DIN METER SERIES Yokogawa Corporation of America Contents Meter Product Line-up 2 Usage Precautions 3 Specifications 4 Scale forms and divisions 6 Standard Specifications 8 Catalog Numbers 9 DC Ammeters 10 DC Voltmeters 13 Suppressed Meters (DC Ammeters & Voltmeters) 15 AC Ammeters (Mean Rectifier Type) 16 AC Voltmeters (Mean Rectifier Type) 17 AC Ammeters (Moving Iron Type) 18 AC Voltmeters (Moving Iron Type) 20 Frequency Meters 22 Wattmeters 23 Varmeters 25 Power Factor Meters 27 Dimensions and Panel Mountings 29 Connection Diagrams 30 Meter Product Line-up 2 Model DN96 DN72 Size 96x96 72x72 9 11 13 15 16 Moving iron type 17,18,19 Differential type 20 Unbal. Bal. Bal. Unbal. Suspension type Name Ammeters DC Voltmeters Ammeters, Voltmeters, Suppressed meters Ammeters AC Voltmeters Ammeters Voltmeters Operating principle Taut band Pivot & jewel Taut band Pivot & jewel Moving coil type Taut band Pivot & jewel Taut band Pivot & jewel Taut band Pivot & jewel Pivot & jewel 1P2W 3P3W 3P4W Unbal. Feedback time division multiplier type 1P2W Varmeters 3P3W 3P4W Bal. Unbal. 1P2W Power factor meters 3P3W 3P4W Bal. Unbal. Unbal. Symbol Mean rectifier type Pivot & jewel Taut band Frequency meters Wattmeters Page Taut band Phase detection type Feedback time division multiplier type Remark: shows these meters needs external transducer. 21,22 23,24 25,26 Usage UsagePrecautions Precautions - Safety instructions for DIN meters 3 Warning Indicates usage precautions that must be read to ensure the safety of users and the equipment. 1. Usage environment & conditions Do not use YOKOGAWA DIN meters in locations such as the following: Locations where the ambient temperature is outside the range of 0-45. Locations where relative humidity is outside the range of 30-75%. Locations subject to vibrations or shock impact. Locations subject to rain, dripping water, or direct sunlight. Locations exposed to large amounts of dust, salt, soot, or corrosive gases (sulfurous acid gas, ammonia gas, hydrogen sulfide gas, or other gases that corrode metals of plastics) Locations subject to strong external noise or electromagnetic waves. Locations subject to large amounts of static electricity. Locations subject to large amounts of high frequencies and waveform distortion(e.g., from inverters or thyristor circuits) 2. Mounting method Adhere to safety rule at the construction, maintenance and inspection Check the appearance of the packing box and DIN meters and confirm that there is no damage If necessary, combine with washers and others and fasten, in the case of panel boards and switchboards are thin. Fasten nuts on clamp panel mount to the proper torque for the size of screw being used with the proper tool. Recommended tightening torque: M3 screws - 0.6N*m 3. Wiring Adhere to the following rules when connecting the wires: When connecting an instrument with accessories, first make sure none of the wires are live. The connector terminals on the wires should be appropriate for the electricity load and terminal size. Connect the wires properly as illustrated in the wiring diagrams of the catalog or on the product labels. Attach to terminal cover for safety. Fasten terminal screws to the proper torque for the size of screw being used with the proper tool. Recommended tightening torque: M3 screws - 0.6N*m M4 screws - 1.2N*m Instruments that are combined with current transformers (CT) should be properly connected to the secondary side of the CT. Improper connection may result in a CT failure, burned components, or a fire. When the secondary side of a CT is disconnected, especially while the primary side is powered, the secondary side terminal will carry a high voltage which could result in electrical shock. Therefore, the secondary side should be short-circuited before the instrument is disconnected. 4. Usage precautions Use the instrument within the rated specifications. Failure to do so can cause the equipment to malfunction or result in a failure. While the power is on, do not touch any terminals or open the cover or case. The current transformer emits heat while powered, so do not touch it. 5. What to do if the equipment functions abnormally or fails If you notice abnormal heating, or a strange odor, noises, or smoking or if the equipment seems to have failed, immediately take steps such as cutting off the input. Next, contact your YOKOGAWA sales office. 