E Prepared (also subject responsible if other) SEC/D Kevin Zhou Approved (also subject responsible if other) Prepared PKM 4000C PINB Series SEC/D Kevin Zhou EFEIDEN Checked MICOSPE Public PRODUCT SPECIFICATION No. Public 1/1301-BMR63701 TABLE OF CONTENTS Technical Specification Date No. Rev Reference 1 (3) 1 (1) EN/LZT 146 307 R4A August 2008 2007-1-29 F 307 Uen 001 52- EN/LZT 146 DC/DC converters, Input 36-75 V, Output 55 A/204 W (c) Ericsson Power Modules AB Key Features * Industry standard quarter-brick and optional double Pin-Out. 57.9 x 36.8 x 9.1 mm (2.28 x 1.45 x 0.35 in.) * High efficiency, typ. 94 % at 12 Vout half load * 2250 Vdc input to output isolation * Meets isolation requirements equivalent to basic insulation according to IEC/EN/UL 60950 * More than 2.7 million hours MTBF General Characteristics * * * * * * * Over temperature protection Over current limit protection Over voltage protection Remote control Output voltage adjust function Highly automated manufacturing ensures quality ISO 9001/14001 certified supplier Safety Approvals Design for Environment Meets requirements in hightemperature lead-free soldering processes. Contents General Information Safety Specification Absolute Maximum Ratings ............................................................. 2 ............................................................. 3 ............................................................. 4 Product Program 2.5V, 55A / 137.5W Electrical Specification 3.3V, 50A / 165W Electrical Specification 5.0V, 40A / 200W Electrical Specification 12.0V, 17A / 204W Electrical Specification Ordering No. PKM4119C PINB .................................. 5 PKM4110C PINB .................................. 8 PKM4211C PINB ................................ 11 PKM4213C PINBSP ........................... 14 EMC Specification Operating Information Thermal Consideration Connections Mechanical Information Soldering Information Delivery Information Product Qualification Specification ........................................................... 17 ........................................................... 18 ........................................................... 20 ........................................................... 20 ........................................................... 21 ........................................................... 25 ........................................................... 25 ........................................................... 26 Public PRODUCT SPECIFICATION E Prepared (also subject responsible if other) SEC/D Kevin Zhou Approved PKM 4000C PINB Series SEC/D Kevin Zhou 1/1301-BMR63701 Technical Specification Checked Date Rev MICOSPE 2007-1-29 DC/DC converters, Input 36-75 V, Output 55 A/204 W General Information - Ordering Information - See Contents for individual product ordering numbers. Option Baseplate Single Pin* Positive Remote Control Logic Increased stand-off height Lead length 3.69 mm (0.145 in) Lead length 4.57 mm (0.180 in) 2 (3) No. Suffix SP P M LA LB Ordering No. PKM 4110C PI PKM 4211C PINBSP PKM 4110C PIPNB PKM 4110C PINBM PKM 4110C PINBLA PKM 4110C PINBLB Note: As an example a positive logic, increased standoff, short pin product would be PKM 4110C PIPNBMLA. *Single Pin option only for current less than 50A. Reliability The Mean Time Between Failure (MTBF) is calculated at full output power and an operating ambient temperature (TA) of +40C, which is a typical condition in Information and Communication Technology (ICT) equipment. Different methods could be used to calculate the predicted MTBF and failure rate which may give different results. Ericsson Power Modules currently uses two different methods, Ericsson failure rate data system DependTool and Telcordia SR332. Predicted MTBF for the series is: 2.7 million hours according to DependTool. 1.4 million hours according to Telcordia SR332, issue 1, Black box technique. The Ericsson failure rate data system is based on field tracking data. The data corresponds to actual failure rates of components used in ICT equipment in temperature controlled environments (TA = -5...+65C). Telcordia SR332 is a commonly used standard method intended for reliability calculations in ICT equipment. The parts count procedure used in this method was originally modelled on the methods from MIL-HDBK-217F, Reliability Predictions of Electronic Equipment. It assumes that no reliability data is available on the actual units and devices for which the predictions are to be made, i.e. all predictions are based on generic reliability parameters. Compatibility with RoHS requirements The products are compatible with the relevant clauses and requirements of the RoHS directive 2002/95/EC and have a maximum concentration value of 0.1% by weight in homogeneous materials for lead, mercury, hexavalent chromium, PBB and PBDE and of 0.01% by weight in homogeneous materials for cadmium. Exemptions in the RoHS directive utilized in Ericsson Power Modules products include: Lead in high melting temperature type solder (used to solder the die in semiconductor packages) 2 Reference EN/LZT 146 307 R4A August 2008 F (c) Ericsson Power Modules AB Lead in glass of electronics components and in electronic ceramic parts (e.g. fill material in chip resistors) Lead as an alloying element in copper alloy containing up to 4% lead by weight (used in connection pins made of Brass) Quality Statement The products are designed and manufactured in an industrial environment where quality systems and methods like ISO 9000, 6 (sigma), and SPC are intensively in use to boost the continuous improvements strategy. Infant mortality or early failures in the products are screened out and they are subjected to an ATE-based final test. Conservative design rules, design reviews and product qualifications, plus the high competence of an engaged work force, contribute to the high quality of our products. Warranty Warranty period and conditions are defined in Ericsson Power Modules General Terms and Conditions of Sale. Limitation of Liability Ericsson power Modules does not make any other warranties, expressed or implied including any warranty of merchantability or fitness for a particular purpose (including, but not limited to, use in life support applications, where malfunctions of product can cause injury to a person's health or life). Public PRODUCT SPECIFICATION E Prepared (also subject responsible if other) SEC/D Kevin Zhou Approved PKM 4000C PINB Series SEC/D Kevin Zhou 3 (3) No. 1/1301-BMR63701 Technical Specification