BURNDY Compression ONE HOLE HYLUGTM CODE CONDUCTOR STANDARD BARREL DIE AND COLOR CODE INFORMATION BEVELED ENTRY INSPECTION WINDOW TYPES YA-L, YA-L-TC CRIMP COPPER COMPRESSION TERMINAL CABLE ACCOMMODATION UL LISTED 90 C, 600 VOLT TO 35 KV B C-6 ELECTRO-TIN PLATED B 90 B T T T 45 L Fig. 1 Catalog Number YAV10-45-BOX YAV10-BOX YAV10R-BOX YAV10R3-BOX YAV10T2-BOX YAV10T3-45-BOX YAV10T3-BOX YAV10T4-BOX YA8CL1-BOX YA8CL1-45 YA8CL1-90 YA8CL2-BOX YA8CL2-45 YA8CL2-90 YA8CL3-BOX YA8CL3-45 YA8CL3-90 YA8CL4-BOX YA8CL4-45 YA8CL4-90 YA8CL-BOX YA8CL-45 YA8CL-90 YA6CL-BOX YA6CL-45 YA6CL-90 YA6CL1-BOX YA6CL1-45 YA6CL1-90 YA6CL3-BOX YA6CL3-45 YA6CL3-90 *** Fig # AWG 1 1 #14-#10 1 STR 1 1 #12-#10 2 SOL 1 1 1 2 3 1 2 #8 AWG 3 1 #8 WELD 2 3 37/24 1 2 #6 SOLID 3 1 2 3 1 2 3 1 2 #6 AWG 3 1 2 3 MM2 6 10 Tongue Width 8-10 .38 1/4 5/16 1/4 1/4 3/8 .47 .53 .47 .47 .56 Figure Dimensions (B) (T) .405 .058 .405 .058 .375 .058 .405 .047 .38 .047 .405 .047 .405 .047 .38 .047 1/4 .44 .44 .08 5/16 .52 .44 .06 3/8 .58 .44 .06 1/2 .71 .44 .05 8-10 .41 .44 .08 1/4 .45 .81 .08 8-10 .41 .41 .42 .81 .81 .81 .09 .09 .09 5/16 .52 .81 .07 * Use P-UADP-1 adapter with "U" dies in Y46 HYPRESSTM. ** P-RT die sets for use in Y46 HYPRESSTM only, P-UADP-1 adapter not required. *** The MM2 conductor sizes listed are the recommendations for Class 2 conductor. Fig. 3 Fig. 2 Conductor Stud Hole Size L L (# of crimps) Mechanical MD6, OUR840 MD7-34R Y8MRB-1(1) - Dieless (L) .92 1.02 .77 .83 1.12 1.10 1.10 1.18 1.26 1.24 .80 1.38 1.34 .92 1.51 1.45 1.04 1.76 1.67 1.28 1.16 1.16 .71 1.73 1.43 .81 1.54 1.29 .72 1.79 1.54 .93 Installation Tooling Hydraulic Wire BCT500HS Y35,Y39,Y750 Color Die Strip Y500CTHS Y46, BAT35, BAT750 Code Index Length - - Y1MR (1) Y8MRB-1 (1) W8CVT (1) W8CVT (1) Y2MR (1) W8CRT (1) W8CRT (1) MY29-3 (1) X8CRT (1) X8CRT (1) MY29-11 (1) MRC840 (1) U8CRT (1) Red 49 7/16 Y1MR (1) MY29-3 (1) W5CVT (1) W5CVT (1) MY29-11 (1) W5CRT (1) W5CRT (1) MRC840 (1) X5CRT (1) X5CRT (1) Y2MR (1) X8CART (1) X8CART (1) Y644M (1) U5CRT (1) Blue 7 7/8 The MM2 conductor size listed is for both Class 2 and Class 5 conductor. See tooling section of this catalog for complete tool and die listings. - 7/16 For applications greater than 2000 Volts, consult cable manufacturer for voltage stress relief instructions. BURNDY Compression B ONE HOLE HYLUGTM CODE CONDUCTOR STANDARD BARREL (CONTINUED) B 90 B T T T 45 L L L Fig. 3 Fig. 2 Fig. 1 Conductor