PKL 4119A PI/PKL 4119 PI
Advanced Specification
50-60A DC/DC Power Modules
48V Input, 2.5V Output
High efficiency 88% Typ (50A) at full load
High power density, 51.7 W/in
3
, (2.5V @ 60A)
Fast dynamic response, 200µs,
+
- 200 mVpeak Typ
Low output ripple, 80 mVp-p Typ
Parallelable with no external components
Wide input voltage range (36-75V)
1,500Vdc isolation voltage
Max case temperature +100ºC
Designed to meet UL 1950 and EN 60950
The PKL series represents another one of Ericsson’s “industry
first” achievements in the continued development of our “Third
Generation” of high-density, high-efficiency power modules.
This module packs 51.7 W/in
3
at 87% efficiencies (2.5V @
60A) in an industry standard footprint that has been enhanced to
include two additional output pins for motherboard connection
reliability. These breakthrough features come from using the most
advanced patented topology utilizing integrated magnetics and
synchronous rectification on a low-resistivity multilayer PCB.
This product features fast dynamic response times and low
output ripple, which are important parameters when supplying
low-voltage logics. The PKL series also is especially suited for
limited board space and high dynamic load applications.
Ericsson’s PKL Power Module has been designed with the
converging “New Telecoms” market in mind, by specifying
the input voltage range in accordance with ETSI specifications.
The PKL series also offers over-voltage protection, under-volt-
age protection, over-temperature protection, soft-start, and is
short circuit proof.
These modules are manufactured on highly automated
manufacturing lines. Ericsson’s world-class quality commitment
is reflected in our standard five-year warranty. Ericsson
Microelectronics has been an ISO 9001 certified supplier
since 1991.
For a complete product program, please reference the back cover.
Characteristics Conditions min typ max Unit
VIInput voltage 36 75 Vdc
range
VIoff Turn-off input Ramping from 31 33 Vdc
voltage higher voltage
VIon Tur n-on input Ramping from 34 36 Vdc
voltage lower voltage
CIInput capacitance 3.5 µF
IImax Maximum input VI= VImin 125 W 5.5 A
current 150 W 6.5
PIi Input idling power IO= 0 6 W
PRC Input
stand-by power VI= 50V RC open 0.6 W
(turned off with RC)
TRIM Maximum input 6 Vdc
voltage on trim pin
General
Input TC < TCmax
Designation Function
-INPUT Negative input. Connected to base plate
CASE REMOTE Remote control (primary).
ON/OFF To turn-on and tur n-off the output
+INPUT Positive input
-OUTPUT Negative output, (two pins)
-SENSE Negative remote sense
TRIM Output voltage adjust
+SENSE Positive remote sense
+OUTPUT Positive output, (two pins)
Connections
Note: If the remote sense is not needed the -Sen should be
connected to -Out and +Sen should be connected to +Out.
Weight
100 grams
Case
Aluminum baseplate with metal standoffs.
Pins
Pin material: Copper Alloy
Pin plating: Tin/Lead over Nickel.
Mechanical Data
PKL 4119A PI/PKL 4119 PI TC= -40...+100°C, VI= 36...75 V dc unless otherwise specified.
