30
SWA Series 15W/30W/50W/100W/150W
Rating
Item Conditions
Rated Input Voltage
Input Voltage Range
Rated Frequency
Frequency Range
Input Current (see Note 1)
Inrush Current (see Note 1, 2)
Efficiency (typ) (see Note 1)
Rated Output Voltage
Adjustable Output Voltage Range
Rated Output Current
Adjustable Output Current Range
Maximum Output Power
Ripple (mVp-p) (see Note 1, 4)
Static Input Range 85 to 264V AC
Static Load Range 0 to 100%
Time Driftt 10min. to 8 hours
Ambient Temperature Range 0 to +50°C
Output Holdup Time (see Note 1)
Startup Time (see Note 1)
Leakage Current (see Note 1)
Switching Method, Transformer Frequency
Over Current Protection
Over Voltage Protection
Remote Sensing
Remote On/Off Control
Display
Temperature Operating Temperature
Storage Temperature
Relative Humidity Operating Humidity
Storage Humidity
Insulation Withstand Voltage Between Input and Output
(see Note 5) Between Input and Frame
Between Output and Frame
Insulation Resistance Between Input and Output
Between Input and Frame
Between Output and Frame
Vibration Resistance
Cooling Requirements
External Appearance
Size (dimensions in mm)
Weight
Safety Standards
EMI Standards
Input
Note 1: Rated input/output conditions means that the switching power supply is operated under the rated input voltage, rated frequency, rated output voltage, rated output current, and
at an ambient temperature of 25°C and 60% humidity.
Note 2: At cold start. (More current may flow at restart.)
Note 3: All output characteristics are measured at a point 5 cm from the output connector, with a 63 V 47 µF electrolytic capacitor attached at that point.
Note 4: Ripple noise is measured with a 100 MHz oscilloscope, using a 1:1 probe.
Note 5: At room temperature and normal humidity.
Output (see Note 3)Other
Additional
Functions
Environmental
Insulation
Structural
Specifications
Applicable
Standards
Constant Voltage
Accuracy
150W
SWA 150-05 SWA 150-12 SWA 150-15 SWA 150-24
100-240V AC
85 to 264V AC
50/60 Hz
47 to 63 Hz
2.4/1.2A (typ)
20/40 A (max)
79% 81% 82% 83%
+5V +12V +15V +24V
Rated voltage ±10%
30.0A 13.0A 10.0A 6.5A
0 to 100%
150.0W 156.0W 150.0W 156.0W
120mVp-p 180mVp-p 180mVp-p 240mVp-p
±3%
20ms (min)
1000/500 ms (typ)
0.5mA (max) (Vin=100VAC)/0.75mA (Vin=240VAC)
FCC topology, approx. 150 kHz (under rated input/output conditions)
Detection above 120% of rated current (output cutoff)
Over Voltage Protection Detection above approx. 115 to 145% of rated voltage
Provided
Not provided
LED operation indicator
0 to 50°C (no cover)
-25 to +85°C
30 to 90% (no condensation)
30 to 90% (no condensation)
2000 V AC for 1 minute, 2400 V AC for 1 second (Leakage current of 15 mA or less)
500 V AC for 1 minute, 600 V AC for 1 second (Leakage current of 15 mA or less)
100 MΩ(measured with 500 V DC Megger)
10 to 55 Hz, 2 G, 1 hour (in X, Y, and Z directions)
Natural air cooling
Open frame (with optional cover)
65 x 200 x 93 (W x D x H) (without cover)
900 g (open frame)
Designed to meet UL 1950
Designed to meet CSA C22.2 No. 234
Designed to meet EN 60950
Designed to meet VDE 0871 Class A (200 to 240 V AC)
Designed to meet FCC Class B (100 to 120 V AC)