M41ST85W 3.0/3.3 V I2C combination serial RTC, NVRAM supervisor and microprocessor supervisor Features SNAPHAT battery & crystal Automatic battery switchover and WRITE protect for: - Internal serial RTC and - External low power SRAM (LPSRAM) 400 kHz I2C serial interface 3.0/3.3 V operating voltage - VCC = 2.7 to 3.6 V Ultralow battery supply current of 500 nA (max) RoHS compliant - Lead-free second level interconnect 28 1 SOH28 Embedded crystal Serial RTC features SOX28 400 kHz I2C 44 bytes of general purpose NVRAM Counters for: - Seconds, minutes, hours, day, date, month, and year - Century - Tenths/hundredths of seconds - Clock calibration register allows compensation for crystal variations over temperature Programmable alarm with repeat modes - Functions in battery back-up mode Power-down timestamp (HT bit) 2.5 to 5.5 V oscillator operating voltage Power-on reset/low voltage detect - Open drain reset output - Reset voltage, VPFD = 2.60 V (nom) - Two reset input pins - Watchdog can be steered to reset output NVRAM supervisor features Non-volatizes external LPSRAM - Automatically switches to back-up battery and deselects (write-protects) external LPSRAM via chip-enable gate - Power-fail deselect (write protect) voltage, VPFD = 2.60 V (nom) - Switchover, VSO = 2.50 V (nom) Battery monitor (battery low flag) Microprocessor supervisor features Other features Programmable watchdog - 62.5 ms to 128 s time-out period Early power-fail warning circuit (PFI/PFO) with 1.25 V precision reference October 2011 Programmable squarewave generator (1 Hz to 32 KHz) -40C to +85C operation Package options: - 28-lead SNAPHAT(R) IC (SOH28) SNAPHAT battery/crystal top to be ordered separately - 28-lead embedded crystal SOIC (SOX28) Doc ID 7531 Rev 11 1/43 www.st.com 1 Contents M41ST85W Contents 1 Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 2 Operating modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 2.1 3 2-wire bus characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 2.1.1 Bus not busy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 2.1.2 Start data transfer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 2.1.3 Stop data transfer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 2.1.4 Data valid . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 2.1.5 Acknowledge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 2.2 Read mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 2.3 Write mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 2.4 Data retention mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Clock operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 3.1 Power-down time-stamp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 3.2 TIMEKEEPER(R) registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 3.3 Calibrating the clock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 3.4 Setting alarm clock registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 3.5 Watchdog timer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 3.6 Square wave output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 3.7 Power-on reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 3.8 Reset inputs (RSTIN1 & RSTIN2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 3.9 Power-fail input/output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 3.10 Century bit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 3.11 Output driver pin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 3.12 Battery low warning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 3.13 trec bit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 3.14 Initial power-on defaults . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 4 Maximum ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 5 DC and AC parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 2/43 Doc ID 7531 M41ST85W Contents 6 Package mechanical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 7 Part numbering . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 8 Environmental information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 9 Revision history . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 Doc ID 7531 3/43 List of tables M41ST85W List of tables Table 1. Table 2. Table 3. Table 4. Table 5. Table 6. Table 7. Table 8. Table 9. Table 10. Table 11. Table 12. Table 13. Table 14. Table 15. Table 16. Table 17. Table 18. Table 19. Table 20. Table 21. Table 22. 4/43 Signal names . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 TIMEKEEPER(R) register map . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Alarm repeat modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Square wave output frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Reset AC characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 trec definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Default values . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Absolute maximum ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 DC and AC measurement conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Capacitance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 DC characteristics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 AC characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 Power down/up AC characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 SOH28 - 28-lead plastic small outline, battery SNAPHAT(R), package mechanical data . . 34 4-pin SNAPHAT(R) housing for 48 mAh battery & crystal, mechanical data. . . . . . . . . . . . . 35 4-pin SNAPHAT(R) housing for 120 mAh battery & crystal, mechanical data. . . . . . . . . . . . 36 SOX28 - 28-lead plastic small outline, 300 mils, embedded crystal, mechanical data . . . 37 Carrier tape dimensions for SOH28 and SOX28 packages . . . . . . . . . . . . . . . . . . . . . . . . 38 Reel dimensions for 24 mm carrier tape (SOH28 and SOX28 packages) . . . . . . . . . . . . . 39 Ordering information scheme . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 SNAPHAT(R) battery/crystal table. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 Document revision history . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 Doc ID 7531 M41ST85W List of figures List of figures Figure 1. Figure 2. Figure 3. Figure 4. Figure 5. Figure 6. Figure 7. Figure 8. Figure 9. Figure 10. Figure 11. Figure 12. Figure 13. Figure 14. Figure 15. Figure 16. Figure 17. Figure 18. Figure 19. Figure 20. Figure 21. Figure 22. Figure 23. Figure 24. Figure 25. Figure 26. Figure 27. Logic diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 28-pin SOIC connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 28-pin, 300 mil SOIC connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Block diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Hardware hookup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Serial bus data transfer sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Acknowledgement sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Write cycle timing: RTC & external SRAM control signals . . . . . . . . . . . . . . . . . . . . . . . . . 14 Slave address location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Read mode sequence. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Alternate read mode sequence. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Write mode sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Crystal accuracy across temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Calibration waveform . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Alarm interrupt reset waveform. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Backup mode alarm waveform . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 RSTIN1 & RSTIN2 timing waveforms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 AC testing input/output waveforms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Bus timing requirements sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 Power down/up mode AC waveforms. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 SOH28 - 28-lead plastic small outline, battery SNAPHAT(R), package outline . . . . . . . . . . 34 4-pin SNAPHAT(R) housing for 48 mAh battery & crystal, package outline . . . . . . . . . . . . . 35 4-pin SNAPHAT(R) housing for 120 mAh battery & crystal, package outline . . . . . . . . . . . . 36 SOX28 - 28-lead plastic small outline, 300 mils, embedded crystal, package outline . . . . 37 Carrier tape for SOH28 and SOX28 package. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 Reel schematic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 Recycling symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 Doc ID 7531 5/43 Description 1 M41ST85W Description The M41ST85W is a combination serial real-time clock, microprocessor supervisor, and NVRAM supervisor. It is built in a low-power CMOS SRAM process and has a 64-byte memory space with 44 bytes of NVRAM and 20 memory-mapped RTC registers (see Table 2 on page 20). The RTC registers are configured in binary coded decimal (BCD) format. The M41ST85W combines a 400 kHz I2C serial RTC with an automatic backup battery switchover circuit for powering an external LPSRAM as well as the internal RTC. When power begins to fail, the switchover automatically connects to the backup battery to keep the RTC and external LPSRAM alive in the absence of system power. Access to the LPSRAM is also cut off via a chip-enable gate function, thereby write-protecting the memory. A programmable watchdog and power-on reset/low voltage detect function are the key elements in the microprocessor supervisor section. The real-time clock includes a built-in 32.768 kHz oscillator (crystal-controlled), which provides the time base for the timekeeping and calendar functions. Eight of the 20 clock registers provide the basic clock/calendar functions while the other 12 bytes provide status/control for the alarm, watchdog, and squarewave functions. RTC addresses and data are transferred serially via the two-line, bidirectional I2C interface. The built-in address register is incremented automatically after each WRITE or READ data byte. The M41ST85W has a built-in power sense circuit which detects power failures and automatically switches to the backup battery when a power failure occurs. During an outage, the power to sustain the SRAM and clock operations is typically supplied by a small lithium button-cell battery as is the case when using the SNAPHAT(R) package option. Functions available to the user include a non-volatile, time-of-day clock/calendar, alarm interrupts, watchdog timer, and programmable squarewave generator. Other features include a power-on reset as well as two additional debounce reset inputs (RSTIN1 and RSTIN2) which can also generate an output reset (RST). The eight registers for basic clock/calendar functions contain the century, year, month, date, day, hour, minute, second, and tenths/hundredths of a second in 24-hour BCD format. Corrections for 28, 29 (leap year - valid until year 2100), 30 and 31 day months are made automatically. The M41ST85W is offered in two 28-lead SOIC packages. The 300 mil SOH28 SNAPHAT(R) IC package mates with ST's SNAPHAT battery/crystal top (ordered separately). SNAPHAT battery options include 48 mAh and 120 mAh. ST's 300 mil SOX28 embedded crystal IC includes the 32 KHz crystal and is perfect for applications where a low profile is a must. The SOH28 SNAPHAT SOIC includes sockets with gold plated contacts at both ends for direct connection to the SNAPHAT top. The SNAPHAT battery/crystal top is inserted atop the IC package after the completion of the surface mount assembly process which avoids potential battery and crystal damage due to the high temperatures required for device surface-mounting. The unique design allows the battery to be replaced, thus extending the life of the RTC and NVRAM indefinitely. The SNAPHAT top is keyed to prevent reverse insertion. The SNAPHAT IC and SNAPHAT tops are shipped separately. The ICs are available in plastic anti-static tubes or in tape & reel form. The SNAPHAT tops are shipped in plastic anti-static tubes. The part numbers are 6/43 Doc ID 7531 Rev 11 M41ST85W Description M4T28-BR12SH1 (48 mAh) and M4T32-BR12SH1 (120 mAh). For the extended temperature requirement, the 120 mAh M4T32-BR12SH6 is available. For more information, see Table 21 on page 40. Caution: Do not place the SNAPHAT(R) battery/crystal top in conductive foam, as this will drain the lithium button-cell battery. The 300 mil SOX embedded crystal SOIC typically requires a user-supplied battery for nonvolatile operation. Capacitor backup can also be implemented with this package. Figure 1. Logic diagram VCC VBAT(1) SCL ECON SDA RST EX IRQ/FT/OUT RSTIN1 M41ST85W SQW RSTIN2 PFO WDI VOUT PFI VSS AI03658 1. For 28-pin, 300 mil embedded crystal SOIC only. Doc ID 7531 Rev 11 7/43 Description M41ST85W Table 1. Signal names ECON Conditioned chip enable output EX External chip enable IRQ/FT/OUT Interrupt/frequency test/out output (open drain) PFI Power fail input PFO Power fail output RST Reset output (open drain) RSTIN1 Reset 1 Input RSTIN2 Reset 2 Input SCL Serial clock input SDA Serial data input/output SQW Square wave output WDI Watchdog input VCC Supply voltage VOUT Voltage output VSS Ground VBAT (1) Battery supply voltage NC No connect NF No function 1. For 28-pin, 300 mil embedded crystal SOIC only. Figure 2. 28-pin SOIC connections SQW NC NC NC NC NC NC WDI RSTIN1 RSTIN2 NC NC PFO VSS 28 1 2 27 3 26 4 25 5 24 6 23 7 22 M41ST85W 8 21 9 20 10 19 11 18 12 17 13 16 14 15 AI03659 8/43 Doc ID 7531 Rev 11 VCC EX IRQ/FT/OUT VOUT NC NC PFI NC SCL NC RST NC SDA ECON M41ST85W Description Figure 3. 28-pin, 300 mil SOIC connections NF NF NF NF NC NC NC SQW WDI RSTIN1 RSTIN2 PFO NC VSS 28 1 2 27 3 26 4 25 5 24 6 23 7 22 M41ST85W 8 21 9 20 10 19 11 18 12 17 13 16 14 15 VCC EX IRQ/FT/OUT VOUT NC PFI SCL NC NC RST NC SDA ECON VBAT AI06370d Note: No function (NF) pins should be tied to VSS. Pins 1, 2, 3, and 4 are internally shorted together. Doc ID 7531 Rev 11 9/43 Description Figure 4. M41ST85W Block diagram REAL TIME CLOCK CALENDAR SDA 44 BYTES USER RAM I2C INTERFACE RTC w/ALARM & CALIBRATION SCL (2) Crystal WATCHDOG 32KHz OSCILLATOR SQUARE WAVE WDI VCC AFE WDS IRQ/FT/OUT(1) SQW VOUT VBAT VBL= 2.5V COMPARE VSO = 2.5V COMPARE VPFD = 2.65V COMPARE BL POR RST(1) RSTIN1 RSTIN2 ECON EX PFI COMPARE PFO 1.25V (Internal) AI03932 1. Open drain output. 2. Crystal integrated into SOIC package for MX package option. 10/43 Doc ID 7531 Rev 11 M41ST85W Figure 5. Description Hardware hookup M41ST85W Regulator Unregulated Voltage VIN VCC VCC VOUT VCC ECON E EX LPSRAM From MCU SCL R1 SDA WDI Pushbutton Reset RSTIN1 RST RSTIN2 SQW To RST To LED Display PFO To NMI (1) IRQ/FT/OUT VBAT To INT PFI R2 VSS AI03660 1. Required for embedded crystal (MX) package only. Doc ID 7531 Rev 11 11/43 Operating modes 2 M41ST85W Operating modes The M41ST85W clock operates as a slave device on the serial bus. Access is obtained by implementing a start condition followed by the correct slave address (D0h). The 64 bytes contained in the device can then be accessed sequentially in the following order: 1. Tenths/hundredths of a second register 2. Seconds register 3. Minutes register 4. Century/hours register 5. Day register 6. Date register 7. Month register 8. Year register 9. Control register 10. Watchdog register 11 - 16. Alarm registers 17 - 19. Reserved 20. Square wave register 21 - 64. User RAM The M41ST85W clock continually monitors VCC for an out-of-tolerance condition. Should VCC fall below VPFD, the device terminates an access in progress and resets the device address counter. Inputs to the device will not be recognized at this time to prevent erroneous data from being written to the device from a an out-of-tolerance system. When VCC falls below VSO, the device automatically switches over to the battery and powers down into an ultralow current mode of operation to conserve battery life. As system power returns and VCC rises above VSO, the battery is disconnected, and the power supply is switched to external VCC. Write protection continues until VCC reaches VPFD(min) plus trec (min). For more information on battery storage life refer to application note AN1012. 