INTEGRATED CIRCUITS I*CODE SL RC400 I*CODE Reader IC Product Specification Revision 3.1 Philips Semiconductors August 2004 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC SL RC400 CONTENTS 1 GENERAL INFORMATION ..................................................................................................................6 1.1 Scope ....................................................................................................................................................6 1.2 General Description...............................................................................................................................6 1.3 Features ................................................................................................................................................7 1.4 Ordering Information .............................................................................................................................7 2 BLOCK DIAGRAM ...............................................................................................................................8 3 PINNING INFORMATION .....................................................................................................................9 3.1 Pin Configuration...................................................................................................................................9 3.2 Pin Description ....................................................................................................................................10 4 PARALLEL INTERFACE....................................................................................................................12 4.1 Overview of Supported -Processor Interfaces ..................................................................................12 4.2 Automatic -Processor Interface Type Detection ...............................................................................12 4.3 4.3.1 4.3.2 4.3.3 Connection to Different -Processor Types ........................................................................................13 Separated Read/Write Strobe: Intel Type Compatible........................................................................13 Common Read/Write Strobe: Motorola Type Compatible...................................................................14 Common Read/Write Strobe and Hand-Shake Mechanism: EPP ......................................................15 5 SL RC400 REGISTER SET ................................................................................................................16 5.1 5.1.1 SL RC400 Registers Overview ...........................................................................................................16 Register Bit Behaviour.........................................................................................................................18 5.2 5.2.1 5.2.2 5.2.3 5.2.4 5.2.5 5.2.6 5.2.7 Register Description ............................................................................................................................19 Page 0: Command and Status ............................................................................................................19 Page 1: Control and Status .................................................................................................................27 Page 2: Transmitter and Control .........................................................................................................34 Page 3: Receiver and Decoder Control ..............................................................................................38 Page 4: RF-Timing and Channel Redundancy ...................................................................................44 Page 5: FIFO, Timer and IRQ- Pin Configuration ...............................................................................49 Page 7: Test Control ...........................................................................................................................55 5.3 SL RC400 Register Flags Overview ...................................................................................................59 5.4 5.4.1 5.4.2 5.4.3 Modes of Register Addressing ............................................................................................................62 Paging Mechanism..............................................................................................................................62 Dedicated Address Bus.......................................................................................................................62 Multiplexed Address Bus.....................................................................................................................62 6 MEMORY ORGANISATION OF THE EPROM .................................................................................63 6.1 Diagram of the EPROM Memory Organisation..................................................................................63 6.2 Product Information Field (Read Only)................................................................................................63 6.3 Register Initialisation Files (Read/Write) .............................................................................................64 2 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC SL RC400 6.3.1 6.3.2 6.3.3 Start Up Register Initialisation File (Read/Write).................................................................................64 Shipment Content of Start Up Register initialisation File ....................................................................65 Register Initialisation File (Read/Write)...............................................................................................66 7 FIFO BUFFER.....................................................................................................................................67 7.1 Overview..............................................................................................................................................67 7.2 7.2.1 Accessing the FIFO Buffer ..................................................................................................................67 Access Rules.......................................................................................................................................67 7.3 Controlling the FIFO-Buffer .................................................................................................................67 7.4 Status Information about the FIFO-Buffer ...........................................................................................68 7.5 Register overview FIFO Buffer ............................................................................................................69 8 INTERRUPT REQUEST SYSTEM .....................................................................................................70 8.1 8.1.1 Overview..............................................................................................................................................70 Interrupt Sources Overview.................................................................................................................70 8.2 8.2.1 8.2.2 Implementation of Interrupt Request Handling....................................................................................71 Controlling Interrupts and their Status.................................................................................................71 Accessing the Interrupt Registers .......................................................................................................71 8.3 Configuration of Pin IRQ .....................................................................................................................71 8.4 Register Overview Interrupt Request System .....................................................................................72 9 TIMER UNIT ........................................................................................................................................73 9.1 Overview..............................................................................................................................................73 9.2 9.2.1 9.2.2 9.2.3 9.2.4 9.2.5 Implementation of the Timer Unit ........................................................................................................74 Block Diagram .....................................................................................................................................74 Controlling the Timer Unit....................................................................................................................75 Timer Unit Clock and Period ...............................................................................................................75 Status of the Timer Unit.......................................................................................................................76 TimeSlotPeriod....................................................................................................................................76 9.3 9.3.1 9.3.2 9.3.3 9.3.4 Usage of the Timer Unit ......................................................................................................................78 Time-Out- and Watch-Dog-Counter ....................................................................................................78 Stop Watch ..........................................................................................................................................78 Programmable One-Shot Timer ..........................................................................................................78 Periodical Trigger ................................................................................................................................78 9.4 Register Overview Timer Unit .............................................................................................................79 10 POWER REDUCTION MODES ..........................................................................................................80 10.1 Hard Power Down ...............................................................................................................................80 10.2 Soft Power Down.................................................................................................................................80 10.3 Stand By Mode....................................................................................................................................81 10.4 Receiver Power Down.........................................................................................................................81 11 START UP PHASE .............................................................................................................................82 3 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC SL RC400 11.1 Hard Power Down Phase ....................................................................................................................82 11.2 Reset Phase........................................................................................................................................82 11.3 Initialising Phase .................................................................................................................................82 11.4 Initialising the Parallel Interface-Type .................................................................................................83 12 OSCILLATOR CIRCUITRY ................................................................................................................84 13 TRANSMITTER PINS TX1 AND TX2 .................................................................................................85 13.1 Configuration of TX1 and TX2.............................................................................................................85 13.2 Operating Distance versus Power Consumption ................................................................................85 13.2.1 Antenna Driver Output Source Resistance .........................................................................................86 13.3 Changing the Modulation Index ..........................................................................................................88 13.4 Pulse Width .........................................................................................................................................89 14 RECEIVER CIRCUITRY .....................................................................................................................90 14.1 General................................................................................................................................................90 14.2 Block Diagram .....................................................................................................................................90 14.3 14.3.1 14.3.2 14.3.3 14.3.4 Putting the Receiver into Operation ....................................................................................................91 Automatic Clock-Q Calibration ............................................................................................................91 Amplifier...............................................................................................................................................92 Correlation Circuitry.............................................................................................................................93 Evaluation and Digitizer Circuitry ........................................................................................................93 15 SERIAL SIGNAL SWITCH .................................................................................................................94 15.1 General................................................................................................................................................94 15.2 Block Diagram .....................................................................................................................................94 15.3 Registers Relevant for the Serial Signal Switch..................................................................................95 16 SL RC400 COMMAND SET ...............................................................................................................96 16.1 General Description.............................................................................................................................96 16.2 General Behaviour ..............................................................................................................................96 16.3 16.3.1 16.3.2 16.3.3 SL RC400 Commands Overview ........................................................................................................97 Basic States ........................................................................................................................................98 StartUp Command 3Fhex......................................................................................................................98 Idle Command 00hex ............................................................................................................................98 16.4 16.4.1 16.4.2 16.4.3 16.4.4 16.4.5 Commands for Label Communication.................................................................................................99 Transmit Command 1Ahex....................................................................................................................99 Receive Command 16hex ...................................................................................................................101 Transceive Command 1Ehex ..............................................................................................................103 States of the Label Communication ..................................................................................................103 State Diagram for the Label Communication ....................................................................................104 16.5 Commands to Access the EPROM..................................................................................................105 16.5.1 WriteE2 Command 01hex ...................................................................................................................105 4 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC SL RC400 16.5.2 ReadE2 Command 03hex ...................................................................................................................107 16.6 Diverse Commands...........................................................................................................................108 16.6.1 LoadConfig Command 07hex..............................................................................................................108 16.6.2 CalcCRC Command 12hex .................................................................................................................108 16.7 Error Handling during Command Execution......................................................................................109 17 TYPICAL APPLICATION..................................................................................................................110 17.1 Circuit Diagram..................................................................................................................................110 17.2 17.2.1 17.2.2 17.2.3 17.2.4 Circuit Description .............................................................................................................................111 EMC Low Pass Filter.........................................................................................................................111 Antenna matching .............................................................................................................................111 Receiving Circuit ...............................................................................................................................112 Antenna Coil......................................................................................................................................112 18 TEST SIGNALS ................................................................................................................................113 18.1 General..............................................................................................................................................113 18.2 Measurements Using the Serial Signal Switch .................................................................................113 18.3 Analog Test-Signals ..........................................................................................................................114 18.4 Digital Test-Signals ...........................................................................................................................115 18.5 Examples of Analog- and Digital Test Signals ..................................................................................116 19 ELECTRICAL CHARACTERISTICS ................................................................................................117 19.1 Absolute Maximum Ratings...............................................................................................................117 19.2 Operating Condition Range...............................................................................................................117 19.3 Current Consumption ........................................................................................................................117 19.4 19.4.1 19.4.2 19.4.3 Pin Characteristics ............................................................................................................................118 Input Pin Characteristics ...................................................................................................................118 Digital Output Pin Characteristics .....................................................................................................119 Antenna Driver Output Pin Characteristics .......................................................................................119 19.5 19.5.1 19.5.2 19.5.3 AC Electrical Characteristics .............................................................................................................120 AC Symbols.......................................................................................................................................120 AC Operating Specification ...............................................................................................................121 Clock Frequency ...............................................................................................................................124 20 E2PROM CHARACTERISTICS ........................................................................................................125 21 PACKAGE OUTLINES .....................................................................................................................126 21.1 SO32 .................................................................................................................................................126 22 TERMS AND ABBREVIATIONS ......................................................................................................127 23 DEFINITIONS....................................................................................................................................128 24 LIFE SUPPORT APPLICATIONS ....................................................................................................128 25 REVISION HISTORY ........................................................................................................................129 5 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC 1 1.1 SL RC400 GENERAL INFORMATION Scope This document describes the functionality of the SL RC400. It includes the functional and electrical specifications and gives details on how to design-in this device from system and hardware viewpoint. 1.2 General Description The SL RC400 is member of a new family of highly integrated reader ICs for contactless communication at 13.56 MHz. This new reader IC family utilises an outstanding modulation and demodulation concept completely integrated for all kinds of passive contactless communication methods and protocols at 13.56 MHz. The SL RC400 supports all layers of I*CODE1 and ISO 15693. The internal transmitter part is able to drive an antenna designed for proximity operating distance (up to 100 mm) directly without additional active circuitry. The receiver part provides a robust and efficient implementation of a demodulation and decoding circuitry for signals from I*CODE1 and ISO 15693 compatible transponders. The digital part handles I*CODE1 and ISO 15693 framing and error detection (CRC). A comfortable parallel interface which can be directly connected to any 8-bit -Processor gives high flexibility for the reader/terminal design. 6 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC 1.3 SL RC400 Features * Highly integrated analog circuitry to demodulate and decode label response * Buffered output drivers to connect an antenna with minimum number of external components * Proximity operating distance (up to 100 mm) * Supports I*CODE1 and ISO 15693 * Parallel -Processor interface with internal address latch and IRQ line * Flexible interrupt handling * Automatic detection of parallel C interface type * Comfortable 64 byte send and receive FIFO-buffer * Hard reset with low power function * Power down mode per software * Programmable timer * Unique serial number * User programmable start-up configuration * Bit- and byte-oriented framing * Independent power supply pins for digital, analog and transmitter part * Internal oscillator buffer to connect 13.56 MHz quartz, optimised for low phase jitter * Clock frequency filtering * 3.3 V operation for transmitter (antenna driver) in short range applications 1.4 Ordering Information Type Number SL RC400 01T Package Name Description SO32 Small Outline Package; 32 leads Table 1-1: SL RC400 Ordering Information 7 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC 2 SL RC400 BLOCK DIAGRAM N_WR, N_RD, N_CS ALE A0, A1, A2 D0 to D7 FIFO Control DVDD Voltage Monitor & Power On Detect Parallel Interface Control (incl. Automatic Interface Detection & Synchronisation) DVSS State Machine 64 Byte FIFO Command Register Reset Control Programable Timer Power Down Control RSTPD Control Register Bank Interrupt Control IRQ CRC16/CRC8 Generation & Check EEPROM 8 x 16 Byte EEPROM Access Control Parallel/Seriell Converter Bit Counter Parity Generation & Check Frame Generation & Check Bit Decoding Bit Coding Serial Data Switch SIGOUT Level Shifters Amplitude Rating Correlation and Bit Decoding Clock Generation, Filtering and Distribution Oscillator Q-Clock Generation Power On Detect Reference Voltage Analog Test MUX I-Channel Amplifier Q-Channel Amplifier I-Channel Demodulator Q-Channel Demodulator OSCIN OSCOUT V+ GND V+ AUX AVSS Transmitter Control GND VMID AVDD RX TVSS 8 TX1 TX2 TVDD Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC 3 3.1 SL RC400 PINNING INFORMATION Pin Configuration Pins denoted by bold letters are supplied by AVDD and AVSS. Pins drawn with bold lines are supplied by TVSS and TVDD. All other pins are supplied by DVDD and DVSS. OSCIN 1 32 OSCOUT IRQ 2 31 RSTPD RFU 3 30 VMID SIGOUT 4 29 RX TX1 5 28 AVSS TVDD 6 27 AUX TX2 7 26 AVDD TVSS 8 25 DVDD NCS 9 24 A2 NWR 10 23 A1 NRD 11 22 A0 DVSS 12 21 ALE D0 13 20 D7 D1 14 19 D6 D2 15 18 D5 D3 16 17 D4 SL RC400 SO32 Figure 3-1: SL RC400 Pin Configuration for SO32 package 9 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC 3.2 SL RC400 Pin Description Pin Types: I...Input; PIN 1 SYMBOL O...Output; PWR...Power TYPE DESCRIPTION Crystal Oscillator Input: input to the inverting amplifier of the oscillator. This pin is also the input for an externally generated clock (fosc = 13.56 MHz). OSCIN I 2 IRQ O Interrupt Request: output to signal an interrupt event 3 RFU I This Pin should be connected to Ground 4 SIGOUT O I*CODE Interface Output: delivers a serial data stream according to I*CODE1 and ISO 15693 5 TX1 O Transmitter 1: delivers the modulated 13.56 MHz carrier frequenzy 6 TVDD 7 TX2 8 TVSS PWR O PWR Transmitter Power Supply: supplies the output stage of TX1 and TX2 Transmitter 2: delivers the modulated 13.56 MHz carrier frequenzy Transmitter Ground: supplies the output stage of TX1 and TX2 NCS I Not Chip Select: selects and activates the -Processor interface of the SL RC400 NWR I Not Write: strobe to write data (applied on D0 to D7) into the SL RC400 register R/NW I Read Not Write: selects if a read or write cycle shall be performed. nWrite I Not Write: selects if a read or write cycle shall be performed NRD I Not Read: strobe to read data from the SL RC400 register (applied on D0 to D7) NDS I Not Data Strobe: strobe for the read and the write cycle nDStrb I Not Data Strobe: strobe for the read and the write cycle 12 DVSS PWR 13 ... 