Characteristics Conditions Device Output
min typ max Unit
VOi Output voltage initial TC= +25°C, VI= 53V, IO= IOmax All 2.45 2.50 2.55 V
setting and accuracy
Output adjust range IO= 0 to IOmax All 2.0 2.75 V
IOOutput current A
VOOutput voltage IO= 0 to IOmax All 2.38 2.63 V
tolerance band
Line regulation IO= IOmax All 5 15 mV
Load regulation VI= 53V, IO= 0 to IOmax All 5 15 mV
Vtr Load transient Load step = 0.25 x IOmax All ±200 mVpeak
voltage deviation dI/dt = 1A/µs
ttr Load transient All 200 µs
recovery time
tsStart-up time From VIconnection to VO= 0.9 x VOnom All 20 30 ms
IIim Current limit threshold VO= 0.96 VOnom @ TC<100°C A
ISC Short circuit current A
VOac Output ripple and noise IO= IOmax f<20 MHz All 80 150 mVp-p
SVR Supply voltage f<1kHz All -50 dB
rejection (ac)
OVP Over voltage protection Vin = 50V All 3.0 3.5 3.9 V
Output
Characteristics Conditions Device min typ max Unit
ηEfficiency TA= +25°C, VI= 53V, IO= IOmax %
PdPower dissipation IO= IOmax, VI= 53V W
Miscellaneous
Characteristics min max Unit
TCCase temperature -40 +100 °C
@ max output power
TSStorage temperature -40 +125 °C
VIContinuous input voltage -0.5 +80 Vdc
VISO Isolation voltage 1,500 Vdc
(input to output test voltage)
VRC Remote control voltage 12 Vdc
I2t Inrush transient 1 A2s
Absolute Maximum Ratings
Stress in excess of Absolute Maximum Ratings may cause permanent damage. Absolute Maximum Ratings, sometimes referred to as “no destruction limits,” are normally tested with one parameter
at a time exceeding the limits of output data or electrical characteristics. If exposed to stress above these limits, function and performance may degrade in an unspecified manner.
PKL 4119A PI
PKL 4119 PI 060
050
PKL 4119A PI
PKL 4119 PI 61 64.5 72
51 54.5 62
PKL 4119A PI
PKL 4119 PI 65 79
55 69
PKL 4119A PI
PKL 4119 PI
PKL 4119A PI
PKL 4119 PI
20.5
15.4
88
89
Ericsson Microelectronics’ Sales Offices:
Brazil: Phone: +55 11 681 0040 Fax: +55 11 681 2051
Denmark: Phone: +45 33 883 109 Fax: +45 33 883 105
Finland: Phone: +358 9 299 4098 Fax: +358 9 299 4188
France: Phone: +33 1 4083 7720 Fax: +33 1 4083 7741
Germany: Phone: +49 211 534 1516 Fax: +49 211 534 1525
Great Britain: Phone: +44 1793 488 300 Fax: +44 1793 488 301
Hong Kong: Phone: +852 2590 2356 Fax: +852 2590 7152
Italy: Phone: +39 2 7014 4203 Fax: +39 2 7014 4260
Japan: Phone: +81 3 5216 9091 Fax: +81 3 5216 9096
Norway: Phone: +47 66 841 906 Fax: +47 66 841 909
Russia: Phone: +7 095 247 6211 Fax: +7 095 247 6212
Spain: Phone: +34 91 339 1858 Fax: +34 91 339 3145
Sweden: Phone: +46 8 721 6258 Fax: +46 8 721 7001
United States: Phone: +1 877 374 2642 Fax: +1 972 583 8355
Ericsson Inc.
Microelectronics
701 North Glenville Drive
Richardson, Texas 75081
Phone: 877-ERICMIC
www.ericsson.com/micro
Information given in this data sheet is believed
to be accurate and reliable. No responsibility is
assumed for the consequences of its use nor for
any infringement of patents or other rights of
third parties which may result from its use. No
license is granted by implication or otherwise
under any patent or patent rights of Ericsson
Inc. These products are sold only according to
Ericsson Inc.’s general conditions of sale, unless
otherwise confirmed in writing.
The contents of this document are subject
to revision without notice due to continued
progress in design and manufacturing.
Advanced Specification
AE/LZT 108 3973 R1
© Ericsson Inc., April 2000
VIVO/IOPOmax Ordering Number
48/60 V 2.5V/60A 150W PKL 4119A PI
48/60 V 2.5V/50A 125W PKL 4119 PI
Product Program
The PKL 4000 DC/DC power modules will be available with the different
options listed in the Product Options table.
Please check with the factory for availability.
Option Suffix Example
Product Options
Negative remote on/off logic
Ericsson Unique Trim,
(i.e. Vout Adjust)
Positive remote on/off logic
Lead length of 0.145" ± 0.010"
P
LA
PKL 4119A PI
PKL 4119A PIP
PKL 4119A PILA