2.1 2-wire bus characteristics The bus is intended for communication between different ICs. It consists of two lines: a bidirectional data signal (SDA) and a clock signal (SCL). Both the SDA and SCL lines must be connected to a positive supply voltage via a pull-up resistor. The following protocol has been defined: 12/43 Data transfer may be initiated only when the bus is not busy. During data transfer, the data line must remain stable whenever the clock line is high. Changes in the data line, while the clock line is high, will be interpreted as control signals. Doc ID 7531 Rev 11 M41ST85W Operating modes Accordingly, the following bus conditions have been defined: 2.1.1 Bus not busy Both data and clock lines remain high. 2.1.2 Start data transfer A change in the state of the data line, from high to low, while the clock is high, defines the START condition. 2.1.3 Stop data transfer A change in the state of the data line, from low to high, while the clock is high, defines the STOP condition. 2.1.4 Data valid The state of the data line represents valid data when after a start condition, the data line is stable for the duration of the high period of the clock signal. The data on the line may be changed during the low period of the clock signal. There is one clock pulse per bit of data. Each data transfer is initiated with a start condition and terminated with a stop condition. The number of data bytes transferred between the start and stop conditions is not limited. The information is transmitted byte-wide and each receiver acknowledges with a ninth bit. By definition a device that gives out a message is called "transmitter," the receiving device that gets the message is called "receiver." The device that controls the message is called "master." The devices that are controlled by the master are called "slaves." 2.1.5 Acknowledge Each byte of eight bits is followed by one acknowledge bit. This acknowledge bit is a low level put on the bus by the receiver whereas the master generates an extra acknowledge related clock pulse. A slave receiver which is addressed is obliged to generate an acknowledge after the reception of each byte that has been clocked out of the slave transmitter. The device that acknowledges has to pull down the SDA line during the acknowledge clock pulse in such a way that the SDA line is a stable low during the high period of the acknowledge related clock pulse. Of course, setup and hold times must be taken into account. A master receiver must signal an end of data to the slave transmitter by not generating an acknowledge on the last byte that has been clocked out of the slave. In this case the transmitter must leave the data line high to enable the master to generate the STOP condition. Doc ID 7531 Rev 11 13/43 Operating modes Figure 6. M41ST85W Serial bus data transfer sequence DATA LINE STABLE DATA VALID CLOCK DATA START CONDITION CHANGE OF DATA ALLOWED STOP CONDITION AI00587 Figure 7. Acknowledgement sequence CLOCK PULSE FOR ACKNOWLEDGEMENT START SCL FROM MASTER DATA OUTPUT BY TRANSMITTER 1 2 8 MSB 9 LSB DATA OUTPUT BY RECEIVER AI00601 Figure 8. Write cycle timing: RTC & external SRAM control signals EX tEXPD tEXPD ECON AI03663 14/43 Doc ID 7531 Rev 11 M41ST85W 2.2 Operating modes Read mode In this mode the master reads the M41ST85W slave after setting the slave address (see Figure 9). Following the WRITE mode control bit (R/W=0) and the acknowledge bit, the word address 'An' is written to the on-chip address pointer. Next the START condition and slave address are repeated followed by the READ mode control bit (R/W=1). At this point the master transmitter becomes the master receiver. The data byte which was addressed will be transmitted and the master receiver will send an acknowledge bit to the slave transmitter (see Figure 10 on page 16). The address pointer is only incremented on reception of an acknowledge clock. The M41ST85W slave transmitter will now place the data byte at address An+1 on the bus, the master receiver reads and acknowledges the new byte and the address pointer is incremented to An+2. This cycle of reading consecutive addresses will continue until the master receiver sends a STOP condition to the slave transmitter. The system-to-user transfer of clock data will be halted whenever the address being read is a clock address (00h to 07h). The update will resume either due to a stop condition or when the pointer increments to a non-clock or RAM address. This is true both in READ mode and WRITE mode. An alternate READ mode may also be implemented whereby the master reads the M41ST85W slave without first writing to the (volatile) address pointer. The first address that is read is the last one stored in the pointer (see Figure 11 on page 16). Slave address location R/W SLAVE ADDRESS START 1 A LSB Figure 9. MSB Note: 1 0 1 0 0 0 AI00602 Doc ID 7531 Rev 11 15/43 Operating modes M41ST85W SLAVE ADDRESS DATA n+1 ACK DATA n ACK S ACK BUS ACTIVITY: R/W START WORD ADDRESS (An) ACK S R/W SDA LINE ACK BUS ACTIVITY: MASTER START Figure 10. Read mode sequence STOP SLAVE ADDRESS DATA n+X P NO ACK AI00899 STOP R/W SLAVE ADDRESS 16/43 DATA n+X P NO ACK BUS ACTIVITY: DATA n+1 ACK DATA n ACK S ACK SDA LINE ACK BUS ACTIVITY: MASTER START Figure 11. Alternate read mode sequence AI00895 Doc ID 7531 Rev 11 M41ST85W 2.3 Operating modes Write mode In this mode the master transmitter transmits to the M41ST85W slave receiver. Bus protocol is shown in Figure 12. Following the START condition and slave address, a logic '0' (R/W=0) is placed on the bus and indicates to the addressed device that word address An will follow and is to be written to the on-chip address pointer. The data word to be written to the memory is strobed in next and the internal address pointer is incremented to the next memory location within the RAM on the reception of an acknowledge clock. The M41ST85W slave receiver will send an acknowledge clock to the master transmitter after it has received the slave address and again after it has received the word address and each data byte. STOP SLAVE ADDRESS 2.4 DATA n+X P ACK DATA n+1 ACK BUS ACTIVITY: DATA n ACK WORD ADDRESS (An) ACK S R/W SDA LINE ACK BUS ACTIVITY: MASTER START Figure 12. Write mode sequence AI00591 Data retention mode With valid VCC applied, the M41ST85W can be accessed as described above with READ or WRITE cycles. Should the supply voltage decay, the M41ST85W will automatically deselect, write protecting itself (and any external SRAM) when VCC falls between VPFD(max) and VPFD(min). This is accomplished by internally inhibiting access to the clock registers. At this time, the reset pin (RST) is driven active and will remain active until VCC returns to nominal levels. External RAM access is inhibited in a similar manner by forcing ECON to a high level. This level is within 0.2 volts of the VBAT. ECON will remain at this level as long as VCC remains at an out-of-tolerance condition. When VCC falls below the battery backup switchover voltage (VSO), power input is switched from the VCC pin to the SNAPHAT(R) battery, and the clock registers and external SRAM are maintained from the attached battery supply. All outputs become high impedance. The VOUT pin is capable of supplying 100 A of current to the attached memory with less than 0.3 volts drop under this condition. On power-up, when VCC returns to a nominal value, write protection continues for trec by inhibiting ECON. The RST signal also remains active during this time (see Figure 20 on page 33). Note: Most low power SRAMs on the market today can be used with the M41ST85W RTC SUPERVISOR. There are, however some criteria which should be used in making the final choice of an SRAM to use. The SRAM