201 D0 to D7 I/O 8 Bit Bi-directional Data Bus AD0 to AD7 I/O 8 Bit Bi-directional Address and Data Bus 9 10 1 111 Digital Ground ALE I Address Latch Enable: strobe signal to latch AD0 to AD5 into the internal address latch when HIGH. AS I Address Strobe: strobe signal to latch AD0 to AD5 into the internal address latch when HIGH. nAStrb I Not Address Strobe: strobe signal to latch AD0 to AD5 into the internal address latch when LOW. A0 I Address Line 1: Bit 0 of register address nWait O Not Wait: signals with LOW that an access-cycle may started and with HIGH that it may be finished. 23 A1 I Address Line 1: Bit 1 of register address 24 A2 I Address Line 2: Bit 2 of register address 25 DVDD PWR Digital Power Supply 26 AVDD PWR Analog Power Supply 211 221 1 These pins offer different functionality according to the selected -Processor interface type. For detailed information refer to chapter 4. 10 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC SL RC400 PIN Description (continued) PIN SYMBOL TYPE O DESCRIPTION Auxiliary Output: This pin delivers analog test signals. The signal delivered on this output may be selected by means of the TestAnaOutSel Register. 27 AUX 28 AVSS 29 RX 30 VMID 31 RSTPD I Reset and Power Down: When HIGH, internal current sinks are switched off, the oscillator is inhibited, and the input pads are disconnected from the outside world. With a negative edge on this pin the internal reset phase starts. 32 OSCOUT O Crystal Oscillator Output: Output of the inverting amplifier of the oscillator. PWR I PWR Analog Ground Receiver Input: Input pin for the labels response, which is the load modulated 13.56 MHz carrier frequenzy, that is coupled out from the antenna circuit. Internal Reference Voltage: This pin delivers the internal reference voltage. Note: It has to be supported by means of a 100 nF block capacitor. Table 3-1: SL RC400 Pin Description 11 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC 4 SL RC400 PARALLEL INTERFACE 4.1 Overview of Supported -Processor Interfaces The SL RC400 supports direct interfacing of various -Processor. Alternatively the Enhanced Parallel Port (EPP) of personal computers can be connected directly. The following table shows the parallel interface signals supported by the SL RC400: Bus Control Signals Separated Read and Write Strobes Common Read and Write Strobe Bus Separated Address and Data Bus Multiplexed Address and Data Bus control NRD, NWR, NCS NRD, NWR, NCS, ALE address A0, A1, A2 AD0, AD1, AD2, (AD3, AD4, AD5) data D0 ... D7 AD0 ... AD7 control R/NW, NDS, NCS R/NW, NDS, NCS, AS address A0, A1, A2 AD0, AD1, AD2, (AD3, AD4, AD5) data D0 ... D7 AD0 ... AD7 nWrite, nDStrb, NCS, nAStrb, nWait control Common Read and Write Strobe with Handshake - address AD0, AD1, AD2, (AD3, AD4, AD5) (EPP) AD0 ... AD7 data Table 4-1: Supported -Processor Interface Signals 4.2 Automatic -Processor Interface Type Detection After each Power-On or Hard Reset, the SL RC400 also resets its parallel -Processor interface mode and checks the current -Processor interface type. The SL RC400 identifies the -Processor interface by means of the logic levels on the control pins after the Reset Phase. This is done by a combination of fixed pin connections (see below) and a dedicated initialisation routine (see 11.4). 12 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC 4.3 SL RC400 Connection to Different -Processor Types The connection to different -Processor types is shown in the following table: Parallel Interface Type Separated Read/Write Strobe Common Read/Write Strobe SL RC400 Dedicated Address Bus Multiplexed Address Bus Dedicated Address Bus Multiplexed Address Bus Multiplexed Address Bus with Handshake ALE HIGH ALE HIGH AS nAStrb A2 A2 LOW A2 LOW HIGH A1 A1 HIGH A1 HIGH HIGH A0 A0 HIGH A0 LOW nWait NRD NRD NRD NDS NDS nDStrb NWR NWR NWR R/NW R/NW nWrite NCS NCS NCS NCS NCS LOW D7 ... D0 D7 ... D0 AD7 ... AD0 D7 ... D0 AD7 ... AD0 AD7 ... AD0 Table 4-2: Connection Scheme for Detecting the Parallel Interface Type 4.3.1 SEPARATED READ/WRITE STROBE: INTEL TYPE COMPATIBLE SL RC400 Address Bus (A3...An) Address Decoder SL RC400 NCS Non Multiplexed Address Address Decoder LOW Address Bus (A0...A2) A0...A2 HIGH HIGH Data Bus (D0...D7) HIGH Read Strobe (NRD) Write Strobe (NWR) D0...D7 Multiplexed Address/Data (AD0...AD7) Address Latch Enable (ALE) ALE Read Strobe (NRD) NRD Write Strobe (NWR) NWR NCS A2 A1 A0 D0...D7 ALE NRD NWR Figure 4-1: Connection to -Processors with Separated Read/Write Strobes For timing specification refer to chapter 19.5.2.1. 13 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC 4.3.2 SL RC400 COMMON READ/WRITE STROBE: MOTOROLA TYPE COMPATIBLE SL RC400 Address Bus (A3...An) Address Decoder SL RC400 NCS Non Multiplexed Address Address Decoder LOW Address Bus (A0...A2) A0...A2 Data Bus (D0...D7) D0...D7 HIGH Data Strobe (NDS) Read/Write (R/NW) HIGH LOW Multiplexed Address/Data (AD0...AD7) Address Strobe (AS) ALE Data Strobe (NDS) NRD Read/Write (R/NW) NWR NCS A2 A1 A0 D0...D7 ALE NRD NWR Figure 4-2: Connection to -Processors with Common Read/Write Strobes For timing specification refer to chapter 19.5.2.2. 14 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC 4.3.3 SL RC400 COMMON READ/WRITE STROBE AND HAND-SHAKE MECHANISM: EPP SL RC400 LOW NCS HIGH A2 A1 A0 HIGH nWait D0...D7 Multiplexed Address/Data (AD1...AD8) Address Strobe (nAStrb) ALE Data Strobe (nDStrb) NRD Read/Write (nWrite) NWR Figure 4-3: Connection to -Processors with Common Read/Write Strobes and Hand-Shake For timing specification refer to chapter 19.5.2.3. Remarks for EPP: Although in the standard for the EPP no chip select signal is defined, the N_CS of the SL RC400 allows inhibiting the nDStrb signal. If not used, it shall be connected to DVSS. After each Power-On or Hard Reset the nWait signal (delivered at pin A0) is high impedance. nWait will be defined at the first negative edge applied to nAStrb after the Reset Phase. The SL RC400 does not support Read Address Cycle. 15 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC 5 SL RC400 SL RC400 REGISTER SET SL RC400 Registers Overview Addresshex Register Name Function 0 Page selects the register page 1 Command starts (and stops) the command execution 2 FIFOData in- and output of 64 byte FIFO buffer 3 PrimaryStatus status flags of the receiver and transmitter and of the FIFO buffer 4 FIFOLength number of bytes buffered in the FIFO 5 SecondaryStatus diverse status flags 6 InterruptEn control bits to enable and disable passing of interrupt requests 7 InterruptRq interrupt request flags 8 Page selects the register page 9 Control diverse control flags e.g.: timer, power saving A ErrorFlag error flags showing the error status of the last command executed B Collpos bit position of the first bit collision detected on the RF-interface C TimerValue actual value of the timer D CRCResultLSB LSB of the CRC-Coprocessor register E CRCResultMSB MSB of the CRC-Coprocessor register F PreSet0F these values shall not be changed 10 Page selects the register page 11 TxControl controls the logical behaviour of the antenna driver pins TX1 and TX2 12 CwConductance selects the conductance of the antenna driver pins TX1 and TX2 13 ModConductance selects the conductance of the antenna driver pins TX1 and TX2 during modulation 14 CoderControl Selects the bit coding mode and the framing during transmission 15 ModWidth selects the width of the modulation pulse 16 ModWidthSOF selects the width of the modulation pulse for SOF (I*CODE Fast-Mode) 17 PreSet17 these values shall not be changed 18 Page selects the register page 19 RxControl1 controls receiver behaviour 1A DecoderControl controls decoder behaviour 1B BitPhase selects the bit-phase between transmitter and receiver clock 1C RxThreshold selects thresholds for the bit decoder 1D PreSet1D these values shall not be changed 1E RxControl2 controls decoder behaviour and defines the input source for the receiver 1F ClockQControl controls clock generation for the 90 phase shifted Q-channel clock Page 3: Receiver and Decoder Control Page 2: Transmitter and Coder Control Page 1: Control and Status Page Page 0: Command and Status 5.1 16 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC SL RC400 SL RC400 Register Set (continued) Page 7: Test Control Page 6: RFU Page 5: FIFO, Timer and IRQ-Pin Configuration Page 4: RF-Timing and Channel Redundancy Page Addresshex Register Name Function 20 Page selects the register page 21 RxWait selects the time interval after transmission, before receiver starts 22 ChannelRedundancy selects the kind and mode of checking the data integrity on the RFchannel 23 CRCPresetLSB LSB of the pre-set value for the CRC register 24 CRCPresetMSB MSB of the pre-set value for the CRC register 25 TimeSlotPeriod selects the time between automatically mitted Frames see chapter 9.2.5 26 SIGOUTSelect selects internal signal applied to pin SIGOUT includes the MSB of value TimeSlotPeriod see register 0x25 27 PreSet27 these values shall not be changed 28 Page Selects the register page 29 FIFOLevel defines level for FIFO over- and underflow warning 2A TimerClock selects the divider for the timer clock 2B TimerControl selects start and stop conditions for the timer 2C TimerReload defines the pre-set value for the timer 2D IrqPinConfig configures the output stage of pin IRq 2E PreSet2E these values shall not be changed 2F PreSet2F these values shall not be changed 30 Page selects the register page 31 RFU reserved for future use 32 RFU reserved for future use 33 RFU reserved for future use 34 RFU reserved for future use 35 RFU reserved for future use 36 RFU reserved for future use 37 RFU reserved for future use 38 Page selects the register page 39 RFU reserved for future use 3A TestAnaSelect selects analog test mode 3B PreSet3B these values shall not be changed 3C PreSet3C these values shall not be changed 3D TestDigiSelect selects digital test mode 3E RFU reserved for future use 3F RFU reserved for future use Table 5-1: SL RC400 Register Overview 17 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC 5.1.1 SL RC400 REGISTER BIT BEHAVIOUR Bits and flags for different registers behave differently, depending on their functions. In principle bits with same behaviour are grouped in common registers. Abbreviation Behaviour Description read and write These bits can be written and read by the -Processor. Since they are used only for control means, there content is not influenced by internal state machines, e.g. the TimerReload-Register may be written and read by the Processor. It will also be read by internal state machines, but never changed by them. dy dynamic These bits can be written and read by the -Processor. Nevertheless, they may also be written automatically by internal state machines, e.g. the CommandRegister changes its value automatically after the execution of the actual command. r read only These registers hold flags, which value is determined by internal states only, e.g. the ErrorFlag-Register can not be written from external but shows internal states. write only These registers are used for control means only. They may be written by the Processor but can not be read. Reading these registers returns an undefined value, e.g. the TestAnaSelect-Register is used to determine the signal on pin AUX, but it is not possible to read its content. r/w w Table 5-2: Behaviour of Register Bits and its Designation 18 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC 5.2 SL RC400 Register Description 5.2.1 PAGE 0: COMMAND AND STATUS 5.2.1.1 Page Register Selects the register page. Name: Page Access Rights Address: 0x00, 0x08, 0x10, 0x18, 0x20, 0x28, 0x30, 0x38 7 6 5 4 3 UsePage Select 0 0 0 0 r/w r/w r/w r/w r/w Reset value: 10000000, 0x80 2 1 0 PageSelect r/w r/w r/w Description of the bits Bit Symbol Function 7 UsePageSelect If set to 1, the value of PageSelect is used as register address A5, A4, and A3. The LSBbits of the register address are defined by the address pins or the internal address latch, respectively. If set to 0, the whole content of the internal address latch defines the register address. The address pins are used as described in Table 4-2. 