Checked Date Rev MICOSPE 2007-1-29 DC/DC converters, Input 36-75 V, Output 55 A/204 W 3 Reference EN/LZT 146 307 R4A August 2008 F (c) Ericsson Power Modules AB Safety Specification General information Ericsson Power Modules DC/DC converters and DC/DC regulators are designed in accordance with safety standards IEC/EN/UL60950, Safety of Information Technology Equipment. IEC/EN/UL60950 contains requirements to prevent injury or damage due to the following hazards: * * * * * * Electrical shock Energy hazards Fire Mechanical and heat hazards Radiation hazards Chemical hazards On-board DC-DC converters are defined as component power supplies. As components they cannot fully comply with the provisions of any Safety requirements without "Conditions of Acceptability". It is the responsibility of the installer to ensure that the final product housing these components complies with the requirements of all applicable Safety standards and Directives for the final product. Component power supplies for general use should comply with the requirements in IEC60950, EN60950 and UL60950 "Safety of information technology equipment". There are other more product related standards, e.g. IEEE802.3af "Ethernet LAN/MAN Data terminal equipment power", and ETS300132-2 "Power supply interface at the input to telecommunications equipment; part 2: DC", but all of these standards are based on IEC/EN/UL60950 with regards to safety. Ericsson Power Modules DC/DC converters and DC/DC regulators are UL60950 recognized and certified in accordance with EN60950. The flammability rating for all construction parts of the products meets requirements for V-0 class material according to IEC 60695-11-10. The products should be installed in the end-use equipment, in accordance with the requirements of the ultimate application. Normally the output of the DC/DC converter is considered as SELV (Safety Extra Low Voltage) and the input source must be isolated by minimum Double or Reinforced Insulation from the primary circuit (AC mains) in accordance with IEC/EN/UL60950. Isolated DC/DC converters It is recommended that a slow blow fuse with a rating twice the maximum input current per selected product be used at the input of each DC/DC converter. If an input filter is used in the circuit the fuse should be placed in front of the input filter. In the rare event of a component problem in the input filter or in the DC/DC converter that imposes a short circuit on the input source, this fuse will provide the following functions: * * Isolate the faulty DC/DC converter from the input power source so as not to affect the operation of other parts of the system. Protect the distribution wiring from excessive current and power loss thus preventing hazardous overheating. The galvanic isolation is verified in an electric strength test. The test voltage (Viso) between input and output is 1500 Vdc or 2250 Vdc for 60 seconds (refer to product specification). Leakage current is less than 1 A at nominal input voltage. 24 V DC systems The input voltage to the DC/DC converter is SELV (Safety Extra Low Voltage) and the output remains SELV under normal and abnormal operating conditions. 48 and 60 V DC systems If the input voltage to Ericsson Power Modules DC/DC converter is 75 Vdc or less, then the output remains SELV (Safety Extra Low Voltage) under normal and abnormal operating conditions. Single fault testing in the input power supply circuit should be performed with the DC/DC converter connected to demonstrate that the input voltage does not exceed 75 Vdc. If the input power source circuit is a DC power system, the source may be treated as a TNV2 circuit and testing has demonstrated compliance with SELV limits and isolation requirements equivalent to Basic Insulation in accordance with IEC/EN/UL60950. Non-isolated DC/DC regulators The input voltage to the DC/DC regulator is SELV (Safety Extra Low Voltage) and the output remains SELV under normal and abnormal operating conditions. Limited Internal PRODUCT SPECIFICATION E Prepared (also subject responsible if other) 1 (5) No. MICOSPE Approved PKM 4000C PINB Series SEC/D (Julia You) 4 2/1301-BMR 637Technical 01/7 Uen Specification Checked Date Rev (EBAOCMA) 2006-12-20 DC/DC converters, Input 36-75 V, Output 55 A/204 W Reference EN/LZT 146 307 R4A August 2008 A (c) Ericsson Power Modules AB Absolute Maximum Ratings Characteristics min Tref Operating Temperature (see Thermal Consideration section) TS Storage temperature VI Input voltage Viso typ max Unit -40 +110 C -55 +125 C -0.5 +80 V Isolation voltage baseplate (input to output, input & output to baseplate test voltage) 2250 Vdc Viso Isolation voltage no baseplate option (input to output) 1500 Vdc Vtr Input voltage transient (Tp 100 ms) 100 V VRC Remote Control pin voltage (see Operating Information section) V Vadj Adjust pin voltage (see Operating Information section) Positive logic option -0.5 +15 Negative logic -0.5 +15 V -0.5 +2 V Stress in excess of Absolute Maximum Ratings may cause permanent damage. Absolute Maximum Ratings, sometimes referred to as no destruction limits, are normally tested with one parameter at a time exceeding the limits of Output data or Electrical Characteristics. If exposed to stress above these limits, function and performance may degrade in an unspecified manner. Fundamental Circuit Diagram Isolated Feedback Primary + In + Out Secondary + Out + Sense RC - In Control Control Voltage Monitoring Vadj - Sense - Out - Out Limited Internal PRODUCT SPECIFICATION E Prepared (also subject responsible if other) 2 (5) No. MICOSPE Approved Checked PKM 4000C PINB Series SEC/D (Kevin Zhou) 5 2/1301-BMR 637Technical 01/2 Uen Specification Date Rev Reference EN/LZT 146 307 R4A August 2008 (EBAOCMA) 2006-09-13 D DC/DC converters, Input 36-75 V, Output 55 A/204 W (c) Ericsson Power Modules AB 2.5 V Electrical Specification PKM 4119C PINB Tref = -40 to +90C, VI = 36 to 75 V, unless otherwise specified under Conditions. Typical values given at: Tref = +25C, VI= 53 V, max IO , unless otherwise specified under Conditions. Characteristics Conditions min typ max Unit 75 V VI Input voltage range VIoff Turn-off input voltage Decreasing input voltage 32 V VIon Turn-on input voltage Increasing input voltage 34 V 36 CI Internal input capacitance PO Output power Output voltage initial setting SVR Supply voltage rejection (ac) f = 100 Hz sinewave, 1 Vp-p Efficiency max IO 137.5 55 50 % of max IO F 5.7 0 W dB 91.5 88 89.2 50 % of max IO , VI = 48 V 91.7 max IO , VI = 48 V 88.9 % Pd Power Dissipation max IO Pli