must be designed in a way where the chip enable input disables all other inputs to the SRAM. This allows inputs to the M41ST85W and SRAMs to be "Don't Care" once VCC falls below VPFD(min). The SRAM should also guarantee data retention down to VCC = 2.0 volts. The chip enable access time must be sufficient to meet the system needs with the chip enable output propagation delays included. If the SRAM includes a second chip enable pin (E2), this pin should be tied to VOUT. Doc ID 7531 Rev 11 17/43 Operating modes M41ST85W If data retention lifetime is a critical parameter for the system, it is important to review the data retention current specifications for the particular SRAMs being evaluated. Most SRAMs specify a data retention current at 3.0 volts. Manufacturers generally specify a typical condition for room temperature along with a worst case condition (generally at elevated temperatures). The system level requirements will determine the choice of which value to use. The data retention current value of the SRAMs can then be added to the IBAT value of the M41ST85W to determine the total current requirements for data retention. The available battery capacity for the SNAPHAT(R) top of your choice can then be divided by this current to determine the amount of data retention available (see Table 21 on page 40). For a further more detailed review of lifetime calculations, please see application note AN1012. 18/43 Doc ID 7531 Rev 11 M41ST85W 3 Clock operation Clock operation The eight byte clock register (see Table 2 on page 20) is used to both set the clock and to read the date and time from the clock, in a binary coded decimal format. Tenths/hundredths of seconds, seconds, minutes, and hours are contained within the first four registers. Note: A WRITE to any clock register will result in the tenths/hundredths of seconds being reset to "00," and tenths/hundredths of seconds cannot be written to any value other than "00." Bits D6 and D7 of clock register 03h (century/hours register) contain the CENTURY ENABLE bit (CEB) and the CENTURY bit (CB). Setting CEB to a '1' will cause CB to toggle, either from '0' to '1' or from '1' to '0' at the turn of the century (depending upon its initial state). If CEB is set to a '0,' CB will not toggle. Bits D0 through D2 of register 04h contain the day (day of week). Registers 05h, 06h, and 07h contain the date (day of month), month and years. The ninth clock register is the control register (this is described in the clock calibration section). Bit D7 of register 01h contains the STOP bit (ST). Setting this bit to a '1' will cause the oscillator to stop. If the device is expected to spend a significant amount of time on the shelf, the oscillator may be stopped to reduce current drain. When reset to a '0' the oscillator restarts within one second. The eight clock registers may be read one byte at a time, or in a sequential block. The control register (address location 08h) may be accessed independently. Provision has been made to assure that a clock update does not occur while any of the eight clock addresses are being read. If a clock address is being read, an update of the clock registers will be halted. This will prevent a transition of data during the READ. 3.1 Power-down time-stamp When a power failure occurs, the halt update bit (HT) will automatically be set to a '1.' This will prevent the clock from updating the TIMEKEEPER(R) registers, and will allow the user to read the exact time of the power-down event. Resetting the HT bit to a '0' will allow the clock to update the TIMEKEEPER registers with the current time. For more information, see application note AN1572. 3.2 TIMEKEEPER(R) registers The M41ST85W offers 20 internal registers which contain clock, alarm, watchdog, flag, square wave and control data. These registers are memory locations which contain external (user accessible) and internal copies of the data (usually referred to as BiPORTTM TIMEKEEPER cells). The external copies are independent of internal functions except that they are updated periodically by the simultaneous transfer of the incremented internal copy. The internal divider (or clock) chain will be reset upon the completion of a WRITE to any clock address. The system-to-user transfer of clock data will be halted whenever the address being read is a clock address (00h to 07h). The update will resume either due to a stop condition or when the pointer increments to a non-clock or RAM address. TIMEKEEPER and alarm registers store data in BCD. control, watchdog and square wave registers store data in binary format. Doc ID 7531 Rev 11 19/43 Clock operation M41ST85W TIMEKEEPER(R) register map Table 2. Data Function/range Address D7 D6 00h D5 D4 D3 D2 0.1 seconds D1 BCD format D0 0.01 seconds Seconds 00-99 01h ST 10 seconds Seconds Seconds 00-59 02h 0 10 minutes Minutes Minutes 00-59 03h CEB CB Hours (24-hour format) Century/hours 0-1/00-23 04h TR 0 Day 01-7 05h 0 0 Date: day of month Date 01-31 06h 0 0 Month Month 01-12 Year Year 00-99 07h 10 hours 0 0 0 10 date 0 Day of week 10M 10 years 08h OUT FT S 09h WDS BMB4 BMB3 BMB2 0Ah AFE SQWE ABE Al 10M 0Bh RPT4 RPT5 0Ch RPT3 HT 0Dh RPT2 0Eh RPT1 0Fh WDF AF 0 BL 0 0 0 0 Flags 10h 0 0 0 0 0 0 0 0 Reserved 11h 0 0 0 0 0 0 0 0 Reserved 12h 0 0 0 0 0 0 0 0 Reserved 13h RS3 RS2 RS1 RS0 0 0 0 0 SQW Keys: 20/43 Calibration BMB1 BMB0 Control RB1 RB0 Watchdog Alarm month Al month 01-12 AI 10 date Alarm date Al date 01-31 AI 10 hour Alarm hour Al hour 00-23 Alarm 10 minutes Alarm minutes Al min 00-59 Alarm 10 seconds Alarm seconds Al sec 00-59 S = Sign bit RB0-RB1 = Watchdog resolution bits FT = Frequency test bit WDS = Watchdog steering bit ST = Stop bit ABE = Alarm in battery backup mode enable bit 0 = Must be set to zero RPT1-RPT5 = Alarm repeat mode bits BL = Battery low flag (read only) WDF = Watchdog flag (read only) BMB0-BMB4 = Watchdog multiplier bits AF = Alarm flag (read only) CEB = Century enable bit SQWE = Square wave enable CB = Century bit RS0-RS3 = SQW frequency OUT = Output level HT = Halt update bit AFE = Alarm flag enable flag TR = trec bit Doc ID 7531 Rev 11 M41ST85W 3.3 Clock operation Calibrating the clock The M41ST85W is driven by a quartz controlled oscillator with a nominal frequency of 32,768 Hz. The devices are tested not exceed +/-35 ppm (parts per million) oscillator frequency error at 25oC, which equates to about +/-1.53 minutes per month. When the Calibration circuit is properly employed, accuracy improves to better than 2 ppm at 25C. The oscillation rate of crystals changes with temperature (see Figure 13 on page 22). Therefore, the M41ST85W design employs periodic counter correction. The calibration circuit adds or subtracts counts from the oscillator divider circuit at the divide by 256 stage, as shown in Figure 14 on page 22. The number of times pulses which are blanked (subtracted, negative calibration) or split (added, positive calibration) depends upon the value loaded into the five calibration bits found in the control register. Adding counts speeds the clock up, subtracting counts slows the clock down. The calibration bits occupy the five lower order bits (D4-D0) in the control register (08h). These bits can be set to represent any value between 0 and 31 in binary form. Bit D5 is a sign bit; '1' indicates positive calibration, '0' indicates negative calibration. Calibration occurs within a 64 minute cycle. The first 62 minutes in the cycle may, once per minute, have one second either shortened by 128 or lengthened by 256 oscillator cycles. If a binary '1' is loaded into the register, only the first 2 minutes in the 64 minute cycle will be modified; if a binary 6 is loaded, the first 12 will be affected, and so on. Therefore, each calibration step has the effect of adding 512 or subtracting 256 oscillator cycles for every 125,829,120 actual oscillator cycles, that is +4.068 or -2.034 ppm of adjustment per calibration step in the calibration register. Assuming that the oscillator is running at exactly 