Series AM10TW-IZ
10 Watt | DC-DC Converter
www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832)
F 051e R12.B 1 of 3 North America only
FEATURES:
Short Circuit & OVP Protection
Operating temperature -40oC to + 75oC
24 Pin DIP Package
Regulated output
Wide 4:1 input range
Low ripple and noise
Power modules for PCB mounting
No minimum load
Input/output Isolation voltage 1500VDC
Models
Single output
Model
Input
Voltage (V)
Output
Voltage
(V)
Output Current
max (mA)
Capacitive
Load, max(uf)
Efficiency
(%)
AM10TW-2403SIZ
9-36
3.3
2000
4200
71
AM10TW-2405SIZ
9-36
5
2000
3200
75
AM10TW-2412SIZ
9-36
12
830
600
78
AM10TW-2415SIZ
9-36
15
660
390
78
AM10TW-4803SIZ
18-75
3.3
2000
3300
73
AM10TW-4805SIZ
18-75
5
2000
2200
83
AM10TW-4812SIZ
18-75
12
830
600
81
AM10TW-4815SIZ
18-75
15
660
330
81
Models
Dual output
Model
Input
Voltage (V)
Output
Voltage
(V)
Output Current
max (mA)
Capacitive
Load, max(uf)
Ripple & Noise
max, (%)
Efficiency
(%)
AM10TW-2405DIZ
9-36
±5
±1000
±330
80
75
AM10TW-2412DIZ
9-36
±12
±410
±220
120
79
AM10TW-2415DIZ
9-36
±15
±330
±200
150
80
AM10TW-4805DIZ
18-75
±5
±1000
±330
80
77
AM10TW-4812DIZ
18-75
±12
±410
±220
120
80
AM10TW-4815DIZ
18-75
±15
±330
±200
150
80
Input Specifications
Parameters
Nominal
Typical
Maximum
Units
Voltage range
24
48
9-36
18-75
VDC
Filter
Capacitor
Absolute Maximum Rating
24 Vin
48 Vin
50
100
VDC
Permissible absolute maximum duration
100
ms
Transient Voltage Deviation
5
VDC
Isolation Specifications
Parameters
Conditions
Typical
Rated
Units
Tested I/O voltage
60 sec
1500
VDC
Resistance
> 1000
MOhm
Capacitance
470
pF
Output Specifications
Parameters
Conditions
Typical
Maximum
Units
Voltage accuracy
±2
%
Short Circuit protection
Continuous
Short Circuit restart
Auto recovery
Click on Series name for product info on aimtec.com
Series AM10TW-IZ
10 Watt | DC-DC Converter
www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832)
F 051e R12.B 2 of 3 North America only
Output Specifications (continued)
Parameters
Conditions
Typical
Maximum
Units
Over voltage protection
Zener diode clamp
>110%
VDC
Over load protection
Auto recovery
Over 110% full load
Line voltage regulation
HL-LL
±0.5
%
Load voltage regulation (Single)
0 100% full load
±0.5
%
Load voltage regulation (Dual)
0 100% full load
±2
%
Temperature coefficient
±0.05
%/oC
Ripple & Noise
3.3 & 5V models
12 & 15V models
80 mV p-p
1% Vout p-p
mV
General Specifications
Parameters
Conditions
Typical
Maximum
Units
Switching frequency
100% load
300
KHz
Operating temperature
Derating above +50 oC
-40 to +75
oC
Storage temperature
-55 to +115
oC
Case Temperature
+95
oC
Cooling
Free air convection
Humidity
95
%
Case material
Nickel coated cooper
Weight
18
g
Dimensions (L x W x H)
Tolerance ±0.02 inch, ±0.5mm
1.25 x 0.80 x 0.40 inches 31.80 x 20.30 x 10.20 mm
MTBF
> 700 000 hrs (MIL-HDBK -217F, Ground Benign, t=+25oC)
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Safety Specifications
Standards
Agency approvals
UL (pending)
Safety
EN 55022, class A
EN 55024
Pin Out Specifications Dimensions
Pin
Single
Dual
2
-V Input
-V Input
3
-V Input
-V Input
9
N.C.
Common
10
Omitted
Omitted
11
N.C.
-V Output
14
+V Output
+ V Output
15
Omitted
Omitted
16
-V Output
Common
22
+V Input
+V Input
23
+V Input
+V Input
Bottom View
22.80
(0.90)
20.30
(0.80)
2.50
(0.10)5.00
(0.20)
Printed Face
10.20
(0.40)
3.80
(0.15)
0.50
(0.02)
15.20
(0.60)
31.80
(1.25)
2 3 911
14162223
Series AM10TW-IZ
10 Watt | DC-DC Converter
www.aimtec.com Tel: +1 514 620 2722 Toll free: + 1 888 9 AIMTEC (924 6832)
F 051e R12.B 3 of 3 North America only
Derating
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
025 75
50 85
100
80
60
40
20
0
50ºC
Safe Operating Area
Free Air Convection
Ambient Temperature º C
100
-40
Output Power %
-25