Notes:
(1) Tested with pulses tp=20ms.
(2) Valid provided that leads are kept at ambient temperature at a distance of 8 mm from case.
Type
Zener voltage range 1) Dynamic resistance Reverse leakage
current
Temp. coefficient
of Zener voltage
Vznom IZT for VZT 2) rzjT and rzjk at IZK IR 2) at VRTKVZ
VmA V mA uA V %/K
BZV 85/C 2V7 2.7 80 2.5 ... 2.9 <20 <400 1 <150 1 -0.08 ... -0.05
BZV 85/C 3V0 3.0 80 2.8 ... 3.2 <20 <400 1 <100 1 -0.08 ... -0.05
BZV 85/C 3V3 3.3 70 3.1 ... 3.5 <20 <400 1 <40 1 -0.08 ... -0.05
BZV 85/C 3V6 3.6 60 3.4 ... 3.8 <15 <500 1 <20 1 -0.08 ... -0.05
BZV 85/C 3V9 3.9 60 3.7 ... 4.1 <15 <500 1 <10 1 -0.07 ... -0.02
BZV 85/C 4V3 4.3 50 4.0 ... 4.6 <13 <500 1 <3 1 -0.07 ... +0.01
BZV 85/C 4V7 4.7 45 4.4 ... 5.0 <13 <600 1 <3 1 -0.03 ... +0.04
BZV 85/C 5V1 5.1 45 4.8 ... 5.4 <10 <500 1 <1 1.5 -0.01 ... +0.04
BZV 85/C 5V6 5.6 45 5.2 ... 6.0 <7 <400 1 <1 2 0 ... +0.045
BZV 85/C 6V2 6.2 35 5.8 ... 6.6 <4 <300 1 <1 3 +0.01 ... +0.055
BZV 85/C 6V8 6.8 35 6.4 ... 7.2 <3.5 <300 1 <1 4 +0.015 ... +0.06
BZV 85/C 7V5 7.5 35 7.0 ... 7.9 <3 <200 0.5 <1 4.5 +0.02 ... +0.065
BZV 85/C 8V2 8.2 25 7.7 ... 8.7 <5 <200 0.5 <1 6.2 0.03 ... 0.07
BZV 85/C 9V1 9.1 25 8.5 ... 9.6 <5 <200 0.5 <1 6.8 0.035 ... 0.075
BZV 85/C 10 10 25 9.4 ... 10.6 <7 <200 0.5 <0.5 7 0.04 ... 0.08
BZV 85/C 11 11 20 10.4 ... 11.6 <8 <300 0.5 <0.5 8.2 0.045 ... 0.08
BZV 85/C 12 12 20 11.4 ... 12.7 <9 <350 0.5 <0.5 9.1 0.045 ... 0.085
BZV 85/C 13 13 20 12.4 ... 14.1 <10 <400 0.5 <0.5 10 0.05 ... 0.085
BZV 85/C 15 15 15 13.8 ... 15.6 <15 <500 0.5 <0.5 11 0.055 ... 0.09
BZV 85/C 16 16 15 15.3 ... 17.1 <15 <500 0.5 <0.5 12 0.055 ... 0.09
BZV 85/C 18 18 15 16.8 ... 19.1 <20 <500 0.5 <0.5 13 0.06 ... 0.09
BZV 85/C 20 20 10 18.8 ... 21.2 <24 <600 0.5 <0.5 15 0.06 ... 0.09
BZV 85/C 22 22 10 20.8 ... 23.3 <25 <600 0.5 <0.5 16 0.06 ... 0.095
BZV 85/C 24 24 10 22.8 ... 25.6 <25 <600 0.5 <0.5 18 0.06 ... 0.095
BZV 85/C 27 27 8 25.1 ... 28.9 <30 <750 0.25 <0.5 20 0.06 ... 0.095
BZV 85/C 30 30 8 28 ... 32 <30 <1000 0.25 <0.5 22 0.06 ... 0.095
BZV 85/C 33 33 8 31 ... 35 <35 <1000 0.25 <0.5 24 0.06 ... 0.095
BZV 85/C 36 36 8 34 ... 38 <40 <1000 0.25 <0.5 27 0.06 ... 0.095
BZV 85/C 39 39 6 37 ... 41 <50 <1000 0.25 <0.5 30 0.06 ... 0.095
BZV 85/C 43 43 6 40 ... 46 <50 <1000 0.25 <0.5 33 0.06 ... 0.095
BZV 85/C 47 47 4 44 ... 50 <90 <1500 0.25 <0.5 36 0.06 ... 0.095
BZV 85/C 51 51 4 48 ... 54 <115 <1500 0.25 <0.5 39 0.06 ... 0.095
BZV 85/C 56 56 4 52 ... 60 <120 <2000 0.25 <0.5 43 0.06 ... 0.095
BZV 85/C 62 62 4 58 ... 66 <125 <2000 0.25 <0.5 47 0.06 ... 0.095
BZV 85/C 68 68 4 64 ... 72 <130 <2000 0.25 <0.5 51 0.06 ... 0.095
BZV 85/C 75 75 4 70 ... 79 <135 <2000 0.25 <0.5 56 0.06 ... 0.095
BZV 85/C 82 82 2.7 77 ... 87 <200 <3000 0.25 <0.5 62 0.07 ... 0.10
BZV 85/C 91 91 2.7 85 ... 96 <250 <3000 0.25 <0.5 68 0.07 ... 0.10
BZV 85/C 100 100 2.7 94 ... 106 <350 <3000 0.25 <0.5 75 0.07 ... 0.11
BZV 85/C 110 110 2.7 104 ... 116 <450 <4000 0.25 <0.5 82 0.07 ... 0.11
BZV 85/C 120 120 2 114 ... 127 <550 <4500 0.25 <0.5 91 0.07 ... 0.11
BZV 85/C 130 130 2 124 ... 141 <700 <5000 0.25 <0.5 100 0.07 ... 0.11
BZV 85/C 150 150 2 138 ... 156 <1000 <6000 0.25 <0.5 110 0.07 ... 0.11
BZV 85/C 160 160 1.5 153 ... 171 <1100 <6500 0.25 <0.5 120 0.07 ... 0.11
BZV 85/C 180 180 1.5 168 ... 191 <1200 <7000 0.25 <0.5 130 0.07 ... 0.11
BZV 85/C 200 200 1.5 188 ... 212 <1500 <8000 0.25 <0.5 150 0.07 ... 0.11
2