DRR-129 Features and Benefits
DIMENSIONS (in) mm
Notes 1) For details on electrical specifications,contact Hamlin.
2) Contact rating-Product of the switching voltage and current should never exceed the
wattage rating.
Contact Hamlin for additional load/life information.
3) Operate/Release Time-per EIA/NARM RS421A,diode suppressed coil.
4) Pull in Range-Contact Hamlin for tolerances available within this range.
5) Rating Sensitivity-The value at which contact ratings and operating characteristics are
determined.Derating may be required below this value.
6) Storage Temperature-Long time exposure at elevated temperature may degrade
solderability of the leads.
Switch T ype DRR-129
Contact Form A
Underwriters Laboratories Recognised for AC loads only, File E47258 (see note 1)
ELECTRICAL RATINGS
Contact Rating (2) Watt - max. 100
Voltage Switching Max. 240Vac rms (400Vdc)
Breakdown Vdc - min. 600
Current Switching Adc - max. 3.0
Carry Adc - max. 6.0
Resistance Contact,Initial - max. 0.100
Insulation - min. 1010
Capacitance Contact pF - typ. 0.6
Temperature Operating °C -40 to +125
Storage (6) °C -65 to +125
OPERATING CHARACTERISTICS
Operate Time (3) ms - max. 4.5
Release Time (3) ms - max. 2.5
Shock 11ms 12sine wave G - max. 100
Vibration 50-2000 Hertz G - max. 30
Resonant Frequency Hz - typ. 850
MAGNETIC CHARACTERISTICS
Pull-In Range (4) Ampere Turns 42-83
Rating Sensitivity (5) Ampere Turns 60
Test Coil L4988
Features
Normally open switch size with
50.80mm x 5.25mm (2.0” x
0.207”) glass envelope
Capable of switching up to
400Vdc
Maximum switched current 3
Amps,will carry up to 6 Amps
Maximum contact rating 100 Watts
Minimum v oltage breakdo wn 600Vdc
1010 Ohms insulation resistance
Available sensitivity range 42-83 AT
Benefits
Hermetically sealed switch
contacts are not effected by and
have no effect on their external
environment
Capable of switching European
mains voltage
Low, stable contact resistance
Low space requirement
Zero operating power required
for contact closure
Fit and forget durability
Applications
Security
Limit switching
Automotive applications
Industrial safety applications
INFORMATION PROVIDED ON THIS DATA SHEET IS PROVIDED FOR INFORMATION PURPOSES ONLY AND SHOULD NOT BE RELIED UPON AS BEING ACCURATE FOR ANY
PARTICULAR PURPOSE. Product performance may be affected by the application to which the product is applied. Upon request, HAMLIN will assist purchasers by providing information
specific to any particular application. HAMLIN disclaims any and all liability whatsoever for any purchaser’s reliance upon the information contained on this data sheet without further
consultation with authorised representatives of HAMLIN.
USA Tel: +1 920 648 3000 Fax: +1 920 648 3001 Email: sales.us@hamlin.com
UK Tel: +44 (0)1379 649700 Fax: +44 (0)1379 649702 Email: sales.uk@hamlin.com
Germany Tel: +49 (0) 6142 923920 Fax: +49 (0) 6142 923921 Email: sales.de@hamlin.com
France Tel: +33 (0) 1 6047 3000 Fax: +33 (0) 1 6015 9136 Email: sales.fr@hamlin.com
ISSUE No: 3 DATE: 28/09/0
www.hamlin.com
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Hamlin:
DRR-129 42-53 DRR-129 42-58 DRR-129 52-63 DRR-129 57-78 DRR-129 47-63 DRR-129 52-68 DRR-129 42-68
DRR-129 67-78 DRR-129 47-73 DRR-129 57-68 DRR-129 72-78 DRR-129 57-83 DRR-129 47-58 DRR-129 57-63
DRR-129 52-58 DRR-129 42-73 DRR-129 47-78 DRR-129 72-83 DRR-129 52-78 DRR-129 47-83 DRR-129 42-63
DRR-129 42-78 DRR-129 47-53 DRR-129 77-83 DRR-129 52-73 DRR-129 62-78 DRR-129 52-83 DRR-129 67-83
DRR-129 57-73 DRR-129 62-68 DRR-129 62-73 DRR-129 62-83
Littelfuse:
DRR-129-42-53 DRR-129-47-83 DRR-129-47-78 DRR-129-52-58 DRR-129-57-73 DRR-129-77-83 DRR-129-67-
78 DRR-129-57-68 DRR-129-52-73 DRR-129-42-78 DRR-129-62-83 DRR-129-57-78 DRR-129-42-68 DRR-129-
72-78 DRR-129-42-63 DRR-129-47-53 DRR-129-62-78 DRR-129-47-63 DRR-129-57-83 DRR-129-62-73 DRR-
129-42-58 DRR-129-52-63 DRR-129-42-73 DRR-129-47-73 DRR-129-52-68 DRR-129-52-83 DRR-129-47-58
DRR-129-57-63 DRR-129-72-83 DRR-129-62-68 DRR-129-52-78 DRR-129-67-83