RPE-F RPE-F SERIES Single-Phase Filter with Fuse and Inlet Socket Type for High Frequency Noise FEATURES he lineup of this series are both F01 type (one fuse) and F02 type (two fuses). T asy to maintain due to building in the fuse. (when it ship, it does not attached spare fuse.) E eakage current of standard type is 0.5 mA max and also lineup low-leakage current characteristic type is 0.01 mA max. L Faston terminal #250 (t=0.8mm). ompliant with RoHS directives. C SAFETY STANDARDS UL1283 UL File No. E62388 CSA C22.2 No.8 (cUL) File No. E62388 EN60939 certificate No. P12215989 PRODUCT IDENTIFICATION RPE 2 F N/A: Standard type L: Low-leakage current characteristic type F01 : (one fuse) / F02 : (two fuse) Rated current Number indicating the rated voltage Series name Conformity to RoHS Directive: This means that, in conformity with EU Directive 2002/95/EC, lead, cadmium, mercury, hexavalent chromium, and specific bromine-based flame retardants, PBB and PBDE, have not been used, except for exempted applications. web170321 All specifications are subject to change without notice. f_13 RPE-F CIRCUIT DIAGRAM RPE-2 F01 RPE-2 F02 1 4 1 4 2 3 2 3 RPE-2 F01L RPE-2 F02L 1 4 1 4 2 3 2 3 PANEL INSTALLATION MEASUREMENT From back side panel From front panel o3.5 M3 or o3.5 33.2 R3.5 max. 32.4 R2 max. 29.7 29 36 36 ELECTRICAL CHARACTERISTICS RPE-2 F01 L02 Part No. Rated Rated current voltage AC/DC AC/DC RPE-2003F01 RPE-2006F01 RPE-2003F02 3A 250V RPE-2006F02 6A 3A 6A Withstand voltage AC.1500V 60s [line - earth] Insulation resistance 100M min. DC.500V/ 1min Leakage current Operating temperature range With derating over -25 to +85 55 250V/60Hz Attenuation frequency range (MHz) Common mode Differential mode Weight g at 25dB at 25dB 0.5 to 10 2 to 10 70 100 max. 2 to 10 3 to 10 70 150 max. 0.5 to 10 2 to 10 70 100 max. 2 to 10 3 to 10 70 150 max. 0.5mA max. DC resistance m RPE-2 F01L/02L Part No. Rated Rated current voltage AC/DC AC/DC RPE-2003F01L RPE-2006F01L RPE-2003F02L RPE-2006F02L f_14 3A 250V 6A 3A 6A Withstand voltage AC.1500V 60s [line - earth] Insulation resistance 100M min. DC.500V/ 1min Leakage current Operating temperature range With derating over 0.01mA max. 250V/60Hz -25 to +85 55 DC resistance m Attenuation frequency range (MHz) Common mode Differential mode Weight g at 25dB at 25dB 150 max. 0.2 to 10 1 to 10 70 100 max. 0.3 to 10 2 to 10 70 150 max. 0.2 to 10 1 to 10 70 100 max. 0.3 to 10 2 to 10 70 All specifications are subject to change without notice. RPE-F DERATINGS 120 Rated current (%) 100 80 60 40 20 0 -25 -10 0 10 20 30 40 50 60 70 80 90 Ambient temperature Ta () SHAPES AND DIMENSIONS 32.10.5 0 (13.3) 27.80.5 28.50.5 36.00.5 44.00.8 o6. 2x4 o3 .2 39.51.0 13.81.0 (4.8) 31.20.5 35.00.5 34.00.5 5.4 (7.3) 58.71.5 Dimensions in mm All specifications are subject to change without notice. f_15 RPE-F ATTENUATION vs. FREQUENCY CHARACTERISTICS RPE-2003F01/02 0 -10 -10 Differential mode -20 -30 -40 Common mode -50 Differential mode -20 -30 Attenuation(dB) Attenuation(dB) RPE-2006F01/02 0 -60 -70 Common mode -40 -50 -60 -70 -80 -80 -90 -90 -100 -100 0.1 1 10 100 0.1 1 Frequency(MHz) 0 -10 -10 -20 -20 -30 -30 Common mode -50 Differential mode -60 -70 -80 -40 Common mode -50 Differential mode -60 -70 -80 -90 -90 -100 -100 0.1 1 10 Frequency(MHz) f_16 100 RPE-2006F01L/02L 0 Attenuation(dB) Attenuation(dB) RPE-2003F01L/02L -40 10 Frequency(MHz) 100 0.1 1 10 100 Frequency(MHz) All specifications are subject to change without notice.