6. Maintenance and inspection To ensure that your instrument operates properly, perform the following checks on a regular basis: Check for damage to the instrument or accessories due to heating or other factors. Check for loose attachments or screws (always turn off the power before doing this to ensure safety). The instrument covers have been coated with an antistatic agent to block static electricity. Gently wipe dirt off the cover surfaces with a soft, dry cloth. Do not use a wet cloth as this will reduce the effects of the antistatic coating. Do not allow cloths made from synthetic materials to contact the cover for an extended period of time, and do not use benzene, paint thinner, or similar substances. Doing so may cause the cover to become deformed, discolor it, or cause cracking. If the indicator reading becomes unstable due to static electricity, coat the front and back of the cover with a commercially available antistatic agent. Instrument service life will vary according to usage conditions. In general, however, we recommend replacing the instrument after about 10 years of use. 7. Disposal of product Panel meters do not contain batteries. Dispose of panel meters as general industrial waste. 8. For aluminum electrolytic capacitors Frequency meters use aluminum electrolytic capacitors. The lifetime of aluminum electrolytic capacitors are around 10 years when ambient temperatures are 23. If aluminum electrolytic capacitors run down and the meters are damaged, replace new frequency meters. Specification Specifications 4 Front view(DN72 And DN96 Series Except DN96A22,23,82,83) Division Units Numerals Scale CT/VT ratio Pointer Bezel Zero adjust YOKOGAWA logo Dielectric strength Mounting position Operating principle Type Accuracy class Front view (DN96A22,23,82,83) Division Scale Units Numerals Bezel Type Operating principle Mounting position Accuracy class Pointer Dielectric strength YOKOGAWA LOGO Zero adjust 5 Back view(DN72 And DN96 Series Except DN96A22,23,82,83) Safety terminal cover The clear cover is used to prevent touching the input terminals. Don't forget to close this cover. Object: All DIN series meters. Back view(DN96A22,23,82,83) Safety terminal cover The clear cover is used to prevent touching the input terminals. Don't forget to close this cover. Object: All DIN series meters. Note:Circuit I and II are independent. Set pointer Set pointerred Easy to manage, the pointer can be set to any value. Note:The double pointer meter does not have a set pointer. Scale forms and divisions Scale Forms and Divisions 6 Scale form b) Standard scale (Except moving iron type) a) Types of division Linear scales Major line Minor line Medium line c) Moving iron type d) Suppressed meters In the case of 4-20mA current input, when value to be input is 4mA, the pointer read 0; when the value to be input is 0mA, the pointer points to the mechanical zero, Non-linear scales. Lines near "0" are omitted because of limited space and low usage. e) Extended scale (Moving iron type) Two-fold extended Three-fold extended Used in measuring the loading current of the electromotor. The Colored scales and figures with red, which are beyond the effective range. This kind is used to measure the starting current. f) Zero-center meter g) Color of scale Confirm the color is "red, green, blue or yellow". Colored line, colored field: maximum 2 piece / 2 color. Colored figure: maximum 2 piece 1color. Zero-center: the scale division is the same as the standard scale. h) Multiple-division & multiple-marking The larger scale is on external side; the smaller one is on inner side. Multiple-division is as the same as the standard scale. Single-division double-marking Double-division double-marking Colored figure Colored field Colored lined Scale division Maximum scale value Value of per division 7 Division Maximum scale value Value of per division 50 division 1 10 100 0.02 0.2 2 45 division 4.5 45 450 0.1 1 10 24 division 1.2 12 120 50 division 5 50 500 0.05 0.5 5 0.1 1 10 30 division 1.5 15 150 0.05 0.5 5 30 division 6 60 600 0.2 2 20 40 division 2 20 200 0.05 0.5 5 37.5 division 7.5 75 750 0.2 2 20 50 division 2.5 25 250 40 division 8 80 800 0.05 0.5 5 0.2 2 20 30 division 3 30 300 0.1 1 10 4 40 400 0.1 1 10 45 division 9 90 900 40 division Division 0.2 2 20 Standard Specifications Standard Specifications Item 8 DN96 Suspension type Taut band Pivot & jewel DN72 Taut band Pivot & jewel Pointer type Lance type (black color) Lance type(black color) Bezel color Black Black Front cover dimensions 96x96mm 72x72mm 53mmDN9622,23,82,83 Scale length 95mmDN96Series others The length between element center and pointer end 33.7mmDN9622,23,82,83 Full scale deflection angle 902 Meter mounting position Vertical 60.5mmDN96Series others 61mm 39mm Between electrical circuit and the case:500V DC/More than 10M Insulation resistance Between current circuit and voltage circuit:500V DC/More than 5M Linemax:500V (Ammeters