60 Series General Purpose Relays 10 A A range of general purpose relays with 2 CO (DPDT) or 3 CO (3PDT) contacts * PCB mount version available * AC or DC coils * Approvals (according to type): BEAB, CSA, DEMKO, GOST, IMQ, RINA, SEV, cUL, VDE WOOD-PROCESSING MACHINES AUTOMATIC GATES ELEVATORS INDUSTRIAL APPLIANCES MEDICAL EQUIPMENT TOOLING MACHINES PLASTIC MOULDING CERAMIC INDUSTRY MACHINES ON-BOARD SHIP APPLIANCES 57 60 Series General Purpose Relays 10 A TECHNICAL DATA DIELECTRIC STRENGTH between coil and contacts 2,000 V tested at leakage current between open contacts 10 mA for 1 min at 50 Hz between adjacent contacts 1,000 V 2,000 V SURGE TEST (1.2/50 s) 2,500 V between frame and live parts 2,000 V BETWEEN COIL AND CONTACTS ISOLATION RESISTANCE 20 * 103 M ISOLATION GROUP C 250 MAXIMUM SWITCHING FREQUENCY - at rated load 60.43 GOST BEAB RINA - without load (-40 ... +70)C MECHANICAL LIFE 20 * 106 cycles version AC 50 * 106 cycles version DC C OPERATE AND RELEASE TIME 60.42 1 9 36 7.1 10.8 9 6 5.9 4.3 60.43 4 3 1 6 10 4 2 11 5 3 6 8 7 9 7 9 10 60.42 11 60.43 copper side view 3 4 6 6 7 9 9 10 11 10.8 1.5 4.3 5.9 1 60.42 58 7.1 7.1 36 1.5 36 32.2 32.2 18 7.1 15 ms (including contact bounce) TYPE OF RELAY 43 7.1 15 ms (including contact bounce) - drop-out time (UN to 0) DIELECTRIC TEST 6 7.1 - pick-up time (0 to UN) TYPE OF DUTY 32.2 18 IP 40 OF ENCLOSURES P.C.B. RELAYS 10 A TYPE 60.42 2 CO (DPDT) TYPE 60.43 3 CO (3PDT) - Tin plated copper pins (1.2 x 0.5 mm) - Standard contact material: AgNi - Options: see coding table page 62 - Ordering information: see page 62 7.1 1,800 cycles/h AMBIENT TEMPERATURE PROTECTION CATEGORY 32.2 36,000 cycles/h 9 9 7.1 4.3 5.9 1 2 3 4 5 6 6 7 8 9 9 10 11 60.43 10.8 continuous 2 all-or-nothing 60 Series General Purpose Relays 10 A CONTACT SPECIFICATIONS RATED CURRENT 10 A MAXIMUM PEAK CURRENT 20 A NOMINAL RATE IN AC1 2,500 VA NOMINAL RATE IN AC15 500 VA RATED VOLTAGE 250 V AC MAXIMUM SWITCHING VOLTAGE 400 V AC BREAKING CAPACITY IN DC1 see diagram H 60 SINGLE PHASE HP MOTOR RATING 0.37 kW/0.6 HP CONTACT RESISTANCE: - initial 50 m MINIMUM SWITCHING LOAD 500 mW (10 V/5 mA) STANDARD CONTACT MATERIAL AgNi F 60 H 60 7 10 20 MAX SWITCHING CURRENT (A) CYCLES A 106 105 0.5 1 1.5 2 2.5 3 C 6 4 2 1 0.6 0.4 0.2 0.1 0 B 10 20 60 100 140 180 220 VOLTAGE DC (V) LOAD (kVA) Contact life vs AC1 load at 1800 cycles/h. Breaking capacity for DC1 load at 1800 cycles/h. A = load applied to 1 contact B = load applied to 2 contacts in series C = load applied to 3 contacts in series K 60 k REDUCTION FACTOR 1 0.8 k 0.6 0.4 1 0.8 0.6 0.4 0.2 COS Load reduction factor vs cos . 