6-3 0000 2-0 PageSelect Reserved for future use. The value of PageSelect is used only if UsePageSelect is set to 1. In this case, it specifies the register page (which is A5, A4, and A3 of the register address). 19 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC 5.2.1.2 SL RC400 Command Register Starts and stops the command execution. Name: Command Address: 0x01 7 6 IFDetect Busy 0 r r Access Rights 5 4 Reset value:X0000000, 0xX0 3 2 1 0 dy dy dy Command dy dy dy Description of the bits Bit Symbol 7 IFDetectBusy 6 0 5-0 Command Function Shows the status of Interface Detection Logic: Set to 0 means `Interface Detection finished successfully', Set to 1 signs `Interface Detection Ongoing'. Reserved for future use. Activates a command according the Command Code. Reading this register shows, which command is actually executed. See chapter 16. SL RC400 Command Set. 20 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC 5.2.1.3 SL RC400 FIFOData Register In- and output of the 64 byte FIFO buffer Name: FIFOData 7 Address: 0x02 6 5 Reset value: XXXXXXXX, 0xXX 4 3 2 1 0 dy dy dy dy FIFOData Access Rights dy dy dy dy Description of the bits Bit Symbol 7-0 FIFOData Function Data Input and Output Port for the internal 64 byte FIFO buffer. The FIFO buffer acts as parallel in/parallel out converter for all data stream in- and outputs. 21 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC 5.2.1.4 SL RC400 PrimaryStatus Register Status flags of the receiver, transmitter and the FIFO buffer. Name: PrimaryStatus 7 Address: 0x03 6 0 Access Rights r 5 Reset value: 00000001, 0x01 4 ModemState r r r 3 2 1 0 IRq Err HiAlert LoAlert r r r r Description of the bits Bit Symbol 7 0 6-4 ModemState Function Reserved for future use. ModemState shows the state of the transmitter and receiver state machines. State Name of State Description 000 Idle Neither the transmitter nor the receiver is in operation, since none of them is started or since none of them has got input data. 001 TxSOF Transmitting the `Start Of Frame' Pattern. 010 TxData Transmitting data from the FIFO buffer (or redundancy check bits). 011 TxEOF Transmitting the `End Of Frame' Pattern. 100 GoToRx1 Mean-State passed, when receiver starts. GoToRx2 Mean-State passed, when receiver finishes. 101 PrepareRx Waiting until the time period selected in the RxWait Register has expired. 110 AwaitingRx Receiver activated; Awaiting an input signal at pin Rx. 111 Receiving Receiving data. 3 IRq This bit shows, if any interrupt source requests attention (with respect to the setting of the interrupt enable flags in the InterruptEn Register). 2 Err This bit is set to 1, if any error flag in the ErrorFlag Register is set. 1 HiAlert Is set to 1, when the number of bytes stored in the FIFO buffer fulfil the following equation: HiAlert = (64 - FIFOLength) WaterLevel Example: 0 LoAlert FIFOLength=60, WaterLevel=4 HiAlert =1 FIFOLength=59, WaterLevel=4 HiAlert =0 Is set to 1, when the number of bytes stored in the FIFO buffer fulfil the following equation: LoAlert = FIFOLength WaterLevel Example: FIFOLength=4, WaterLevel=4 LoAlert =1 FIFOLength=5, WaterLevel=4 LoAlert =0 22 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC 5.2.1.5 SL RC400 FIFOLength Register Number of bytes buffered in the FIFO. Name: FIFOLength 7 Address: 0x04 6 5 Reset value: 00000000, 0x00 4 0 Access Rights r 3 2 1 0 r r r FIFOLength r r r r Description of the bits Bit Symbol 7 0 6-0 FIFOLength Function Reserved for future use. Indicates the number of bytes stored in the FIFO buffer. Writing to the FIFOData Register increments, reading decrements FIFOLength. 23 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC 5.2.1.6 SL RC400 SecondaryStatus Register Diverse Status flags. Name: SecondaryStatus Access Rights Address: 0x05 Reset value: 01100000, 0x60 7 6 5 4 3 TRunning E2Ready CRCReady 0 0 r r r r r 2 1 0 RxLastBits r r r Description of the bits Bit Symbol Function 7 TRunning If set to 1, the SL RC400's timer unit is running, e.g. the counter will decrement the Timer Value Register with the next timer clock. 6 E2Ready If set to 1, the SL RC 400 has finished programming the E2PROM. 5 CRCReady 4-3 00 2-0 RxLastBits If set to 1, the SL RC400 has finished calculating the CRC. Reserved for future use. Show the number of valid bits in the last received byte. If zero, the whole byte is valid. 24 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC 5.2.1.7 SL RC400 InterrupEn Register Control bits to enable and disable passing of interrupt requests. Name: InterruptEn Access Rights Address: 0x06 Reset value: 00000000, 0x00 7 6 5 4 3 2 1 0 SetIEn 0 TimerIEn TxIEn RxIEn IdleIEn HiAlertIEn LoAlertIEn w r/w r/w r/w r/w r/w r/w r/w Description of the bits Bit Symbol Function 7 SetIEn 6 0 5 TimerIEn 4 TxIEn Allows the transmitter interrupt request (indicated by bit TxIRq) to be propagated to pin IRQ. This bit can not be set or cleared directly but only by means of bit SetIEn. 3 RxIEn Allows the receiver interrupt request (indicated by bit RxIRq) to be propagated to pin IRQ. This bit can not be set or cleared directly but only by means of bit SetIEn. 2 IdleIEn Allows the idle interrupt request (indicated by bit IdleIRq) to be propagated to pin IRQ. This bit can not be set or cleared directly but only by means of bit SetIEn. 1 HiAlertIEn Allows the high alert interrupt request (indicated by bit HiAlertIRq) to be propagated to pin IRQ. This bit can not be set or cleared directly but only by means of bit SetIEn. 0 LoAlertIEn Allows the low alert interrupt request (indicated by bit LoAlertIRq) to be propagated to pin IRQ. This bit can not be set or cleared directly but only by means of bit SetIEn. Set to 1 SetIEn defines that the marked bits in the InterruptEn Register are set, Set to 0 clears the marked bits. Reserved for future use. Allows the timer interrupt request (indicated by bit TimerIRq) to be propagated to pin IRQ. This bit can not be set or cleared directly but only by means of bit SetIEn. 25 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC 5.2.1.8 SL RC400 InterruptRq Register Interrupt request flags. Name: InterruptRq Access Rights Address: 0x07 Reset value: 00000000, 0x00 7 6 5 4 3 2 1 0 SetIRq 0 TimerIRq TxIRq RxIRq IdleIRq HiAlertIRq LoAlertIRq w r/w dy dy dy dy dy dy Description of the bits Bit Symbol 7 SetIRq 6 0 5 TimerIRq 4 TxIRq Function Set to 1 SetIRq defines that the marked bits in the InterruptRq Register are set. Set to 0 defines, that the marked bits in the InterruptRq Register are cleared. Reserved for future use. Set to 1, when the timer decrements the TimerValue Register to zero. Set to 1, when one of the following events occurs: Transceive Command: All data transmitted. CalcCRC Command: All data is processed. WriteE2 Command: All data is programmed. 3 RxIRq This bit is set to 1, when the receiver terminates. 2 IdleIRq This bit is set to 1, when a command terminates by itself e.g. when the Command Register changes its value from any command to the Idle Command. If an unknown command is started bit IdleIRq is set. Starting the Idle Command by the -Processor does not set bit IdleIRq. 1 HiAlertIRq This bit is set to 1, when bit HiAlert is set. In opposite to HiAlert, HiAlertIRq stores this event and can only be reset by means of bit SetIRq. 0 LoAlertIRq This bit is set to 1, when bit LoAlert is set. In opposite to LoAlert, LoAlertIRq stores this event and can only be reset by means of bit SetIRq. 26 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC 5.2.2 SL RC400 PAGE 1: CONTROL AND STATUS 5.2.2.1 Page Register Selects the register page. See 5.2.1.1 Page register. 5.2.2.2 Control Register Diverse control flags, e.g. : timer, power saving Name: Control Access Rights Address: 0x09 Reset value: 00000000, 0x00 7 6 5 4 3 2 1 0 0 0 StandBy PowerDown 0 TStopNow TStartNow FlushFIFO r/w r/w dy dy dy w w w Description of the bits Bit Symbol Function 7-6 00 5 StandBy Setting this bit to 1 enters the Soft PowerDown Mode. This means, internal current consuming blocks switch off, the oscillator keeps running. 4 PowerDown Setting this bit to 1 enters the Soft PowerDown Mode. This means, internal current consuming blocks switch off including the oscillator. 3 0 2 TStopNow Setting this bit to 1 starts the timer immediately. Reading this bit will always return 0. 1 TStartNow Setting this bit to 1 stops the timer immediately. Reading this bit will always return 0. 0 FlushFIFO Setting this bit to 1clears the internal FIFO-buffer's read- and write-pointer (FIFOLength becomes 0) and the flag FIFOOvfl immediately. Reading this bit will always return 0. Reserved for future use Reserved for future use 27 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC 5.2.2.3 SL RC400 ErrorFlag Register Error flags showing the error status of the last executed command. Name: ErrorFlag Access Rights Address: 0x0A Reset value: 00000000, 0x00 7 6 5 4 3 2 1 0 0 0 AccessErr FIFOOvfl CRCErr FramingErr 0 CollErr r r r r r r r r Description of the bits Bit Symbol Function 7-6 0 5 AccessErr This bit is set to 1, if the access rights to the EPROM are violated. This bit is set to 0 starting an EPROM related command. 4 FIFOOvfl This bit is set to 1, if the -Processor or a SL RC400's internal state machine (e.g. receiver) tries to write data into the FIFO buffer although the FIFO buffer is already full. 3 CRCErr This bit is set to 1, if RxCRCEn is set and the CRC fails. It is cleared to 0 automatically at receiver start phase during the state PrepareRx. 2 FramingErr 1 0 0 CollErr Reserved for future use. This bit is set to 1, if the SOF is incorrect. It is cleared automatically at receiver start (that is during the state PrepareRx). RFU This bit is set to 1, if a bit-collision is detected. It is cleared automatically at receiver start (that is during the state PrepareRx). 28 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC 5.2.2.4 SL RC400 CollPos Register Bit position of the first bit collision detected on the RF- interface. Name: CollPos Address: 0x0B 7 6 5 Reset value: 00000000, 0x00 4 3 2 1 0 r r r r CollPos Access Rights r r r r Description of the bits Bit Symbol 7-0 CollPos Function This register shows the bit position of the first detected collision in a received frame. Example: 0x00 indicates a bit collision in the start bit 0x01 indicates a bit collision in the 1st bit 0x08 indicates a bit collision in the 8th bit 29 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC 5.2.2.5 SL RC400 TimerValue Register Actual value of the timer Name: TimerValue 7 Address:0x0C 6 5 Reset value: XXXXXXXX, 0xXX 4 3 2 1 0 r r r TimerValue Access Rights r r r r r Description of the bits Bit Symbol 7-0 TimerValue Function This register shows the actual value of the timer counter. 30 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC 5.2.2.6 SL RC400 CRCResultLSB Register LSB of the CRC-Coprocessor register. Name: CRCResultLSB 7 Address: 0x0D 6 5 Reset value: XXXXXXXX, 0xXX 4 3 2 1 0 r r r CRCResultLSB Access Rights r r r r r Description of the bits Bit Symbol 7-0 CRCResultLSB Function This register shows the actual value of the least significant byte of the CRC register. It is valid only if bit CRCReady is set to 1. 31 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC 5.2.2.7 SL RC400 CRCResultMSB Register MSB of the CRC-Coprocessor register. Name: CRCResultMSB 7 Address: 0x0E 6 5 Reset value: XXXXXXXX, 0xXX 4 3 2 1 0 r r r CRCResultMSB Access Rights r r r r r Description of the bits Bit Symbol 7-0 CRCResultMSB Function This register shows the actual value of the most significant byte of the CRC register. It is valid only if bit CRCReady is set to 1. For 8-bit CRC calculation the registers value is undefined. 5.2.2.8 BitFraming Register Adjustments for bit oriented frames. Name: BitFraming 7 Address: 0x0F 6 0 Access Rights r/w 5 Reset value: 00000000, 0x00 4 RxAlign dy dy 3 2 0 dy r/w 1 0 TxLastBits dy dy dy Description of the bits Bit Symbol 7 0 6-4 RxAlign Function Reserved for future use Used for reception of bit oriented frames: RxAlign defines the bit position for the first bit received to be stored in the FIFO. Further received bits are stored in the following bit positions. After reception, RxAlign is cleared automatically. Example: RxAlign = 0: the LSB of the received bit is stored at bit 0, second received bit is stored at bit position 1 RxAlign = 1: the LSB of the received bit is stored at bit 1, 32 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC SL RC400 second received bit is stored at bit position 2 RxAlign = 7: 3 0 2-0 TxLastBits the LSB of the received bit is stored at bit 7, second received bit is stored in the following byte at bit position 0 reserved for future use Used for transmission of bit oriented frames: TxLastBits defines the number of bits of the last byte that shall be transmitted. A 000 indicates that all bits of the last byte shall be transmitted. After transmission, TxLastBits is cleared automatically. 33 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC 5.2.3 SL RC400 PAGE 2: TRANSMITTER AND CONTROL 5.2.3.1 Page Register Selects the register page. See 5.2.1.1 Page register. 