only) Between electrical circuit and the case(I/V): 3320V AC for 5S; Between electrical circuit and case(FREQ., WATT,P.F.,VAR):3320 AC for 5Sbetween current circuit and case:2600V AC for 5S; Others2210V AC for 5S; Between electrical circuit I and II with double pointer meter: 3320V AC for 5S Dielectric strength Operating temperature range 045 Operating humidity range 3075%RH Storage temperature range -1050 Storage humidity range 2580%RH Case & base material ABS resinNonflammable Case material Window materialPMMAUnit electrostatic process Bezel materialABS resinNonflammable DC A1mA AC AAVE Meter weight Approx 160g Approx 160g(DN96A20,21) Approx 220g(DN96A22,23) AC A (I/V) Approx 155g WATT33W Approx 320g VAR33W Approx 320g P.F.33W Approx 320g Approx 115g Approx 115g Approx 115g Approx 115g (TRD BOX 460g) Approx 115g (TRD BOX 460g) Approx 115g (TRD BOX 460g) Approx 172g(DN96A80,81) FRQ. Approx 125g Approx 220g(DN96A82,83) Catalog Numbers Catalog Numbers 9 DNA----/ SHAPE & DIMENSION DN96 96X96 DN72 72X72 TYPE CODE 10 T/B type DC Ammeter, Voltmeters 11 P/J type DC Ammeter, Voltmeters 20 T/B type rectifying AC Ammeters, Voltmeters 21 P/J type rectifying AC Ammeters, Voltmeters 22 T/B type rectifying AC Voltmeters(Double pointer,Only DN96) 23 P/J type rectifying AC Voltmeters(Double pointer,Only DN96) 31 I/V type AC Ammeters, Voltmeters (P/J type only) 51 52 Watt Meters 1P2W Watt Meters 1P3W 54 Watt Meters 3P4W BAL 55 Watt Meters 3P3W UNBAL 56 Watt Meters 3P4W UNBAL 61 Var Meters 1P2W 63 Var Meters 3P3W BAL 64 Var Meters 3P4W BAL 65 Var Meters 3P3W UNBAL 66 Var Meters 3P4W UNBAL 71 Power Factor Meter 1P2W 73 Power Factor Meter 3P3W BAL 75 Power Factor Meter 3P3W UNBAL T/B type 76 Power Factor Meter 3P4W UNBAL 80 Frequency Meters (T/B type 81 Frequency Meters (P/J type) 82 Frequency Meters (T/B type) (Double pointer,Only DN96) 83 Frequency Meters (P/J type) (Double pointer,Only DN96) INPUT CODE N See rating input code table RATED FREQUENCY DC & rectifying AC(402kHz), I/V type AC(50/60Hz) A 50Hz Var & Power Factor B 60Hz Var & Power Factor C 400Hz I/V type AC POINTER L Spear type (black) WINDOW & BEZEL BL Clear (black) BS Set pointer (red).Double pointer meter has no set pointer. OPTIONAL INPUT CODE See rating input code table DC Ammeters DC Ammeters 10 Specify the following information from Code: Ex. DN96A10 Model - AFA - Suffix Code N Always when ordering - L - Pointer "N" BL / Cover color Optional & f t set pointer Scale and unit: Specify full scale value and unit. (Ex. 0 to 1mA) Optional feature: If necessary, specify optional feature. Product line-up Model Descriptions Dimensions Operating (Width x Height) principle Taut band Pivot & jewel DN96A10 DN96A11 96 x 96 DN72A10 DN72A11 72 x 72 Moving coil type Accuracy class 1.5 Standard descriptions Name DC Ammeters Self-contained For external shunt 1,3 Meter with VR Suffix codes Available range -ABZ -ACJ -ACY -ADR -ADX -AEA -AEG -AEM -AEU -AFA -AFD -AFG -AFN -AFX -AGN -AGZ -AHC -AHF -AHM -AHY -AJG -AJR -AJX -AKA -AKG -AKM -AKU -ALA -ALC -ALE -ALJ -ALS -AMF -AMT -AND -ANG -ANL -A01 -A04 -A05 -A07 010A 025A 050A 0100A 0150A 0200A 0300A 0500A 0750A 01mA 01.5mA 02mA 03mA 05mA 07.5mA 010mA 015mA 020mA 030mA 050mA 075mA 0100mA 0150mA 0200mA 0300mA 0500mA 0750mA 01A 01.5A 02A 03A 05A 07.5A 010A 015A 020A 030A 050mV 060mV 0100mV 075mV -A06 050mV Internal resistance, Voltage drop, Current consumption Taut band Pivot & jewel 5900 -- 3700 -- 2000 6000 484 1950 1315 3310 121 980 680 1670 40 226 132 407 10.5 42.4 33.1 66 7.2 22.4 16.4 29.6 50mV 24.8 61.5 101.5 12.5 15.3 24.3 2 Notes Suspension type is taut band 11 Standard descriptions Name DC Ammeters Zero-center meter For external shunt 1,3 Designation of frequency used Pointer type Standard type Cover type With set pointer (red) Note: Suffix codes Available range Internal resistance, Voltage drop, Current consumption Taut band Pivot & jewel -DAX 5A 5900 -- -DCJ -DCY -DDH -DDR -DDX -DED -DEM -DEU -DFA -DFD -DFK -DFX -DGN -DGZ -DHC -DHJ -DHY -DJG -DJR -DJX -DKD -DKM -DKU -DLA -DLC -DLG -DLS -DMF -DMT -DND 25A 50A 75A 100A 150A 250A 500A 750A 1mA 1.5mA 2.5mA 5mA 7.5mA 10mA 15mA 25mA 50mA 75mA 100mA 150mA 250mA 500mA 750mA 1A 1.5A 2.5A 5A 7.5A 10A 15A 2000 484 1315 121 680 40 10.5 33.1 7.2 16.4 6000 1950 3310 980 1670 226 42.4 66 22.4 29.6 -D01 50mV 101.5 -N -L -BL -BS Always "-N" Lance type (black color) Clear Clear Notes Suspension type is taut band 25mV 24.3 1 The 50mV, 60mV, 75mV, 100mV and 50mV instruments are not provided with any shunt lead. Use any lead wire of which resistance is less than 0.05 in total. External shunts are not supplied. 2 For 50mV instrument with VR, current consumption is 1mA and shunt lead's resistance compensates 2 to 0. 