Catalog Number YA6CL4-BOX YA6CL4-45 YA6CL4-90 YA6CL6-BOX YA6CL6-45 YA6CL6-90 YA5CL-BOX YA5CL-45 YA5CL-90 YA4CL-BOX YA4CL-45 YA4CL-90 YA4CL1-BOX YA4CL1-45 YA4CL1-90 YA4CL3-BOX YA4CL3-45 YA4CL3-90 YA4CL4-BOX YA4CL4-45 YA4CL4-90 YA4CL6-BOX YA4CL6-45 YA4CL6-90 YA3CL YA3CL-45 YA3CL-90 YA2CL2-BOX YA2CL2-45 YA2CL2-90 YA2CL-BOX YA2CL-45 YA2CL-90 YA2CL4-BOX YA2CL4-45 YA2CL4-90 YA2CL6-BOX YA2CL6-45 YA2CL6-90 YA1CL2 YA1CL2-45 YA1CL2-90 YA1CL-BOX YA1CL-45 YA1CL-90 YA1CL4-BOX YA1CL4-45 YA1CL4-90 YA1CL6-BOX YA1CL6-45 YA1CL6-90 Fig # 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 AWG *** MM2 Stud Hole Size Tongue Width 3/8 .63 #6 AWG #5 AWG #4 AWG # 3 STR # 2 SOL #2 AWG #1 AWG 25 1/2 .75 1/4 .44 1/4 .50 8-10 .50 5/16 .58 3/8 .58 1/2 .71 5/16 .55 1/4 .61 5/16 .61 35 3/8 .61 1/2 .73 1/4 .68 5/16 .68 50 3/8 .68 1/2 .73 * Use P-UADP-1 adapter with "U" dies in Y46 HYPRESSTM. ** P-RT die sets for use in Y46 HYPRESSTM only, P-UADP-1 adapter not required. Figure Dimensions (B) (T) (L) 1.83 .81 .06 1.57 1.05 2.15 .81 .12 1.92 1.30 1.65 .81 .07 1.51 .81 1.74 .81 .09 1.44 .84 1.58 .81 .09 1.28 .75 1.92 .81 .08 1.68 .96 1.92 .81 .08 1.68 1.08 2.20 .81 .06 2.02 1.32 1.88 .88 .09 1.76 .98 1.88 .88 .11 1.55 .89 1.93 .88 .11 1.62 1.01 2.06 .88 .11 1.74 1.14 2.32 .88 .09 2.17 1.37 1.81 .88 .10 1.70 .91 1.94 .88 .01 1.82 1.03 2.06 .88 .10 1.95 1.16 2.37 .88 .09 2.22 1.40 Dieless (# of crimps) Mechanical MD6, OUR840 MD7-34R Installation Tooling Hydraulic Wire BCT500HS Y35,Y39,Y750 Color Die Strip Y500CTHS Y46, BAT35, BAT750 Code Index Length C-7 W5CVT (1) W5CVT (1) Y1MR (1) W5CRT (1) W5CRT (1) MY29-3 (1) X5CRT (1) X5CRT (1) MY29-11 (1) X8CART (1) X8CART (1) MRC840 (1) Y2MR (1) W5CRT (1) W5CRT (1) Y644M (1) W5CVT (1) X5CRT (1) X5CRT (1) W5CVT (1) W4CVT (1) W4CVT (1) W4CRT (1) W4CRT (1) X4CRT (1) X4CRT (1) Y1MR (1) MY29-3 (1) MY29-11 (1) MRC840 (1) Y2MR (2) W3CRT (1) W3CRT (1) Y644M (1) W2CVT (1) W2CVT (1) W2CRT (1) W2CRT (1) X2CRT (1) X2CRT (1) Y1MR (1) MY29-3 (1) W1CVT (1) W1CVT (1) MY29-11 (1) W1CRT-1 (1) W1CRT-1 (1) MRC840 (1) X1CRT-1 (1) X1CRT-1 (1) Y644M (1) *** The MM2 conductor sizes listed are the recommendations for Class 2 conductor. See tooling section of this catalog for complete tool and die listings. U5CRT (1) UBCABT (1) Blue 7 7/8 U5CRT (1) Blue 7 7/8 U4CRT (1) U6CABT (1) Gray 8 7/8 U3CRT (1) White 9 15/16 U2CRT (1) Brown 10 15/16 U1CRT-1 (1) U4CABT (1) Green 11 15/16 For applications greater than 2000 Volts, consult cable manufacturer for voltage stress relief instructions. BURNDY Compression B ONE HOLE HYLUGTM CODE CONDUCTOR STANDARD BARREL (CONTINUED) T T T 45 L L L Fig. 1 Fig # 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 AWG *** MM2 Stud Hole Size Tongue Width 1/4 .75 3/8 .75 1/0 AWG 2/0 AWG 1/2 .75 5/16 .88 1/4 .83 5/16 .83 3/8 .83 70 3/4 .96 1/2 .83 5/8 .88 5/16 .62 1/4 1 5/16 .91 3/0 AWG 3/8 .91 1/2 .91 3/8 .76 5/8 1.02 4/0 AWG 1/4 * Use P-UADP-1 adapter with "U" dies in Y46 HYPRESSTM. ** P-RT die sets for use in Y46 HYPRESSTM only, P-UADP-1 adapter not required. 1.02 Figure Dimensions (B) (T) (L) 1.84 .88 .12 1.76 .94 2.09 .88 .12 2.01 1.19 2.34 .88 .12 2.26 1.44 1.96 .88 .12 1.88 1.07 1.94 .94 .12 1.78 .96 2.06 .94 .12 1.91 1.09 2.19 .94 .12 2.03 1.21 2.96 .94 .12 2.77 1.89 2.44 .94 .12 2.28 1.46 2.69 .94 .11 2.50 1.71 .94 .13 2.62 2.04 1.00 .13 1.91 .99 2.16 1.00 .13 2.03 1.12 2.29 1.00 .13 1.91 .99 2.54 1.00 .13 2.41 1.49 1.00 .12 2.71 .88 .14 2.64 1.79 1.96 .88 .14 1.89 Fig. 3 Fig. 2 Conductor Catalog Number C-8 YA25L2-BOX YA25L2-45 YA25L2-90 YA25L4-BOX YA25L4-45 YA25L4-90 YA25L6-BOX YA25L6-45 YA25L6-90 YA25L-BOX YA25L-45 YA25L-90 YA26L2-BOX YA26L2-45 YA26L2-90 YA26L3-BOX YA26L3-45 YA26L3-90 YA26L-BOX YA26L-45 YA26L-90 YA26L60 YA26L60-45 YA26L60-90 YA26L6-BOX YA26L6-45 YA26L6-90 YA26L7-BOX YA26L7-45 YA26L7-90 YA26LNT516 YA27L2-BOX YA27L2-45 YA27L2-90 YA27L3 YA27L3-45 YA27L3-90 YA27L4-BOX YA27L4-45 YA27L4-90 YA27L-BOX YA27L-45 YA27L-90 YA27LNT38 YA28L17-BOX YA28L17-45 YA28L17-90 YA28L2-BOX YA28L2-45 B 90 B Dieless (# of crimps) MY29-3 (1) MY29-11 (1) MRC840 (2) Y644M (1) Mechanical MD6, OUR840 MD7-34R Installation Tooling Hydraulic Wire BCT500HS Y35,Y39,Y750 Color Die Strip Y500CTHS Y46, BAT35, BAT750 Code Index Length W25VT (2) W25VT (2) W25RT (2) W25RT (2) X25RT (2) X25RT (2) U25RT (1) U2CABT (1) Pink 12 15/16 W26VT (2) W26VT (2) W26RT (2) W26RT (2) X26RT (2) X26RT (2) U26RT (1) Black 13 1 W27VT (2) W27VT (2) W27RT (2) W27RT (2) X27RT (3) X27RT (3) U27RT (1) Orange 14 1-1/16 W28VT (2) W28VT (2) W28RT (2) W28RT (2) X28RT (3) X28RT (3) U28RT (1) Purple 15 *** The MM2 conductor sizes listed are the recommendations for Class 2 conductor. See tooling section of this catalog for complete tool and die listings. 1-1/8 For applications greater than 2000 Volts, consult cable manufacturer for voltage stress relief instructions. BURNDY Compression B ONE HOLE HYLUGTM CODE CONDUCTOR STANDARD BARREL (CONTINUED) T T T 45 L Fig # AWG 3 1 2 3 1 2 3 4/0 AWG 1 2 3 1 2 3 1 1 2 3 1 2 3 1 2 250 kcmil 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 1 2 3 1 2 3 300 kcmil 350 kcmil *** MM2 Stud Hole Size 1/4 Tongue Width 1.02 5/16 1.02 3/8 1.02 3/4 1.05 1/2 1.02 3/8 76 1/4 1.11 3/8 1.11 5/16 1.11 7/8 1.11 3/8 96 1/2 1.11 1/2 1.20 5/16 1.20 3/8 1.20 7/8 1.20 3/4 1.20 5/8 1.20 1/2 1.29 150 185 * Use P-UADP-1 adapter with "U" dies in Y46 HYPRESSTM. ** P-RT die sets for use in Y46 HYPRESSTM only, P-UADP-1 adapter not required. Figure Dimensions (B) (T) (L) .88 .14 1.04 2.08 .88 .14 2.01 1.16 2.21 .88 .14 2.14 1.29 2.90 .88 .13 2.81 1.97 2.46 .88 .14 2.39 1.54 .88 .16 2.79 2.17 1.06 .16 2.07 1.08 2.42 1.06 .16 2.32 1.33 2.30 1.06 .16 2.20 1.20 3.36 1.06 .14 3.23 2.26 1.06 .16 2.96 2.67 1.06 .16 2.57 1.58 2.69 1.03 .16 2.60 1.61 2.31 1.03 .16 2.22 1.24 2.44 1.03 .16 2.35 1.36 3.37 1.03 .16 3.29 2.30 3.12 1.03 .16 2.94 2.85 1.03 .16 1.86 2.75 1.06 .18 2.75 1.65 L L Fig. 3 Fig. 2 Fig. 1 Conductor Catalog Number YA28L2-90 YA28L3-BOX YA28L3-45 YA28L3-90 YA28L4-BOX YA28L4-45 YA28L4-90 YA28L56-BOX YA28L56-45 YA28L56-90 YA28L-BOX YA28L-45 YA28L-90 YA28LNT38 YA29L2-BOX YA29L2-45 YA29L2-90 YA29L4-BOX YA29L4-45 YA29L4-90 YA29L7-BOX YA29L7-45 YA29L7-90 YA29LTC78-BOX YA29LTC78-45 YA29LTC78-90 YA29LNT38 YA29L-BOX YA29L-45 YA29L-90 YA30L-BOX YA30L-45 YA30L-90 YA30L1-BOX YA30L1-45 YA30L1-90 YA30L24-BOX YA30L24-45 YA30L24-90 YA30L27-BOX YA30L27-45 YA30L27-90 YA30L28-BOX YA30L7-BOX YA30L7-45 YA30L7-90 YA31L-BOX YA31L-45 YA31L-90 B 90 B Dieless (# of crimps) Mechanical MD6, OUR840 MD7-34R Installation Tooling Hydraulic Wire BCT500HS Y35,Y39,Y750 Color Die Strip Y500CTHS Y46, BAT35, BAT750 Code Index Length MY29-3 (1) W28VT (2) W28VT (2) MY29-11 (1) W28RT (2) W28RT (2) MRC840 (2) X28RT (2) X28RT (3) Y644M (1) U28RT (1) Purple 15 1-1/8 MY29-3 (1) W29VT (2) MY29-11 (1) X29RT (4) Y644M (1) W29VT (2) W29RT (2) X29RT (4) U29RT (1) Yellow 16 1-1/8 W30VT (2) W30VT (2) W30RT (2) U30RT (2) U28ART (2) White 17 1-1/16 W31VT (2) W31VT (2) W31RT (2) U31RT (2) U29ART (2) Red 18 1-3/16 Y644M (1) *** The MM2 conductor sizes listed are the recommendations for Class 2 conductor. See tooling section of this catalog for complete tool and die listings. For applications greater than 2000 Volts, consult cable manufacturer for voltage stress relief instructions. C-9 BURNDY Compression B ONE HOLE HYLUGTM CODE CONDUCTOR STANDARD BARREL (CONTINUED) T T T 45 L L L Fig. 1 Fig. 2 Conductor C-10 Catalog Number YA31L11 YA31L11-45 YA31L11-90 YA31L36-BOX YA31L36-45 YA31L36-90 YA31L7-BOX YA31L7-45 YA31L7-90 YA31LNT38 YA32L-BOX YA32L-45 YA32L-90 YA32L1-BOX YA32L1-45 YA32L1-90 YA32L14-BOX YA32L14-45 YA32L14-90 YA32LTC78-BOX YA32LTC78-45 YA32LTC78-90 YA33L-BOX YA33L-45 YA33L-90 YA34L-BOX YA34L-45 YA34L-90 YA34L20-BOX YA34L20-45 YA34L20-90 YA34L37-BOX YA34L37-45 YA34L37-90 YA34L6-BOX YA34L6-45 YA34L6-90 YA34L8-BOX YA34L8-45 YA34L8-90 YA34L9-BOX YA34L9-45 YA34L9-90 YA35L-BOX YA35L-45 YA35L-90 YA36L11-BOX YA36L-BOX YA36L-45 YA36L-90 Fig # AWG 1 2 3 1 2 350 kcmil 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 1 2 3 *** MM2 185 Stud Hole Size Tongue Width 3/8 1.29 7/8 1.29 5/8 1.29 3/8 96 5/8 1.38 1/2 1.40 400 kcmil 450 kcmil 500 kcmil 600 kcmil 3/8 1.38 7/8 1.40 5/8 1.48 5/8 1.55 1 1.55 3/8 1.55 240 550 kcmil 300 B 90 B 1/2 1.55 3/4 1.55 7/8 1.55 5/8 1.65 1/2 1.74 5/8 1.74 * Use P-UADP-1 adapter with "U" dies in Y46 HYPRESSTM. ** P-RT die sets for use in Y46 HYPRESSTM only, P-UADP-1 adapter not required. Figure Dimensions (B) (T) (L) 2.50 1.06 .18 2.42 1.40 4.02 1.06 .18 4.02 3.94 3.00 1.06 .18 3.00 1.90 1.06 .18 3.37 3.18 1.19 .19 3.08 1.95 2.93 1.19 .19 2.83 1.70 2.68 1.19 .19 2.58 1.45 3.62 1.19 .19 3.52 2.38 3.57 1.50 .21 3.30 2.00 3.37 1.27 .23 3.30 2.03 4.05 1.27 .23 3.99 2.72 2.87 1.27 .23 2.80 1.53 3.12 1.27 .23 3.05 1.78 3.55 1.27 .23 3.49 2.22 3.80 1.27 .23 3.74 2.47 3.81 1.69 .25 3.67 2.08 1.38 .27 3.29 3.72 1.38 .27 3.51 2.11 Dieless (# of crimps) Mechanical MD6, OUR840 MD7-34R Fig. 3 Installation Tooling Hydraulic Wire BCT500HS Y35,Y39,Y750 Color Die Strip Y500CTHS Y46, BAT35, BAT750 Code Index Length W31VT (2) W31VT (2) W31RT (2) U31RT (2) U29ART (2) Red 18 1-3/16 W32VT (2) W32VT (2) W32RT (2) U32RT (2) U30ART (2) Blue 19 W33VT (2) W33VT (2) W33RT (2) U33RT (2) Gray 326 1-9/16 W34VT (2) W34VT (2) W34RT (2) U34RT (2) U31ART (2) Brown 20 1-7/16 - - U35RT (2) Yellow 21 1-3/4 - - U36RT (2) Green 22 1-3/4 1-1/4 Y644M (1) *** The MM2 conductor sizes listed are the recommendations for Class 2 conductor. See tooling section of this catalog for complete tool and die listings. For applications greater than 2000 Volts, consult cable manufacturer for voltage stress relief instructions. BURNDY Compression B ONE HOLE HYLUGTM CODE CONDUCTOR STANDARD BARREL (CONTINUED) T T T 45 L Conductor Fig # 1 2 3 1 2 3 1 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 1 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 AWG *** MM2 Stud Hole Size 600 kcmil 300 7/8 1.74 650 kcmil 5/8 1.80 700 kcmil 5/8 1.84 5/8 1.91 7/8 1.91 Tongue Width 750 kcmil 1-1/4 1.91 3/8 1.12 1/2 1.91 5/8 1.98 5/8 2.01 5/8 2.19 1/2 1 2.49 2.19 1250 kcmil 3/4 2.46 1300 kcmil 3/4 2.53 1500 kcmil 3/4 2.69 1750 kcmil 3/4 2.90 2000 kcmil 3/4 3.10 800 kcmil 400 850 kcmil 1000 kcmil 500 * Use P-UADP-1 adapter with "U" dies in Y46 HYPRESSTM. ** P-RT die sets for use in Y46 HYPRESSTM only, P-UADP-1 adapter not required. Figure Dimensions (B) (T) (L) 3.97 1.38 .27 3.95 2.55 3.57 3.55 1.39 .27 2.14 3.76 3.66 1.45 .27 3.60 2.15 3.67 1.42 .27 3.61 2.17 4.10 1.42 .27 4.05 2.61 4.85 1.42 .27 4.80 3.36 1.42 .27 4.70 3.41 1.42 .27 3.36 1.92 3.81 1.42 .30 3.69 2.21 4.15 1.88 .31 4.03 2.23 4.04 1.65 .33 4.01 2.32 1.65 .33 3.98 1.65 .33 4.73 4.68 2.00 .38 4.64 2.62 4.71 2.00 .39 4.68 2.65 4.78 2.00 .40 4.75 2.71 5.05 2.19 .42 5.00 2.79 5.19 2.25 .46 5.19 2.89 L L Fig. 3 Fig. 2 Fig. 1 Catalog Number YA36LTC78-BOX YA36LTC78-45 YA36LTC78-90 YA37L-BOX YA37L-45 YA37L-90 YA37L1-BOX YA38L-BOX YA38L-90 YA38L-45 YA39L-BOX YA39L-45 YA39L-90 YA39L2-BOX YA39L2-45 YA39L2-90 YA39L9-BOX YA39L9-45 YA39L9-90 YA39LNT38 YA39L6-BOX YA39L6-45 YA39L6-90 YA40L-BOX YA40L-45 YA40L-90 YA41L-BOX YA41L-45 YA41L-90 YA44L-BOX YA44L-45 YA44L-90 YA44L2-BOX YA44L23-BOX YA-45L-BOX YA-45L-45 YA-45L-90 YA-453L-BOX YA-453L-45 YA-453L-90 YA46L-BOX YA46L-45 YA46L-90 YA47L-BOX YA47L-45 YA47L-90 YA48L-BOX YA48L-45 YA48L-90 B 90 B Dieless (# of crimps) Y644M (1) Mechanical MD6, OUR840 MD7-34R Installation Tooling Hydraulic Wire BCT500HS Y35,Y39,Y750 Color Die Strip Y500CTHS Y46, BAT35, BAT750 Code Index Length - - U36RT (2) U32ART (2) Green 22 1-3/4 - - U37RT (2) Orange 23 1-15/16 - - U38RT (2) Pink 400 1-15/16 - - U39RT (2) P39RT (2) ** Black 24 1-15/16 - - P40RT(3) ** Orange 25 1-15/16 - - - Gold 26 1-15/16 - - P44RT(3) ** White 27 1-15/16 - - P45RT(3) ** Yellow 29 2-1/16 - - - Orange 30 2-1/16 - - P46RT (3) ** - Green 31 2-1/16 Gray 33 2-1/4 Brown 34 2-1/4 *** The MM2 conductor sizes listed are the recommendations for Class 2 conductor. See tooling section of this catalog for complete tool and die listings. For applications greater than 2000 Volts, consult cable manufacturer for voltage stress relief instructions. C-11