EF12 Power entry modules with line filter www.schurter.com/pg06 Inlet filter, front side mounting, deeply placed circuit breaker TA45 2-pole Standard- or Medical-Filter C20 70 C Description Characteristics Approvals References - Panel Mount: Screw-on from front side - 3 Functions: Inlet Protection class I, circuit breaker type TA45 2-pole, Line filter in standard and medical version - Quick connect terminals 6.3 x 0.8 mm - Alternative: version without line filter EF11 - All single elements are already wired - Line switch non-illuminated Illuminated version on request Thermal overload protection Optional with undervoltage release or remote trip release - With EMC-shield - Qualified for use in equipment according IEC/EN 60950 General Product Information - VDE License Number: 40001520 - UL License Number: E72928 Weblinks Approvals: www.schurter.com/approvals RoHS: http://www.schurter.com/rohs CHINA-RoHS: www.schurter.com/china-rohs Webstore: www.schurterinc.com/estore/search.ihtml Technical Data Ratings IEC Ratings UL/CSA Leakage Current Dielectric Strength Allowable Operation Temp. Climatic Category Degree of Protection Protection Class Terminal Panel Thickness s Material: Housing 12 - 16 A @ Ta 40 C / 250 VAC; Hz 50 12 - 20 A @ Ta 40 C / 125 VAC; 60 Hz standard < 0.5 mA (250 V / 60 Hz) medical < 5 A (250 V / 60 Hz) > 1.7 kVDC between L-N > 2.7 kVDC between L/N-PE Test voltage (2 sec) -10 C to 55 C 10/055/21 acc. to IEC 60068-1 from front side IP 40 acc. to IEC 60529 Suitable for appliances with protection class I acc. to IEC 61140 Quick connect terminals 6.3 x 0.8 mm Screw-on: max 8 mm Mounting screw torque max 0.5 Nm Thermoplastic, black, UL 94V-0 Appliance-Inlet /-Outlet Circuit breaker Line Switch Line Filter MTBF Connectors C20 acc. to IEC/EN 60320-1, UL 498, CSA C22.2 no. 42 (for cold condition) pin-temperature 70 C, 16 A, Protection class I Acc. IEC/EN 60934, UL 1077, CSA 22.2 no. 235 2-pole rocker switch, illuminated or nonilluminated. Optional with undervoltageor remote trip release Short circuit capacity Icn: at In < 3A/240VAC : 10 x In at In 3A/240VAC : 300A Rocker switch 2-pole, non-illuminated or illuminated, acc. to IEC 61058-1 Technical details Standard and Medical Version, IEC 60939, IEC 606011, UL 1283, UL 544, EN 133 200, CSA C22.2 no. 8 Technical details > 100'000 h acc. to MIL-HB-217 F EF12 Power entry modules with line filter www.schurter.com/pg06 Dimensions Length 59.5 mm 37 2.8 76.2* 10.6 32.2 41.2 32.9 3.6 0.8 R 810.10 90 0.10 80.05 .5 R6 S 3.3 9.5 6.4 59.5 33.9 0.10 4.55 0.05 12.55 40.55 10.9 4. 7 R 5.5 79.2 12.2 40.55 90 101 R 3. 55 0 .0 5 05 3. R 2.8 5.3 * --- Version TA45 with undervoltage release Technical Data of Filter-Components Rated Current [A] Filter-Type Inductances L [mH] Capacitance CX [nF] Capacitance CY [nF] R [MW] 12 Standard Version 2 x 0.8 100 2.2 1 16 Standard Version 2 x 0.6 100 2.2 1 20 Standard Version 2 x 0.3 100 2.2 1 12 Medical Version (M5) 2 x 0.8 100 - 1 16 Medical Version (M5) 2 x 0.6 100 - 1 20 Medical Version (M5) 2 x 0.3 100 - 1 Diagrams Standard version Medical version 1) Line 2) Load 1) Line 2) Load Attenuation Loss Standard version 12 A - - - - differential mode _____ common mode 16 A 20 A Connectors EF12 Power entry modules with line filter www.schurter.com/pg06 Medical version (M5) 12 A Packaging unit 16 A 20 A 16 Pcs Accessory Description Assorted Covers Rear Cover Cord retaining kits Cord retainning strain