Input idling power IO= 0, VI = 53 V 2.6 W PRC Input standby power VI = 53 V (turned off with RC) 100 mW fs Switching frequency 0 -100% of max IO VOi Output voltage initial setting and Tref = +25C, VI = 53 V, IO = max IO accuracy Vadj, see Note 1 Output adjust range 18.8 W 180 200 220 kHz 2.45 2.50 2.55 V 2.21 2.81 V V Output voltage tolerance band 10-100% of max IO 2.40 2.60 Idling voltage IO = 0 2.40 2.60 V Line regulation max IO 15 mV Load regulation VI = 53 V, 1-100% of max IO 15 mV Vtr Load transient voltage deviation ttr Load transient recovery time VI = 53 V, Load step 25-75-25 % of max IO, di/dt = 1 A/s, see Note 2 VO tr ts Ramp-up time (from 10-90 % of VOi) Start-up time 250 mV 100 us 5 10 15 ms 10 15 50 ms 55 A 10-100% of max IO (from VI connection to 90% of VOi) IO Output current Ilim Current limit threshold Vo = 2.25 V, Tref < max Tref 63 A Isc Short circuit current Tref = 25C, 74 A 0 See ripple & noise section, VOac Output ripple & noise max IO, VO. Tref = +25C, VI = 53 V, IO = 0-100% OVP Over Voltage Protection of max IO Note 1: When using Vadj function, max output power (PO) must not be exceeded Note 2: Output filter according to Ripple & Noise section 80 3.4 130 mVp-p V Limited Internal PRODUCT SPECIFICATION E Prepared (also subject responsible if other) 3 (5) No. MICOSPE Approved Checked PKM 4000C PINB Series SEC/D (Kevin Zhou) 6 2/1301-BMR 637Technical 01/2 Uen Specification Date Rev Reference EN/LZT 146 307 R4A August 2008 (EBAOCMA) 2006-09-13 D DC/DC converters, Input 36-75 V, Output 55 A/204 W (c) Ericsson Power Modules AB 2.5 V Typical Characteristics PKM 4119C PINB Efficiency Power Dissipation [%] [W] 93 20 91 16 36 V 89 48 V 36 V 12 48 V 53 V 87 75 V 85 53 V 8 75 V 4 83 0 0 5 10 15 20 25 30 35 40 45 50 55 [A] 0 5 10 15 20 25 30 35 40 45 50 55 [A] Dissipated power vs. load current and input voltage at Tref = +25C Efficiency vs. load current and input voltage at Tref = +25C Output Current Derating Thermal Resistance [C/W] [A] 60,0 3.0 m/s 50,0 6 2.5 m/s 40,0 2.0 m/s 30,0 4 1.5 m/s 20,0 1.0 m/s 10,0 Nat. Conv. 0,0 2 0 20 30 40 50 60 70 80 90 100 [C] 0,0 Available load current vs. ambient air temperature and airflow at VI = 53 V. See Thermal Consideration section. 0,5 1,0 1,5 2,0 2,5 3,0 [m/s] Thermal resistance vs. airspeed measured at the converter. Tested in wind tunnel with airflow and test conditions as per the Thermal consideration section. [V] [V] 2,60 3,0 2,5 2,55 36 V 48 V 2,50 2,0 36 V 1,5 48 V 1,0 53 V 53 V 75 V 2,45 75 V 0,5 2,40 0 5 10 15 20 25 30 35 40 45 50 55 [A] Output voltage vs. load current at Tref = +25C 0,0 55,0 60,0 65,0 70,0 75,0 80,0 [A] Output voltage vs. load current at IO > max IO , Tref = +25C Limited Internal PRODUCT SPECIFICATION E Prepared (also subject responsible if other) 4 (5) No. MICOSPE Approved PKM 4000C PINB Series SEC/D (Kevin Zhou) Checked 2/1301-BMR 637Technical 01/2 Uen Specification Date Rev (EBAOCMA) 2006-09-13 DC/DC converters, Input 36-75 V, Output 55 A/204 W EN/LZT 146 307 R4A August 2008 D (c) Ericsson Power Modules AB 2.5 V Typical Characteristics Start-up PKM 4119C PINB Shut-down Place your graph here Start-up enabled by connecting VI at: Tref = +25C, IO = 55 A resistive load, VI = 53 V. Top trace: output voltage (5 V/div.). Bottom trace: input voltage (20 V/div.). Time scale: 5 ms/div.. Output Ripple & Noise Output voltage ripple (50mV/div.) at: Tref = +25C, IO = 55 A resistive load, VI = {53 V}. Time scale: 5 s/div. Shut-down enabled by disconnecting VI at: Tref = +25C, IO = 10 A load, VI = 53 V Top trace: output voltage (1 V/div.). Bottom trace: input voltage (20 V/div.). Time scale: 0.1 ms/div.. Output Load Transient Response Place your graph here See the filter in the Output ripple and noise section (EMC Specification). Place your graph here Output voltage response to load current step- Top trace: output voltage (100mV/div.). change (13.8-41.4-13.8 A) at: Bottom trace: load current (13.8 A/div.). Tref =+25C, VI = 53 V. Time scale: {0.1 ms/div.}. Output Voltage Adjust (see operating information) Passive trim The resistor value for an adjusted output voltage is calculated by using the following equations: Output Voltage Adjust Upwards, Increase: Radj= 5.11((2.5(100+%))/1.225%-(100+2%)/%) kOhm Eg Increase 4% =>Vout =2.6 Vdc 5.11(2.5(100+4)/1.225x4-(100+2x4)/4 = 133 kOhm Output Voltage Adjust Downwards, Decrease: Radj= 5.11(100/%-2) kOhm Eg Decrease 2% =>Vout = 2.45 Vdc 5.11(100/2-2)= 245 kOhm 7 Reference The PKM4000C series DC/DC converters can be offered with a baseplate. Baseplate helps to cool hotspots more efficient during heavy load. The baseplate have approximately 5C improved derating compared to datasheet showing non baseplated PKM4000C. The baseplate is intended to be mounted on a cold wall to transfer heat away from the converter. By mounting PKM4000C in this way thermal derating can be improved by more than 10C . Limited Internal PRODUCT SPECIFICATION E Prepared (also subject responsible if other) 2 (5) No. MICOSPE Approved PKM 4000C PINB Series SEC/D (Kevin Zhou) 8 2/1301-BMR 637Technical 01/1 Uen Specification Checked Date (MICJAKE) 2006-09-12 Rev Reference EN/LZT 146 307 R4A August 2008 B DC/DC converters, Input 36-75 V, Output 55 A/204 W (c) Ericsson Power Modules AB 3.3 V Electrical Specification PKM 4110C PINB Tref = -40 to +90C, VI = 36 to 75 V, unless otherwise specified under Conditions. Typical values given at: Tref = +25C, VI= 53 V, max IO , unless otherwise specified under Conditions. Characteristics Conditions min typ max Unit 75 V VI Input voltage range VIoff Turn-off input voltage Decreasing input voltage 32 V VIon Turn-on input voltage Increasing input voltage 34 V 36 CI Internal input capacitance PO Output power Output voltage initial setting SVR Supply voltage rejection (ac) f = 100 Hz sinewave, 1 Vp-p Efficiency max IO 165 50 50 % of max IO F 5.7 0 W dB 92.2 89 90.3 50 % of max IO , VI = 48 V 92.3 max IO , VI = 48 V 90.1 % Pd Power Dissipation max IO Pli Input idling power IO= 0, VI = 53 V 3.4 W PRC Input standby power VI = 53 V (turned off with RC) 100 mW fs Switching frequency 0 -100% of max IO VOi Output voltage initial setting and Tref = +25C, VI = 53 V, IO = max IO accuracy Vadj, see Note 1 Output adjust range 20.4 145 155 W 165 kHz 3.24 3.36 V 2.97 3.63 V V Output voltage tolerance band 10-100% of max IO 3.23 3.37 Idling voltage IO = 0 3.23 3.37 V Line regulation max IO 15 mV Load regulation VI = 53 V, 1-100% of max IO 15 mV Vtr Load transient voltage deviation ttr Load transient recovery time VI = 53 V, Load step 25-75-25 % of max