3 An external shunt is not supplied. Optional feature Code /003 12 Feature Notes Single-Division, Double-marking /004 Double-Divisions, Double-marking /005 Color line (Red, Green, Yellow, Blue) /006 Color band (Red, Green, Yellow, Blue) /007 Color marking (Red, Green, Yellow, Blue) /008 Meter mounting position /011 Shunt leads resistance /012 Designation of Internal Resistance /013 Class up /015 Triple set of numbers - Double set of divisions /016 Triple set of numbers - Triple set of divisions /018 Except Yokogawa standard scale divisions /022 Vibration proof /CJ Pass the attestation used in ship (IP42) Used in DN72A10,11 Used in DN72A10,DN96A10 DC Voltmeters 13 Specify the following information from Code: Ex. DN96A10 Model - VNT Suffix - when ordering N Always Code - L - Pointer BL / Cover color Optional "N" & f t set pointer Scale and unit: Specify full scale value and unit. (Ex. 0 to 50V) Optional feature: If necessary, specify optional feature. Range: For suffix V04, V05, V08, V11, specify rating. Product line-up Model Descriptions Taut band Pivot & jewel Dimensions (Width x Height) Operating principle Accuracy class DN96A10 DN96A11 96 x 96 DN72A11 72 x 72 Moving coil type 1.5 DN72A10 Standard descriptions Suffix codes Name DC Voltmeters Self-contained For external multiplier 3 Available range -VKM -VLA -VLC -VLE -VLJ -VLS -VMF -VMT -VND -VNG -VNL -VNT -VPB -VPK -VPZ -VRL -VRX -VSD -VSF -VSJ 00.5V 01V 01.5V 02V 03V 05V 07.5V 010V 015V 020V 030V 050V 075V 0100V 0150V 0200V 0300V 0450V 0500V 0600V -V01 01mA 1mA 10.5 -V05 1 V/100A V/500A -V08 Meter with VR Notes: -V11 2 0(1300)V 1 Specify from the above-mentioned rating between 0.5V and 300V. 2 20% Variable. 3 An external multiplier is not supplied 42.4 V/50A -V04 Specified loss current for direct instrument Internal resistance, Voltage drop, Current consumption Taut band Pivot & jewel V/1mA Notes Standard descriptions -EKD -EKM -EKU -ELA -ELC -ELG -ELS -EMF -EMT -END -ENJ -ENT -EPB -EPK -EPZ -ERS -ERX Zero-center meter For external multiplier Designation of frequency used Pointer type Standard type Cover type With set pointer (red) Available range Suffix codes Name DC Ammeters 14 3 Internal resistance, Voltage drop, Current consumption Taut band Pivot & jewel 0.25V 0.5V 0.75V 1V 1.5V 2.5V 5V 7.5V 10V 15V 25V 50V 75V 100V 150V 250V 300V 0.5mA -E01 1mA -N -L -BL -BS Always "-N" Lance type (black color) Clear Clear 7.2 22.4 Optional feature Code /003 Feature Notes Single-Division, Double-marking /004 Double-Divisions, Double-marking /005 Color line (Red, Green, Yellow, Blue) /006 Color band (Red, Green, Yellow, Blue) /007 Color marking (Red, Green, Yellow, Blue) /008 Meter mounting position /011 Shunt leads resistance /012 Designation of Internal Resistance /013 Class up /015 Triple set of numbers - Double set of divisions /016 Triple set of numbers - Triple set of divisions /018 Except Yokogawa standard scale divisions /022 Vibration proof /CJ Pass the attestation used in ship (IP42) Used in DN72A10,11 Used in DN72A10,DN96A10 Notes Suppressed Suppressed MetersMeters (DC Ammeters & Voltmeters) Specify following information from Code: Ex. DN96A10 - AHE - Suffix Model when ordering N - Always Code L - Pointer "N" BL / Cover color Optional & f t set pointer Scale and unit: Specify full scale value and unit. (Ex. 0 to 750) Optional feature: If necessary, specify optional feature. Product line-up Model Descriptions Taut band Pivot & jewel Dimensions (Width x Height) DN96A10 DN96A11 96 x 96 DN72A10 DN72A11 72 x 72 Operating principle Accuracy class Moving coil type 1.5 Standard descriptions Name Suppressed meters DC Ammeters DC Voltmeters Designation of frequency used Pointer type Standard type Cover type With set pointer (red) Suffix codes -AHE -AHX -A11 -A12 -A13 -VLR -N -L -BL -BS Available range Internal resistance, Voltage drop, Current consumption Taut band Pivot & jewel 3.1 3 1.2 2.4 125 -- 12.2 -- 6.2 -- 3.9 420mA 1050mA 0.21mA 15mA 210mA 15V Always "-N" Lance type (black color) Clear Clear Optional feature Code Feature /003 Single-Division, Double-marking /004 Double-Divisions, Double-marking /005 Color line (Red, Green, Yellow, Blue) /006 Color band (Red, Green, Yellow, Blue) /007 Color marking (Red, Green, Yellow, Blue) /008 Meter mounting position /010 AC symbol mark /013 Class up /015 Triple set of numbers - Double set of divisions /016 Triple set of numbers - Triple set of divisions /018 Except Yokogawa standard scale divisions /022 Vibration proof /CJ Pass the attestation used in ship (IP42) Notes Used in DN72A10,11 Used in DN72A10,DN96A10 Notes 15 AC Ammeters (Mean Rectifier Type)Type) AC