reliefe Connectors EF12 Power entry modules with line filter www.schurter.com/pg06 />Li -iiVI vA Ii /{x "AiA iY>i I * / 7 U i AUIV U Oi] AViA >VIO>Ii U +OV ViVI IiA> "I iA IiA AiOiAI x > >}A> / iA> UiA> AIiVI UI OI 7I OI O>I 7I O>I OOaoO{a 6 aoOa 6 UI i *O * *O E x E UI Oi * *O * I { I / aO a{ O { IO I{ P OAA -UIV vAI 7 ,ViA L>V L>V L>V E U Ii L>V q q q A>}i IA>A ,ViA i}i OAIA>I OA v AI AIi " AIi -OAv>Vi " AIi " " OA v AI L>V U Ii * AIi " U Ii L>V , AIi " L>V U Ii " AIi " " iLAAi OAIA>I -OAv>Vi *AI v I i AViA i}i i} ,>Ii VOAAiI\ U 7I OI I iA> UiA> AIiVI\ Vi aa P r Oa U 7I I iA> UiA> AIiVI\ A>Ii VOAAiI (R) a]a ]a O]a i aa a Oa I]a {]a x]a i E]a C]a n]a Ia {a xa "I iA A>Ii VOAAiIA AiOiAI 7I OI Aii>Ai\ Vi a 1iAUI>}i Aii>Ai *O * 1 *O ,iIi IA Aii>Ai L 1 1 * *O L> * *O V * 1 < i ,>Ii UI>}i 1 U U U U O O{a 6 U U U U I OIa 6 U U U U { Oa 6 Connectors i Ea Ca na ]a Oa]a i a Oaa xa a EF12 Power entry modules with line filter www.schurter.com/pg06 Technical data (continued) Circuit breaker Tripping characteristics In < 3 A [ min ] [ sec ] 10'000 60 Type TA45 Rated current In <3 A [ min ] [ sec ] 10'000 60 1 pole protected 2000 30 20 500 TA4 5 Rated current In 3 A... < 18 A 0 1 pole protected 0 2 pole protected 20 +23 C Ambient temp. min ] [ sec ] 10'000 Type 2000 30 2 pole protected 1000 10 Tripping characteristics In * 18 A Tripping characteristics In * 3... < 18 A 0 1000 10 +23 C Ambient temp. 500 0 5 5 200 100 100 1 1 pole protected 2 pole protected 1000 50 20 10 10 10 5 5 5 2 2 2 1 1 1 0,5 0,5 0,5 0,1 1,05 1,32 2 3 4 5 8 Multiple of rated current 0,3 0,2 0,1 1,05 1,32 10 [ x In ] +23 C 100 1 20 0,2 Ambient temp. 500 20 0,3 In 18 A 2000 200 50 Tripping time Tripping time 50 TA4 5 Rated current 5 200 Tripping time 1 Type 2 3 4 5 10 [ x In ] Multiple of rated current 1) Effect of ambient temperature The unit is calibrated for an ambient temperature of +23 C. To determine the rated current for a lower or higher ambient temperature, use a correction factor from the table on the right side: 8 0,3 0,2 0,1 1,05 1,32 2 3 Multiple of rated current 4 5 8 10 [ x In ] * Temperature must be measured at the rear of the breaker next to the terminals after equipment operating temperature has been reached. Example Rated current at +23 C Ambient temperature Correction factor Chosen rated current at +40 C ambient temperature 1) * Ambient temperature [C] -10 -5 0 +23 +30 +40 +55 Correction factor 0,89 0,91 0,92 1,00 1,03 1,08 1,16 6,0 A +40 C 1,08 6 A x 1,08 = 6,5 A Order code for EF12 (order example) Type EF12. Please note that Schurter will establish an internal new part number for logistical use in addition to the order code. The format of this internal part number is, for example EF12.xxxx.1110.01 Order code TA45 (2-pole rocker-switch without accessories) A B T W F 1 5 0 C 0 . Application note The rated current of the line filter must be equal or higher than the rated current of the circuit-breaker 11 1 0. 0 1 Other versions on request - Rocker switch illuminated see table 1 Wiring 1 = wired Protection class 0 = Class I, housing black Panel mount 0 = Screw-on version Terminals 1 = Quick connect terminals 6,3 x 0,8 mm Line filter version 1 = standard 2 = medical Line filter, rated current 1 = 20 A, 2 = 16 A, 3 = 12 A The specifications, descriptions and illustrations indicated in this document are based on Connectors current information. All content is subject to modifications anamendments.