www.Amprobe.com
Amprobe® Test Tools
Data Sheet
No hassle
warranty
No waiting.
No shipping
charges.
Our commitment to
high-quality products
and customer service
is demonstrated by
our industry exclusive
“No Hassle” warranty.
In the unlikely event
that an Amprobe Test
Tool requires warranty
service, any of our
local dealers are
authorized to replace
it, on the spot.
(note: $500 MSLP limit)
35XP-A
35XP-A
Digital Multimeter
Temperature measurement
Capability to 1000 °C/1832 °F
(Type K thermocouple included)
750 V AC/1000 V DC—highest
voltage rating in this class of
meter
Capacitance for motor run/start
test
0.1 μA resolution for flame
sensor testing
Frequency to 1 MHz
Resistance to 40 M W
Data Hold freezes display
Magne-Grip™ holster
VolTect™ non-contact voltage
detector
Triple safety ratings
A compact, full-featured digital multimeter for plant
maintenance, HVAC, electrical and electronic applications.
CAT
1000V
600V
300V
Amprobe® Test Tools www.Amprobe.com
Data Sheet
Function Range Accuracy
Specifications
General Specifications
35XP-A Digital Multimeter
Voltage
DC Volts
Ranges 400 mV, 4 V, 40 V, 400 V, 1000 V ± (0.5 % rdg + 1 dgt)
AC Volts (45 Hz to 500 Hz)
Ranges 400 mV (45 Hz to 100 Hz) ± (1.5 % rdg + 5 dgts)
4 V, 40 V, 400 V, 750 V ± (1.5 % rdg + 5 dgts)
Resolution 100 μV
Input Impedance 400 mV: >100 MW; 4 V: 10 MW; 40 V to 1000 V: 9.1 MW
Overload Protection 1000 V DC or 750 V AC RMS
Current
DC Current
Ranges 400 μA, 4000 μA, 40 mA, 400 mA ± (1.0 % rdg + 2 dgt)
2 A ± (2.0 % rdg + 3 dgts)
AC Current (45 Hz to 500 Hz)
Ranges 400 μA, 4000 μA, 40 mA, 400 mA ± (1.5 % rdg + 5 dgts)
2 A ± (2.5 % rdg + 5 dgts)
Resolution 0.1 μA
Input Protection 2 A/1000 V fast blow ceramic fuse 6.3 mm x 32 mm on A input
Burden Voltage 500 mV max. (2 V max. on 4 mA, 400 mA ranges)
Resistance 400 W, 4 kW, 40 kW, 400 kW, 4 MW ± (1.0 % rdg + 4 dgts)
40 MW ± (2.0 % rdg + 5 dgts)
Resolution 100 mW
Open Circuit Voltage -0.45 V DC typical, (-1.2 V DC on 400 W range)
Overload Protection 1000 V DC or 750 V AC RMS
Display 3-3/4 digit liquid crystal display (LCD) with a maximum reading of 3999
Polarity Automatic, positive implied, negative polarity indication
Overrange (OL) or (-OL) is displayed
Zero Automatic
Low Battery Indication The “M” is displayed when the battery voltage drops below the operating level
Auto Power Off Approx. 10 minutes
Measurement Rate 2 times per second, nominal
Operating Environment 0 °C to 50 °C at <70 % R.H.
Storage Temperature -20 °C to 60 °C, 0 to 80 % R.H. with battery removed from meter
Accuracy Stated accuracy at 23 °C ± 5 °C, <75 % relative humidity
Temperature Coefficient 0.1 x (specified accuracy) per °C (0 °C to 18 °C, 28 °C to 50 °C)
Altitude 2000 m
Power Single standard 9 volt battery, NEDA 1604, JIS 006P, IEC 6F22
Battery Life 150 hours typical with carbon-zinc, 300 hours typical with alkaline
Dimensions (H x W x D) 155 mm x 72 mm x 32 mm
Weight Approx. 400 g including battery
Warranty One-year
www.Amprobe.com
Data Sheet
Function Range Accuracy
Capacitance 4 nF, 40 nF, 400 nF, 4 μF ± (5.0 % rdg + 30 dgts)
40 uF, 400 uF ± (5.0 % rdg + 5 dgts)
4 mF ± (5.0 % rdg + 15 dgts)
Resolution 1 pF
Test Voltage < 1 V
Test Frequency 1.3 Hz on 4 nF to 40 μF ranges, 0.7 Hz on 400 μF, 4 mF ranges
Input Protection 2 A/1000 V fast blow ceramic fuse 6.3 mm x 32 mm on A input
Temperature 400 °C, 1000 °C, 400 °F, 1832 °F
-20 °C to 10 °C ± (2.0 % rdg + 4 °C)
10 °C to 200 °C ± (1.0 % rdg + 3 °C)
200 °C to 1000 °C ± (3.0 % rdg + 2 °C)
-4 °F to 50 °F ± (2.0 % rdg + 8 °F)
50 °F to 400 °F ± (1.0 % rdg + 6 °F)
400 °F to 1832 °F ± (3.0 % rdg + 4 °F)
Resolution 0.1 °C, 0.1 °F
Overload Protection 1000 V DC or 750 V AC RMS
1000 V 600 V 300 V
Frequency 4 k, 40 k, 400 k, 1 M ± (0.1 % rdg + 3 dgts)
Resolution 1 Hz
Sensitivity 10 Hz to 1 MHz: >2.5 V rms
Minimum Pulse Width > 25 ns
Duty Cycle Limits > 30 % and < 70 %
Overload Protection 1000 V DC or 750 V AC RMS
Continuity
Audible Indication Less than 25 W
Response Time 100 ms
Overload Protection 1000 VDC or 750 VAC rms
Diode Test
Test Current 1.2 mA (approximate) ± (1.5 % rdg + 3 dgts)
Resolution 1 mV
Open Circuit Voltage 3.0 DC typical
Overload Protection 1000 V DC or 750 V AC RMS
Non-Contact Voltage Indicator
Sense voltage 70 V to 600 V AC beeper chirps and big bright red LED comes on, works on all ranges
35XP-A Digital Multimeter
Specifications, cont.
www.Amprobe.comwww.Amprobe.com
Amprobe® Test Tools
Data Sheet
Amprobe® Test Tools
website: www.Amprobe.com
email: info@amprobe.com
Everett, WA 98203
tel: 877-AMPROBE
Amprobe® Test Tools Europe
In den Engematten 14
79286 Glottertal, Germany
Tel.: +49 (0) 7684 8009 - 0
©2007 Amprobe Test Tools. All rights reserved.
9/2007 2123441 D-US-N Rev C
Included Accessories
Pair of test leads (TL245A), K-type thermo-
couple (TP255A), temperature adapter (XR-TA),
fuse 2 A/ 1000 V (P/N FP200), 9 V battery (in-
stalled), Magne-Grip™ Holster with magnetic
hanging strap (H2-XR) and users manual.
Optional Accessories
VC30A Carrying Case
DL243D Test Lead Kit
35XP-A Digital Multimeter