32,768 Hz, each of the 31 increments in the calibration byte would represent +10.7 or -5.35 seconds per month which corresponds to a total range of +5.5 or -2.75 minutes per month. Two methods are available for ascertaining how much calibration a given M41ST85W may require. The first involves setting the clock, letting it run for a month and comparing it to a known accurate reference and recording deviation over a fixed period of time. Calibration values, including the number of seconds lost or gained in a given period, can be found in application note AN934, "TIMEKEEPER(R) calibration." This allows the designer to give the end user the ability to calibrate the clock as the environment requires, even if the final product is packaged in a non-user serviceable enclosure. The designer could provide a simple utility that accesses the calibration byte. The second approach is better suited to a manufacturing environment, and involves the use of the IRQ/FT/OUT pin. The pin will toggle at 512 Hz, when the stop bit (ST, D7 of 01h) is '0,' the frequency test bit (FT, D6 of 08h) is '1,' the alarm flag enable bit (AFE, D7 of 0Ah) is '0,' and the watchdog steering bit (WDS, D7 of 09h) is '1' or the watchdog register (09h = 0) is reset. Any deviation from 512 Hz indicates the degree and direction of oscillator frequency shift at the test temperature. For example, a reading of 512.010124 Hz would indicate a +20 ppm oscillator frequency error, requiring a -10 (XX001010) to be loaded into the calibration byte for correction. Note that setting or changing the calibration byte does not affect the frequency test output frequency. The IRQ/FT/OUT pin is an open drain output which requires a pull-up resistor to VCC for proper operation. A 500 to 10 k resistor is recommended in order to control the rise time. The FT bit is cleared on power-down. Doc ID 7531 Rev 11 21/43 Clock operation M41ST85W Figure 13. Crystal accuracy across temperature Frequency (ppm) 20 0 -20 -40 -60 F = K x (T - T )2 O F -80 2 2 K = -0.036 ppm/C 0.006 ppm/C -100 TO = 25C 5C -120 -140 -160 -40 -30 -20 -10 0 10 20 30 40 50 60 70 80 Temperature C AI07888 Figure 14. Calibration waveform NORMAL POSITIVE CALIBRATION NEGATIVE CALIBRATION AI00594B 22/43 Doc ID 7531 Rev 11 M41ST85W 3.4 Clock operation Setting alarm clock registers Address locations 0Ah-0Eh contain the alarm settings. The alarm can be configured to go off at a prescribed time on a specific month, date, hour, minute, or second, or repeat every year, month, day, hour, minute, or second. It can also be programmed to go off while the M41ST85W is in the battery backup to serve as a system wake-up call. Bits RPT5-RPT1 put the alarm in the repeat mode of operation. Table 3 shows the possible configurations. Codes not listed in the table default to the once per second mode to quickly alert the user of an incorrect alarm setting. When the clock information matches the alarm clock settings based on the match criteria defined by RPT5-RPT1, the AF (alarm flag) is set. If AFE (alarm flag enable) is also set, the alarm condition activates the IRQ/FT/OUT pin as shown in Figure 15. To disable alarm, write '0' to the alarm date register and to RPT5-RPT1. Note: If the address pointer is allowed to increment to the flag register address, an alarm condition will not cause the interrupt/flag to occur until the address pointer is moved to a different address. It should also be noted that if the last address written is the "Alarm Seconds," the address pointer will increment to the flag address, causing this situation to occur. The IRQ/FT/OUT output is cleared by a READ to the flags register. A subsequent READ of the flags register is necessary to see that the value of the alarm flag has been reset to '0.' The IRQ/FT/OUT pin can also be activated in the battery backup mode. The IRQ/FT/OUT will go low if an alarm occurs and both ABE (alarm in battery backup mode enable) and AFE are set. The ABE and AFE bits are reset during power-up, therefore an alarm generated during power-up will only set AF. The user can read the flag register at system boot-up to determine if an alarm was generated while the M41ST85W was in the deselect mode during power-up. Figure 16 on page 24 illustrates the backup mode alarm timing. Figure 15. Alarm interrupt reset waveform 0Eh 0Fh 10h ACTIVE FLAG HIGH-Z IRQ/FT/OUT AI03664 Table 3. Alarm repeat modes RPT5 RPT4 RPT3 RPT2 RPT1 Alarm setting 1 1 1 1 1 Once per second 1 1 1 1 0 Once per minute 1 1 1 0 0 Once per hour 1 1 0 0 0 Once per day 1 0 0 0 0 Once per month 0 0 0 0 0 Once per year Doc ID 7531 Rev 11 23/43 Clock operation M41ST85W Figure 16. Backup mode alarm waveform VCC VPFD VSO trec ABE, AFE Bits in Interrupt Register AF bit in Flags Register IRQ/FT/OUT HIGH-Z HIGH-Z AI03920 3.5 Watchdog timer The watchdog timer can be used to detect an out-of-control microprocessor. The user programs the watchdog timer by setting the desired amount of time-out into the watchdog register, address 09h. Bits BMB4-BMB0 store a binary multiplier and the two lower order bits RB1-RB0 select the resolution, where 00 = 1/16 second, 01 = 1/4 second, 10 = 1 second, and 11 = 4 seconds. The amount of time-out is then determined to be the multiplication of the five-bit multiplier value with the resolution. (For example: writing 00001110 in the watchdog register = 3*1 or 3 seconds). Note: The accuracy of the timer is within the selected resolution. If the processor does not reset the timer within the specified period, the M41ST85W sets the WDF (watchdog flag) and generates a watchdog interrupt or a microprocessor reset. The most significant bit of the watchdog register is the watchdog steering bit (WDS). When set to a '0,' the watchdog will activate the IRQ/FT/OUT pin when timed-out. When WDS is set to a '1,' the watchdog will output a negative pulse on the RST pin for trec. The watchdog register, FT, AFE, ABE and SQWE bits will reset to a '0' at the end of a watchdog time-out when the WDS bit is set to a '1.' The watchdog timer can be reset by two methods: 1) a transition (high-to-low or low-to-high) can be applied to the watchdog input pin (WDI) or 2) the microprocessor can perform a WRITE of the watchdog register. The time-out period then starts over. Note: The WDI pin should be tied to VSS if not used. In order to perform a software reset of the watchdog timer, the original time-out period can be written into the watchdog register, effectively restarting the count-down cycle. Should the watchdog timer time-out, and the WDS bit is programmed to output an interrupt, a value of 00h needs to be written to the watchdog register in order to clear the IRQ/FT/OUT 24/43 Doc ID 7531 Rev 11 M41ST85W Clock operation pin. This will also disable the watchdog function until it is again programmed correctly. A READ of the flags register will reset the watchdog flag (bit D7; register 0Fh). The watchdog function is automatically disabled upon power-up and the watchdog register is cleared. If the watchdog function is set to output to the IRQ/FT/OUT pin and the frequency test function is activated, the watchdog function prevails and the frequency test function is denied. 