IO, di/dt = 1 A/s, see Note 2 VO tr ts Ramp-up time (from 10-90 % of VOi) Start-up time 500 mV 100 us 7 10 30 ms 10 15 50 ms 50 A 10-100% of max IO (from VI connection to 90% of VOi) IO Output current Ilim Current limit threshold Vo = 2.97 V, Tref < max Tref 61 A Isc Short circuit current Tref = 25C, VO = < VOnom * 0.1 65 A 0 See ripple & noise section, VOac Output ripple & noise max IO, VO. Tref = +25C, VI = 53 V, IO = 0-100% OVP Over Voltage Protection of max IO Note 1: When using Vadj function, max output power (PO) must not be exceeded Note 2: Output filter according to Ripple & Noise section 60 4.2 125 mVp-p V Limited Internal PRODUCT SPECIFICATION E Prepared (also subject responsible if other) 3 (5) No. MICOSPE Approved PKM 4000C PINB Series SEC/D (Kevin Zhou) 9 2/1301-BMR 637Technical 01/1 Uen Specification Checked Date Rev (MICJAKE) 2006-09-12 Reference EN/LZT 146 307 R4A August 2008 B DC/DC converters, Input 36-75 V, Output 55 A/204 W (c) Ericsson Power Modules AB 3.3 V Typical Characteristics PKM 4110C PINB Efficiency Power Dissipation [%] [W] 93 20 91 36 V 89 48 V 53 V 87 75 V 85 16 36 V 12 48 V 53 V 8 75 V 4 83 0 0 5 10 15 20 25 30 35 40 45 50 [A ] 0 5 10 15 20 25 30 35 40 45 50 [A] Dissipated power vs. load current and input voltage at Tref = +25C Efficiency vs. load current and input voltage at Tref = +25C Output Current Derating Thermal Resistance [A] 50,0 [C/W] 3.0 m/s 40,0 2.5 m/s 30,0 2.0 m/s 6 4 1.5 m/s 20,0 1.0 m/s 10,0 2 Nat. Conv. 0 0,0 0,0 20 30 40 50 60 70 80 90 0,5 1,0 1,5 2,0 2,5 3,0 [m/s] 100 [C] Available load current vs. ambient air temperature and airflow at VI = 53 V. See Thermal Consideration section. Thermal resistance vs. airspeed measured at the converter. Tested in wind tunnel with airflow and test conditions as per the Thermal consideration section. [V] [V] 3,40 4,0 3,35 3,0 36 V 48 V 3,30 36 V 2,0 48 V 53 V 75 V 3,25 3,20 0 5 10 15 20 25 30 35 40 45 Output voltage vs. load current at Tref = +25C 50 [A] 53 V 1,0 75 V 0,0 50,0 55,0 60,0 65,0 70,0 75,0 [A] Output voltage vs. load current at IO > max IO , Tref = +25C Limited Internal PRODUCT SPECIFICATION E Prepared (also subject responsible if other) 4 (5) No. MICOSPE Approved PKM 4000C PINB Series SEC/D (Kevin Zhou) 2/1301-BMR 637Technical 01/1 Uen Specification Checked Date Rev (MICJAKE) 2006-09-12 DC/DC converters, Input 36-75 V, Output 55 A/204 W EN/LZT 146 307 R4A August 2008 B (c) Ericsson Power Modules AB 3.3 V Typical Characteristics Start-up 10 Reference PKM 4110C PINB Shut-down Place your graph here Start-up enabled by connecting VI at: Tref = +25C, IO = 50 A resistive load, VI = 53 V. Top trace: output voltage (1 V/div.). Bottom trace: input voltage (20 V/div.). Time scale: 5 ms/div.. Output Ripple & Noise Top trace: output voltage (1 V/div.). Bottom trace: input voltage (20 V/div.). Time scale: 0.1 ms/div.. Output Load Transient Response Place your graph here Output voltage ripple (20mV/div.) at: Tref = +25C, IO = 50 A resistive load, VI = {53 V}. Time scale: 5 s/div. Shut-down enabled by disconnecting VI at: Tref = +25C, IO = 10 A load, VI = 53 V See the filter in the Output ripple and noise section (EMC Specification). Place your graph here Output voltage response to load current step- Top trace: output voltage (200mV/div.). change (12.5-47.5-12.5 A) at: Bottom trace: load current (12.5 A/div.). Tref =+25C, VI = 53 V. Time scale: {0.1 ms/div.}. Output Voltage Adjust (see operating information) Passive trim The resistor value for an adjusted output voltage is calculated by using the following equations: Output Voltage Adjust Upwards, Increase: Radj= 5.11((3.3(100+%))/1.225%-(100+2%)/%) kOhm Eg Increase 4% =>Vout =3.43 Vdc 5.11(3.3(100+4)/1.225x4-(100+2x4)/4 = 220 kOhm Output Voltage Adjust Downwards, Decrease: Radj= 5.11(100/%-2) kOhm Eg Decrease 2% =>Vout = 3.23 Vdc 5.11(100/2-2)= 245 kOhm The PKM4000C series DC/DC converters can be offered with a baseplate. Baseplate helps to cool hotspots more efficient during heavy load. The baseplate have approximately 5C improved derating compared to datasheet showing non baseplated PKM4000C. The baseplate is intended to be mounted on a cold wall to transfer heat away from the converter. By mounting PKM4000C in this way thermal derating can be improved by more than 10C . Limited Internal PRODUCT SPECIFICATION E Prepared (also subject responsible if other) 2 (5) No. MICOSPE Approved PKM 4000C PINB Series MPM/BM/Y (Maria Rosendahl) 2/1301-BMR 637Technical 01/3 Uen Specification Checked Date (MICJAKE) 2006-09-12 Rev 11 Reference EN/LZT 146 307 R4A August 2008 F DC/DC converters, Input 36-75 V, Output 55 A/204 W (c) Ericsson Power Modules AB 5.0 V Electrical Specification PKM 4211C PINB Tref = -40 to +90C, VI = 36 to 75 V, unless otherwise specified under Conditions. Typical values given at: Tref = +25C, VI= 53 V, max IO , unless otherwise specified under Conditions. Characteristics Conditions min typ max Unit 75 V VI Input voltage range VIoff Turn-off input voltage Decreasing input voltage 32 V VIon Turn-on input voltage Increasing input voltage 34 V CI Internal input capacitance 5.7 F PO Output power Output voltage initial setting SVR Supply voltage rejection (ac) f = 100 Hz sinewave, 1 Vp-p 36 0 50 % of max IO Efficiency max IO 200 70 92.9 90 91.3 50 % of max IO , VI = 48 V 93.0 max IO , VI = 48 V 91.2 Pd Power Dissipation max IO Pli Input idling power IO= 0, VI = 53 V PRC Input standby power VI = 53 V (turned off with RC) fs Switching frequency 0 -100% of max IO VOi Output voltage initial setting and Tref = +25C, VI = 53 V, IO = 40.0 A accuracy Vadj, see Note 1 Output adjust range W dB % 22.2 3.1 W W 100 mW 180 200 220 kHz 4.90 5.00 5.10 V 4.50 5.50 V Output voltage tolerance band 10-100% of max IO 4.80 5.20 V Idling voltage IO = 0 4.80 5.20 V Line regulation max IO 35 mV Load regulation VI = 53 V, 1-100% of max IO 35 mV Vtr Load transient voltage deviation ttr Load transient recovery time VI = 53 V, Load step 25-75-25 % of max IO, di/dt = 1 A/s, see Note 2 VO tr ts Ramp-up time (from 10-90 % of VOi) Start-up time 700 mV 100 Us 7 13 30 ms 9 15 50 ms 40 A 10-100% of max IO (from VI connection to 90% of VOi) IO Output current Ilim Current limit threshold Vo = 4.5 V, Tref < max Tref 54 A Isc Short circuit current Tref = 25C, VO = < VOnom * 0.1 67 A 0 See ripple & noise section, VOac Output ripple & noise max IO, VO. Tref = +25C, VI = 53 V, IO = 0-100% OVP Over Voltage Protection of max IO Note 1: When using Vadj function, max output power (PO) must not be exceeded Note 2: Output filter according to Ripple & Noise