Universal AC input / Full range
No load power consumption<0.3W
Energy efficiency Level Ⅴ
Comply with EISA 2007, NRCan, AU/NZ MEPS and EU ErP
2 pole AC inlet IEC320-C8
Class power (without earth pin)Ⅱ
Protections: Short circuit / Overload / Over voltage
Pass LPS
Fully enclosed plastic case
LED indicator for power on
2 years warranty
SPECIFICATION
ORDER NO.
SAFETY MODEL NO.
DC VOLTAGE Note.2
RATED CURRENT
CURRENT RANGE
RATED POWER (max.)
RIPPLE & NOISE (max.) Note.3
OUTPUT
SETUP, RISE, HOLD UP TIME
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT
INPUT
ENVIRONMENT
INRUSH CURRENT (max.)
LEAKAGE CURRENT(max.)
SAFETY STANDARDS
SAFETY &
EMC
(Note. 7)
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSION
OTHERS
NOTE
PACKING
PROTECTION
5V
GS18B05
GS18B05-P1J GS18B09-P1J GS18B15-P1J GS18B24-P1J GS18B48-P1JGS18B07-P1J GS18B12-P1J GS18B18-P1J GS18B28-P1J
7.5V
GS18B07
9V
GS18B09
12V
GS18B12
15V
GS18B15
18V
GS18B18
24V
GS18B24
28V
GS18B28
48V
GS18B48
3.0A 2.0A 2.0A 1.50A 1.20A 1.0A 0.75A 0.64A 0.375A
0 ~ 3.0A 0 ~ 2.0A 0 ~2.0A 0 ~ 1.20A 0 ~ 1.0A 0 ~ 0.75A
50mVp-p 80mVp-p 80mVp-p 80mVp-p 100mVp-p 150mVp-p 180mVp-p 240mVp-p 240mVp-p
VOLTAGE TOLERANCE Note.4
LINE REGULATION Note.5
LOAD REGULATION Note.6
±5.0% ±5.0% ±5.0% ±3.0% ±3.0% ±3.0% ±2.0% ±2.0% ±2.0%
±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0%
±5.0% ±5.0% ±5.0% ±3.0% ±3.0% ±3.0% ±2.0% ±2.0% ±2.0%
500ms, 20ms, 50ms/230VAC 500ms, 20ms, 15ms/115VAC at full load
90 ~ 264VAC 135 ~ 370VDC
47 ~ 63Hz
0.5A / 100VAC
45A / 230VAC
0.25mA / 240VAC
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:4242VDC
I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH℃
500Khrs min. MIL-HDBK-217F(25 )℃
0 ~ +50 (Refer to "Derating Curve")℃
20% ~ 90% RH non-condensing
-20 ~ +85 , 10 ~ 95% RH℃
±℃℃0.03% / (0 ~ 40 )
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
79*54*33mm (L*W*H)
210g ; 60pcs / 13.5kg / CARTON
CONNECTOR
PLUG
CABLE
See page 2 ; Other type available by customer requested
See page 2 ; Other type available by customer requested
15W 15W 18W 18W
0 ~ 1.50A
18W 18W 18W 18W
0 ~ 0.64A
18W
0 ~ 0.375A
1.All parameters are specified at 230VAC input, rated load, 25 70% RH ambient. ℃
2.DC voltage: The output voltage set at point measure by plug terminal & 50% load.
3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
4.Tolerance: includes set up tolerance, line regulation, load regulation.
5.Line regulation is measured from low line to high line at rated load.
6.Load regulation is measured from 20% to 100% rated load.
7.The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the
EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)
18WAC-DC Industrial Adaptor GS18B series
■Features :
OVERLOAD
OVER VOLTAGE
110 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
105 ~ 135% rated output voltage
Protection type : Clamp by zener diode, output short
UL60950-1, CSA C22.2, TUV EN60950-1 , EAC TP TC 004, CCC GB4943 approved
79.5% 82% 83% 85% 85% 85% 86% 86.5% 87%
File Name:GS18B-SPEC 2018-01-22
Compliance to EN55032 Class B EN61000-3-2,3, FCC PART 15 / CISPR22 class B
, EAC TP TC 020
, , GB9254, GB17625.1
Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A, EAC TP TC 020
EMC IMMUNITY
EMC EMISSION