3.6 Square wave output The M41ST85W offers the user a programmable square wave function which is output on the SQW pin. RS3-RS0 bits located in 13h establish the square wave output frequency. These frequencies are listed in Table 4. Once the selection of the SQW frequency has been completed, the SQW pin can be turned on and off under software control with the square wave enable bit (SQWE) located in register 0Ah. Table 4. Square wave output frequency Square wave bits 3.7 Square wave RS3 RS2 RS1 RS0 Frequency Units 0 0 0 0 None - 0 0 0 1 32.768 kHz 0 0 1 0 8.192 kHz 0 0 1 1 4.096 kHz 0 1 0 0 2.048 kHz 0 1 0 1 1.024 kHz 0 1 1 0 512 Hz 0 1 1 1 256 Hz 1 0 0 0 128 Hz 1 0 0 1 64 Hz 1 0 1 0 32 Hz 1 0 1 1 16 Hz 1 1 0 0 8 Hz 1 1 0 1 4 Hz 1 1 1 0 2 Hz 1 1 1 1 1 Hz Power-on reset The M41ST85W continuously monitors VCC. When VCC falls to the power fail detect trip point, the RST pulls low (open drain) and remains low on power-up for trec after VCC passes VPFD(max). The RST pin is an open drain output and an appropriate pull-up resistor should be chosen to control rise time. Doc ID 7531 Rev 11 25/43 Clock operation 3.8 M41ST85W Reset inputs (RSTIN1 & RSTIN2) The M41ST85W provides two independent inputs which can generate an output reset. The duration and function of these resets is identical to a reset generated by a power cycle. Table 5 and Figure 17 illustrate the AC reset characteristics of this function. Pulses shorter than tRLRH1 and tRLRH2 will not generate a reset condition. RSTIN1 and RSTIN2 are each internally pulled up to VCC through a 100 k resistor. Figure 17. RSTIN1 & RSTIN2 timing waveforms RSTIN1 tRLRH1 RSTIN2 tRLRH2 RST (1) tR1HRH tR2HRH AI03665 Note: With pull-up resistor Table 5. Reset AC characteristics Symbol tRLRH1(2) tRLRH2(3) tR1HRH(4) tR2HRH(4) Parameter(1) Min Max Unit RSTIN1 low to RSTIN1 high 200 ns RSTIN2 low to RSTIN2 high 100 RSTIN1 high to RST high 40 200 ms RSTIN2 high to RST high 40 200 ms ms 1. Valid for ambient operating temperature: TA = -40 to 85C; VCC = 2.7 to 3.6 V (except where noted). 2. Pulse width less than 50 ns will result in no RESET (for noise immunity). 3. Pulse width less than 20 ms will result in no RESET (for noise immunity). 4. Programmable (see Table 6 on page 28). 3.9 Power-fail input/output The power-fail input (PFI) is compared to an internal reference voltage (1.25 V). If PFI is less than the power-fail threshold (VPFI), the power-fail output (PFO) will go low. This function is intended for use as an undervoltage detector to signal a failing power supply. Typically PFI is connected through an external voltage divider (see Figure 5 on page 11) to either the unregulated DC input (if it is available) or the regulated output of the VCC regulator. The voltage divider can be set up such that the voltage at PFI falls below VPFI several milliseconds before the regulated VCC input to the M41ST85W or the microprocessor drops below the minimum operating voltage. During battery backup, the power-fail comparator turns off and PFO goes (or remains) low. This occurs after VCC drops below VPFD(min). When power returns, PFO is forced high, irrespective of VPFI for the write protect time (trec), which is the time from VPFD(max) until the inputs are recognized. At the end of this time, the power-fail comparator is enabled and PFO 26/43 Doc ID 7531 Rev 11 M41ST85W Clock operation follows PFI. If the comparator is unused, PFI should be connected to VSS and PFO left unconnected. 3.10 Century bit Bits D7 and D6 of clock register 03h contain the Century Enable bit (CEB) and the Century bit (CB). Setting CEB to a '1' will cause CB to toggle, either from a '0' to '1' or from '1' to '0' at the turn of the century (depending upon its initial state). If CEB is set to a '0,' CB will not toggle. 3.11 Output driver pin When the FT bit, AFE bit and watchdog register are not set, the IRQ/FT/OUT pin becomes an output driver that reflects the contents of D7 of the control register. In other words, when D7 (OUT bit) and D6 (FT bit) of address location 08h are a '0,' then the IRQ/FT/OUT pin will be driven low. Note: The IRQ/FT/OUT pin is an open drain which requires an external pull-up resistor. 3.12 Battery low warning The M41ST85W automatically performs battery voltage monitoring upon power-up and at factory-programmed time intervals of approximately 24 hours. The battery low (BL) bit, bit D4 of flags register 0Fh, will be asserted if the battery voltage is found to be less than approximately 2.5 V. The BL bit will remain asserted until completion of battery replacement and subsequent battery low monitoring tests, either during the next power-up sequence or the next scheduled 24-hour interval. If a battery low is generated during a power-up sequence, this indicates that the battery is below approximately 2.5 volts and may not be able to maintain data integrity in the SRAM. Data should be considered suspect and verified as correct. A fresh battery should be installed. If a battery low indication is generated during the 24-hour interval check, this indicates that the battery is near end of life. However, data is not compromised due to the fact that a nominal VCC is supplied. In order to insure data integrity during subsequent periods of battery backup mode, the battery should be replaced. The SNAPHAT(R) top may be replaced while VCC is applied to the device. Note: This will cause the clock to lose time during the interval the SNAPHAT battery/crystal top is disconnected. The M41ST85W only monitors the battery when a nominal VCC is applied to the device. Thus applications which require extensive durations in the battery backup mode should be powered-up periodically (at least once every few months) in order for this technique to be beneficial. Additionally, if a battery low is indicated, data integrity should be verified upon power-up via a checksum or other technique. Doc ID 7531 Rev 11 27/43 Clock operation 3.13 M41ST85W trec bit Bit D7 of clock register 04h contains the trec bit (TR). trec refers to the automatic continuation of the deselect time after VCC reaches VPFD. This allows for a voltage settling time before WRITEs may again be performed to the device after a power-down condition. The trec bit will allow the user to set the length of this deselect time as defined by Table 6. 3.14 Initial power-on defaults Upon initial application of power to the device, the following register bits are set to a '0' state: watchdog register, FT, AFE, ABE, SQWE, and TR. The following bits are set to a '1' state: ST, OUT, and HT (see Table 7). Table 6. trec definitions trec bit (TR) STOP bit (ST) 0 0 trec time Units Min Max 96 98 (1) ms 0 1 40 200 ms 1 X 50 2000 s 1. Default setting Table 7. Default values Condition Initial power-up(2) Subsequent power-up (with battery backup)(3) TR ST HT Out FT AFE ABE SQWE Watchdog register(1) 0 1 1 1 0 0 0 0 0 UC UC 1 UC 0 0 0 0 0 1. WDS, BMB0-BMB4, RB0, RB1. 2. State of other control bits undefined. 3. UC = Unchanged 28/43 Doc ID 7531 Rev 11 M41ST85W 4 Maximum ratings Maximum ratings Stressing the device above the rating listed in the absolute maximum ratings table may cause permanent damage to the device. These are stress ratings only and operation of the device at these or any other conditions above those indicated in the operating sections of this specification is not implied. Exposure to absolute maximum rating conditions for extended periods may affect device reliability. Refer also to the STMicroelectronics SURE Program and other relevant quality documents. Table 8. Absolute maximum ratings Symbol TSTG TSLD Parameter Storage temperature (VCC off, oscillator off) Lead solder temperature for 10 seconds Value Unit SNAPHAT(R) -40 to 85 C SOIC -55 to 150 C SOH28(1) 260 C SOX28(2) 240 C -0.3 to VCC+0.3 V VIO Input or output voltage VCC Supply voltage -0.3 to 4.6 V IO Output current 20 mA PD Power dissipation 1 W 1. For SOH28 package, lead-free (pb-free) lead finish: reflow at peak temperature of 260C (the time above 255C must not exceed 30 seconds). 2. The SOX28 package has lead-free (pb-free) lead finish, but cannot be exposed to peak reflow temperature in excess of 240C. Reflow at peak temperature of 240C (the time above 235C must not exceed 20 seconds). Caution: Negative undershoots below -0.3 V are not allowed on any pin while in the battery backup mode. Caution: Do NOT wave solder SOIC to avoid damaging SNAPHAT sockets. Doc ID 7531 Rev 11 29/43 DC and AC parameters 5 M41ST85W DC and AC parameters This section summarizes the operating and measurement conditions, as well as the DC and AC characteristics of the device. The parameters in the following DC and AC characteristic tables are derived from tests performed under the measurement conditions listed in the relevant tables. Designers should check that the operating conditions in their projects match the measurement conditions when using the quoted parameters. Table 9. DC and AC measurement conditions Parameter Note: M41ST85W VCC supply voltage 2.7 to 3.6 V Ambient operating temperature -40 to 85C Load capacitance (CL) 50 pF Input rise and fall times 50 ns Input pulse voltages 0.2 to 0.8VCC Input and output timing ref. voltages 0.3 to 0.7VCC Output High Z is defined as the point where data is no longer driven. Figure 18. AC testing input/output waveforms 0.8VCC 0.7VCC 0.3VCC 0.2VCC AI02568 Table 10. Capacitance Parameter(1)(2) Symbol CIN COUT(3) tLP Min Max Unit Input capacitance 7 pF Output capacitance 10 pF Low-pass filter input time constant (SDA and SCL) 50 ns 1. Effective capacitance measured with power supply at 5 V. Sampled only, not 100% tested. 