1433
Related Information
Compact Size Horizontal Type
HL (AZH) Micro Limit Switch
PRODUCT TYPE
Body
Type Die casting case Plastic case
Screw terminal type Connector type Screw terminal type
Standard Bifurcated Bifurcated Standard Bifurcated
Actuator Model No. Model No. Model No. Model No. Model No.
Push plunger Common to panel mount push plunger AZH1001 AZH1201
Roller plunger Common to panel mount roller plunger AZH1002 AZH1202
Cross roller plunger Common to panel mount cross roller plunger AZH1003 AZH1203
Panel mount push plunger AZH2031 AZH2231 AZH2331 AZH1031 AZH1231
Panel mount roller plunger AZH2032 AZH2232 AZH2332 AZH1032 AZH1232
Panel mount cross roller plunger AZH2033 AZH2233 AZH2333 AZH1033 AZH1233
Sealed push plunger AZH2011 AZH2211 AZH2311 AZH1011 AZH1211
Sealed roller plunger AZH2012 AZH2212 AZH2312 AZH1012 AZH1212
Sealed cross roller plunger AZH2013 AZH2213 AZH2313 AZH1013 AZH1213
Short roller lever AZH2041 AZH2241 AZH2341 AZH1041 AZH1241
Roller lever AZH2021 AZH2221 AZH2321 AZH1021 AZH1221
One-way short roller lever AZH2044 AZH2244 AZH2344 AZH1044 AZH1244
One-way roller lever AZH2024 AZH2224 AZH2324 AZH1024 AZH1224
Flexible
―――
AZH1066 AZH1266
RoHS compliance
*1
* Refer to our website for details of product.
General terms and conditions ............. F-3
Compact, high-performance limit switch
with superior environmental resistance
Features
Superior environmental resistance
(Die casting case type)
Standardized connector type
Lineup includes bifurcated (twin
contact) type as well as standard load
type
Economical plastic case type
panasonic.net/id/pidsx/global
*1 AZH10 only
FIBER
SENSORS
LASER
SENSORS
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
SAFETY LIGHT
CURTAINS /
SAFETY COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC
CONTROL
DEVICES
LASER
MARKERS
PLC
HUMAN MACHINE
INTERFACES
ENERGY
MANAGEMENT
SOLUTIONS
FA COMPONENTS
MACHINE VISION
SYSTEMS
UV CURING
SYSTEMS
Timers
Time Switches
Counters
Hour Meters
Options
Limit Switches
Temperature
Controllers
Solenoids
Fan Motors
Selection
Guide
SL
HL
QL
Magnelimit
1434
HL (AZH) Micro Limit Switch
Product Specications Application Model No.
Pin arrangement
Type Core No. Color of wire Conductor
Length of cable
Cable connector cord AC
Straight
4Brown, White,
Blue, Black
0.5 mm
2
0.75 × 10
-3
in
2
(Circumference:
ø6.5 ø0.256 approx.)
3 m
9.843 ft All connector type
AZH28113
Angle AZH28133
Options
CAUTIONS
Common for all types
• This limit switch is designed under the premise that it will be used in a standard industrial device. Accordingly, there are
limits as to what can be tolerated if used outdoors or where water and oil, etc., may get on the device.
The following table indicates how much water and oil can be withstood (classication of protective structure).
Plastic case (AZH1*) Die casting case (AZH2*)
Protective
classication IP64 IP67
Testing method No harmful effect when sprayed with water for 10 minutes from all
angles.
Water does not enter product after immersion in water 1 m 3.281 ft
deep for 30 minutes.
Limits on use Cannot be used outdoors or in a place where water and oil, etc., will
continually contact the device.
Cannot be used outdoors where it can be rained on directly and
cannot be used submersed in water or in oil, etc.
Note: Although, initially, the protective classication complies under the testing above, due consideration must be taken because great differences may
result depending on factors such as duration of operation, installation method, and environment.
The internal mechanism will break if the actuator is moved beyond its Total-travel (T.T.). Always use within the T.T.
Die casting case
• Do not expose HL limit switch to hot water (over 60 °C
+140 °F) and in a water vapor environment.
• Avoid the place where organic solvents, strong acid,
strong alkali liquid and vapor may attach to the products
directly. Prevent using the HL limit switch in place where
inammable or corrosive gas will be generated.
• Do not change the operating position by bending the
actuator.
• Use within an ambient temperature of –10 to 80 °C. +14
to +176 °F (However, do not allow it to freeze.)
• If O.T. is too big, the life of limit switch will be shortened
by switching friction.
Use it with enough margin of O.T. 70 % of O.T. standard
value will be good.
• Attach the terminal cover securely to the body with the
metal stop latch to the projection of the body.
Conrmation test in the actual application is highly
recommended.
• Do not use the switch in a silicon atmosphere. Care
should be taken where organic silicon rubber, adhesive,
seling material, oil, grease or lead wire generates silicon.
• This is designed to use inside. When used outdoors (in
places where there is exposure to direct sunlight or rain
such as in multistory car parks) or in environments where
ozone is generated, the inuence of these environments
cause deterioration of the rubber material and damage
for the products.
• Avoid use in excessively dusty environments where
actuator operation would be hindered.
Plastic case
• Do not use in water or oil.
Do not place the switch where it is always exposed to
water or dust splash.
• Do not expose HL limit switch to hot water (over 60 °C
+140 °F) and in a water vapor environment.
• Avoid the place where organic solvents, strong acid,
strong alkali liquid and vapor may attach to the products
directly. Prevent using the HL limit switch is place where
inammable or corrosive gas will be generated.
• Do not change the operating position by bending the
actuator.
• Use within an ambient temperature of –10 to 80 °C. +14
to +176 °F (However, do not allow it to freeze.)
• If O.T. is too big, the life of limit switch will be shortened
switching friction. Use it with enough margin of O.T. 70 %
of O.T. standard value will be good for use.
• Attach the terminal cover securely to the body to the
extent you can identify the clicking or locking sound.
A conrmation test in the actual application is highly
recommended.
• Do not use the switch in a silicon atmosphere. Case
should be taken where organic silicon rubber, adhesive,
sealing material, oil, grease or lead wire generates
silicon.
• This is designed to use inside. When used outdoors (in
places where there is exposure to direct sunlight or rain
such as in multistory car parks) or in environments where
ozone is generated, the inuence of these environments
cause deterioration of the rubber material and damage
for the products.
• Avoid use in excessively dusty environments
where actuator operation would be hindered.
FIBER
SENSORS
LASER
SENSORS
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
SAFETY LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
STATIC
CONTROL
DEVICES
LASER
MARKERS
PLC
HUMAN
MACHINE
INTERFACES
ENERGY
MANAGEMENT
SOLUTIONS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Timers
Time
Switches
Counters
Hour
Meters
Options
Limit
Switches
Temperature
Controllers
Solenoids
Fan
Motors
Selection
Guide
SL
HL
QL
Magnelimit