5.2.3.2 TxControl Register Controls the logical behaviour of the antenna pin TX1 and TX2 Name: TxControl 7 0 Access Rights r/w Address: 0x11 6 5 ModulatorSource r/w r/w Reset value: 01001000, 0x48 4 3 2 1 0 Force100 ASK TX2Inv TX2Cw TX2RFEn TX1RFEn r/w r/w r/w r/w r/w Description of the bits Bit Symbol 7 0 6-5 Modulator Source Function This value shall not be changed Selects the source for the modulator input: 00: LOW 01: HIGH 10: Internal Coder 11: RFU 4 Force100ASK Set to 1, forces a 100% ASK Modulation independent of the setting in the ModConductance Register. 3 TX2Inv Set to 1, the output signal on pin TX2 will deliver an inverted 13.56 MHz carrier frequenzy. 2 TX2Cw Set to 1, the output signal on pin TX2 will deliver continuously the un-modulated 13.56 MHz carrier frequenzy. Setting TX2Cw to 0 enables modulation of the 13.56 MHz carrier frequenzy. 1 TX2RFEn Set to 1, the output signal on pin TX2 will deliver the 13.56 MHz carrier frequency modulated by the transmission data. If TX2RFEn is 0, TX2 drives a constant output level. See chapter 13. 0 TX1RFEn Set to 1, the output signal on pin TX1 will deliver the 13.56 MHz carrier frequency modulated by the transmission data. If TX1RFEn is 0, TX1 drives a constant output level. See chapter 13. 34 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC 5.2.3.3 SL RC400 CwConductance Register Selects the conductance of the antenna driver pins TX1 and TX2. Name: CwConductance Access Rights Address: 0x12 7 6 0 0 r/w r/w 5 Reset value: 00111111, 0x3F 4 3 2 1 0 r/w r/w r/w GsCfgCW r/w r/w r/w Description of the bits Bit Symbol 7-6 00 5-0 GsCfgCW Function These values shall not be changed The value of this register defines the conductance of the output driver. This may be used to regulate the output power and subsequently current consumption and operating distance. For detailed information about GsCfgCW see 13.2.1 5.2.3.4 ModConductance Register Name: ModConductance Access Rights Address: 0x13 7 6 0 0 r/w r/w 5 Reset value: 00000101, 0x05 4 3 2 1 0 r/w r/w r/w GsCfgMod r/w r/w r/w Description of the bits Bit Symbol 7-6 00 5-0 GsCfgMod Function These values shall not be changed The value of this register defines the conductance of the output driver for the time of modulation. This may be used to regulate the modulation index. For detailed information about GsCfgMod see 13.3 35 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC 5.2.3.5 SL RC400 CoderControl Register Name: CoderControl Access Rights Address:0x14 7 6 SendOne Pulse 0 r/w r/w 5 Reset value: 00101100, 0x2C 4 3 2 CoderRate r/w r/w 1 0 TxCoding r/w r/w r/w r/w Description of the bits Bit Symbol 7 SendOnePulse 6 0 5-3 CoderRate Function Set to 1, forces to generate only one Mudulation (for ISO 15693 only). This is used to switch to the next TimeSlot if the Inventory command is used. This bit is not cleared automatically, it has to be re-set to 0 by the user. These values shall not be changed This register defines the clock rate for Coder Circuit 000: 001: 010: 011: 100: 101: 110: 111: 2-0 TxCoding RFU RFU RFU RFU ~106kHz For ICODE1 standard mode and ISO 15693 (~52.97kHz) For ICODE1 fast mode (~26.48kHz) RFU This register defines the bit coding Mode and Framing during Transmission 000: 001: 010: 011: 100: 101: 110: 111: RFU RFU RFU RFU For ICODE1 standard mode (1 out of 256 coding) For ICODE1 fast mode (RZ coding) For ISO 15693 standard mode (1 out of 256 coding) For ISO 15693 fast mode (1 out of 4 coding) 36 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC 5.2.3.6 SL RC400 ModWidth Register selects the width of the modulation pulse. Name: ModWidth 7 Address: 0x15 6 5 Reset value: 00111111, 0x3F 4 3 2 1 0 r/w r/w r/w r/w ModWidth Access Rights r/w r/w r/w r/w Description of the bits Bit Symbol 7-0 ModWidth Function This register defines the width of the modulation pulse according to Tmod = 2(ModWidth +1) / fc (fc = Oscillator clock 13.56 MHz). Preset for I*CODE1 (Fast and Standard Mode) and ISO 15693 is 0x3F (Modulation width: 9.44s). 5.2.3.7 ModWidthSOF Register Name: ModWidthSOF 7 Address: 0x16 6 5 Reset value: 00111111, 0x3F 4 3 2 1 0 r/w r/w r/w ModWidthSOF Access Rights r/w r/w r/w r/w r/w Description of the bits Bit Symbol 7-0 ModWidthSOF Function This register defines the width of the modulation pulse for SOF Tmod = 2(ModWidth +1) / fc . Register setting: I*CODE1 Standard Mode: 0x3F (Modulation width SOF: 9.44s). I*CODE1 Fast Mode: 0x73 (Modulation width SOF: 18.88s). ISO 15693: 0x3F (Modulation width SOF: 9.44s). 37 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC 5.2.3.8 SL RC400 PreSet17 Register Name: PreSet17 Access Rights Address: 0x17 Reset value: 00000000, 0x00 7 6 5 4 3 2 1 0 0 0 0 0 0 0 0 0 r/w r/w r/w r/w r/w r/w r/w r/w Note: These values shall not be changed ! 5.2.4 PAGE 3: RECEIVER AND DECODER CONTROL 5.2.4.1 Page Register Selects the register page. See 5.2.1.1 Page Register. 5.2.4.2 RxControl1 Register controls receiver behaviour. Name: RxControl1 7 Address: 0x19 6 5 SubCPulses Access Rights r/w r/w r/w Reset value: 10001011, 0x8B 4 3 2 0 1 0 r/w r/w r/w 1 Gain r/w Description of the bits Bit Symbol 7-5 SubCPulses 4-2 010 Function Defines the number of subcarrier pulses per Bit 000: RFU 001: RFU 010: RFU 011: 8 Pulses I*CODE SLI (fast inventory read, 53 kBaud) 100: 16 Pulses I*CODE1, ISO15693 101: RFU 110: RFU 111: RFU These value shall not be changed 38 0 r/w Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC 1-0 Gain SL RC400 This register defines the receivers signal voltage gain factor: 00: 27 dB 01: 31 dB 10: 38 dB 11: 42 dB 5.2.4.3 DecoderControl Register controls decoder behaviour. Name: DecoderControl Access Rights Address: 0x1A 7 6 5 0 Rx Multiple ZeroAfter Coll r/w r/w r/w Reset value: 00000000, 0x00 4 3 RxFraming r/w r/w 2 1 0 RxInvert 0 0 r/w r/w r/w Description of the bits Bit Symbol 7 0 6 RxMultiple 5 ZeroAfterColl 4-3 RxFraming 2 RxInvert 1-0 00 Function These values shall not be changed If set to 0, the receiver is deactivated after receiving the Datastream. If set to 1, it is possible to receive more than one Frame. If set to 1, any bits received after a bit-collision are masked to zero. This eases resolving the anti-collision procedure defined in the standard ISO 15693. Selects the receiving frame type 00 for I*CODE1 01 RFU 10 ISO 15693 11 RFU If set to 0, a modulation at the first half bit results a logic 1 (according I*CODE1) If set to 1, a modulation at the first half bit results a logic 0 (according ISO15693) These values shall not be changed 39 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC 5.2.4.4 SL RC400 BitPhase Register selects the bit-phase between transmitter and receiver clock. Name: BitPhase Address: 0x1B 7 6 5 Reset value: 01010100, 0x54 4 3 2 1 0 r/w r/w r/w r/w BitPhase Access Rights r/w r/w r/w r/w Description of the bits Bit Symbol 7-0 BitPase Function Defines the phase relation between transmitter and receiver clock. Note: The correct value of this register is essential for proper operation. 40 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC 5.2.4.5 SL RC400 RxThreshold Register selects thresholds for the bit decoder. Name: RxThreshold Address: 0x1C 7 6 5 Reset value: 01101000, 0x68 4 3 2 MinLevel Access Rights r/w r/w 1 0 r/w r/w CollLevel r/w r/w r/w r/w Description of the bits Bit Symbol 7-4 MinLevel Function Defines the minimum signal strength at the decoder input that shall be accepted. If the signal strength is below this level, it is not evaluated. 3-0 5.2.4.6 CollLevel Defines the minimum signal strength at the decoder input that has to be reached by the weaker half-bit of the Manchester-coded signal to generate a bit-collision relatively to the amplitude of the stronger half-bit. PreSet1D Register Name: PreSet1D Access Rights Address: 0x1D Reset value: 00000000, 0x00 7 6 5 4 3 2 1 0 0 0 0 0 0 0 0 0 r/w r/w r/w r/w r/w r/w r/w r/w Note: These values shall not be changed ! 41 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC 5.2.4.7 SL RC400 RxControl2 Register controls decoder behaviour and defines the input source for the receiver. Name:RxControl2 Access Rights Address: 0x1E Reset value: 01000001, 0x41 7 6 5 4 3 2 RcvClkSelI RxAutoPD 0 0 0 0 r/w r/w r/w R/w r/w r/w 1 0 DecoderSource r/w r/w Description of the bits Bit Symbol Function 7 RcvClkSelI If set to 1, the I-clock is used for the receiver clock. 0 indicates, the Q-clock is used. I-clock and Q-clock are 90 phase shifted to each other 6 RxAutoPD If set to 1, the receiver circuit is automatically switched on before receiving and switched off afterwards. This may be used to reduce current consumption. If set to 0, the receiver is always activated. 5-2 0000 1-0 DecoderSource These values shall not be changed Selects the source for the decoder input: 00: Low 01: Internal Demodulator 10: RFU 11: RFU 42 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC 5.2.4.8 SL RC400 ClockQControl Register controls clock generation for the 90 phase shifted Q-channel clock. Name: ClockQControl Address: 0x1F 7 6 5 ClkQ180Deg ClkQCalib 0 r r/w r/w Access Rights Reset value: 000XXXXX, 0xXX 4 3 2 1 0 dy dy ClkQDelay dy dy dy Description of the bits Bit Symbol Function 7 ClkQ180Deg If the Q-clock is phase shifted more than 180 compared to the I-clock, this bit is set to 1, otherwise it is 0. 6 ClkQCalib If this bit is 0, the Q-clock is calibrated automatically after the Reset Phase and after data reception from the label. If this bit is set to 1, no calibration is performed automatically. 5 0 4-0 ClkQDelay This value shall not be changed This register shows the number of delay elements actually used to generate a 90 phase shift of the I-clock to obtain the Q-clock. It can be written directly by the -Processor or by the automatic calibration cycle. 43 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC 5.2.5 SL RC400 PAGE 4: RF-TIMING AND CHANNEL REDUNDANCY 5.2.5.1 Page Register Selects the register page. See 5.2.1.1 Page register. 5.2.5.2 RxWait Register Selects the time interval after transmission, before receiver starts. Name: RxWait Address: 0x21 7 6 5 Reset value: 00001000, 0x08 4 3 2 1 0 r/w r/w r/w r/w RxWait Access Rights r/w r/w r/w r/w Description of the bits Bit Symbol 7-0 RxWait Function After data transmission, the activation of the receiver is delayed for RxWait bitclocks (proportional to CoderRate). During this `frame guard time' any signal at pin Rx is ignored. 44 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC 5.2.5.3 SL RC400 ChannelRedundancy Register Selects kind and mode of checking the data integrity on the RF-channel. Name: ChannelRedundancy Access Rights Address: 0x22 Reset value: 00001100, 0x0C 7 6 5 4 3 2 1 0 0 CRCMSB First CRC 3309 CRC8 RxCRCEn TxCRCEn 0 0 r/w r/w r/w r/w r/w r/w r/w r/w Description of the bits Bit Symbol 7 0 6 CRCMSBFirst Function This value shall not be changed If set to 1, CRC-calculation shifts the MSBit into the CRC-Coprocessor first. If set to 0, CRC-calculation starts with the LSBit. Note: For usage according ISO 15693 and ICODE1 this bit has to be 0. 5 CRC 3309 If set to 1, CRC-calculation is done according ISO/IEC3309 as it is defined in ISO 15693. Note: For usage according to I*CODE1 this bit has to be 0. 4 CRC8 If set to 1, an 8-bit CRC is calculated. If set to 0, a 16-bit CRC is calculated. 3 RxCRCEn If set to 1, the last byte(s) of a received frame is/are interpreted as CRC byte/s. If the CRC itself is correct the CRC byte(s) is/are not passed to the FIFO. In case of an error, the CRCErr flag is set. If set to 0, no CRC is expected. 2 TxCRCEn If set to 1, a CRC is calculated over the transmitted data and the CRC byte(s) are appended to the data stream. If set to 0, no CRC is transmitted. 1-0 00 RFU 45 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC 5.2.5.4 SL RC400 CRCPresetLSB Register LSB of the preset value for the CRC register. Name: CRCPresetLSB 7 Address: 0x23 6 5 Reset value: 11111110, 0xFE 4 3 2 1 0 r/w r/w r/w CRCPresetLSB Access Rights r/w r/w r/w r/w r/w Description of the bits Bit Symbol Function 7-0 CRCPresetLSB CRCPresetLSB defines the starting value for CRC-calculation. This value is loaded into the CRC at the beginning of transmission, reception and the CalcCRC Command, if the CRC calculation is enabled. The Preset value is set for ICODE1 To use the ISO 15693 functionality the CRCPresetLSB Register has to be set to 0xFF. 5.2.5.5 CRCPresetMSB Register MSB of the preset value for the CRC register. Name: CRCPresetMSB 7 Address: 0x24 6 5 Reset value: 11111111, 0xFF 4 3 2 1 0 r/w r/w r/w CRCPresetMSB Access Rights r/w r/w r/w r/w r/w Description of the bits Bit Symbol Function 7-0 CRCPresetMSB CRCPresetMSB defines the starting value for CRC-calculation. This value is loaded into the CRC at the beginning of transmission, reception and the CalcCRC Command, if the CRC calculation is enabled. Note: The Preset value of CRCPresetMSB Register is the same for ICODE1 and ISO 15693. Note: This register is not relevant, if CRC8 is 1. 