2. At 25C, f = 1 MHz. 3. Outputs are deselected. 30/43 Doc ID 7531 Rev 11 M41ST85W Table 11. DC and AC parameters DC characteristics Sym Parameter M41ST85W Test condition(1) Unit Min IBAT(2) ICC1 ICC2 ILI(3) ILO(4) IOUT1(5) IOUT2 Battery current OSC ON Battery current OSC OFF Supply current Supply current (standby) Input leakage current TA = 25C, VCC = 0 V, VBAT = 3 V Typ Max 400 500 nA 50 nA f = 400 kHz 0.75 mA SCL, SDA = VCC - 0.3 V or VSS + 0.3 V 0.50 mA 0V VIN VCC 1 A 25 nA Input leakage current (PFI) -25 2 0V VIN VCC 1 A VOUT current (active) VOUT1 > VCC - 0.3 V 100 mA VOUT current (battery backup) VOUT2 > VBAT - 0.3 V 100 A Output leakage current VIH Input high voltage 0.7VCC VCC + 0.3 V VIL Input low voltage -0.3 0.3VCC V 2.5 3.5(6) V VBAT VOH VOHB(8) VOL VPFD VPFI VSO Battery voltage voltage(7) IOH = -1.0 mA Pull-up supply voltage (open drain) RST, IRQ/FT/OUT Output high VOH (battery backup) IOUT2 = -1.0 A 3.0 2.4 2.5 V 2.9 3.6 V 3.5 V Output low voltage IOL = 3.0 mA 0.4 V Output low voltage (open drain)(9) IOL = 10 mA 0.4 V V Power fail deselect PFI input threshold PFI hysteresis VCC = 3 V(W) PFI rising Battery backup switchover 2.55 2.60 2.70 1.225 1.250 1.275 V 20 70 mV 2.5 V 1. Valid for ambient operating temperature: TA = -40 to 85C; VCC = 2.7 to 3.6 V (except where noted). 2. Measured with VOUT and ECON open. 3. RSTIN1 and RSTIN2 internally pulled-up to VCC through 100 k resistor. WDI internally pulled-down to VSS through 100 k resistor. 4. Outputs deselected. 5. External SRAM must match RTC supervisor chip VCC specification. 6. For rechargeable backup, VBAT (max) may be considered VCC. 7. For PFO and SQW pins (CMOS). 8. Conditioned output (ECON) can only sustain CMOS leakage current in the battery backup mode. Higher leakage currents will reduce battery life. 9. For IRQ/FT/OUT, RST pins (open drain): if pulled-up to supply other than VCC, this supply must be equal to, or less than 3.0 V when VCC = 0 V (during battery backup mode). Doc ID 7531 Rev 11 31/43 DC and AC parameters M41ST85W Figure 19. Bus timing requirements sequence SDA tBUF tHD:STA tHD:STA tR tF SCL tHIGH P S tLOW tSU:DAT tHD:DAT tSU:STA SR tSU:STO P AI00589 Table 12. AC characteristics Parameter(1) Symbol fSCL SCL clock frequency tBUF Time the bus must be free before a new transmission can start tEXPD EX to ECON propagation delay tF tHD:DAT(2) Min Max Unit 0 400 kHz 1.3 SDA and SCL fall time 15 ns 300 ns 0 s START condition hold time (after this period the first clock pulse is generated) 600 ns tHIGH Clock high period 600 ns tLOW Clock low period 1.3 tHD:STA tR Data hold time s SDA and SCL rise time s 300 ns tSU:DAT Data setup time 100 ns tSU:STA START condition setup time (only relevant for a repeated start condition) 600 ns tSU:STO STOP condition setup time 600 ns 1. Valid for ambient operating temperature: TA = -40 to 85C; VCC = 2.7 to 3.6 V (except where otherwise noted). 2. Transmitter must internally provide a hold time to bridge the undefined region (300 ns max) of the falling edge of SCL. 32/43 Doc ID 7531 Rev 11 M41ST85W DC and AC parameters Figure 20. Power down/up mode AC waveforms VCC VPFD (max) VPFD (min) VSO tF tR tFB tRB tDR tPD trec PFO INPUTS DON'T CARE RECOGNIZED RECOGNIZED RST HIGH-Z OUTPUTS VALID VALID (PER CONTROL INPUT) (PER CONTROL INPUT) ECON AI03661 Table 13. Symbol Power down/up AC characteristics Parameter(1) Min Typ Max Unit tF(2) VPFD(max) to VPFD(min) VCC fall time 300 s tFB(3) VPFD(min) to VSS VCC fall time 10 s tPD EX at VIH before power down 0 s tPFD PFI to PFO propagation delay 15 25 s tR VPFD(min) to VPFD(max) VCC rise time 10 s tRB VSS to VPFD(min) VCC rise time 1 s Power-up deselect time 40 trec (4) 200 ms 1. Valid for ambient operating temperature: TA = -40 to 85C; VCC = 2.7 to 3.6 V (except where otherwise noted). 2. VPFD(max) to VPFD(min) fall time of less than tF may result in deselection/write protection not occurring until 200 s after VCC passes VPFD(min). 3. VPFD(min) to VSS fall time of less than tFB may cause corruption of RAM data. 4. Programmable (see Table 6 on page 28) Doc ID 7531 Rev 11 33/43 Package mechanical data 6 M41ST85W Package mechanical data In order to meet environmental requirements, ST offers these devices in different grades of ECOPACK(R) packages, depending on their level of environmental compliance. ECOPACK(R) specifications, grade definitions and product status are available at: www.st.com. ECOPACK(R) is an ST trademark. Figure 21. SOH28 - 28-lead plastic small outline, battery SNAPHAT(R), package outline A2 A C B eB e CP D N E H A1 L 1 SOH-A Note: Drawing is not to scale. Table 14. SOH28 - 28-lead plastic small outline, battery SNAPHAT(R), package mechanical data millimeters inches Symbol Typ Min A Typ Min 3.05 Max 0.120 A1 0.05 0.36 0.002 0.014 A2 2.34 2.69 0.092 0.106 B 0.36 0.51 0.014 0.020 C 0.15 0.32 0.006 0.012 D 17.71 18.49 0.697 0.728 E 8.23 8.89 0.324 0.350 - - - - eB 3.20 3.61 0.126 0.142 H 11.51 12.70 0.453 0.500 L 0.41 1.27 0.016 0.050 a 0 8 0 8 N 28 e CP 34/43 Max 1.27 0.050 28 0.10 Doc ID 7531 Rev 11 0.004 M41ST85W Package mechanical data Figure 22. 4-pin SNAPHAT(R) housing for 48 mAh battery & crystal, package outline A1 A2 A3 A eA B L eB D E SHTK-A Note: Drawing is not to scale. Table 15. 4-pin SNAPHAT(R) housing for 48 mAh battery & crystal, mechanical data millimeters inches Symbol Typ Min A Max Typ Min 9.78 Max 0.3850 A1 6.73 7.24 0.2650 0.2850 A2 6.48 6.99 0.2551 0.2752 A3 0.38 0.0150 B 0.46 0.56 0.0181 0.0220 D 21.21 21.84 0.8350 0.8598 E 14.22 14.99 0.5598 0.5902 eA 15.55 15.95 0.6122 0.6280 eB 3.20 3.61 0.1260 0.1421 L 2.03 2.29 0.0799 0.0902 Doc ID 7531 Rev 11 35/43 Package mechanical data M41ST85W Figure 23. 4-pin SNAPHAT(R) housing for 120 mAh battery & crystal, package outline A1 A2 A3 A eA B L eB D E SHTK-A Note: Drawing is not to scale. Table 16. 4-pin SNAPHAT(R) housing for 120 mAh battery & crystal, mechanical data millimeters inches Symbol Typ Min A Typ Min 10.54 Max 0.415 A1 8.00 8.51 0.315 0.335 A2 7.24 8.00 0.285 0.315 A3 36/43 Max 0.38 0.015 B 0.46 0.56 0.018 0.022 D 21.21 21.84 0.835 0.860 E 17.27 18.03 0.680 0.710 eA 15.55 15.95 0.612 0.628 eB 3.20 3.61 0.126 0.142 L 2.03 2.29 0.080 0.090 Doc ID 7531 Rev 11 M41ST85W Package mechanical data Figure 24. SOX28 - 28-lead plastic small outline, 300 mils, embedded crystal, package outline D 14 h x 45 1 C E 15 H 28 A2 A B ddd A1 e A1 L SO-E Note: Drawing is not to scale. Table 17. SOX28 - 28-lead plastic small outline, 300 mils, embedded crystal, mechanical data millimeters inches Symbol Typ Min Max A 2.44 A1 Min Max 2.69 0.096 0.106 0.15 0.31 0.006 0.012 A2 2.29 2.39 0.090 0.094 B 0.41 0.51 0.016 0.020 C 0.20 0.31 0.008 0.012 D 17.91 18.01 0.705 0.709 ddd Typ 0.10 E 7.57 7.67 - - H 10.16 L 0.004 0.298 0.302 - - 10.52 0.400 0.414 0.51 0.81 0.020 0.032 a 0 8 0 8 N 28 e 1.27 0.050 28 Doc ID 7531 Rev 11 37/43 Package mechanical data M41ST85W Figure 25. Carrier tape for SOH28 and SOX28 package P0 E P2 D T A0 F TOP COVER TAPE W B0 P1 CENTER LINES OF CAVITY K0 USER DIRECTION OF FEED AM03073v1 Table 18. Carrier tape dimensions for SOH28 and SOX28 packages Package W D SOH28 24.00 0.30 1.50 +0.10/ -0.00 SOX28 24.00 0.30 1.50 +0.10/ -0.00 38/43 A0 B0 K0 P1 T Unit Bulk Qty 1.75 4.00 2.00 11.50 0.10 0.10 0.10 0.10 