Ammeters (Mean Rectifier Specify following information from Code: Ex. DN96A20 - when ordering AEA - Suffix Model 16 N - Always Code L - Pointer "N" BL / Cover color Optional & f t set pointer Scale and unit: Specify full scale value and unit. (Ex. 0 to 200A) Optional feature: If necessary, specify optional feature. CT ratio: If necessary, specify CT ratio. Product line-up Model Descriptions Taut band Pivot & jewel Dimensions (Width x Height) DN96A20 DN96A21 96 x 96 DN72A20 DN72A21 72 x 72 Operating principle Accuracy class Mean rectifier type 1.5 Standard descriptions Suffix codes Name AC Ammeters Self-contained 1 For external CT Designation of frequency used Pointer type Standard type Cover type With set pointer (red) Notes: Available range Internal resistance, Voltage drop, Current consumption Taut band Pivot & jewel 2536 3380 1286 1470 774 797 508 507 285 292 207 181 118 94 -AEA -AEM -AFA -AFG -AFX -AGZ -AHF 0200A 0500A 01mA 02mA 05mA 010mA 020mA -A40 1 207 010mA Always "-N" (40Hz to 2kHz) Lance type (black color) Clear Clear -N -L -BL -BS 181 1 An external CT is not supplied. If necessary, externally connect a CT(224800). Optional feature Code /003 Feature Notes Single-Division, Double-marking /004 Double-Divisions, Double-marking /005 Color line (Red, Green, Yellow, Blue) /006 Color band (Red, Green, Yellow, Blue) /007 Color marking (Red, Green, Yellow, Blue) /008 Meter mounting position /013 Class up /015 Triple set of numbers - Double set of divisions /016 Triple set of numbers - Triple set of divisions /018 Except Yokogawa standard scale divisions /022 Vibration proof /CJ Pass the attestation used in ship (IP42) Used in DN72A20,DN96A20 Notes AC Voltmeters (Mean Rectifier Type) Specify following information from Code: Ex. DN96A20 - VRX when ordering - Suffix Model 17 N - Always Code L - Pointer BL / Cover color "N" & Optional f t set pointer Scale and unit: Specify full scale value and unit. (Ex. 0 to 300V) Range: For suffix code V06, V08, V11, specify rating. Optional feature: If necessary, specify optional feature. CT ratio: If necessary, specify CT ratio. Product line-up Model Type Double pointer Taut band Pivot & jewel DN96A20 DN96A22 DN72A20 DN96A21 DN96A23 DN72A21 Dimensions (Width x Height) 96 x 96 72 x 72 Descriptions Operating principle Mean rectifier type Accuracy class 1.5 Standard descriptions Name AC Voltmeter Suffix codes Self-contained For external multiplier 3 For external VT Specified loss current for direct instrument Meter with VR Designation of frequency used Pointer type Standard type Cover type With set pointer (red) -VLJ -VLS -VMT -VND -VNL -VNT -VPB -VPK -VPZ -VRL -VRX -V01 -V12 -V51 -V52 -V53 -V06 -V08 -V11 -N -L -BL -BS Available range 03V 05V 010V 015V 030V 050V 075V 0100V 0150V 0200V 0300V 01mA 0150V 0275V 0289.5V 0293.3V Internal resistance Taut band Pivot & jewel 3k 2.8 k 5 k 4.7 k 9.8 k 9.6 k 15 k 14.8 k 30 k 29.8 k 48.5 k 75 101.6 k 151.6 k 201.6 k 301.6 k 774 797 k 151.6 k 271.6 k 301.6 k 1 03V, 05V,, Always "-N" (40Hz to 2kHz) Lance type (black color) Clear Clear V/200A V/500A V/1mA Optional feature Code /003 Feature Single-Division, Double-marking /004 Double-Divisions, Double-marking /005 Color line (Red, Green, Yellow, Blue) /006 Color band (Red, Green, Yellow, Blue) /007 Color marking (Red, Green, Yellow, Blue) /008 Meter mounting position /013 Class up /015 Triple set of numbers - Double set of divisions /016 Triple set of numbers - Triple set of divisions /018 Except Yokogawa standard scale divisions /022 Vibration proof /CJ Pass the attestation used in ship (IP42) Notes Used in DN72A20,DN96A20 Notes AC AC Ammeters (Moving Iron Type) Ammeters (Moving Iron Type) Specify following information from Code: Ex. DN96A31 - A42 Suffix Model Code 18 when ordering - N Always - L - Pointer BL / Cover color Optional "N" & f t set pointer Scale and unit: Specify full scale value and unit. (Ex. 0 to 300A) Optional feature: If necessary, specify optional feature. CT ratio: If necessary, specify CT ratio. (Ex. 300/5A) Product line-up Model Descriptions Pivot & jewel Dimensions (Width x Height) DN96A31 96 x 96 DN72A31 72 x 72 Operating principle Accuracy class Mean rectifier type 1.5 Standard descriptions Name AC Voltmeters Two-fold extended Three-fold extended 1 For external CT Two-fold extended 1 (For external CT ) Three-fold extended 1 (For external CT ) Suffix codes Available range Power consumption VA -AHY -AJR -AJX -AKG -AKM -ALA -ALC -ALE -ALJ -ALS -AMF -AMT -AND -ANG -ANL -A21 -A22 -A23 -A24 -A25 -A26 -A27 -A28 -A29 -A32 -A33 -A34 -A35 -A36 -A37 -A38 -A41 -A42 -A43 050mA 0100mA 0150mA 0300mA 0500mA 01A 01.5A 02A 03A 05A 07.5A 010A 015A 020A 030A 00.51A 012A 