313
process
yellow
3405
1797
1375
116
2607
652
242
2985
375
240
Embedded Power for
Business-Critical Continuity
NLP65 Series
Single, dual,
and triple output
Special Features
• UniversalInput
• 3”x5”footprint
• Lowprolets1Uapplications
• EN61000-3-2compliance
option (HCC)
• Overvoltageandshortcircuit
protection
•65Wwithfreeairconvection
cooling
• EN55022,EN55011conducted
emissionslevelB
• EN61000-4-2,-3,-4,-5,-6
immunity compliant
• RoHScompliant
• LPX80enclosurekitavailable
• 2yearwarranty
Total Power: 65-75W
Input Voltage: 85-264Vac
120-370Vdc*
# of Outputs: Single, dual,
triple
Safety
• VDE0805/EN60950-1
FileNo.1040100-3336-0096
• LicenseNo.114404
• UL 60950-1
• cUL 60950-1
• CCC 60950-1
• CE LVDDirective
*NLP65-76xxversiononly
Rev.03.07.12_102
NLP65 Series
1 of 4
ElectricalSpecications
Input
Inputvoltagerange: Universalinput
(seeNote2)
NLP65-76xxversiononly
85-264Vac
120-370Vdc
Inputfrequencyrange: 47-63Hz
Inputcurrent:
(cold start) 120Vac
230Vac
17Amax.
32Amax
Safety ground
leakagecurrent: 120Vac,60Hz
230Vac,50Hz
0.7mA
1.4mA
Inputcurrent: 120Vac,withPFC
230Vac,withPFC
120Vac,withoutPFC
230Vac,withoutPFC
1.4A
0.51Arms
1.40Arms
0.80Arms
Inputfuse: UL/IEC127 S3.15A,250VacInliveandneutral
Output
Totalregulation:
(line and load) Main output
Auxiliaryoutputs
±2.0%
±5.0%
Risetime: Atturn-on 1.0s,max
Transientresponse: Main output
25%step
at0.1A/µs
5.0%or250mV
max.dev.,1msmax.
recoveryto1%
Temperaturecoefcient: ±0.02%/°C
Overvoltageprotection: Main outputs 125%,±10%
Shortcircuitprotection: Cyclic operation Continuous
Minimumoutputcurrent: Single and multiple (SeeNote6)
Rev.03.07.12_102
NLP65 Series
2 of 4
Embedded Power for
Business-Critical Continuity
313
process
yellow
3405
1797
1375
116
2607
652
242
2985
375
240
EnvironmentalSpecications
Allspecicationsaretypicalatnominalinput,fullloadat25°Cunlessotherwisestated.
Output Power (Watts)
32W
65W
75W
20 CFM FORCED AIR COOLING
38W
NATURAL
CONVECTION
COOLING
DERATING CURVE
0°C 10°C 20°C 30°C 40°C 50°C 60°C 70°C
Thermalperformance: Operating
(Seederatingcurve)
0°Cto+70°C
(Seenotes1,3,10) Non-operating -40°Cto+85°C
50°C-70°Cambient,
convectioncooled
Derateto50%load
0°Cto50°C,ambient,
convectioncooled
65W
0°Cto50°C,ambient
20CFMforcedair(SeeNote10)
75W
Peak(0°Cto50°C,60s) See table
Relativehumidity: Non-condensing 5to95%RH
Altitude: Operating 10,000feetmax.
Non-operating 30,000feetmax.
Vibration(SeeNote5): 5-500Hz 2.4Grmspeak
Shock perMIL-STD-810E 516.4PartIV
EMCCharateristics(11,12)
Conductedemissions: EN55022,FCCpart15 LevelB
ESDair: EN61000-4-2,level3 Perf.criteria1
ESDcontact: EN61000-4-2,level4 Perf.criteria1
Surge: EN61000-4-5,level3 Perf.criteria1
Fasttransients: EN61000-4-4,level3 Perf.criteria1
Radiatedimmunity: EN61000-4-3,level3 Perf.criteria2
Conductedimmunity: EN61000-4-6,level3 Perf.criteria2
GeneralSpecications
Hold-uptime: 120Vac,60Hz
230Vac,50Hz
16ms@65W
78ms@65W
Efciency: 120Vac,65W 72%typical
Isolationvoltage: Input/output
Input/chassis
3000Vac
1500Vac
Switchingfrequency: Fixed 100kHz,±5kHz
Approvalsandstandards:
(seeNotes9,13) EN60950-1,IEC60950-1
Weight: 283g(10oz)
MTBFdemonstrated: MIL-HDBK-217F 150,000hoursmin
Rev.03.07.12_102
NLP65 Series
3 of 4
Embedded Power for
Business-Critical Continuity
313
process
yellow
3405
1797
1375
116
2607
652
242
2985
375
240
1 Naturalconvectioncooling.ModelsNLP65-X629J,NLP65-X608J,NLP65-
X610Jmustnotexceed62.5Wattscontinuousoutputpowerwithnatural
convection.ModelNLP65-X620Jnottoexceed65Wattscontinuousoutput
powerwithnaturalconvection.ModelNLP65-3322Jmustnotexceed60Watts
continuousoutputpowerwithnaturalconvection.