12.90 0.10 18.70 0.10 3.20 0.10 16.00 0.10 0.30 0.05 mm 936 1.75 4.00 2.00 11.50 0.10 0.10 0.10 0.10 12.70 0.10 18.20 0.10 3.20 0.10 16.00 0.10 0.30 0.05 mm 1000 E P0 P2 F Doc ID 7531 Rev 11 M41ST85W Package mechanical data Figure 26. Reel schematic T 40mm min. Access hole At slot location B D C N A G measured Tape slot In core for Full radius At hub Tape start 2.5mm min.width AM04928v1 Table 19. Reel dimensions for 24 mm carrier tape (SOH28 and SOX28 packages) Carrier tape 24 mm (SOH28, SOX28) Note: A B (max) (min) 330 mm (13-inch) 1.5 mm C 13 mm 0.2 mm D N (min) (min) 20.2 mm 60 mm G 24.4 mm + 2/-0 mm T (max) 30.4 mm The dimensions given in Table 19 incorporate tolerances that cover all variations on critical parameters. Doc ID 7531 Rev 11 39/43 Part numbering 7 M41ST85W Part numbering Table 20. Ordering information scheme Example: M41ST 85W MH 6 E Device type M41ST Supply voltage and write protect voltage 85W = VCC = 2.7 to 3.6 V; 2.55V VPFD 2.70 V Package MH(1) = SOH28 MX(2) = SOX28 Temperature range 6 = -40 to 85C Shipping method For SOH28: E = ECOPACK(R) package, tubes(3) F = ECOPACK(R) package, tape & reel For SOX28: Blank = ECOPACK(R) package, tubes(3) TR = ECOPACK(R) package, tape & reel 1. The 28-pin SOIC package (SOH28) requires the SNAPHAT(R) battery/crystal package which is ordered separately under the part number "M4TXX-BR12SHx" in plastic tube (see Table 21). 2. The SOX28 package includes an embedded 32,768 Hz crystal. 3. Not recommended for new design. Contact local ST sales office for availability. Caution: Do not place the SNAPHAT(R) battery package "M4Txx-BR12SH" in conductive foam as it will drain the lithium button-cell battery. For other options, or for more information on any aspect of this device, please contact the ST sales office nearest you. Table 21. SNAPHAT(R) battery/crystal table Part number 40/43 Description Package M4T28-BR12SH Lithium battery (48 mAh) and crystal SNAPHAT(R) top SH M4T32-BR12SH Lithium battery (120 mAh) and crystal SNAPHAT(R) top SH Doc ID 7531 Rev 11 M41ST85W 8 Environmental information Environmental information Figure 27. Recycling symbols This product contains a non-rechargeable lithium (lithium carbon monofluoride chemistry) button cell battery fully encapsulated in the final product. Recycle or dispose of batteries in accordance with the battery manufacturer's instructions and local/national disposal and recycling regulations. Doc ID 7531 Rev 11 41/43 Revision history M41ST85W 9 Revision history Table 22. Document revision history Date Revision Aug-2000 1 Changes First issue 24-Aug-2000 1.1 Block diagram added (Figure 4) 12-Oct-2000 1.2 trec table removed, cross references corrected 18-Dec-2000 2 Reformatted, TOC added, and PFI input leakage current added (Table 11) 18-Jun-2001 2.1 Addition of trec information, table changed, one added (Table 2, 6); changed PFI/PFO graphic (see Figure 4); change to DC and AC characteristics, order information (Table 11, 12, 20); note added to "Setting Alarm Clock Registers" section; added temp./voltage info. to tables (Table 10, 11, 6, 12, 13); addition of default values (Table 7) 22-Jun-2001 2.2 Note added to clock operation section 26-Jul-2001 3 07-Aug-2001 3.1 Improve text in "Setting the Alarm Clock" section 20-Aug-2001 3.2 Change VPFD values in document 06-Sep-2001 3.3 DC characteristics VBAT changed; VOHB changed; PFI hysteresis (PFI Rising) spec. added; and crystal electrical characteristics table removed (Table 11, 6) 03-Dec-2001 3.4 Changed READ/WRITE mode sequences (Figure 10, 12); change in VPFD lower limit for 5V (M41ST85Y) part only (Table 11, 20) 01-May-2002 3.5 Change trec definition (Table 6); modify reflow time and temperature footnote (Table 8) 03-Jul-2002 3.6 Modify DC characteristics table footnote, default values (Table 11, 7) 15-Nov-2002 3.7 Added embedded crystal (MX) package option; corrected initial power-up condition (cover page, Figure 1, 3, 4, 5, 24, Table 1, 7, 20, ) 24-Jan-2003 3.8 Update diagrams (Figure 4, 5, 24); update values (Table 13, 5, 6, 7, ) 25-Feb20-03 4 New Si changes (Table 13, 5, 6); corrected dimensions (Figure 24; Table ) 20-May-2004 5 Reformatted; correct dimensions; update Lead-free information (Figure 20, 13, 16; Table 8, 16, 20) Change in product maturity 15-Jun-2004 6 Update characteristics; add package shipping (Figure 3; Table 1, 11, 20) 13-Sep-2004 7 Update maximum ratings (Table 8) 10-Jan-2006 8 Updated template, Lead-free text, removed 5V references (Figure 1, 2, 3, 4, 5; Table 5, 8, 9, 11, 12, 13, 20, 21) 03-Oct-2007 9 Reformatted document, minor textual changes; added lead-free second level interconnect information to cover page and Section 6: Package mechanical data; updated Table 8. 16-Dec-2008 10 Added Section 8: Environmental information; updated Table 8, Section 6: Package mechanical data; minor reformatting. 03-Oct-2011 11 Updated Table 20: Ordering information scheme as shipping in tubes is not recommended for new design; updated Section 8: Environmental information; added Figure 25, 26 and Table 18, 19. 42/43 Doc ID 7531 Rev 11 M41ST85W Please Read Carefully: Information in this document is provided solely in connection with ST products. STMicroelectronics NV and its subsidiaries ("ST") reserve the right to make changes, corrections, modifications or improvements, to this document, and the products and services described herein at any time, without notice. All ST products are sold pursuant to ST's terms and conditions of sale. Purchasers are solely responsible for the choice, selection and use of the ST products and services described herein, and ST assumes no liability whatsoever relating to the choice, selection or use of the ST products and services described herein. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted under this document. If any part of this document refers to any third party products or services it shall not be deemed a license grant by ST for the use of such third party products or services, or any intellectual property contained therein or considered as a warranty covering the use in any manner whatsoever of such third party products or services or any intellectual property contained therein. UNLESS OTHERWISE SET FORTH IN ST'S TERMS AND CONDITIONS OF SALE ST DISCLAIMS ANY EXPRESS OR IMPLIED WARRANTY WITH RESPECT TO THE USE AND/OR SALE OF ST PRODUCTS INCLUDING WITHOUT LIMITATION IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE (AND THEIR EQUIVALENTS UNDER THE LAWS OF ANY JURISDICTION), OR INFRINGEMENT OF ANY PATENT, COPYRIGHT OR OTHER INTELLECTUAL PROPERTY RIGHT. UNLESS EXPRESSLY APPROVED IN WRITING BY TWO AUTHORIZED ST REPRESENTATIVES, ST PRODUCTS ARE NOT RECOMMENDED, AUTHORIZED OR WARRANTED FOR USE IN MILITARY, AIR CRAFT, SPACE, LIFE SAVING, OR LIFE SUSTAINING APPLICATIONS, NOR IN PRODUCTS OR SYSTEMS WHERE FAILURE OR MALFUNCTION MAY RESULT IN PERSONAL INJURY, DEATH, OR SEVERE PROPERTY OR ENVIRONMENTAL DAMAGE. ST PRODUCTS WHICH ARE NOT SPECIFIED AS "AUTOMOTIVE GRADE" MAY ONLY BE USED IN AUTOMOTIVE APPLICATIONS AT USER'S OWN RISK. Resale of ST products with provisions different from the statements and/or technical features set forth in this document shall immediately void any warranty granted by ST for the ST product or service described herein and shall not create or extend in any manner whatsoever, any liability of ST. ST and the ST logo are trademarks or registered trademarks of ST in various countries. Information in this document supersedes and replaces all information previously supplied. The ST logo is a registered trademark of STMicroelectronics. All other names are the property of their respective owners. (c) 2011 STMicroelectronics - All rights reserved STMicroelectronics group of companies Australia - Belgium - Brazil - Canada - China - Czech Republic - Finland - France - Germany - Hong Kong - India - Israel - Italy - Japan Malaysia - Malta - Morocco - Philippines - Singapore - Spain - Sweden - Switzerland - United Kingdom - United States of America www.st.com Doc ID 7531 43/43