024A 036A 0510A 01020A 01530A 02040A 03060A 013A 026A 039A 0515A 01030A 01545A 02060A 01A 05A 012A -A44 0510A 0.5 -A45 013A 0.4 -A46 0515A 0.5 0.4 0.4 0.3 0.4 0.4 0.4 0.3 0.4 0.4 0.5 0.4 0.4 0.6 0.7 0.6 0.4 0.4 0.4 0.4 0.5 0.4 0.6 0.7 0.6 0.4 0.4 0.4 0.5 0.4 0.6 0.7 0.4 0.5 0.4 Notes 19 Standard descriptions Name Designation of frequency used Pointer type Cover type Note: Available range Current Suffix codes -BL -BS -N -C -L Clear Clear Notes 50/60Hz 400Hz Lance type (black color) Clear Clear 1 An external CT is not supplied. Optional feature Code /003 Feature Notes Single-Division, Double-marking /004 Double-Divisions, Double-marking /005 Color line (Red, Green, Yellow, Blue) /006 Color band (Red, Green, Yellow, Blue) /007 Color marking (Red, Green, Yellow, Blue) /008 Meter mounting position /013 Class up /015 Triple set of numbers - Double set of divisions /016 Triple set of numbers - Triple set of divisions /018 Except Yokogawa standard scale divisions /CJ Pass the attestation used in ship (IP42) Used in DN72A30 AC Voltmeters (Moving Iron Type) Specify following information from Code: Ex. DN96A30 - VRX when ordering - Suffix Model 20 N Always Code - L - Pointer "N" BL / Cover color Optional & f t set pointer Scale and unit: Specify full scale value and unit. (Ex. 0 to 300V) Optional feature: If necessary, specify optional feature. CT ratio: If necessary, specify VT ratio. Product line-up Model Descriptions Dimensions (Width x Height) 96 x 96 72 x 72 Pivot & jewel DN96A31 DN72A31 Operating principle Mean rectifier type Accuracy class 1.5 Standard descriptions Name AC Ammeters Self-contained 1 For external VT Designation of frequency used Pointer type Standard type With set pointer (red) Cover type Note: Suffix codes Available range -VMT -VND -VNG -VNL -VNT -VPB -VPK -VPZ -VRL -VRS -VRX -VSD -VSF -VSJ 010V 015V 020V 030V 050V 075V 0100V 0150V 0200V 0250V 0300V 0450V 0500V 0600V Power consumption VA 1.6 1.2 1.7 1.5 1.6 1.3 1.6 1.4 1.3 1.6 1.4 1.8 2.2 -V14 0150/ 3 V 1.5 -V12 0150V 1.4 -N -C -L -BL -BS 50/60Hz 400Hz Lance type (black color) Clear Clear 1 An external multiplier and VT are not supplied. Notes Optional feature Code /003 21 Feature Notes Single-Division, Double-marking /004 Double-Divisions, Double-marking /005 Color line (Red, Green, Yellow, Blue) /006 Color band (Red, Green, Yellow, Blue) /007 Color marking (Red, Green, Yellow, Blue) /008 Meter mounting position /013 Class up /015 Triple set of numbers - Double set of divisions /016 Triple set of numbers - Triple set of divisions /018 Except Yokogawa standard scale divisions /CJ Pass the attestation used in ship (IP42) Used in DN72A30 Frequency Meters 22 Specify following information from Code: Ex. DN96A80 - H11 - Suffix Model when ordering N - Always Code L - Pointer BL / Cover color Optional "N" & f t set pointer Optional feature: If necessary, specify optional feature. Product line-up Model Type Double pointer Descriptions Taut band Pivot & jewel DN96A80 DN96A81 DN96A82 DN96A83 DN72A80 DN72A81 Dimensions (Width x Height) Operating principle Accuracy class 96 x 96 Differential type 0.5 or 1.0 72 x 72 Standard descriptions Suffix codes Name Frequency meters Designation of frequency used Pointer type Standard type Cover With set pointer type (red) -H30 -H31 -H32 -H10 -H11 -H12 -H40 -H41 -H42 -H50 -H51 -H52 -H20 -H21 -H22 -H60 -H61 -H62 Available range 4555Hz 5565Hz 4565Hz 4555Hz 5565Hz 4565Hz 4555Hz 5565Hz 4565Hz 4555Hz 5565Hz 4565Hz 4555Hz 5565Hz 4565Hz 4555Hz 5565Hz 4565Hz 100V 110V 115V 200V 220V 230V -N 50/60Hz -L -BL Lance type (black color) Clear -BS Clear Available range 0.5 0.5 1.0 0.5 0.5 1.0 0.5 0.5 1.0 0.5 0.5 1.0 0.5 0.5 1.0 0.5 0.5 1.0 Power consumption VA Operating range 0.4 80130V 0.8 160260V Optional feature Code /005 Feature Notes Color line (Red, Green, Yellow, Blue) /006 Color band (Red, Green, Yellow, Blue) /007 Color marking (Red, Green, Yellow, Blue) /008 Meter mounting position /022 Vibration proof /CJ Pass the attestation used in ship (IP42) Used in DN72A80,DN96A80 Notes Wattmeters 23 Specify following information from Code: Ex. DN96A55 - W14 - Suffix Model when ordering N - Always Code L - Pointer BL / Cover color "N" & Optional f t set pointer Scale and unit: Specify full scale value and unit. (Ex. 0 to 120kW) Calibration watts: In case of using external CT and/of VT, calculate the possible full scale from the follow page and be sure that is within the range shown above. (Ex. 750W) Optional feature: If necessary, specify optional feature. VT ratio: If necessary, specify VT ratio. (Ex. 440/110V) Product line-up Model (Taut band) 1P2W 1P3W DN96A51 DN72A51 3P3W 3P4W DN96A52 Unbal DN96A55 Bal. DN96A54 