142 PCB Relay G5SB
■Contact Ratings
Note: P level: λ60=0.1 x 10–6 operation (with an operating frequency of 120 operations/min.)
■Characteristics
Note: 1. The data shown above are initial values.
2. The contact resistance is possible with 1 A applied at 5 VDC using a fall-of-potential method.
3. The operating time is possible with the operating voltage imposed with no contact bounce at an ambient temperature of 23°C.
4. The insulation resistance is possible between coil and contacts and between contacts of the same polarity at 500 VDC.
5. The electrical life data items shown are possible at 23°C.
■Approved Standards
UL Recognized (File No. E41515) / CSA Certified (File No. LR31928) - - Ambient Temp = 40°C
Note: Electrical durability tests are performed at 70°C.
Load Resistive load
Rated load 3 A (NO)/3 A (NC) at 125 VAC
5 A (NO)/3 A (NC) at 125 VAC
5 A (NO) at 250 VAC
3 A (NC) at 250 VAC
5 A (NO)/3 A (NC) at 30 VDC
Contact material Ag alloy
Rated carry current 5 A (NO)/3 A (NC)
Max. switching voltage 250 VAC, 30 VDC
Max. switching current 5 A (NO)/3 A (NC)
Max. switching capacity 1,250 VA, 150 W (NO)
750 VA, 30 W (NC)
Min. permissible load 10 mA at 5 VDC
Contact resistance (See note 2.) 100 mΩ max. initial
Operate time (See note 3.) 10 ms max.
Release time (See note 3.) 5 ms max.
Insulation resistance (See note 4.) 1,000 MΩ min.
Dielectric strength 4,000 VAC, 50/60 Hz for 1 min between coil and contacts
1,000 VAC, 50/60 Hz for 1 min between contacts of same polarity
Impulse withstand voltage 8 kV (1.2 x 50 μs)
Vibration resistance Destruction:10 to 55 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Malfunction:10 to 55 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Shock resistance Destruction:1,000 m/s2 (approx. 100G)
Malfunction:Energized: 100 m/s2 (approximately 10G)
Non-energized: 100 m/s2 (approximately 10G)
Life expectancy (See note 5.) Mechanical: 5,000,000 operations (18,000 operations per hour)
Electrical: 200,000 operations: 3 A (NO)/3 A (NC) at 125 VAC resistive load
50,000 operations: 5 A (NO)/3 A (NC) at 125 VAC resistive load
50,000 operations: 5 A (NO) at 250 VAC resistive load
10,000 operations: 3 A (NC) at 250 VAC resistive load
10,000 operations: 5 A (NO)/3 A (NC) at 30 VDC resistive load
Switching frequency: 1,800 operations per hour
Ambient temperature Operating: –40°C to 70°C with no icing or condensation
Ambient humidity Operating: 5% to 85%
Weight Approx. 6.5 g
Model Coil ratings Contact ratings Number of test operations
G5SB 5 to 24 VDC 3 A, 125 VAC (resistive) NC only
2 A, 125 VAC (resistive) NC only
5 A, 250 VAC (resistive) NO only
3 A, 250 VAC (resistive) NO only
5 A, 30 VDC (resistive) NO only
6,000