1433 FIBER SENSORS * Refer to our website for details of product. Compact Size Horizontal Type HL RoHS compliance (AZH) Micro Limit Switch Related Information *1 General terms and conditions.............. F-3 LASER SENSORS *1 AZH10 only Features PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS * Superior environmental resistance (Die casting case type) * Standardized connector type * Lineup includes bifurcated (twin contact) type as well as standard load type * Economical plastic case type AREA SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS panasonic.net/id/pidsx/global SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES Compact, high-performance limit switch with superior environmental resistance PRODUCT TYPE Body ENERGY MANAGEMENT SOLUTIONS Type FA COMPONENTS Die casting case Screw terminal type Standard Bifurcated Connector type Bifurcated Plastic case Screw terminal type Standard Bifurcated MACHINE VISION SYSTEMS UV CURING SYSTEMS Timers Time Switches Counters Hour Meters Options Limit Switches Temperature Controllers Solenoids Fan Motors Selection Guide SL HL QL Magnelimit Actuator Model No. Model No. Model No. Model No. Model No. Push plunger Common to panel mount push plunger AZH1001 AZH1201 Roller plunger Common to panel mount roller plunger AZH1002 AZH1202 Common to panel mount cross roller plunger AZH1003 AZH1203 Panel mount push plunger AZH2031 AZH2231 AZH2331 AZH1031 AZH1231 Panel mount roller plunger AZH2032 AZH2232 AZH2332 AZH1032 AZH1232 Panel mount cross roller plunger AZH2033 AZH2233 AZH2333 AZH1033 AZH1233 Sealed push plunger AZH2011 AZH2211 AZH2311 AZH1011 AZH1211 Sealed roller plunger AZH2012 AZH2212 AZH2312 AZH1012 AZH1212 Sealed cross roller plunger AZH2013 AZH2213 AZH2313 AZH1013 AZH1213 Short roller lever AZH2041 AZH2241 AZH2341 AZH1041 AZH1241 Roller lever AZH2021 AZH2221 AZH2321 AZH1021 AZH1221 One-way short roller lever AZH2044 AZH2244 AZH2344 AZH1044 AZH1244 One-way roller lever AZH2024 AZH2224 AZH2324 AZH1024 AZH1224 Flexible AZH1066 AZH1266 Cross roller plunger HL (AZH) Micro Limit Switch 1434 Options FIBER SENSORS Specifications Product Pin arrangement Cable connector cord AC Type Straight Angle Core No. Color of wire Conductor Length of cable 4 Brown, White, Blue, Black 0.5 mm2 0.75 x 10-3 in2 (Circumference: o6.5 o0.256 approx.) 3m 9.843 ft Application All connector type Model No. LASER SENSORS AZH28113 PHOTOELECTRIC SENSORS AZH28133 CAUTIONS AREA SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS Common for all types * This limit switch is designed under the premise that it will be used in a standard industrial device. Accordingly, there are limits as to what can be tolerated if used outdoors or where water and oil, etc., may get on the device. The following table indicates how much water and oil can be withstood (classification of protective structure). Plastic case (AZH1*) Protective classification Testing method Limits on use MICRO PHOTOELECTRIC SENSORS Die casting case (AZH2*) IP64 IP67 No harmful effect when sprayed with water for 10 minutes from all angles. Water does not enter product after immersion in water 1 m 3.281 ft deep for 30 minutes. Cannot be used outdoors or in a place where water and oil, etc., will continually contact the device. Cannot be used outdoors where it can be rained on directly and cannot be used submersed in water or in oil, etc. Note: Although, initially, the protective classification complies under the testing above, due consideration must be taken because great differences may result depending on factors such as duration of operation, installation method, and environment. * The internal mechanism will break if the actuator is moved beyond its Total-travel (T.T.). Always use within the T.T. Die casting case * Do not expose HL limit switch to hot water (over 60 C +140 F) and in a water vapor environment. * Avoid the place where organic solvents, strong acid, strong alkali liquid and vapor may attach to the products directly. Prevent using the HL limit switch in place where inflammable or corrosive gas will be generated. * Do not change the operating position by bending the actuator. * Use within an ambient temperature of -10 to 80 C. +14 to +176 F (However, do not allow it to freeze.) * If O.T. is too big, the life of limit switch will be shortened by switching friction. Use it with enough margin of O.T. 70 % of O.T. standard value will be good. * Attach the terminal cover securely to the body with the metal stop latch to the projection of the body. * Confirmation test in the actual application is highly recommended. * Do not use the switch in a silicon atmosphere. Care should be taken where organic silicon rubber, adhesive, seling material, oil, grease or lead wire generates silicon. * This is designed to use inside. When used outdoors (in places where there is exposure to direct sunlight or rain such as in multistory car parks) or in environments where ozone is generated, the influence of these environments cause deterioration of the rubber material and damage for the products. * Avoid use in excessively dusty environments where actuator operation would be hindered. Plastic case * Do not use in water or oil. Do not place the switch where it is always exposed to water or dust splash. * Do not expose HL limit switch to hot water (over 60 C +140 F) and in a water vapor environment. * Avoid the place where organic solvents, strong acid, strong alkali liquid and vapor may attach to the products directly. Prevent using the HL limit switch is place where inflammable or corrosive gas will be generated. * Do not change the operating position by bending the actuator. * Use within an ambient temperature of -10 to 80 C. +14 to +176 F (However, do not allow it to freeze.) * If O.T. is too big, the life of limit switch will be shortened switching friction. Use it with enough margin of O.T. 70 % of O.T. standard value will be good for use. * Attach the terminal cover securely to the body to the extent you can identify the clicking or locking sound. * A confirmation test in the actual application is highly recommended. * Do not use the switch in a silicon atmosphere. Case should be taken where organic silicon rubber, adhesive, sealing material, oil, grease or lead wire generates silicon. * This is designed to use inside. When used outdoors (in places where there is exposure to direct sunlight or rain such as in multistory car parks) or in environments where ozone is generated, the influence of these environments cause deterioration of the rubber material and damage for the products. * Avoid use in excessively dusty environments where actuator operation would be hindered. PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Timers Time Switches Counters Hour Meters Options Limit Switches Temperature Controllers Solenoids Fan Motors Selection Guide SL HL QL Magnelimit