2 Whentheinputvoltageislessthan90Vactheoperatingtemperaturerangeis
0°Cto+40°C.Therippleandregulationspecicationsmaynotbemet.
3 Peakoutputcurrentlastinglessthan60secondswithdutycyclelessthan5%.
Duringpeakloading,outputvoltagemayexceedtotalregulationlimits.
4 Figureispeak-to-peakforconvectionpowerrating.Outputnoise
measurementsaremadeacrossa20MHzbandwidthusinga6inchtwisted
pair,terminatedwitha10µFelectrolyticcapacitoranda0.1µFceramic
capacitor.
5 Threeorthogonalaxes,randomvibration10minutesforeachaxes,2.4Grms5
Hzto500Hz.
6 Aminimumloadonthemainoutputisrequiredforproperstartup.For
multipleoutputsandsingle+5Voutput,theminimumloadonthe+5Vis
0.2A.Forsingleoutputsgreaterthan+5Vtheminimumloadis0.1A.To
maintainstatedregulationthen:
for single output units
I≥0.2A
for multiple output units
0.25 ≤ I(A)/I(B) ≤5,forI(A)≥0.2A.
7 Foroptimumreliability,nopartoftheheatsinkshouldexceed120oC, and no
semiconductorcasetemperatureshouldexceed130oC.
8 CAUTION:Allowaminimumof1secondafterdisconnectinglinepowerwhen
makingthermalmeasurements.
9 Thisproductisonlyforinclusionbyprofessionalinstallerswithinother
equipmentandmustnotbeoperatedasastandaloneproduct.
10 Maximumcontinuousoutputpowerforallmultipleoutputmodelsmustnot
exceed75Watts(70wattsforNLP65-3322J)with20CFMforcedaircooling.
11 ConductedemissionstestingwereperformedusingthestandardEN55022set-
upwithastandaloneNLP65unitplacedonagroundedmetalplatewithaline
chokeontheACinputandgroundwires(i.e.thewiresareloopedthroughan
EMIsuppressiontoroid).
Forsystemcomplianceitisusuallynecessarytoinstallan‘off-the-shelf’AC
inletwithanintegrallinelterinthesystemchassisortoinstallalinechoke
ontheinputwiresascloseaspossibletoACentrypointofthesystemchasssis.
PleasecontacttheapplicationsgroupforassistancewithEMIcompliance.
12 TheNLP65unitswiththesufx‘G’isthegroundpinandgroundchokeoption.
J2,L6andJP10areincluded.J2isasafetyagencyapprovedgroundingpin,L6
isagroundchokeandJP10isajumper.Thisoptionisintendedforuseinnon-
metallicchassisapplicationswheregroundingisnotpossibleviathemounting
screws.ThegroundchokeisprovidedtoassistsystemEMCcompliance.When
performingconductedemissionstestingonstandaloneunits,the‘G’option
isrequiredtomeetlevelB.Toordersimplyaddthesufx‘G’tothestandard
modelnumber,e.g.NLP65-7608GJ,NLP65-9608GJ.Thisoptionisavailablefor
boththePFCandnon-PFCversions.
13 Allmodelsrequireaminimummountingstand-offof0.25inches(6.35mm)in
theenduseproduct.
14 TheNLP65-9608Jisavailablewithanenclosure.Toorderanenclosedversion,
useNLP65-9608EJ.
15 NoPFCversion,EN61000-3-2isnotapplicabletothismodel.
16 The‘J’sufxindicatesthatthesepartsarePb-free(RoHS6/6)compliant.
17 NOTICE:Somemodelsdonotsupportalloptions.Pleasecontactyourlocal
EmersonNetworkPowerrepresentativeorusetheon-linemodelnumber
searchtoolathttp://www.Emerson.com/EmbeddedPower
ModelNumberingOptions
a) TheenclosureversionNLP65-9608EJincludes:IECconnector,on/offswitch,
wireharnessoutputconnectorandttedcover.Toorder,pleaseaddthesufx
‘E’themodelnumber.SeeNLP65enclosurefordetails.
b) ASafetyearthgroundpinandgroundchokeareavailableasanoption.
Toorder,pleaseaddthesufx‘G’themodelnumber,e.g.NLP65-X608GJ.
c) Toorderanenclosurekit(untted),orderthepartnumberLPX80.
Output
Voltage
OutputCurrent Ripple(4) Total
Regulation(6)
Non-harmonic
Corrected
Harmonic
Corrected
Ground
Pin(12,14,17)
Max(1) Peak(3) Fan(10)
+5V(IA) 7.5A 9.1A 8A 50mV ±2.0% NLP65-7608J NLP65-9608J(a) NLP65-X608GJ
+12V(IB) 2.5A 3.3A 3A 150mV ±5.0%
–12V 0.65A 0.81A 0.8A 120mV ±5.0%
+5V(IA) 7.5A 9.1A 8A 50mV ±2.0% NLP65-7610J NLP65-9610J NLP65-X610GJ
+15V(IB) 2.2A 2.9A 2.5A 150mV ±5.0%
–15V 0.65A 0.85A 0.8A 150mV ±5.0%
+5V 7.0A 9.1A 8.0A 50mV ±2.0% NLP65-3322J(15)
+24V 1.5A 2.6A 2.0A 240mV ±5.0%
+12V 0.7A 1.0A 1.0A 120mV ±5.0%
+5V(IA) 7A 9.1A 8A 50mV ±2.0% NLP65-7620J NLP65-9620J NLP65-X620GJ
+24V(IB) 2A 2.6A 2A 240mV ±5.0%
+5V(IA) 7A 9.1A 8A 50mV ±2.0% NLP65-7629J NLP65-9629J NLP65-X629GJ
+12V(IB) 2.5A 3.3A 3A 150mV ±5.0%
+5V 10A 13A 12A 50mV ±2.0% NLP65-7605J NLP65-9605J NLP65-X605GJ
+12V 5.4A 7A 6.5A 120mV ±2.0% NLP65-7612J NLP65-9612J NLP65-X612GJ
+24V 2.7A 3.5A 3.5A 240mV ±2.0% NLP65-7624J NLP65-9624J NLP65-X624GJ
Notes
313
process
yellow
3405
1797
1375
116
2607
652
242
2985
375
240
Embedded Power for
Business-Critical Continuity
Rev.03.07.12_102
NLP65 Series
4 of 4
C19
ALL DIMENSIONS IN INCHES (mm)
5.00
(127.00)
MAXIMUM COMPONENT
HEIGHT 1.26 (32.00)
N1
L
J3
J1
J2
6
4.550
(115.57)
2.550
(64.770)
TOLERANCE: .xxx 0.005"
.xx 0.02"
0.225
(5.715)
3.00
(76.20)
3
Mounting
Hole Diameter
0.156 (4.00)
T1
1
MechanicalDrawing Americas
5810VanAllenWay
Carlsbad,CA92008
USA
Telephone:+17609304600
Facsimile: +17609300698
Europe (UK)
WaterfrontBusinessPark
MerryHill,Dudley
WestMidlands,DY51LX
UnitedKingdom
Telephone:+44(0)1384842211
Facsimile: +44(0)1384843355
Asia (HK)
14/F,LuPlaza
2WingYipStreet
KwunTong,Kowloon
HongKong
Telephone:+85221763333
Facsimile: +85221763888
Forglobalcontact,visit:
www.Emerson.com/EmbeddedPower
techsupport.embeddedpower@
emerson.com
Whileeveryprecautionhasbeentakentoensure
accuracyandcompletenessinthisliterature,Emerson
NetworkPowerassumesnoresponsibility,anddisclaims
allliabilityfordamagesresultingfromuseofthis
informationorforanyerrorsoromissions.
EmersonNetworkPowerandtheEmerson
NetworkPowerlogoaretrademarksandservice
marksofEmersonElectricCo.
©2011EmersonElectricCo.
EmersonNetworkPower.com
Embedded Computing
Embedded Power
Monitoring
OutsidePlant
PowerSwitching&Controls
Precision Cooling
Racks&IntegratedCabinets
Services
Surge Protection
Emerson Network Power.
Thegloballeaderinenabling
business-criticalcontinuity.
ACPower
Connectivity
DCPower
Pin Connections
J1
Pin1 ACLine
Pin2 NoPin
Pin3 ACNeutral
J2 (On ‘G’ Suffic Only)
Pin1 SafetyGround
OutputPinConnections
J3 SINGLE DUAL TRIPLE
Pin1 V(A) V(B) V(B)
Pin2 V(A) V(A) V(A)
Pin3 V(A) V(A) V(A)
Pin4 Return Return Return
Pin5 Return Return Return
Pin6 Return N/C V(C)
InputandOutput
Connectors
Mating Connectors
AC(J1) Molex26-60-4030type
orequivalent
Molex09-50-3031orequivalentwithMolex
08-50-0105orequivalentcrimpterminals
DC(J3) Molex26-60-4060or
equivalent
Molex09-50-3061withMolex2478phos-
phorbronzecrimpterminalsorequivalent.
Note:TheinputandoutputconnectorsarethesameasthoseusedonNFS40,NFN40,
NAL40,NAN40andNLP40.