Unbal. DN96A56 DN72A52 DN72A55 DN72A54 DN72A56 Dimensions (WidthxHeight) Operating principle Accuracy class 96x96 Feedback time division multiplier type 1.5 72x72 Transducer Self contained External box Standard descriptions Name Wattmeters Available range Suffix codes -W71 -W72 -W51 -W52 -W01 -W02 -W11 -W12 -W03 -W04 -W13 -W14 -W73 -W74 -W53 -W54 -W75 -W76 -W55 -W56 -W81 -W82 -W61 -W62 -W05 -W06 -W15 -W16 -W83 -W84 -W63 -W64 -W85 -W86 -W65 -W66 Current 0.1A 0.5A 1A 5A 0.1A 0.5A 1A 5A 0.1A 0.5A 1A 5A 0.1A 0.5A 1A 5A 0.1A 0.5A 1A 5A 0.1A 0.5A 1A 5A 0.1A 0.5A 1A 5A 0.1A 0.5A 1A 5A 0.1A 0.5A 1A 5A Voltage 100V 110/ 3 V 110V 115V 120V 200V 220V 230V 240V Notes Standard descriptions Name Suffix codes Designation of frequency used Pointer type -BL Cover type -BS -N -L Clear Clear 24 Available range Current Notes 50/60Hz Lance type (black color) Clear Clear Optional feature Code /003 Feature Notes Single-Division, Double-marking /004 Double-Divisions, Double-marking /005 Color line (Red, Green, Yellow, Blue) /006 Color band (Red, Green, Yellow, Blue) /007 Color marking (Red, Green, Yellow, Blue) /008 Meter mounting position /CJ Pass the attestation used in ship (IP42) Available standardModel calibration watts Rating Voltage Single phase 2-wire Single phase 3-wire 3-phase 3-wire 3-phase 4-wire DN96A51 DN96A52 DN96A55 DN96A54/56 DN72A51 DN72A52 DN72A55 DN72A54/56 1A 32 to 95W -- -- 95 to 285W 475 to 1400W Current 110/ 3 V 110V, 115V, 120V 220/ 3 V 200V, 220V, 240V 5A 160 to 475W -- -- 1A 55 to 164W 95 to 285W 95 to 285W 218 to 495W 5A 275 to 820W 475 to 1400W 475 to 1400W 1090 to 2475W 1A -- -- -- 250 to 570W 5A -- -- -- 1250 to 2850W 1A 110 to 328W 250 to 570W 250 to 570W 430 to 990W 5A 550 to 1640W 1250 to 2850W 1250 to 2850W 2150 to 4950W (1) When using VT and/or CT, calibration watts will be as follows; Calibration watts = MAX. Full scale value VT ratio x CT ratio Connection Full scale value VT ratio CT ratio EX.1 3-phase 3-wire 20kW 440/110V 30/5A EX.2 Single phase 2-wire 7.5kW 660/110V 20/5A Calibration watts FS= FS= 20kW 440/110x30/5 7.5kW =833.3W Available =833.3W Special order with TOKUCHU sheet 660/110x20/5 (2) Calibration watts are 65 to 150%. Standard watts beyond the limits are not available. Single phase 2-wire: Standard watts = Voltage rating x Current rating 3-phase 3-wire: Standard watts = 3 x Line voltage rating x Current rating 3-phase 4-wire: Standard watts = 3 x Phase voltage rating x Current rating Varmeters 25 Specify following information from Code: Ex. DN96A65 - M14 Suffix Model - when ordering N Always Code - L - Pointer BL / Cover color Optional "N" & f t set pointer Scale and unit: Specify full scale value and unit. (Ex. 0 to 10kvar) Calibration watts: In case of using external CT and/of VT, calculate the possible full scale from the follow page and be sure that is within the range shown above. (Ex. 416.6 var) Optional feature: If necessary, specify optional feature. VT ratio: If necessary, specify VT ratio. (Ex. 660/110V) CT ratio: If necessary, specify CT ratio. (Ex. 20/5V) Product line-up Model (Taut band) 1P2W DN96A61 DN72A61 3P3W 3P4W Bal. Unbal Bal. DN96A63 DN96A65 DN96A64 DN72A63 DN72A65 DN72A64 Unbal Self contained External box Dimensions (WidthxHeight) Operating principle Accuracy class 96x96 Feedback time division multiplier type 1.5 72x72 Transducer Self contained External box Standard descriptions Name Varmeters Available range Suffix codes -M71 -M72 -M51 -M52 -M01 -M02 -M11 -M12 -M03 -M04 -M13 -M14 -M73 -M74 -M53 -M54 -M75 -M76 -M55 -M56 -M81 -M82 -M61 -M62 -M05 -M06 -M15 -M16 -M83 -M84 -M63 -M64 -M85 -M86 -M65 -M66 Current 0.1A 0.5A 1A 5A 0.1A 0.5A 1A 5A 0.1A 0.5A 1A 5A 0.1A 0.5A 1A 5A 0.1A 0.5A 1A 5A 0.1A 0.5A 1A 5A 0.1A 0.5A 1A 5A 0.1A 0.5A 1A 5A 0.1A 0.5A 1A 5A Voltage 100V 110/ 3 V 110V 115V 120V 200V 220V 230V 240V Notes Standard descriptions Name Suffix codes -N -A -B -L Clear Clear Designation of frequency used Pointer type Cover type Standard type With set pointer (red) 26 Available range Current 50/60Hz 50Hz 60Hz Lance type (black color) Clear Clear Notes For DNA63, DNA64 For DNA61, DNA65, DNA66. Optional feature Code /003 /004 /005 /006 /007 /008 /009 /CJ Feature Single-Division, Double-marking Double-Divisions, Double-marking Color line (Red, Green, Yellow, Blue) Color band (Red, Green, Yellow, Blue) Color marking (Red, Green, Yellow, Blue) Meter mounting position Polarity change marking (LAG to LEAD) Pass the attestation used in ship (IP42) Notes Available standard calibration vars(Zero-center meter) Model Single phase 2-wire 3-phase 3-wire (Unbalanced) 3-phase 3-wire(Balanced) 3-phase 4-wire(Balanced) 3-phase 4-wire (Unbalanced) DN96A51 DN96A55 DN96A53/54 