section 60 6.2 150 mVp-p V Limited Internal PRODUCT SPECIFICATION E Prepared (also subject responsible if other) 3 (5) No. MICOSPE Approved PKM 4000C PINB Series MPM/BM/Y (Maria Rosendahl) 12 2/1301-BMR 637Technical 01/3 Uen Specification Checked Date Rev (MICJAKE) 2006-09-12 DC/DC converters, Input 36-75 V, Output 55 A/204 W Reference EN/LZT 146 307 R4A August 2008 F (c) Ericsson Power Modules AB 5.0 V Typical Characteristics PKM 4211C PINB Efficiency Power Dissipation [%] [W] 95 24 20 93 91 36 V 16 48 V 12 53 V 89 36 V 48 V 53 V 8 75 V 75 V 87 4 0 85 0,0 5,0 0,0 10,0 15,0 20,0 25,0 30,0 35,0 40,0 [A] 5,0 10,0 15,0 20,0 25,0 30,0 35,0 40,0[A ] Dissipated power vs. load current and input voltage at Tref = +25C Efficiency vs. load current and input voltage at Tref = +25C Output Current Derating Thermal Resistance [C/W] [A] 40,0 8 3.0 m/s 30,0 2.5 m/s 6 2.0 m/s 20,0 1.5 m/s 1.0 m/s 10,0 4 Nat. Conv. 0,0 2 20 30 40 50 60 70 80 90 100 [C] 0,0 Available load current vs. ambient air temperature and airflow at VI = 53 V. See Thermal Consideration section. 0,5 1,0 1,5 2,0 2,5 3,0[m/s] Thermal resistance vs. airspeed measured at the converter. Tested in wind tunnel with airflow and test conditions as per the Thermal consideration section. Output Characteristics Current Limit Characteristics [V] [V] 5,20 6,0 5,0 5,10 36 V 48 V 5,00 53 V 75 V 4,0 36 V 48 V 3,0 53 V 75 V 2,0 4,90 1,0 4,80 0,0 0,0 5,0 10,0 15,0 20,0 25,0 30,0 35,0 40,0 [A ] Output voltage vs. load current at Tref = +25C 40,0 45,0 50,0 55,0 60,0 65,0 70,0[A ] Output voltage vs. load current at IO > max IO , Tref = +25C Limited Internal PRODUCT SPECIFICATION E Prepared (also subject responsible if other) 4 (5) No. MICOSPE Approved PKM 4000C PINB Series MPM/BM/Y (Maria Rosendahl) 2/1301-BMR 637Technical 01/3 Uen Specification Checked Date Rev (MICJAKE) 2006-09-12 DC/DC converters, Input 36-75 V, Output 55 A/204 W EN/LZT 146 307 R4A August 2008 F (c) Ericsson Power Modules AB 5.0 V Typical Characteristics Start-up 13 Reference PKM 4211C PINB Shut-down Place your graph here Start-up enabled by connecting VI at: Tref = +25C, IO = 40 A resistive load, VI = 53 V. Top trace: output voltage (2 V/div.). Bottom trace: input voltage (20 V/div.). Time scale: 5 ms/div.. Output Ripple & Noise Output voltage: 2 V/div Time scale: 2 ms/div. Output Load Transient Response Place your graph here Output voltage ripple (20mV/div.) at: Tref = +25C, IO = 40 A resistive load, VI = {53 V}. Time scale: 2 s/div. Shut-down enabled by disconnecting VI at: Tref = +25C, IO = 4 A resistive load, Place your graph here See the filter in the Output ripple and noise section (EMC Specification). Output voltage response to load current step- Top trace: output voltage (500mV/div.). change (10-30-10 A) at: Bottom trace: load current (10 A/div.). Tref =+25C, VI = 53 V. Time scale: {0.1 ms/div.}. Output Voltage Adjust (see operating information) Passive trim The resistor value for an adjusted output voltage is calculated by using the following equations: Output Voltage Adjust Upwards, Increase: Radj= 5.11((5(100+%))/1.225%-(100+2%)/%) kOhm Eg Increase 4% =>Vout =5.2 Vdc 5.11(5(100+4)/1.225x4-(100+2x4)/4 = 404 kOhm0 Output Voltage Adjust Downwards, Decrease: Radj= 5.11(100/%-2) kOhm Eg Decrease 2% =>Vout = 4.90 Vdc 5.11(100/2-2)= 245 kOhm The PKM4000C series DC/DC converters can be offered with a baseplate. Baseplate helps to cool hotspots more efficient during heavy load. The baseplate have approximately 5C improved derating compared to datasheet showing non baseplated PKM4000C. The baseplate is intended to be mounted on a cold wall to transfer heat away from the converter. By mounting PKM4000C in this way thermal derating can be improved by more than 10C . Limited Internal PRODUCT SPECIFICATION E Prepared (also subject responsible if other) 2 (5) No. MICOSPE Approved PKM 4000C PINB Series MPM/BY/B (Maria Rosendahl) 2/1301-BMR 637Technical 01/57 Uen Specification Checked Date (MICJAKE) 2006-06-20 Rev 14 Reference EN/LZT 146 307 R4A August 2008 D DC/DC converters, Input 36-75 V, Output 55 A/204 W (c) Ericsson Power Modules AB 12 V Electrical Specification PKM 4213C PINBSP Tref = -40 to +90C, VI = 38 to 75 V, unless otherwise specified under Conditions. Typical values given at: Tref = +25C, VI= 53 V, max IO , unless otherwise specified under Conditions. Characteristics Conditions min typ max Unit VI Input voltage range VIoff Turn-off input voltage Decreasing input voltage 32 V VIon Turn-on input voltage Increasing input voltage 34 V 38 CI Internal input capacitance PO Output power Output voltage initial setting SVR Supply voltage rejection (ac) f = 100 Hz sinewave, 1 Vp-p Efficiency max IO V F 5.7 0 204 61 50 % of max IO 75 W dB 94.2 92 93.4 50 % of max IO , VI = 48 V 94.4 max IO , VI = 48 V 93.3 % Pd Power Dissipation max IO Pli Input idling power IO= 0, VI = 53 V 2.8 W PRC Input standby power VI = 53 V (turned off with RC) 100 mW fs Switching frequency 0 -100% of max IO VOi Output voltage initial setting and Tref = +25C, VI = 53 V, IO = max IO accuracy Vadj, see Note 1 Output adjust range VO Vtr ttr tr ts 17.7 W 180 200 220 kHz 11.8 12.0 12.2 V 10.8 13.2 V V Output voltage tolerance band 10-100% of max IO 11.7 12.3 Idling voltage IO = 0 11.8 12.2 V Line regulation max IO 50 mV Load regulation VI = 53 V, 1-100% of max IO 20 mV Load transient voltage deviation VI = 53 V, Load step 25-75-25 % of max IO, di/dt = 1 A/s, see Note 2 Load transient recovery time Ramp-up time (from 10-90 % of VOi) Start-up time Output current Ilim Current limit threshold Isc Short circuit current VOac Output ripple & noise OVP Over Voltage Protection mV 100 us 5 9 20 ms 7 10 50 ms 17 A 10-100% of max IO (from VI connection to 90% of VOi) IO 800 0 Vo = 10.8 V, Tref < max Tref 21 A Tref = 25C, VO = < VOnom * 0.1 26 A See ripple & noise section, max IO, VO. Tref = +25C, VI = 53 V, IO = 0-100% of max IO Note 1: When using Vadj function, max output power (PO) must not be exceeded Note 2: Output filter according to Ripple & Noise section 100 14.3 200 mVp-p V Limited Internal PRODUCT SPECIFICATION E Prepared (also subject responsible if other) 3 (5) No. MICOSPE Approved PKM 4000C PINB Series MPM/BY/B (Maria Rosendahl) 15 2/1301-BMR 637Technical 01/57 Uen Specification Checked Date Rev (MICJAKE) 2006-06-20 Reference EN/LZT 146 307 R4A August 2008 D DC/DC converters, Input 36-75 V, Output 55 A/204 W (c) Ericsson Power Modules AB 12 V Typical Characteristics PKM 4213C PINBSP Efficiency Power Dissipation [%] [W] 95 16 93 12 38 V 38 V 91 48 V 48 V 8 53 V 53 V 89 75 V 