46 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC 5.2.5.6 SL RC400 TimeSlotPeriod Register Name: TimeSlotPeriod 7 Address: 0x25 6 5 Reset value: 00000000, 0x00 4 3 2 1 0 r/w r/w r/w TimeSlotPeriod Access Rights r/w r/w r/w r/w r/w Description of the bits Bit Symbol Function 7-0 TimeSlotPeriod TimeSlotPeriod defines the time between automatically mitted Frames. To send a Quit-Frame according to the I*CODE1 protocol, it is necessary to have a relation to the beginning of the Command-Frame. The TimeSlotPeriod will start at the End of the Command transmission. For detailed information see also chapter 9.2.5 47 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC 5.2.5.7 SL RC400 SIGOUTSelect Register Selects internal signal applied to pin SIGOUT. Name: SIGOUTSelect Access Rights Address: 0x26 Reset value:00000000, 0x00 7 6 5 4 3 0 0 0 TimeSlot Period MSB 0 r/w r/w r/w r/w r/w 2 1 0 SIGOUTSelect r/w r/w r/w Description of the bits Bit Symbol 7-5 000 4 TimeSlotPeriod MSB 3 0 2-0 SIGOUTSelect Function These values shall not be changed MSB of value TimeSlotPeriod see register 0x25 These values shall not be changed SIGOUTSelect defines which signal is routed to pin SIGOUT. 000 Constant Low 001 Constant High 010 Modulation Signal (envelope) from internal coder, actual used coded 011 Serial data stream 100 Output signal of the carrier frequency demodulator (label modulation signal) 101 Output signal of the subcarrier demodulator (Manchester coded label signal) 110 RFU 111 RFU 48 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC 5.2.5.8 SL RC400 PreSet27 Register Name: PreSet27 Access Rights Address: 0x27 Reset value: 00000000, 0x00 7 6 5 4 3 2 1 0 0 0 0 0 0 0 0 0 r/w r/w r/w r/w r/w r/w r/w r/w Note: These values shall not be changed ! 5.2.6 PAGE 5: FIFO, TIMER AND IRQ- PIN CONFIGURATION 5.2.6.1 Page Register Selects the register page. See 5.2.1.1 Page register. 5.2.6.2 FIFOLevel Register Defines the level for FIFO under- and overflow warning. Name: FIFOLevel Access Rights Address: 0x29 7 6 0 0 r/w r/w 5 Reset value:00111110, 0x3E 4 3 2 1 0 r/w r/w WaterLevel r/w r/w r/w r/w Description of the bits Bit Symbol 7-6 00 5-0 WaterLevel Function These values shall not be changed This register defines, the warning level of the SL RC400 for the -Processor for a FIFO-buffer over- or underflow: HiAlert is set to 1, if the remaining FIFO-buffer space is equal or less than WaterLevel bytes in the FIFO-buffer. LoAlert is set to 1, if equal or less than WaterLevel bytes are in the FIFO-buffer,. 49 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC 5.2.6.3 SL RC400 TimerClock Register Selects the devider for the timer clock. Name: TimerClock Access Rights Address: 0x2A 7 6 5 0 0 TAutoRestart r/w r/w r/w Reset value: 00001011, 0x0B 4 3 2 1 0 r/w r/w TPreScaler r/w r/w r/w Description of the bits Bit Symbol 7-6 00 5 TAutoRestart 4-0 TPreScaler Function These values shall not be changed If set to 1, the timer automatically restart its count-down from TReloadValue, instead of counting down to zero. If set to 0 the timer decrements to zero and the bit TimerIRq is set to 1. Defines the timer clock fTimer. TPreScaler can be adjusted from 0x00 up to 0x15. The following formula is used to calculate fTimer : fTimer = 13.56 MHz / 2TPreScaler. 50 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC 5.2.6.4 SL RC400 TimerControl Register Selects start and stop conditions for the timer. Name: TimerControl Access Rights Address: 0x2B Reset value: 00000010, 0x02 7 6 5 4 3 2 1 0 0 0 0 0 TStopRxEnd TStopRxBegin TStartTxEnd TStartTxBegin r/w r/w r/w r/w r/w r/w r/w r/w Description of the bits Bit Symbol Function 7-4 0000 3 TStopRxEnd 2 TStopRxBegin If set to 1, the timer is stopped automatically, when the first valid bit is received. 0 indicates, that the timer is not influenced by this condition. 1 TStartTxEnd If set to 1, the timer is started automatically when data transmission ends. If the timer is already running, it is restarted by loading TReloadValue into the timer. 0 indicates, that the timer is not influenced by this condition. 0 TStartTxBegin If set to 1, the timer is started automatically when the first bit is transmitted. If the timer is already running, it is restarted by loading TReloadValue into the timer. 0 indicates, that the timer is not influenced by this condition. These values shall not be changed If set to 1, the timer is stopped automatically when data reception ends. 0 indicates, that the timer is not influenced by this condition. 51 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC 5.2.6.5 SL RC400 TimerReload Register Defines the preset value for the timer. Name: TimerReload 7 Address: 0x2C 6 5 Reset value: 00000000, 0x00 4 3 2 1 0 r/w r/w r/w TReloadValue Access Rights r/w r/w r/w r/w r/w Description of the bits Bit Symbol 7-0 TReloadValue Function With a start event the timer loads with the TreloadValue. Changing this register affects the timer only with the next start event. If TReloadValue is set to 0, the timer cannot start. 52 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC 5.2.6.6 SL RC400 IRQPinConfig Register Configures the output stage for pin IRQ. Name: IRQPinConfig Access Rights Address: 0x2D Reset value: 00000010, 0x02 7 6 5 4 3 2 1 0 0 0 0 0 0 0 IRQInv IRQPushPull r/w r/w r/w r/w r/w r/w r/w r/w Description of the bits Bit Symbol 7-2 000000 These values shall not be changed 1 IRQInv If set to 1, the signal on pin IRQ is inverted with respect to bit IRq. 0 indicates, that the signal on pin IRQ is equal to bit IRQ. 0 IRQPushPull 5.2.6.7 Function If set to 1, pin IRQ works as standard CMOS output pad. 0 indicates, that pin IRQ works as open drain output pad. PreSet2E Name: PreSet2E Access Rights Address: 0x2E Reset value: 00000000, 0x00 7 6 5 4 3 2 1 0 0 0 0 0 0 0 0 0 r/w r/w r/w r/w r/w r/w r/w r/w Note: These values shall not be changed ! 5.2.6.8 Preset2F Name: Preset2F Access Rights Address: 0x2F Reset value: 00000000, 0x00 7 6 5 4 3 2 1 0 0 0 0 0 0 0 0 0 r/w r/w r/w r/w r/w r/w r/w r/w Note: These values shall not be changed ! 53 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC SL RC400 Page 6: RFU 5.2.6.9 Page Register Selects the register page. See 5.2.1.1 Page register. 5.2.6.10 RFU Registers Name: RFU Access Rights Address: 0x31, 0x32, 0x33, 0x34, 0x35, 0x36, 037 Reset value:00000000, 0x00 7 6 5 4 3 2 1 0 0 0 0 0 0 0 0 0 r/w r/w r/w r/w r/w r/w r/w r/w Note: These registers are reserved for future use. 54 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC 5.2.7 5.2.7.1 SL RC400 PAGE 7: TEST CONTROL Page Register Selects the register page. See 5.2.1.1 Page register. 5.2.7.2 RFU Register Name: RFU Address: 0x39 Reset value: 00000000, 0x00 7 6 5 4 3 2 1 0 0 0 0 0 0 0 0 0 w w w w w Access w w w Rights Note: These registers are reserved for future use. 55 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC 5.2.7.3 SL RC400 TestAnaSelect Register Selects analog test signals. Name: TestAnaSelect Access Rights Address: 0x3A Reset value: 00000000, 0x00 7 6 5 4 0 0 0 0 w w w w 3 2 1 TestAnaOutSelect w w w Description of the bits Bit Symbol 7-4 0000 3-0 TestAnaOutSel Function These values shall not be changed This register selects the internal analog signal that is routed to pin AUX. For detailed information see 18.3 Value Signal Name 0 Vmid 1 Vbandgap 2 VRxFollI 3 VRxFollQ 4 VRxAmpI 5 VRxAmpQ 6 VCorrNI 7 VCorrNQ 8 VCorrDI 9 VCorrDQ A VEvalL B VEvalR C VTemp D RFU E RFU F RFU 56 0 w Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC 5.2.7.4 SL RC400 PreSet3B Name: PreSet3B Access Rights Address: 0x3B Reset value: 00000000, 0x00 7 6 5 4 3 2 1 0 0 0 0 0 0 0 0 0 w w w w w w w w Note: These values shall not be changed ! 5.2.7.5 PreSet3C Name: PreSet3C Access Rights Address: 0x3C Reset value: 00000000, 0x00 7 6 5 4 3 2 1 0 0 0 0 0 0 0 0 0 w w w w w w w w Note: These values shall not be changed ! 57 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC 5.2.7.6 SL RC400 TestDigiSelect Register Selects digital test mode. Name: TestDigiSelect 7 Address:0x3D 6 5 Reset value: 00000000, 0x00 4 SignalTo SIGOUT Access Rights w 3 2 1 0 w w w TestDigiSignalSel w w w w Description of the bits Bit Symbol Function 7 SignalToSIGOUT Set to 1, overrules the setting in SIGOUTSelect and the digital test signal defined in TestDigiSignalSel is routed to pin SIGOUT instead. Set to 0, SIGOUTSelect defines the signal delivered at pin SIGOUT. 6-0 TestDigiSignalSel Selects the digital test signal to be routed to pin SIGOUT. For detailed information refer to chapter 18.4 5.2.7.7 TestDigiSelect Signal Name 74hex s_data 64hex s_valid 54hex s_coll 44hex s_clock 35hex rd_sync 25hex wr_sync 16hex int_clock RFU Registers Name: RFU Address: 0x3E, 0x3F Reset value: 00000000, 0x00 7 6 5 4 3 2 1 0 0 0 0 0 0 0 0 0 r/w r/w r/w r/w r/w Access r/w r/w r/w Rights Note: These registers are reserved for future use. 58 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC 5.3 SL RC400 SL RC400 Register Flags Overview Flag(s) Register Address Register, Bit Position AccessErr ErrorFlag 0x0A, bit 5 BitPhase BitPhase 0x1B, bits 7:0 ClkQ180Deg ClockQControl 0x1F, bit 7 ClkQCalib ClockQControl 0x1F, bit 6 ClkQDelay ClockQControl 0x1F, bits 4:0 CollErr ErrorFlag 0x0A, bit 0 CollLevel RxThreshold 0x1C, bits 3:0 CollPos CollPos 0x0B, bits 7:0 Command Command 0x01, bits 5:0 CRC3309 ChannelRedundancy 0x22, bit 5 CRC8 ChannelRedundancy 0x22, bit 4 CRCErr ErrorFlag 0x0A, bit 3 CRCMSBFirst ChannelRedundancy 0x22, bit 6 CRCPresetLSB CRCPresetLSB 0x23, bits 7:0 CRCPresetMSB CRCPresetMSB 0x24, bits 7:0 CRCReady SecondaryStatus 0x05 , bit 5 CRCResultMSB CRCResultMSB 0x0E, bits 7:0 CRCResultLSB CRCResultLSB 0x0D, , bits 7:0 DecoderSource RxControl2 0x1E, bits 1:0 E2Ready SecondaryStatus 0x05, bit 6 Err PrimaryStatus 0x03, bit 2 FIFOData FIFOData 0x02, bits 7:0 FIFOLength FIFOLength 0x04, bits 7:0 FIFOOvfl ErrorFlag 0x0A, bit 4 FlushFIFO Control 0x09, bit 0 FramingErr ErrorFlag 0x0A, bit 2 Gain RxControl1 0x19, bits 1:0 GsCfgCW CWConductance 0x12, bits 5:0 GsCfgMod ModConductance 0x13, bits 5:0 HiAlert PrimaryStatus 0x03, bit 1 HiAlertIEn InterruptEn 0x06, bit 1 HiAlertIRq InterruptRq 0x07, bit 1 59 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC Flag(s) SL RC400 Register Address Register, Bit Position IdleIEn InterruptEn 0x06, bit 2 IdleIRq InterruptRq 0x07, bit 2 IFDetectBusy Command 0x01, bit 7 IRq PrimaryStatus 0x03, bit 3 IRQInv IRQPinConfig 0x2D, bit 1 IRQPushPull IRQPinConfig 0x2D, bit 0 LoAlert PrimaryStatus 0x03, bit 0 LoAlertIEn InterruptEn 0x06, bit 0 LoAlertIRq InterruptRq 0x07, bit 0 SIGOUTSelect SIGOUTSelect 0x26, bits 2:0 MinLevel RxThreshold 0x1C, bits 7:4 ModemState PrimaryStatus 0x03 , bit 6:4 ModulatorSource TxControl 0x11, bits 6:5 ModWidth ModWidth 0x15, bits /:0 Page 0x00, 0x08, 0x10, 0x18, 0x20, 0x28, 0x30, 0x38, bits 2:0 PowerDown Control 0x09, bit4 RcvClkSelI RxControl2 0x1E, bit 7 RxAutoPD RxControl2 0x1E, bit 6 RxCRCEn ChannelRedundancy 0x22, bit 3 RxIEn InterruptEn 0x06, bit 3 RxIRq InterruptRq 0x07, bit 3 RxLastBits SecondaryStatus 0x05, bits 2:0 RxWait RxWait 0x21, bits 7:0 SetIEn InterruptEn 0x06, bit 67 SetIRq InterruptRq 0x07, bit 7 SignalToSIGOUT TestDigiSelect 0x3D, bit 7 StandBy Control 0x09, bit 5 TAutoRestart TimerClock 0x2A, bit 5 TestAnaOutSel TestAnaSelect 0x3A, bits 6:4 TestDigiSignalSel TestDigiSelect 0x3D, bit 6:0 TimerIEn InterruptEn 0x06, bit 5 TimerIRq InterruptRq 0x07, bit 5 TimerValue TimerValue 0x0C, bits 7:0 PageSelect 60 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC Flag(s) SL RC400 Register Address Register, Bit Position TPreScaler TimerClock 0x2A, bits 4:0 TReloadValue TimerReload 0x2C, bits 7:0 TRunning SecondaryStatus 0x05, bit 7 TStartTxBegin TimerControl 0x2B, bit 0 TStartTxEnd TimerControl 0x2B, bit 1 TStartNow Control 0x09, bit 1 TStopRxBegin TimerControl 0x2B, bit 2 TStopRxEnd TimerControl 0x2B, bit 3 TStopNow Control 0x09, bit 2 TX1RFEn TxControl 0x11, bit 0 TX2Cw TxControl 0x11, bit 3 TX2Inv TxControl 0x11, bit 3 TX2RFEn TxControl 0x11, bit 1 TxCRCEn ChannelRedundancy 0x22, bit 2 TxIEn InterruptEn 0x06, bit 4 TxIRq InterruptRq 0x07, bit 4 TxLastBits BitFraming 0x0F, bits 2:0 Page 0x00, 0x08, 0x10, 0x18, 0x20, 0x28, 0x30, 0x38, bit 7 WaterLevel FIFOLevel 0x29, bits 5:0 ZeroAfterColl DecoderControl 0x1A, bit 5 UsePageSelect 61 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC 5.4 SL RC400 Modes of Register Addressing There are three mechanisms to operate the SL RC400: * Initiating functions and controlling data manipulation by executing commands * Configuring electrical and functional behaviour via a set of configuration bits * Monitoring the state of the SL RC400 by reading status flags The commands, configurations bits and flags are accessed via the -Processor interface. The SL RC400 can internally address 64 registers. This basically requires six address lines. 5.4.1 PAGING MECHANISM The SL RC400 register set is segmented into 8 pages with 8 register each. The Page-Register can always be addressed, no matter which page is currently selected. 