Amprobe® Test Tools www.Amprobe.com
Data Sheet
Function Range Accuracy
Specifications
General Specifications
35XP-A Digital Multimeter
Voltage
DC Volts
Ranges 400 mV, 4 V, 40 V, 400 V, 1000 V ± (0.5 % rdg + 1 dgt)
AC Volts (45 Hz to 500 Hz)
Ranges 400 mV (45 Hz to 100 Hz) ± (1.5 % rdg + 5 dgts)
4 V, 40 V, 400 V, 750 V ± (1.5 % rdg + 5 dgts)
Resolution 100 μV
Input Impedance 400 mV: >100 MW; 4 V: 10 MW; 40 V to 1000 V: 9.1 MW
Overload Protection 1000 V DC or 750 V AC RMS
Current
DC Current
Ranges 400 μA, 4000 μA, 40 mA, 400 mA ± (1.0 % rdg + 2 dgt)
2 A ± (2.0 % rdg + 3 dgts)
AC Current (45 Hz to 500 Hz)
Ranges 400 μA, 4000 μA, 40 mA, 400 mA ± (1.5 % rdg + 5 dgts)
2 A ± (2.5 % rdg + 5 dgts)
Resolution 0.1 μA
Input Protection 2 A/1000 V fast blow ceramic fuse 6.3 mm x 32 mm on A input
Burden Voltage 500 mV max. (2 V max. on 4 mA, 400 mA ranges)
Resistance 400 W, 4 kW, 40 kW, 400 kW, 4 MW ± (1.0 % rdg + 4 dgts)
40 MW ± (2.0 % rdg + 5 dgts)
Resolution 100 mW
Open Circuit Voltage -0.45 V DC typical, (-1.2 V DC on 400 W range)
Overload Protection 1000 V DC or 750 V AC RMS
Display 3-3/4 digit liquid crystal display (LCD) with a maximum reading of 3999
Polarity Automatic, positive implied, negative polarity indication
Overrange (OL) or (-OL) is displayed
Zero Automatic
Low Battery Indication The “M” is displayed when the battery voltage drops below the operating level
Auto Power Off Approx. 10 minutes
Measurement Rate 2 times per second, nominal
Operating Environment 0 °C to 50 °C at <70 % R.H.
Storage Temperature -20 °C to 60 °C, 0 to 80 % R.H. with battery removed from meter
Accuracy Stated accuracy at 23 °C ± 5 °C, <75 % relative humidity
Temperature Coefficient 0.1 x (specified accuracy) per °C (0 °C to 18 °C, 28 °C to 50 °C)
Altitude 2000 m
Power Single standard 9 volt battery, NEDA 1604, JIS 006P, IEC 6F22
Battery Life 150 hours typical with carbon-zinc, 300 hours typical with alkaline
Dimensions (H x W x D) 155 mm x 72 mm x 32 mm
Weight Approx. 400 g including battery
Warranty One-year