59 60 Series General Purpose Relays 10 A COIL SPECIFICATIONS VERSIONS: AC - alternating current 50/60 Hz DC - direct current AM - current sensing DI - DC coil with a diode in parallel AC RATED POWER 2.2 VA 1.3 W OPERATING RANGE (0.8 to 1.1) UN (0.8 to 1.1) UN HOLDING VOLTAGE 0.8 UN 0.5 UN MUST DROP-OUT VOLTAGE 0.2 UN 0.1 UN NOMINAL MAGNETOMOTIVE FORCE THERMAL INSULATION CLASS OF WIRE THERMAL RESISTANCE CONDUCTED DISTURBANCE IMMUNITY 180 A 250 A F (+155C) F (+155C) 43C/W 43C/W BURST (acc. to EN 61000 - 4 - 4) level 4 (4 kV) SURGE (acc. to EN 61000 - 4 - 5) level 4 (4 kV) AC VERSION DATA R values relate to +20C. Tolerance of R and I values: 10%. Rated voltage UN V 6 12 24 48 60 110 120 230 240 60 DC Operating range Umin V 4.8 9.6 19.2 38.4 48 88 96 184 192 U max V 6.6 13.2 26.4 52.8 66 121 132 253 264 Resistance R 4.6 19 80 320 500 1,800 1,940 7,250 8,500 Nominal coil absorption UN 50 Hz I mA 367 183 91.7 45.8 36.7 20 18.6 9.6 9.2 DC VERSION DATA R values relate to +20C. Tolerance of R and I values: 10%. Operating range Rated voltage UN Umin V 6 12 24 48 60 110 V 4.8 9.6 19.2 38.4 48 88 U max V 6.6 13.2 26.4 52.8 66 121 Resistance R Nominal coil absorption I 28 110 445 1,770 2,760 9,420 mA 214 109 53.9 27.1 21.7 11.7 60 Series General Purpose Relays 10 A COIL SPECIFICATIONS R 60 Umin 70 1 TEMPERATURE RISE "t" (C) UN S 60/1 0.9 0.8 0.7 0.6 60 1.1 UN 50 UN 40 30 0.8 UN 20 10 0.5 0 - 40 -20 0 20 40 60 10 80 20 30 50 60 HEATING TIME (min) AMBIENT TEMPERATURE (C) Temperature rise "t " vs applied voltage. DC coils. DC coil min pick-up voltage vs ambient temperature. Umin = pick-up voltage UN = rated voltage S 60/3 S 60/2 70 70 60 50 1.1 UN 40 UN 30 0.8 UN 20 10 TEMPERATURE RISE "t" (C) TEMPERATURE RISE "t" (C) 40 60 50 1.1 UN 40 UN 30 0.8 UN 20 10 0 10 20 30 40 50 60 HEATING TIME (min) Temperature rise "t " vs applied voltage. AC 50 Hz coils. 0 10 20 30 40 50 60 HEATING TIME (min) Temperature rise "t " vs applied voltage. AC 60 Hz coils. 61 60 Series General Purpose Relays 10 A ORDERING INFORMATION Example: a 60 series P.C.B.relay, 3 CO (3PDT) with coil rated 12 V DC. 6 0 Series 4 3 No. of poles 2 = 2 CO (DPDT) 3 = 3 CO (3PDT) 0 1 2 9 Coil version 3 = DC diode in parallel to coil (positive to pin 2) 8 = AC (50/60 Hz) 9 = DC Type 4 = P.C.B. 0 0 Contact material and contact circuit 00 = Standard 20 = AgCdO 50 = AgNi + 5m Au 0 0 Options 00 = Standard Coil voltage 006 = 6V 012 = 12 V 024 = 24 V 048 = 48 V 060 = 60 V 110 = 110 V 120 = 120 V AC only 230 = 230 V AC only 240 = 240 V AC only OPTIONS 2 7 10 Coil version = 3 62 2 7 10 Option = 0030 7 10 2 Option = 0060 - 0070 7 10 2 Option = 0080 - 0090