5.4.2 DEDICATED ADDRESS BUS Using the SL RC400 with dedicated address bus, the -Processor defines three address lines via the address pins A0, A1, and A2. This allows addressing within a page. To switch between registers in different pages the paging mechanism needs then to be used. The following table shows how the register address is assembled: Register Bit: UsePageSelect 1 Register-Address PageSelect2 PageSelect1 PageSelect0 A2 A1 A0 Table 5-3: Dedicated Address Bus: Assembling the Register Address 5.4.3 MULTIPLEXED ADDRESS BUS Using the SL RC400 with multiplexed address bus, the -Processor may define all six address lines at once. In this case either the paging mechanism or linear addressing may be used. The following table shows how the register address is assembled: Interface Bus Type Register Bit: UsePageSelect Multiplexed Address Bus (paging mode) 1 PageSelect2 PageSelect1 PageSelect0 AD2 AD1 AD0 Multiplexed Address Bus (linear addressing) 0 AD5 AD4 AD3 AD2 AD1 AD0 Register-Address Table 5-4: Multiplexed Address Bus: Assembling the Register Address 62 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC 6 SL RC400 MEMORY ORGANISATION OF THE EPROM 6.1 Diagram of the EPROM Memory Organisation Block Number Block Address Byte Addresses Access Rights Memory Content See Also 0 0 00 ... 0F r Product Information Field 6.2 1 1 10 ... 1F r/w 2 2 20 ... 2F r/w Start Up Register Initialisation File 6.3.1 3 3 30 ... 3F r/w 4 4 40 ... 4F r/w 5 5 50 ... 5F r/w 6 6 60 ... 6F r/w 7 7 70 ... 7F r/w Register Initialisation File 6.3.3 For User data or second Initialisation Table 6-1:Diagram of EPROM Memory Organisation Note: It is strictly recommended to use only the described EPROM address area. 6.2 Product Information Field (Read Only) Byte Meaning 0 1 2 3 4 5 Product Type Identification 6 RFU 7 8 9 10 11 12 Product Serial Number 13 Internal 14 15 RsMaxP CRC Table 6-2: Product Information Field PRODUCT TYPE IDENTIFICATION The SL RC400 is a member of a new family for highly integrated reader IC's. Each member of the product family has its unique Product Type Identification. The value of the Product Type Identification is shown in the table below: Product Type Identification Byte 0 1 2 3 4 Value 30hex 33hex F1hex 00hex XXhex Table 6-3: Product Type Identification Definition Byte 4 indicates the current version number. 63 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC SL RC400 PRODUCT SERIAL NUMBER The SL RC400 holds a four byte serial number that is unique for each device. INTERNAL: These 2 bytes hold internal trimming parameters. MAXIMUM SOURCE RESISTANCE FOR THE P-CHANNEL DRIVER TRANSISTOR OF PIN TX1 AND TX2 The source resistance of the p-channel driver transistors of pin TX1 and TX2 may be adjusted via the GsConfCW Register (see chapter 13.2.1). The mean value of the maximum adjustable source resistance of the pins TX1 and TX2 is stored as an integer value in Ohms in byte RsMaxP. This value is denoted as maximum adjustable source resistance Rsref,max,n and is measured with GsConfCW Register set to 01hex. It is in the range between about 80 to 120 . CRC The content of the product information field is secured via a CRC-byte, which is checked during start up. 6.3 Register Initialisation Files (Read/Write) Register initialisation in the register address range from 10hex to 2Fhex is done automatically during the Initialising Phase (see 11.3), using the Start Up Register Initialisation File. Furthermore, the user may initialise the SL RC400 registers with values from the Register Initialisation File executing the LoadConfig-Command (see 16.6.1). Notes: * The Page-Register (addressed with 10hex, 18hex, 20hex, 28hex) is skipped and not initialised. * Make sure that all PreSet registers are not changed. * Make sure, that all register bits that are reserved for future use (RFU) are set to 0. 6.3.1 START UP REGISTER INITIALISATION FILE (READ/WRITE) The content of the EPROM memory block address 1 and 2 are used to initialise the SL RC400 registers 10hex to 2Fhex during the Initialising Phase automatically. The default values written into the EPROM during production are shown in chapter 6.3.2. The assignment is the following: EPROM Byte Address Register Address Remark 10hex (Block 1, Byte 0) 10hex Skipped 11hex 11hex Copied ... ... 2Fhex Copied ... 2Fhex (Block 2, Byte 15) Table 6-4: Byte Assignment for Register Initialisation at Start Up 64 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC 6.3.2 SL RC400 SHIPMENT CONTENT OF START UP REGISTER INITIALISATION FILE During production test, the Start Up Register Initialisation File is initialised with the values shown in the table below. With each power up these values are written into the SL RC400 register during the Initialising Phase. EPROM Byte Address Reg. Address Value 10 10 00 Page: free for user 11 11 58 TxControl: Transmitter pins TX1 and TX2 switched off, bridge driver configuration, modulator driven from internal digital circuitry 12 12 3F CwConductance: Source resistance of TX1 and TX2 to minimum. 13 13 05 ModGsCfg: Source resistance of TX1 and TX2 at the time of Modulation, to determine the modulation index 14 14 2C CoderControl: Selects the bit coding mode and the framing during transmission 15 15 3F ModWidth: Pulse width for "used code (1 out of 256, RZ or 1 out of 4)" pulse coding is set to standard configuration. 16 16 3F ModWidthSOF Pulse width of SOF 17 17 00 PreSet17 18 18 00 Page: free for user 19 19 8B RxControl1: Amplifier gain is maximum. 1A 1A 00 DecoderControl: A bit-collision always evaluates to HIGH in the data bit stream. Description 1B 1B 54 BitPhase: BitPhase is set to standard configuration. 1C 1C 68 RxThreshold: MinLevel and CollLevel are set to maximum. 1D 1D 00 PreSet1D 1E 1E 41 RxControl2: Use Q-clock for the receiver, `Automatic Receiver Off' is switched on, decoder is driven from internal analog circuitry. 1F 1F 00 ClockQControl: Automatic Q-clock Calibration' is switched on. 20 20 00 Page: free for user 21 21 08 RxWait: Frame Guard Time is set to six bit clocks. 22 22 0C ChannelRedundancy: Channel Redundancy is set according to ICODE1. 23 23 FE CRCPresetLSB: CRC-Preset value is set according to ICODE1. 24 24 FF CRCPresetMSB: CRC-Preset value is set according to ICODE1. 25 25 00 PreSet25 26 26 00 SIGOUTSelect: Pin SIGOUT is set to LOW. 27 27 00 PreSet27 28 28 00 Page: free for user 29 29 3E FIFOLevel: WaterLevel: FIFO buffer warning level is set to standard configuration. 2A 2A 0B TimerClock: TPreScaler is set to standard configuration, timer unit restart function is switched off. 2B 2B 02 TimerControl: Timer is started at the end of transmission, stopped at the beginning of reception. 2C 2C 00 TimerReload: TReloadValue: the timer unit preset value is set to standard configuration 2D 2D 02 IRQPinConfig: Pin IRQ is set to high impedance. 2E 2E 00 PreSet2E 2F 2F 00 PreSet2F Table 6-5: Shipment Content of Start Up Configuration File 65 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC 6.3.3 SL RC400 REGISTER INITIALISATION FILE (READ/WRITE) The content of the EPROM memory from block address 3 to 7 may be used to initialise the SL RC400 registers 10hex to 2Fhex by execution of the LoadConfig-Command (see 16.6.1). It requires a two byte argument, that is used as the two byte long EPROM starting byte address for the initialisation procedure. The assignment is the following: EPROM Byte Address Register Address Remark Starting Byte address for the EPROM 10hex Skipped Starting Byte address for the EPROM +1 11hex Copied ... ... ... Starting Byte address for the EPROM + 31 2Fhex Copied Table 6-6: Byte Assignment for Register Initialisation at Start Up The Register Initialisation File is big enough to hold the values for two initialisation sets and leaves one more block (16 bytes) for the user. Note: The Register Initialisation File is read- and write-able for the user. Therefore, these bytes may also be used to store user specific data for other purposes. 66 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC 7 SL RC400 FIFO BUFFER 7.1 Overview An 8x64 bit FIFO buffer is implemented in the SL RC400 acting as a parallel-to-parallel converter. It buffers the input and output data stream between the -Processor and the internals of the SL RC400. Thus, it is possible to handle data streams with lengths of up to 64 bytes without taking timing constraints into account. 7.2 Accessing the FIFO Buffer 7.2.1 ACCESS RULES The FIFO-buffer input and output data bus is connected to the FIFOData Register. Writing to this register stores one byte in the FIFO-buffer and increments the internal FIFO-buffer write-pointer. Reading from this register shows the FIFO-buffer content stored at the FIFO-buffer read-pointer and increments the FIFObuffer read-pointer. The distance between the write- and read-pointer can be obtained by reading the FIFOLength Register. When the -Processor starts a command, the SL RC400 may, while the command is in progress, access the FIFO-buffer according to that command. Physically only one FIFO-buffer is implemented, which can be used in input- and output direction. Therefore the -Processor has to take care, not to access the FIFO-buffer in an unintended way. The following table gives an overview on FIFO access during command processing: Active Command -Processor is allowed to Write to FIFO Read from FIFO StartUp - - Idle - - Transmit 9 - Receive - 9 Transceive 9 9 WriteE2 9 - ReadE2 9 9 LoadConfig 9 - CalcCRC 9 - Remark -Processor has to know the actual state of the command (transmitting or receiving) The -Processor has to prepare the arguments, then only reading is allowed Table 7-1: Allowed Access to the FIFO-Buffer 7.3 Controlling the FIFO-Buffer Besides writing and reading the FIFO-buffer, the FIFO-buffer pointers may be reset by setting the bit FlushFIFO. The consequence is, that FIFOLength becomes zero, FIFOOvfl is cleared, the actually stored bytes are not accessible anymore and the FIFO-buffer can be filled with another 64 bytes again. 67 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC 7.4 SL RC400 Status Information about the FIFO-Buffer The -Processor may obtain the following data about the FIFO-buffers status: * * * * Number of bytes already stored in the FIFO-buffer: FIFOLength Warning, that the FIFO-buffer is quite full: HiAlert Warning, that the FIFO-buffer is quite empty: LoAlert Indication, that bytes were written to the FIFO-buffer although it was already full: FIFOOvfl FIFOOvfl can be cleared only by setting bit FlushFIFO. The SL RC400 can generate an interrupt signal * If LoAlertIRq is set to 1 it will activate Pin IRQ when LoAlert changes to 1. * If HiAlertIRq is set to 1 it will activate Pin IRQ when HiAlert changes to 1. The flag HiAlert is set to 1 if only WaterLevel bytes or less can be stored in the FIFO-buffer. It is generated by the following equation: HiAlert = (64 - FIFOLength) WaterLevel The flag LoAlert is set to 1 if WaterLevel bytes or less are actually stored in the FIFO-buffer. It is generated by the following equation: LoAlert = FIFOLength WaterLevel 68 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC 7.5 SL RC400 Register overview FIFO Buffer The following table shows the related flags of the FIFO buffer in alphabetic order. Flags Register Address Register, bit position FIFOLength FIFOLength 0x04, bits 6-0 FIFOOvfl ErrorFlag 0x0A, bit 4 FlushFIFO Control 0x09, bit 0 HiAlert PrimaryStatus 0x03, bit 1 HiAlertIEn InterruptIEn 0x06, bit 1 HiAlertIRq InterruptIRq 0x07, bit 1 LoAlert PrimaryStatus 0x03, bit 0 LoAlertIEn InterruptIEn 0x06, bit 0 LoAlertIRq InterruptIRq 0x07, bit 0 WaterLevel FIFOLevel 0x29, bits 5-0 Table 7-2. Registers associated with the FIFO Buffer 69 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC 8 SL RC400 INTERRUPT REQUEST SYSTEM 8.1 Overview The SL RC400 indicates certain events by setting bit IRq in the PrimaryStatus-Register and, in addition, by activating pin IRQ. The signal on pin IRQ may be used to interrupt the -Processor using its interrupt handling capabilities. This allows the implementation of efficient -Processor software. 