87 75 V 4 0 85 0,0 3,0 6,0 9,0 12,0 15,0 0,0 18,0 [A] 3,0 6,0 9,0 12,0 15,0 18,0 [A] Dissipated power vs. load current and input voltage at Tref = +25C Efficiency vs. load current and input voltage at Tref = +25C Output Current Derating Thermal Resistance [C/W] [A] 18,0 8 3.0 m/s 15,0 2.5 m/s 12,0 2.0 m/s 9,0 6 1.5 m/s 6,0 1.0 m/s 3,0 Nat. Conv. 0,0 20 30 40 50 60 70 80 90 4 2 100 [C] 0,0 Available load current vs. ambient air temperature and airflow at VI = 53 V. See Thermal Consideration section. Output Characteristics 0,5 1,0 1,5 2,0 2,5 3,0 [m/s] Thermal resistance vs. airspeed measured at the converter. Tested in wind tunnel with airflow and test conditions as per the Thermal consideration section. Current Limit Characteristics [V] [V] 12,20 15,0 12,0 12,10 38 V 48 V 12,00 53 V 38 V 9,0 48 V 53 V 6,0 75 V 75 V 11,90 3,0 11,80 0,0 3,0 6,0 9,0 12,0 15,0 18,0 [A] Output voltage vs. load current at Tref = +25C 0,0 17,0 19,0 21,0 23,0 25,0 27,0 [A] Output voltage vs. load current at IO > max IO , Tref = +25C Limited Internal PRODUCT SPECIFICATION E Prepared (also subject responsible if other) MICOSPE Approved PKM 4000C PINB Series MPM/BY/B (Maria Rosendahl) 4 (5) No. 2/1301-BMR 637Technical 01/57 Uen Specification Checked Date Rev (MICJAKE) 2006-06-20 DC/DC converters, Input 36-75 V, Output 55 A/204 W EN/LZT 146 307 R4A August 2008 D (c) Ericsson Power Modules AB 12 V Typical Characteristics Start-up 16 Reference PKM 4213C PINBSP Shut-down Place your graph here Start-up enabled by connecting VI at: Tref = +25C, IO = 17 A resistive load, VI = 53 V. Top trace: output voltage (5 V/div.). Bottom trace: input voltage (20 V/div.). Time scale: 5 ms/div.. Output Ripple & Noise Shut-down enabled by disconnecting VI at: Tref = +25C, IO = 0 A, Output Load Transient Response Place your graph here Output voltage ripple (50mV/div.) at: Tref = +25C, IO = 17 A resistive load, VI = {53 V}. Time scale: 2 s/div. See the filter in the Output ripple and noise section (EMC Specification). Output Voltage Adjust (see operating information) Passive trim The resistor value for an adjusted output voltage is calculated by using the following equations: Output Voltage Adjust Upwards, Increase: Radj= 5.11((12(100+%))/1.225%-(100+2%)/%) kOhm Eg Increase 4% =>Vout =12.48 Vdc 5.11(12(100+4)/1.225x4-(100+2x4)/4 = 404 kOhm Output Voltage Adjust Downwards, Decrease: Radj= 5.11(100/%-2) kOhm Eg Decrease 2% =>Vout = 11.76 Vdc 5.11(100/2-2)= 245 kOhm Output voltage (5 V/div.). Time scale: 50us/div.. Place your graph here Output voltage response to load current stepchange (4.25-12.75-4.25 A) at: Tref =+25C, VI = 53 V. Top trace: output voltage (500mV/div.). Bottom trace: load current (4.25 A/div.). Time scale: {0.1 ms/div.}. Baseplate The PKM4000C series DC/DC converters can be offered with a baseplate. Baseplate helps to cool hotspots more efficient during heavy load. The baseplate have approximately 5C improved derating compared to datasheet showing non baseplated PKM4000C. The baseplate is intended to be mounted on a cold wall to transfer heat away from the converter. By mounting PKM4000C in this way thermal derating can be improved by more than 10C. E Technical Specification PKM 4000C PINB Series SEC/D (Julia You) EYINGJI 2007-12-10 DC/DC converters, Input 36-75 V, Output 55 A/204 W 17 EN/LZT 146 307 R4A August 2008 C (c) Ericsson Power Modules AB EMC Specification Conducted EMI measured according to EN55022, CISPR 22 and FCC part 15J (see test set-up). The fundamental switching frequency is 200 kHz for PKM 4211C PINB @ VI = 53 V, max IO. Conducted EMI Input terminal value (typ) Test set-up Layout recommendation The radiated EMI performance of the DC/DC converter will depend on the PCB layout and ground layer design. It is also important to consider the stand-off of the DC/DC converter. If a ground layer is used, it should be connected to the output of the DC/DC converter and the equipment ground or chassis. EMI without filter External filter (class B) A ground layer will increase the stray capacitance in the PCB and improve the high frequency EMC performance. Required external input filter in order to meet class B in EN 55022, CISPR 22 and FCC part 15J. Output ripple and noise Output ripple and noise measured according to figure below. See Design Note 022 for detailed information. Filter components: C1 = 0.68 F C2,3 = 1.0 F C4,5 = 2.2 nF C6,7 = 100 uF L1,2 = 0.768 mH Output ripple and noise test setup EMI with filter E ESKEVIN Approved PKM 4000C PINB Series SEC/D (Julia You) 3/1301-BMR 637Technical 01 Uen Specification Checked Date EYINGJI 2007-12-10 DC/DC converters, Input 36-75 V, Output 55 A/204 W Operating information Input Voltage The input voltage range 36 to 75Vdc meets the requirements of the European Telecom Standard ETS 300 132-2 for normal input voltage range in --48 and --60 Vdc systems, -40.5 to 57.0 V and --50.0 to -72 V respectively. At input voltages exceeding 75 V, the power loss will be higher than at normal input voltage and Tref must be limited to absolute max +110C. The absolute maximum continuous input voltage is 80Vdc. Turn-off Input Voltage The PKM 4000CSeries DC/DC converters monitor the input voltage and will turn on and turn off at predetermined levels. The minimum hysteresis between turn on and turn off input voltage is 1 V. Remote Control (RC) The products are fitted with a remote control function referenced to the primary negative input connection (- In), with negative and positive logic options available. The RC function allows the converter to be turned on/off by an external device like a semiconductor or mechanical switch. The RC pin has an internal pull up resistor to + In. The maximum required sink current is 1 mA. When the RC pin is left open, the voltage generated on the RC pin is 3.5 -- 6.0 V. The second option is "positive logic" remote control, which can be ordered by adding the suffix "P" to the end of the part number. The converter will turn on when the input voltage is applied with the RC pin open. Turn off is achieved by connecting the RC pin to the - In. To ensure safe turn off the voltage difference between RC pin and the - In pin shall be less than 1V. The converter will restart automatically when this connection is opened. See Design Note 021 for detailed information. Input and Output Impedance The impedance of both the power source and the load will interact with the impedance of the DC/DC converter. It is most important to have a low characteristic impedance, both at the input and output, as the converters have a low energy