22-*-*
55M1411-20-*-*
55M1411-30-*-*
55M1411-28-*-*
55M1411-26-*-*
55M1411-24-*-*
Page 1 of 2
Page 2 is for internal use only