DN96A56 DN72A51 DN72A55 DN72A53/54 DN72A56 1A 21 to 95 var -- -- -- 5A 105 to 475 var -- -- -- Rating Voltage Current 110/ 3 V 110V, 115V, 120V 220/ 3 V 200V, 220V, 240V 1A 36 to 164 var 95 to 285 var 62 to 285 var 190 to 570 var 5A 180 to 820 var 475 to 1400 var 312 to 1400 var 950 to 2850 var 1A -- -- -- -- 5A -- -- -- -- 1A 72 to 328 var 190 to 570 var 125 to 570 var -- 5A 360 to 1640 var 950 to 2850 var 625 to 2850 var -- (1) When using VT and/or CT, calibration vars will be as follows; Calibration vars = MAX. Full scale value VT ratio x CT ratio Connection Full scale value VT ratio CT ratio EX.1 3-phase 3-wire (Balanced) 10kvar 660/110V 30/5A FS= EX.2 3-phase 2-wire (Unbalanced) 7.5kvar 660/110V 20/5A FS= Calibration vars 10kvar 660/110x30/5 7.5kvar =416.6 var Available =312.5 var Special order 660/110x20/5 (2) Calibration vars are 33 to 150%. Standard vars beyond the limits are not available. Single phase 2-wire: Standard vars = Voltage rating x Current rating 3-phase 3-wire: Standard vars = 3 x Line voltage rating x Current rating 3-phase 4-wire: Standard vars = 3 x Phase voltage rating x Current rating Power Factor Meters Power Fa 27 Specify following information from Code: Ex. DN96A75 - C14 Suffix Model when ordering - N - Always Code L - Pointer BL / Cover color Optional "N" & f t set pointer Optional feature: If necessary, specify optional feature. VT ratio: If necessary, specify VT ratio. (Ex. 660/110V) CT ratio: If necessary, specify CT ratio. (Ex. 20/5V) Product line-up Model (Taut band) 1P2W DN96A71 DN72A71 3P3W 3P4W Bal. Unbal Unbal. DN96A73 DN96A75 DN96A76 DN72A73 DN72A75 DN72A76 Dimensions (WidthxHeight) Self contained External box Operating principle Accuracy class Phase defection type For single-phase and 3-phase(balanced) Feedback time division multiplier type For 3-phase(unbalanced) Transducer Self contained 5.0 External box Standard descriptions Name Power factor meters Single phase 2-wire 3-phase 3-wire 3-phase 4-wire (Continued to next page) Suffix codes -C71 -C72 -C51 -C52 -C01 -C02 -C13 -C14 -C73 -C74 -C53 -C54 -C75 -C76 -C55 -C56 -C81 -C82 -C61 -C62 -C03 -C04 -C15 -C16 -C83 -C84 -C63 -C64 -C85 -C86 -C65 -C66 -C07 -C08 -C11 -C12 Available range Current Voltage 0.1A 0.5A 100V 1A 5A 0.1A 0.5A 110V 1A 5A 0.1A 0.5A 115V 1A 5A 0.1A 0.5A 120V 1A 5A 0.1A 0.5A 200V 1A 5A 0.1A 0.5A 220V 1A 5A 0.1A 0.5A 230V 1A 5A 0.1A 0.5A 240V 1A 5A 0.1A 0.5A 110/ 3 V 1A 5A Notes For: DN96A71/73/75, DN72A71/73/75 For: DN96A76, DN72A76 Standard scale: LEAD 0.50.5 LAG Standard descriptions Name Suffix codes Designation of frequency used Pointer type Cover type Standard type With set pointer (red) -N -A -B -L Clear Clear 28 Available range Current 50/60Hz 50Hz 60Hz Lance type (black color) Clear Clear Notes For DNA73, DNA74 For DNA71, DNA75, DNA76. Optional feature Code Feature /003 Single-Division, Double-marking /004 Double-Divisions, Double-marking /005 Color line (Red, Green, Yellow, Blue) /006 Color band (Red, Green, Yellow, Blue) /007 Color marking (Red, Green, Yellow, Blue) /008 Meter mounting position /009 Polarity change marking (LAG to LEAD) /CJ Pass the attestation used in ship (IP42) Notes Standard rating Rating Voltage 110/ 3 V 110V 220/ 3 V 220V Usable Current 1A 5A 1A 5A 1A 5A 1A 5A Voltage 52 to 75 V 90 to 130 V 104 to 150 V 180 to 260 V Current 0.3 to 1.2 A 1.5 to 6 A 0.3 to 1.2 A 1.5 to 6 A 0.3 to 1.2 A 1.5 to 6 A 0.3 to 1.2 A 1.5 to 6 A Dimensions and Panel Mountings 26 29 95.6 DN96A10,11 DN96A20,21, DN96A22,23 DN96A31 DN96A80,81, DN96A82,83 920.5 DN96 series 95.6 5.1 43.5 15.7 920.5 95.6 920.5 DN96A5 DN96A6 DN96A7 95.6 5.1 66.6 16.5 920.5 71.7 DN72A10,11 DN72A20,21 DN72A31 DN72A80,81 680.5 DN72 series 5.1 71.7 43.5 680.5 15.7 40 O 98 140 DN72A5 DN72A6 DN72A7 160 External transducer: O 6.5 98.5 6 Connection Diagrams 30 DC Ammeters, Voltmeters DN96A10,11 DN72A10,11 AC Ammeters, Voltmeters DN96A20,21 DN72A20,21 DN96A31 DN72A31 DN96A22,23 Wattmeters DN96A51 Single phase 2-wire DN72A51 31 DN96A55 DN72A55 3-phase 3-wire (Unbalanced) DN96A54 DN72A54 3-phase 4-wire (Balanced) DN96A56 DN72A56 3-phase 4-wire (Unbalanced) Varmeters DN96A61 Single phase 2-wire DN72A61 32 DN96A63 DN72A63 DN96A65 DN72A65 DN96A64 DN72A64 3-phase 3-wire (Balanced) 3-phase 3-wire (Unalanced) 3-phase 4-wire (Balanced) DN96A66 3-phase 4-wire (Unbalanced) DN72A66 Power factor meters DN96A71 33 DN72A71 Single phase 2-wire DN96A73 DN72A73 3-phase 3-wire (Balanced) DN96A75 DN72A75 DN96A76 DN72A76 3-phase 3-wire (Unbalanced) 3-phase 4-wire (Unbalanced) Frequency meters DN96A80,81 DN72A80,81 DN96A82,83 34 E-mail: meters-instr@us.yokogawa.com 2 Dart Road Newnan, Georgia 30265 Phone: 800-888-6400 Represented by: