BURNDY
Compression
C-6
ONE HOLE HYLUG™
CODE CONDUCTOR
STANDARD BARREL
TYPES Y A-L,Y A-L-TC
COPPER COMPRESSION
TERMINAL
UL LISTED 90° C,
600 V OLT TO 35 KV
B
B
B
TTT
L
45°
90°
L
L
* Use P-UADP-1 adapter with "U" dies in Y46 HYPRESS™.
** P-RT die sets for use in Y46 HYPRESS™ only, P-UADP-1
adapter not required.
*** The MM2conductor sizes listed are the recommendations
for Class 2 conductor.
ELECTRO-TIN
PLATED CABLE
ACCOMMODATION
CRIMP
DIE AND COLOR
CODE INFORMATION
INSPECTION
WINDOW
BEVELED
ENTRY
Fig. 1 Fig. 2 Fig. 3
Conductor Installation T ooling
Stud Figure Mechanical Hydraulic Wire
*** Hole Tongue Dimensions Dieless MD6, OUR840 BCT500HS Y35,Y39,Y750 Color Die Strip
Catalog Number Fig # AWG MM2Size Width (B) (T) (L) (# of crimps) MD7-34R Y500CTHS
Y46, BAT35, BAT750
Code Index Length
YAV10-45-BOX 1 .405.058.92
YAV10-BOX 1#14-#10 8-10 .38.405.0581.02
YAV10R-BOX 1STR .375.058.77
YAV10R3-BOX 1 6 1/4.47.405.047.83Y8MRB-1(1) - - - - 7/16
YAV10T2-BOX 1 5/16.53.38.0471.12
YAV10T3-45-BOX 2#12-#10 1/4.47.405.0471.10
YAV10T3-BOX 1SOL 1/4.47.405.0471.10
YAV10T4-BOX 1 3/8.56.38.0471.18
YA8CL1-BOX 1 1.26
YA8CL1-45 2 1/4.44.44.081.24
YA8CL1-90 3 .80
YA8CL2-BOX 1 1.38
YA8CL2-45 2 #8 AWG 5/16.52.44.061.34Y1MR (1)
YA8CL2-90 3 .92Y8MRB-1 (1)
YA8CL3-BOX 1 #8 WELD 1.51Y2MR (1) W8CVT (1) W8CVT (1)
YA8CL3-45 2 3/8.58.44.061.45MY29-3 (1) W8CRT (1) W8CRT (1) U8CRT (1) Red 49 7/16
YA8CL3-90 3 37/24 10 1.04MY29-11 (1) X8CRT (1) X8CRT (1)
YA8CL4-BOX 1 1.76MRC840 (1)
YA8CL4-45 2 #6 SOLID 1/2.71.44.051.67
YA8CL4-90 3 1.28
YA8CL-BOX 1 1.16
YA8CL-45 2 8-10 .41.44.081.16
YA8CL-90 3 .71
YA6CL-BOX 1 1.73
YA6CL-45 2 1/4.45.81.081.43
YA6CL-90 3 .81Y1MR (1) W5CVT (1) W5CVT (1)
YA6CL1-BOX 1 .41.81.091.54MY29-3 (1) W5CRT (1) W5CRT (1)
YA6CL1-45 2 #6 AWG 8-10 .41.81.091.29MY29-11 (1) U5CRT (1) Blue 7 7/8
YA6CL1-90 3 .42.81.09.72MRC840 (1) X5CRT (1) X5CRT (1)
YA6CL3-BOX 1 1.79Y2MR (1) X8CART (1) X8CART (1)
YA6CL3-45 2 5/16.52.81.071.54Y644M (1)
YA6CL3-90 3 .93
The MM2conductor size listed is for both Class 2 and
Class 5 conductor.
See tooling section of this catalog for complete tool and
die listings.
For applications greater than 2000 Volts, consult cable
manufacturer for voltage stress relief instructions.
BURNDY
Compression
C-7
ONE HOLE HYLUG™
CODE CONDUCTOR
STANDARD BARREL
(CONTINUED)
* Use P-UADP-1 adapter with "U" dies in Y46 HYPRESS™.
** P-RT die sets for use in Y46 HYPRESS™ only, P-UADP-1
adapter not required.
B
B
B
TTT
L
45°
90°
L
L
Fig. 2 Fig. 3
Fig. 1
*** The MM2conductor sizes listed are the recommendations
for Class 2 conductor.
See tooling section of this catalog for complete tool and die
listings.
For applications greater than 2000 Volts, consult cable
manufacturer for voltage stress relief instructions.
Conductor Installation T ooling
Stud Figure Mechanical Hydraulic Wire
*** Hole Tongue Dimensions Dieless MD6, OUR840 BCT500HS Y35,Y39,Y750 Color Die Strip
Catalog Number Fig # AWG MM2Size Width (B) (T) (L) (# of crimps) MD7-34R Y500CTHS
Y46, BAT35, BAT750
Code Index Length
YA6CL4-BOX 1 1.83
YA6CL4-45 2 3/8.63.81.061.57Y1MR (1) W5CVT (1) W5CVT (1)
YA6CL4-90 3#6 AWG 1.05MY29-3 (1) W5CRT (1) W5CRT (1) U5CRT (1) Blue 7 7/8
YA6CL6-BOX 1 2.15MY29-11 (1) X5CRT (1) X5CRT (1) UBCABT (1)
YA6CL6-45 2 1/2.75.81.121.92MRC840 (1) X8CART (1) X8CART (1)
YA6CL6-90 3 1.30Y2MR (1)
YA5CL-BOX 1 1.65Y644M (1) W5CRT (1) W5CRT (1)
YA5CL-45 2 #5 AWG 1/4.44.81.071.51W5CVT (1) X5CRT (1) U5CRT (1) Blue 7 7/8
YA5CL-90 3 .81X5CRT (1) W5CVT (1)
YA4CL-BOX 1 1.74
YA4CL-45 2 1/4.50.81.091.44
YA4CL-90 3 .84
YA4CL1-BOX 1 1.58
YA4CL1-45 2 8-10 .50.81.091.28
YA4CL1-90 3 .75
YA4CL3-BOX 1 1.92W4CVT (1) W4CVT (1) U4CRT (1)
YA4CL3-45 2 #4 AWG 5/16.58.81.081.68W4CRT (1) W4CRT (1) Gray 8 7/8
YA4CL3-90 3 .96X4CRT (1) X4CRT (1) U6CABT (1)
YA4CL4-BOX 1 1.92
YA4CL4-45 2 3/8.58.81.081.68
YA4CL4-90 3 1.08
YA4CL6-BOX 1 2.20Y1MR (1)
YA4CL6-45 2 1/2.71.81.062.02MY29-3 (1)
YA4CL6-90 3 1.32MY29-11 (1)
YA3CL 1 1.88MRC840 (1)
YA3CL-45 2# 3 STR 25 5/16.55.88.091.76Y2MR (2) W3CRT (1) W3CRT (1) U3CRT (1)
White
9 15/16
YA3CL-90 3# 2 SOL .98Y644M (1)
YA2CL2-BOX 1 1.88
YA2CL2-45 2 1/4.61.88.111.55
YA2CL2-90 3 .89
YA2CL-BOX 1 1.93
YA2CL-45 2 5/16.61.88.111.62W2CVT (1) W2CVT (1)
YA2CL-90 3#2 AWG 35 1.01W2CRT (1) W2CRT (1) U2CRT (1)
Brown
10 15/16
YA2CL4-BOX 1 2.06X2CRT (1) X2CRT (1)
YA2CL4-45 2 3/8.61.88.111.74
YA2CL4-90 3 1.14
YA2CL6-BOX 1 2.32
YA2CL6-45 2 1/2.73.88.092.17
YA2CL6-90 3 1.37
YA1CL2 1 1.81
YA1CL2-45 2 1/4.68.88.101.70
YA1CL2-90 3 .91
YA1CL-BOX 1 1.94Y1MR (1)
YA1CL-45 2 5/16.68.88.011.82MY29-3 (1) W1CVT (1) W1CVT (1)
YA1CL-90 3#1 AWG 50 1.03MY29-11 (1)
W1CRT-1 (1) W1CRT-1 (1)
U1CRT-1 (1)
Green
11 15/16
YA1CL4-BOX 1 2.06MRC840 (1)
X1CRT-1 (1) X1CRT-1 (1)
U4CABT (1)
YA1CL4-45 2 3/8.68.88.101.95Y644M (1)
YA1CL4-90 3 1.16
YA1CL6-BOX 1 2.37
YA1CL6-45 2 1/2.73.88.092.22
YA1CL6-90 3 1.40
BURNDY
Compression
C-8
ONE HOLE HYLUG™
CODE CONDUCTOR
STANDARD BARREL
(CONTINUED)
* Use P-UADP-1 adapter with "U" dies in Y46 HYPRESS™.
** P-RT die sets for use in Y46 HYPRESS™ only, P-UADP-1
adapter not required.
B
B
B
TTT
L
45°
90°
L
L
Fig. 2 Fig. 3
Fig. 1
Conductor Installation T ooling
Stud Figure Mechanical Hydraulic Wire
*** Hole Tongue Dimensions Dieless MD6, OUR840 BCT500HS Y35,Y39,Y750 Color Die Strip
Catalog Number Fig # AWG MM2Size Width (B) (T) (L) (# of crimps) MD7-34R Y500CTHS
Y46, BAT35, BAT750
Code Index Length
YA25L2-BOX 1 1.84
YA25L2-45 2 1/4.75.88.121.76
YA25L2-90 3 .94
YA25L4-BOX 1 2.09
YA25L4-45 2 3/8.75.88.122.01W25VT (2) W25VT (2) U25RT (1)
YA25L4-90 31/0 AWG 1.19W25RT (2) W25RT (2)
Pink
12 15/16
YA25L6-BOX 1 2.34X25RT (2) X25RT (2) U2CABT (1)
YA25L6-45 2 1/2.75.88.122.26
YA25L6-90 3 1.44
YA25L-BOX 1 1.96
YA25L-45 2 5/16.88.88.121.88
YA25L-90 3 1.07
YA26L2-BOX 1 1.94
YA26L2-45 2 1/4.83.94.121.78
YA26L2-90 3 .96
YA26L3-BOX 1 2.06
YA26L3-45 2 5/16.83.94.121.91
YA26L3-90 3 1.09
YA26L-BOX 1 2.19
YA26L-45 2 3/8.83.94.122.03
YA26L-90 3 1.21W26VT (2) W26VT (2)
YA26L60 1 2/0 AWG 70 2.96W26RT (2) W26RT (2) U26RT (1)
Black
13 1
YA26L60-45 2 3/4.96.94.122.77MY29-3 (1) X26RT (2) X26RT (2)
YA26L60-90 3 1.89MY29-11 (1)
YA26L6-BOX 1 2.44MRC840 (2)
YA26L6-45 2 1/2.83.94.122.28Y644M (1)
YA26L6-90 3 1.46
YA26L7-BOX 1 2.69
YA26L7-45 2 5/8.88.94.112.50
YA26L7-90 3 1.71
YA26LNT516 1 5/16.62.94.132.62
YA27L2-BOX 1 2.04
YA27L2-45 2 1/411.00.131.91
YA27L2-90 3 .99
YA27L3 1 2.16
YA27L3-45 2 5/16.911.00.132.03
YA27L3-90 3 1.12W27VT (2) W27VT (2)
YA27L4-BOX 1 3/0 AWG 2.29W27RT (2) W27RT (2) U27RT (1)
Orange
14 1-1/16
YA27L4-45 2 3/8.911.00.131.91X27RT (3) X27RT (3)
YA27L4-90 3 .99
YA27L-BOX 1 2.54
YA27L-45 2 1/2.911.00.132.41
YA27L-90 3 1.49
YA27LNT38 3/8.761.00.12
YA28L17-BOX 1 2.71
YA28L17-45 2 5/81.02.88.142.64W28VT (2) W28VT (2)
YA28L17-90 3 4/0 AWG 1.79W28RT (2) W28RT (2) U28RT (1)
Purple
15 1-1/8
YA28L2-BOX 1 1.96X28RT (3) X28RT (3)
YA28L2-45 2 1/41.02.88.141.89
*** The MM2conductor sizes listed are the recommendations
for Class 2 conductor.
See tooling section of this catalog for complete tool and
die listings.
For applications greater than 2000 Volts, consult cable
manufacturer for voltage stress relief instructions.
BURNDY
Compression
C-9
ONE HOLE HYLUG™
CODE CONDUCTOR
STANDARD BARREL
(CONTINUED)
*** The MM2conductor sizes listed are the recommendations
for Class 2 conductor.
See tooling section of this catalog for complete tool and die
listings.
B
B
B
TTT
L
45°
90°
L
L
Fig. 2 Fig. 3
Fig. 1
Conductor Installation T ooling
Stud Figure Mechanical Hydraulic Wire
*** Hole Tongue Dimensions Dieless MD6, OUR840 BCT500HS Y35,Y39,Y750 Color Die Strip
Catalog Number Fig # AWG MM2Size Width (B) (T) (L) (# of crimps) MD7-34R Y500CTHS
Y46, BAT35, BAT750
Code Index Length
YA28L2-90 3 1/41.02.88.141.04
YA28L3-BOX 1 2.08
YA28L3-45 2 5/161.02.88.142.01
YA28L3-90 3 1.16
YA28L4-BOX 1 2.21
YA28L4-45 2 3/81.02.88.142.14MY29-3 (1) W28VT (2) W28VT (2)
YA28L4-90 34/0 AWG 1.29MY29-11 (1) W28RT (2) W28RT (2) U28RT (1)
Purple
15 1-1/8
YA28L56-BOX 1 2.90MRC840 (2) X28RT (2) X28RT (3)
YA28L56-45 2 3/41.05.88.132.81Y644M (1)
YA28L56-90 3 1.97
YA28L-BOX 1 2.46
YA28L-45 2 1/21.02.88.142.39
YA28L-90 3 1.54
YA28LNT38 1 3/876.88.162.79
YA29L2-BOX 1 2.17
YA29L2-45 2 1/41.111.06.162.07
YA29L2-90 3 1.08
YA29L4-BOX 1 2.42
YA29L4-45 2 3/81.111.06.162.32
YA29L4-90 3 1.33
YA29L7-BOX 1 2.30MY29-3 (1) W29VT (2)
YA29L7-45 2 250 kcmil 5/161.111.06.162.20MY29-11 (1) W29VT (2) W29RT (2) U29RT (1)
Yellow
16 1-1/8
YA29L7-90 3 1.20Y644M (1) X29RT (4) X29RT (4)
YA29LTC78-BOX 1 3.36
YA29LTC78-45 2 7/81.111.06.143.23
YA29LTC78-90 3 2.26
YA29LNT38 3/8961.06.162.96
YA29L-BOX 1 2.67
YA29L-45 2 1/21.111.06.162.57
YA29L-90 3 1.58
YA30L-BOX 1 2.69
YA30L-45 2 1/21.201.03.162.60
YA30L-90 3 1.61
YA30L1-BOX 1 2.31
YA30L1-45 2 5/161.201.03.162.22
YA30L1-90 3 1.24
YA30L24-BOX 1 2.44
YA30L24-45 2 3/81.201.03.162.35W30VT (2) W30VT (2) U30RT (2)
White
17 1-1/16
YA30L24-90 3 300 kcmil 150 1.36W30RT (2) U28ART (2)
YA30L27-BOX 1 3.37Y644M (1)
YA30L27-45 2 7/81.201.03.163.29
YA30L27-90 3 2.30
YA30L28-BOX 13/41.201.03.163.12
YA30L7-BOX 1 2.94
YA30L7-45 25/81.201.03.162.85
YA30L7-90 3 1.86
YA31L-BOX 1 2.75W31VT (2) U31RT (2)
YA31L-45 2 350 kcmil 185 1/21.291.06.182.75W31VT (2)
Red
18 1-3/16
YA31L-90 3 1.65W31RT (2) U29ART (2)
* Use P-UADP-1 adapter with "U" dies in Y46 HYPRESS™.
** P-RT die sets for use in Y46 HYPRESS™ only, P-UADP-1
adapter not required.
For applications greater than 2000 Volts, consult cable
manufacturer for voltage stress relief instructions.
BURNDY
Compression
C-10
ONE HOLE HYLUG™
CODE CONDUCTOR
STANDARD BARREL
(CONTINUED)
* Use P-UADP-1 adapter with "U" dies in Y46 HYPRESS™.
** P-RT die sets for use in Y46 HYPRESS™ only, P-UADP-1
adapter not required.
B
B
B
TTT
L
45°
90°
L
L
Fig. 2 Fig. 3
Fig. 1
Conductor Installation T ooling
Stud Figure Mechanical Hydraulic Wire
*** Hole Tongue Dimensions Dieless MD6, OUR840 BCT500HS Y35,Y39,Y750 Color Die Strip
Catalog Number Fig # AWG MM2Size Width (B) (T) (L) (# of crimps) MD7-34R Y500CTHS
Y46, BAT35, BAT750
Code Index Length
YA31L11 1 2.50
YA31L11-45 2 3/81.291.06.182.42
YA31L11-90 3 1.40
YA31L36-BOX 1 4.02
YA31L36-45 2350 kcmil 185 7/81.291.06.184.02W31VT (2) U31RT (2)
YA31L36-90 3 3.94W31VT (2) W31RT (2) U29ART (2)
Red
18 1-3/16
YA31L7-BOX 1 3.00
YA31L7-45 2 5/81.291.06.183.00
YA31L7-90 3 1.90
YA31LNT38 3/8961.06.183.37
YA32L-BOX 1 3.18
YA32L-45 2 5/81.381.19.193.08
YA32L-90 3 1.95
YA32L1-BOX 1 2.93
YA32L1-45 2 1/21.401.19.192.83
YA32L1-90 3 400 kcmil 1.70W32VT (2) W32VT (2) U32RT (2)
Blue
19 1-1/4
YA32L14-BOX 1 2.68W32RT (2) U30ART (2)
YA32L14-45 2 3/81.381.19.192.58
YA32L14-90 3 1.45
YA32LTC78-BOX 1 3.62
YA32LTC78-45 2 7/81.401.19.193.52
YA32LTC78-90 3 2.38
YA33L-BOX 1 3.57W33VT (2)
YA33L-45 2 450 kcmil 5/81.481.50.213.30W33VT (2) U33RT (2)
Gray
326 1-9/16
YA33L-90 3 2.00W33RT (2)
YA34L-BOX 1 3.37
YA34L-45 2 5/81.551.27.233.30Y644M (1)
YA34L-90 3 2.03
YA34L20-BOX 1 4.05
YA34L20-45 211.551.27.233.99
YA34L20-90 3 2.72
YA34L37-BOX 1 2.87
YA34L37-45 2 3/81.551.27.232.80
YA34L37-90 3 500 kcmil 240 1.53W34VT (2) W34VT (2) U34RT (2)
Brown
20 1-7/16
YA34L6-BOX 1 3.12W34RT (2) U31ART (2)
YA34L6-45 2 1/21.551.27.233.05
YA34L6-90 3 1.78
YA34L8-BOX 1 3.55
YA34L8-45 2 3/41.551.27.233.49
YA34L8-90 3 2.22
YA34L9-BOX 1 3.80
YA34L9-45 2 7/81.551.27.233.74
YA34L9-90 3 2.47
YA35L-BOX 1 3.81
YA35L-45 2 550 kcmil 5/81.651.69.253.67- - U35RT (2)
Yellow
21 1-3/4
YA35L-90 3 2.08
YA36L11-BOX 1 1/21.741.38.273.29
YA36L-BOX 1 3.72
YA36L-45 2600 kcmil 300 5/81.741.38.273.51- - U36RT (2)
Green
22 1-3/4
YA36L-90 3 2.11
*** The MM2conductor sizes listed are the recommendations
for Class 2 conductor.
See tooling section of this catalog for complete tool and
die listings.
For applications greater than 2000 Volts, consult cable
manufacturer for voltage stress relief instructions.
BURNDY
Compression
C-11
ONE HOLE HYLUG™
CODE CONDUCTOR
STANDARD BARREL
(CONTINUED)
* Use P-UADP-1 adapter with "U" dies in Y46 HYPRESS™.
** P-RT die sets for use in Y46 HYPRESS™ only, P-UADP-1
adapter not required.
B
B
B
TTT
L
45°
90°
L
L
Fig. 2 Fig. 3
Fig. 1
Conductor Installation T ooling
Stud Figure Mechanical Hydraulic Wire
*** Hole Tongue Dimensions Dieless MD6, OUR840 BCT500HS Y35,Y39,Y750 Color Die Strip
Catalog Number Fig # AWG MM2Size Width (B) (T) (L) (# of crimps) MD7-34R Y500CTHS
Y46, BAT35, BAT750
Code Index Length
YA36LTC78-BOX 1 3.97
YA36LTC78-45 2 600 kcmil 300 7/81.741.38.273.95--
U36RT (2)
Green
22 1-3/4
YA36LTC78-90 3 2.55U32ART (2)
YA37L-BOX 1 3.57
YA37L-45 2650 kcmil 5/81.801.39.273.55- - U37RT (2)
Orange
23
1-15/16
YA37L-90 3 2.14
YA37L1-BOX 1 3.76
YA38L-BOX 1 3.66
YA38L-90 2 700 kcmil 5/81.841.45.273.60- - U38RT (2)
Pink
400
1-15/16
YA38L-45 3 2.15
YA39L-BOX 1 3.67
YA39L-45 2 5/81.911.42.273.61
YA39L-90 3 2.17
YA39L2-BOX 1 4.10
YA39L2-45 2 7/81.911.42.274.05
YA39L2-90 3 2.61U39RT (2)
YA39L9-BOX 1 750 kcmil 4.85- - P39RT (2)
Black
24
1-15/16
YA39L9-45 2 1-1/41.911.42.274.80**
YA39L9-90 3 3.36
YA39LNT38 3/81.121.42.274.70
YA39L6-BOX 1 3.41
YA39L6-45 2 1/21.911.42.273.36
YA39L6-90 3 1.92
YA40L-BOX 1 3.81
YA40L-45 2 800 kcmil 400 5/81.981.42.303.69Y644M (1) - - P40RT(3)
Orange
25
1-15/16
YA40L-90 3 2.21**
YA41L-BOX 1 4.15
YA41L-45 2 850 kcmil 5/82.011.88.314.03-- -
Gold
26
1-15/16
YA41L-90 3 2.23
YA44L-BOX 1 4.04
YA44L-45 2 5/82.191.65.334.01
YA44L-90 3 1000 kcmil 500 2.32- - P44RT(3)
White
27
1-15/16
YA44L2-BOX 1 1/22.491.65.333.98**
YA44L23-BOX 112.191.65.334.73
YA-45L-BOX 1 4.68
YA-45L-45 2 1250 kcmil 3/42.462.00.384.64- - P45RT(3)
Yellow
29
2-1/16
YA-45L-90 3 2.62**
YA-453L-BOX 1 4.71
YA-453L-45 2 1300 kcmil 3/42.532.00.394.68-- -
Orange
30
2-1/16
YA-453L-90 3 2.65
YA46L-BOX 1 4.78--
YA46L-45 2 1500 kcmil 3/42.692.00.404.75- - P46RT (3)
Green
31
2-1/16
YA46L-90 3 2.71-- **
YA47L-BOX 1 5.05-- -
YA47L-45 2 1750 kcmil 3/42.902.19.425.00-- -
Gray
33
2-1/4
YA47L-90 3 2.79-- -
YA48L-BOX 1 5.19-- -
YA48L-45 2 2000 kcmil 3/43.102.25.465.19-- -
Brown
34
2-1/4
YA48L-90 3 2.89-- -
*** The MM2conductor sizes listed are the recommendations
for Class 2 conductor.
See tooling section of this catalog for complete tool and die
listings.
For applications greater than 2000 Volts, consult cable