storage capability. The PKM 4000CSeries DC/DC converters have been designed to be completely stable without the need for external capacitors on the input or the output circuits. The performance in some applications can be enhanced by addition of external capacitance as described under maximum capacitive load. If the distribution of the input voltage source to the converter contains significant inductance, the addition of a 100F capacitor across the input of the converter will help insure stability. This capacitor Rev 18 Reference EN/LZT 146 307 R4A August 2008 C (c) Ericsson Power Modules AB is not required when powering the DC/DC converter from a low impedance source with short, low inductance, input power leads. External Decoupling Capacitors When powering loads with significant dynamic current requirements, the voltage regulation at the point of load can be improved by addition of decoupling capacitors at the load. The most effective technique is to locate low ESR ceramic and electrolytic capacitors as close to the load as possible, using several parallel capacitors to lower the effective ESR. The ceramic capacitors will handle high-frequency dynamic load changes while the electrolytic capacitors are used to handle low frequency dynamic load changes. Ceramic capacitors will also reduce any high frequency noise at the load. It is equally important to use low resistance and low inductance PCB layouts and cabling. External decoupling capacitors will become part of the control loop of the DC/DC converter and may affect the stability margins. As a "rule of thumb", 100 F/A of output current can be added without any additional analysis. The ESR of the capacitors is a very important parameter. Power Modules guarantee stable operation with a verified ESR value of >10 m across the output connections. For further information please contact your local Ericsson Power Modules representative. Output Voltage Adjust (Vadj) All PKM 4000CSeries DC/DC converters have an Output Voltage adjust pin (Vadj). This pin can be used to adjust the output voltage above or below Output voltage initial setting. When increasing the output voltage, the voltage at the output pins (including any remote sense offset) must be kept below the maximum output adjust range. Also note that at increased output voltages the maximum power rating of the converter remains the same, and the output current capability will decrease correspondingly. To decrease the output voltage the resistor should be connected between Vadj pin and --Sense pin. To increase the voltage the resistor should be connected between Vadj pin and +Sense pin. The resistor value of the Output voltage adjust function is according to information given under the output section. E ESKEVIN Approved PKM 4000C PINB Series SEC/D (Julia You) 3/1301-BMR 637Technical 01 Uen Specification Checked Date EYINGJI 2007-12-10 Rev 19 Reference EN/LZT 146 307 R4A August 2008 C DC/DC converters, Input 36-75 V, Output 55 A/204 W (c) Ericsson Power Modules AB Operating information continued Thermal Consideration Parallel Operation General The PKM 4000CSeries DC/DC converters can be paralleled for redundancy if external o-ring diodes are used in series with the outputs. It is not recommended to parallel the PKM 4000C Series DC/DC converters for increased power without using external current sharing circuits. The PKM 4000Cseries DC/DC converters are designed to operate in a variety of thermal environments, however sufficient cooling should be provided to help ensure reliable operation. Heat is removed by conduction, convection and radiation to the surrounding environment. Increased airflow enhances the heat transfer via convection. The available load current vs. ambient air temperature and airflow at Vin =53 V for each model is according to the information given under the output section. The test is done in a wind tunnel with a cross section of 305 x 305 mm, the DC/DC converter vertically mounted on a 16 layer Pcb with a size of 254 x 254 mm, each layer with 35 m (1 oz) copper. Proper cooling can be verified by measuring the temperature of selected devices. Peak temperature can occur at positions P1 - P4. The temperature at these positions should not exceed the recommended max values. See Design Note 006 for detailed information. Remote Sense All PKM 4000CSeries DC/DC converters have remote sense that can be used to compensate for moderate amounts of resistance in the distribution system and allow for voltage regulation at the load or other selected point. The remote sense lines will carry very little current and do not need a large cross sectional area. However, the sense lines on the Pcb should be located close to a ground trace or ground plane. In a discrete wiring situation, the use of twisted pair wires or other technique to reduce noise susceptibility is highly recommended. The remote sense circuitry will compensate for up to 10% voltage drop between the sense voltage and the voltage at the output pins. The output voltage and the remote sense voltage offset must be less than the minimum over voltage trip point. If the remote sense is not needed the --Sense should be connected to --Out and +Sense should be connected to +Out. Over Temperature Protection (OTP) The PKM 4000CSeries DC/DC converters are protected from thermal overload by an internal over temperature shutdown circuit. When the Pcb temperature (TC reference point) exceeds the temperature trig point (~120 C) the OTP circuit will cut down output power. The converter will stop until safe operating temperature is restored. Hysteresis between OTP trig point and restart is approx 10C. Time between OTP and restart is dependant on cooling of DC/DC converter. Over Voltage Protection (OVP) The PKM 4000CSeries DC/DC converters have output overvoltage protection. In the event of an output overvoltage condition, the converter will shut down immediately. The converter make continous attempts to start up (non-latching mode) and resume normal operation automatically. Over Current Protection (OCP) The PKM 4000CSeries DC/DC converters include current limiting circuitry that allows them to withstand continuous overloads or short circuit conditions on the output. The output voltage will decrease towards zero for output currents in excess of max output current (Iomax). The converter will resume normal operation after removal of the overload. The load distribution system should be designed to carry the maximum output short circuit current specified. Note that the max value is the absolute maximum rating (non destruction) and that the electrical Output data is guaranteed up to Tref +90C. See Design Note 019 for further information. Position Device Designation max value P1 Pcb Tref 110 C P2 Mosfet Tsurface 120 C P3 Mosfet Tsurface 120 C P4 Transformer Tsurface 130 C E ESKEVIN Approved PKM 4000C PINB Series SEC/D (Julia You) 3/1301-BMR 637Technical 01 Uen Specification Checked Date Rev EYINGJI 2007-12-10 EN/LZT 146 307 R4A August 2008 C DC/DC converters, Input 36-75 V, Output 55 A/204 W Thermal Consideration continued Reference (c) Ericsson Power Modules AB Connections Definition of reference temperature (Tref) The reference temperature is used to monitor the temperature limits of the product. Temperatures above maximum Tref are not allowed and may cause degradation or permanent damage to the product. Tref is also used to define the temperature range for normal operating conditions. Tref is defined by the design and used to guarantee safety margins, proper operation and high reliability of the module. Ambient Temperature Calculation By using the thermal resistance the maximum allowed ambient temperature can be calculated. 1. The power loss is calculated by using the formula ((1/) - 1) x output power = power losses (Pd). = efficiency of converter. E.g 90 % = 0.90 2. Find the thermal resistance (Rth) in the Thermal Resistance graph found in the Output section for each model. Calculate the temperature increase (T). T = Rth x Pd 3. Max allowed ambient temperature is: Max Tref - T. E.g PKM 4213C PINBSP at 2m/s: 1. (( 1 ) - 1) x 204 W = 14.6 W 0.933 2. 14.6 W x 5.7C/W = 83C 3. 110 C -- 83C = max ambient temperature is 27C The real temperature will be dependent on several factors, like Pcb size and type, direction of airflow, air turbulence etc. It is recommended to verify the temperature by testing. Top View Pin Designation Function 1 +In Positive input 2 RC Remote control 3 - In Negative input 4,10 - Out Negative output 5 - Sen Negative remote sense 6 Vadj Output voltage adjust 7 + Sen Positive remote sense 8,9 + Out Positive output 20 E Ericsson Internal PRODUCT SPECIFICATION Prepared (also subject responsible if other) MICUPEZ Approved 4/1301-BMR 637 01 Uen Checked Date PKM 4000C PINB Series 2006-10-30 DC/DC converters, Input 36-75 V, Output 55 A/204 W Mechanical Drawing for Single Pin out 1 (7) No. TechnicalReference Specification Rev EN/LZT 146 307 R4A August 2008 C (c) Ericsson Power Modules AB 21 E Ericsson Internal PRODUCT SPECIFICATION Prepared (also subject responsible if other) MICUPEZ Approved 4/1301-BMR 637 01 Uen Checked Date PKM 4000C PINB Series 2006-10-30 DC/DC converters, Input 36-75 V, Output 55 A/204 W Mechanical Drawing for Double Pin out 2 (7) No. TechnicalReference Specification Rev EN/LZT 146 307 R4A August 2008 C (c) Ericsson Power Modules AB 22 E Ericsson Internal PRODUCT SPECIFICATION Prepared (also subject responsible if other) MICUPEZ Approved 3 (7) No. 4/1301-BMR 637 01 Uen Checked Date PKM 4000C PINB Series 2006-10-30 DC/DC converters, Input 36-75 V, Output 55 A/204 W Mechanical Drawing for Base plate option with Single Pin out TechnicalReference Specification Rev EN/LZT 146 307 R4A August 2008 C (c) Ericsson Power Modules AB 23 E Ericsson Internal PRODUCT SPECIFICATION Prepared (also subject responsible if other) MICUPEZ Approved 4 (7) No. 4/1301-BMR 637 01 Uen Checked Date PKM 4000C PINB Series 2006-10-30 DC/DC converters, Input 36-75 V, Output 55 A/204 W Mechanical Drawing for Base plate option with Double Pin out TechnicalReference Specification Rev EN/LZT 146 307 R4A August 2008 C (c) Ericsson Power Modules AB 24 E Ericsson Internal PRODUCT SPECIFICATION Prepared (also subject responsible if other) MICUPEZ 4/1301-BMR 637 01 Uen Approved Checked Date PKM 4000C PINB Series 2006-10-30 DC/DC converters, Input 36-75 V, Output 55 A/204 W Soldering Information -- Through hole mounting The product is intended for through hole mounting in a PCB. When wave soldering is used, the temperature on the pins is specified to maximum 260 C for maximum 10 seconds. Maximum preheat rate of 4 C/s and temperature of max 150 C is suggested. When hands soldering care should be taken to avoid direct contact between the hot soldering iron tip and the pins for more than a few seconds in order to prevent overheating. A no-clean (NC) flux is recommended to avoid entrapment of cleaning fluids in cavities inside of the DC/DC power module. The residues may affect long time reliability and isolation voltage. Delivery package information The products are delivered in antistatic trays. Tray specifications Material 5 (7) No. Polyethylene foam, dissipative Surface resistance 105 < /square < 1012 Bake ability The trays are not bakeable Tray capacity 20 products/tray Tray height 25.4 mm [1.0 inch] Box capacity 20 products (1 full tray/box) Tray weight 100 g empty, 1400 g full maximum TechnicalReference Specification Rev EN/LZT 146 307 R4A August 2008 C (c) Ericsson Power Modules AB 25 E Ericsson Internal PRODUCT SPECIFICATION Prepared (also subject responsible if other) 6 (7) No. MICUPEZ 4/1301-BMR 637 01 Uen Approved Checked Date PKM 4000C PINB Series 2006-10-30 DC/DC converters, Input 36-75 V, Output 55 A/204 W TechnicalReference Specification 26 Rev EN/LZT 146 307 R4A August 2008 C (c) Ericsson Power Modules AB Product Qualification Specification Characteristics External visual inspection IPC-A-610 Change of temperature (Temperature cycling) IEC 60068-2-14 Na Temperature range Number of cycles Dwell/transfer time -40 to +100 C 300 30 min/0-1 min Cold (in operation) IEC 60068-2-1 Bc Temperature TA Duration -40C 2h Damp heat IEC 60068-2-3 Ca Temperature Humidity Duration +85 C 85 % RH 1000 hours Dry heat IEC 60068-2-2 Ba Temperature Duration +125 C 1000 h Heat (in operation) IEC 60068-2-1 Ad Temperature TA Duration +90 C 72 h Immersion in cleaning solvents IEC 60068-2-45 XA Method 2 Water Glycol ether Isopropanol +55 5 C +35 5 C +35 5 C Mechanical shock IEC 60068-2-27 Ea Peak acceleration Duration Pulse shape Directions Number of pulses 100 g 3 ms Half sine 6 18 (3 + 3 in each perpendicular direction) Resistance to soldering heat IEC 60068-2-20 Tb Method 1A Solder temperature Duration 260 C 10 s Robustness of terminations IEC 60068-2-21 Ua1 Tensile force 20 N for 10 s /signal pin 40 N for 10 s /power pin Solderability IEC 60068-2-54 Preconditioning Temperature, SnPb Eutectic ageing 240 h 85C /85%RH 235C Vibration, broad band random IEC 60068-2-34 Eb Frequency Spectral density Duration 10 to 500 Hz 0.025 g2/Hz 10 min in each 3 perpendicular directions