8.1.1 INTERRUPT SOURCES OVERVIEW The following table shows the integrated interrupt flags, the related source and the condition for its setting. The interrupt flag TimerIRq indicates an interrupt set by the timer unit. The setting is done when the timer decrements from 1 either down to zero (TAutoRestart flag disabled) or to the TPreLoad value if TAutoRestart is enabled. The TxIRq bit indicates interrupts from different sources. If the transmitter is active and the state changes from sending data to transmitting the end of frame pattern, the transmitter unit sets automatically the interrupt bit. The CRC coprocessor sets TxIRq after having processed all data from the FIFO buffer. This is indicated by the flag CRCReady = 1. If the E2Prom programming has finished the TxIRq bit is set, indicated by the bit E2Ready = 1. The RxIRq flag indicates an interrupt when the end of the received data is detected. The flag IdleIRq is set if a command finishes and the content of the command register changes to idle. The flag HiAlertIRq is set to 1 if the HiAlert bit is set to one, that means the FIFO buffer has reached the level indicated by the bit WaterLevel, see chapter 7.4. The flag LoAlertIRq is set to 1 if the LoAlert bit is set to one, that means the FIFO buffer has reached the level indicated by the bit WaterLevel, see chapter 7.4. Interrupt Flag Interrupt Source TimerIRq Timer Unit the timer counts from 1 to 0 Transmitter a data stream, transmitted to the label, ends TxIRq CRC-Coprocessor Is set automatically, when all data from the FIFO buffer has been processed RxIRq Receiver a data stream, received from the label, ends IdleIRq Command Register HiAlertIRq FIFO-buffer the FIFO-buffer is getting full LoAlertIRq FIFO-buffer the FIFO-buffer is getting empty a command execution finishes Table 8-1: Interrupt Sources 70 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC 8.2 8.2.1 SL RC400 Implementation of Interrupt Request Handling CONTROLLING INTERRUPTS AND THEIR STATUS The SL RC400 informs the -Processor about the interrupt request source by setting the according bit in the InterruptRq Register. The relevance of each interrupt request bit as source for an interrupt may be masked with the interrupt enable bits of the InterruptEn Register. Register Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 InterruptEn SetIEn RFU TimerIEn TxIEn RxIEn IdleIEn HiAlertIEn LoAlertIEn InterruptRq SetIRq RFU TimerIRq TxIRq RxIRq IdleIRq HiAlertIRq LoAlertIRq Table 8-2: Interrupt Control Registers If any interrupt request flag is set to 1 (showing that an interrupt request is pending) and the corresponding interrupt enable flag is set the status flag IRq in the PrimaryStatus Register is set to 1. Furthermore, different interrupt sources can be set active simultaneously. Therefore, all interrupt request bits are `OR'ed and connected to the flag IRq and forwarded to pin IRQ. 8.2.2 ACCESSING THE INTERRUPT REGISTERS The interrupt request bits are set automatically by the internal state machines of the SL RC400. Additionally the -Processor has access in order to set or to clear them. A special implementation of the InterruptRq and the InterruptEn Register allows to change the status of a single bit without influencing the other ones. If a specific interrupt register shall be set to one, the bit SetIxx has to be set to 1 and simultaneously the specific bit has to be set to 1 too. Vice versa, if a specific interrupt flag shall be cleared, a zero has to be written to the SetIxx and simultaneously the specific address of the interrupt register has to be set to 1. If a bit content shall not be changed during the setting or clearing phase a zero has to be written to the specific bit location. Example: writing 3Fhex to the InterruptRq Register clears all bits as SetIRq in this case is set to 0 and all other bits are set to 1. Writing 81hex sets bit LoAlertIRq to 1 and leaves all other bits untouched. 8.3 Configuration of Pin IRQ The logic level of the status flag IRq is visible at pin IRQ. In addition, the signal on pin IRQ may be controlled by the following bits of the IRQPinConfig Register: * IRQInv: if set to 0, the signal on pin IRQ is equal to the logic level of bit IRq. If set to 1, the signal on pin IRQ is inverted with respect to bit IRq. * IRQPushPull: if set to 1, pin IRQ has standard CMOS output characteristics otherwise it is an open drain output and an external resistor is necessary to achieve a HIGH level at this pin. Note: During the Reset Phase (see 11.2) IRQInv is set 1 and IRQPushPull to 0. This results in a high impedance at pin IRQ. 71 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC 8.4 SL RC400 Register Overview Interrupt Request System The following table shows the related flags of the Interrupt Request System in alphabetic order. Flags Register Address Register, bit position HiAlertIEn InterruptEn 0x06, bit 1 HiAlertIRq InterruptRq 0x07, bit 1 IdleIEn InterruptEn 0x06, bit 2 IdleIRq InterruptRq 0x07, bit 2 IRq PrimaryStatus 0x03, bit 3 IRQInv IRQPinConfig 0x07, bit 1 IRQPushPull IRQPinConfig 0x07, bit 0 LoAlertIEn InterruptEn 0x06, bit 0 LoAlertIRq InterruptRq 0x07, bit 0 RxIEn InterruptEn 0x06, bit 3 RxIRq InterruptRq 0x07, bit 3 SetIEn InterruptEn 0x06, bit 7 SetIRq InterruptRq 0x07, bit 7 TimerIEn InterruptEn 0x06, bit 5 TimerIRq InterruptRq 0x07, bit 5 TxIEn InterruptEn 0x06, bit 4 TxIRq InterruptRq 0x07, bit 4 Table 8-3 Registers associated with the Interrupt Request System 72 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC 9 9.1 SL RC400 TIMER UNIT Overview A timer is implemented in the SL RC400. It derives its clock from the 13.56 MHz chip-clock. The -Processor may use this timer to manage timing relevant tasks. The timer unit may be used in one of the following configurations: * * * * * Timeout-Counter Watch-Dog Counter Stop Watch Programmable One-Shot Periodical Trigger The timer unit can be used to measure the time interval between two events or to indicate that a specific event occurred after a specific time. The timer can be triggered by events which will be explained in the following, but the timer itself does not influence any internal event. A timeout during data receiving does not influence the receiving process automatically. Furthermore, several timer related flags are set and these flags can be used to generate an interrupt. 73 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC 9.2 9.2.1 SL RC400 Implementation of the Timer Unit BLOCK DIAGRAM The following block diagram shows the timer module. TReloadValue [7:0] TStartTxBegin TxBegin Event TStartTxEnd parallel in TxEnd Event start counter / parallel load TAutoRestart TStartNow Q S TRunning Q R TStopNow stop counter Counter Module (x <= x-1) RxEnd Event TStopRxEnd RxBegin Event TStopRxBegin TPreScaler [4:0] Clock Divider 13.56 MHz >clock parallel out to Parallel Interface TimerValue [7:0] Counter = 0 ? to Interrupt Logic: TimerIRq Figure 9-1: Timer Module Block Diagram The timer unit is designed in a way, that several events in combination with enabling flags start or stop the counter. For example, setting the bit TstartTxEnd to 1 enables to control the receiving of data using the timer unit. In addition the first received bit is indicated by TxEndEvent. This combination starts the counter at the defined TReloadValue. The timer stops either automatically if the counter value is equal to zero, or if a defined stop event happens (TautoRestart not enabled). 74 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC 9.2.2 SL RC400 CONTROLLING THE TIMER UNIT The main part of the timer unit is a down-counter. As long as the down-counter value is unequal zero, it decrements its value with each timer clock. If TAutoRestart is enabled the timer does not decrement down to zero. Having reached the value 1 the timer reloads with the next clock with the TimerReload value. The timer is started by loading a value from the TimerReload Register into the counter module. This may be triggered by one of the following events: * * * * Transmission of the first bit to the label (TxBegin Event) and bit TStartTxBegin is 1 Transmission of the last bit to the label (TxEnd Event) and bit TStartTxEnd is 1 The counter module decrements down to zero and bit TAutoRestart is 1 Bit TStartNow is set to 1 (by the -Processor) Note: Every start-event re-loads the timer from the TimerReload Register. Thus, the timer unit is re-triggered. The timer can be configured to stop with one of the following events: * * * * Reception of the first valid bit from the label (RxBegin Event)and bit TStopRxBegin is set to 1 Reception of the last bit from the label (RxEnd event) and bit TStopRxEnd is set to 1 The counter module has decremented down to zero and bit TAutoRestart is set to 0 Bit TStopNow is set to 1 (by the -Processor) Loading a new value, e.g. zero, into the TimerReload Register does not immediately influence the counter, since the TimerReload Register affects the counter units content only with the next start-event. Thus, the TimerReload Register may be changed even if the timer unit is already counting. The consequence of changing the TimerReload Register will be visible after the next start-event. If the counter is stopped by setting bit TStopNow, no TimerIRq is signalled. 9.2.3 TIMER UNIT CLOCK AND PERIOD The clock of the timer unit is derived from the 13.56 MHz chip clock via a programmable divider. The clock selection is done with the TPreScaler Register, that defines the timer unit clock frequency according to the following formula: TTimerClock = 1 f TimerClock = 2T Pr eScaler 13.56MHz The possible values for the TPreScaler Register range from 0 up to 21. This results in minimum time TTimerClock of about 74 ns up to about 150 ms. The time period elapsed since the last start event is calculated with TTimer = TReLoadValue - TimerValue f TimerClock This results in a minimum time TTimer of about 74 ns up to about 40 s. 75 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC 9.2.4 SL RC400 STATUS OF THE TIMER UNIT The TRunning bit in the SecondaryStatus Register shows the timer's current status. Any configured start event starts the timer at the TReloadValue and changes the status flag TRunning to 1, any configured stop event stops the timer and sets the status flag TRunning back to 0. As long as status flag TRunning is set to 1, the TimerValue Register changes with the next timer unit clock. The actual timer unit content can be read on-the-fly via the TimerValue Register. 9.2.5 TIMESLOTPERIOD For sending of I*CODE1-Quit-Frames it is necessary to generat a exact chronological relation to the begin of the command frame. Is TimeSlotPeriod > 0, with the end of command transmission the TimeSlotPeriod starst. If there are Data in the FIFO after reaching the end of TimeSlotPeriod, these data were sent at that moment. If the FIFO is empty nothing happens. As long as the contend of TimeSlotPeriod is > 0 the counter for the TimeSlotPeriod will start automatically after reaching the end. This allows a exact time relation to the end (as well as to the beginning) of the command frame for the generation and sending of the I*CODE1-Quit-Frames Is TimeSlotPeriod > 0 the next Frame starts exact with the interval TimeSlotPeriod/CoderRate delayed after each previous Send Frame. CoderRate (see 5.2.3.5) defines the clock frequency of the coder. If TimeSlotPeriod = 0, the send function will not be triggered automatically. The contend of the register TimeSlotPeriod can be changed during the active mode. The modification take effect at the next restart of the TimeSlotPeriod. 76 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC SL RC400 Example: CoderRate = 0x05 (~52.97kHz) For I*CODE1 standard mode the interval should be 8.458ms ->TimeSlotPeriod = CoderRate * interval = 52.97kHz * 8.458ms -1 = 447 (447 = 0x1BF) Note: The MSB of the TimeSlotPeriod is in the SIGOUTSelect register see 5.2.5.7 Quit1 Command Quit2 Response1 Response2 TSP1 TSP2 TimeSlotPeriod for TSP1 TimeSlotPeriod for TSP2 I*CODE1 Standard Mode 0xBF 0x1BF I*CODE1 Fast Mode 0x5F 0x67 Note: The MSB of the TimeSlotPeriod is in the SIGOUTSelect register see 5.2.5.7 Note: It is strictly recommended that bit TxCRCEn is set to 0 (see 5.2.5.3) before the Quit-Frame is sent. If the TxCRCEn is not set to 0 a CRC value is calculated and sent with the Quit-Frame. To calculate the Quit value a CRC8 algorithm has to be used. 77 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC 9.3 9.3.1 SL RC400 Usage of the Timer Unit TIME-OUT- AND WATCH-DOG-COUNTER Having started the timer by setting TReloadValue the timer unit decrements the TimerValue Register beginning with a certain start event. If a certain stop event occurs e.g. a bit is received from the label, the timer unit stops (no interrupt is generated). On the other hand, if no stop event occurs, e.g. the label does not answer in the expected time, the timer unit decrements down to zero and generates a timer interrupt request. This signals indicate the -Processor that the expected event has not occurred in the given time TTimer. 9.3.2 STOP WATCH The time TTimer between a certain start- and stop event may be measured by the -Processor by means of the SL RC400 timer unit. Setting TReloadValue the timer starts to decrement. If the defined stop event occurs the timers stops. The time between start and stop can be calculated by T = (T Re load value - Timervalue )* TTimer if the timer does not decrements down to zero. 9.3.3 PROGRAMMABLE ONE-SHOT TIMER The -Processor starts the timer unit and waits for the timer interrupt. After the specified time TTimer the interrupt will occur (TautoRestart = 0). 9.3.4 PERIODICAL TRIGGER If the -Processor sets bit TautoRestart and TreloadValue not equal 0, it will generate an interrupt request periodically after every TTimer. 78 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC 9.4 SL RC400 Register Overview Timer Unit The following table shows the related flags of the Timer Unit in alphabetic order. Flags Register Address TAutoRestart TimerClock 0x2A, bit 5 TimerValue TimerValue 0x0C, bits 7-0 TimerReloadValue TimerReload 0x2C, bits 7-0 TPreScaler TimerClock 0x2A, bits 4-0 TRunning SecondaryStatus 0x05, bit 7 TStartNow Control 0x09, bit 1 TStartTxBegin TimerControl 0x2B, bit 0 TStartTxEnd TimerControl 0x2B, bit 1 TStopNow Control 0x09, bit 2 TStopRxBegin TimerControl 0x2B, bit 2 TStopRxEnd TimerControl 0x2B, bit 3 Table 9-1 Registers associated with the Timer Unit 79 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC 10 SL RC400 POWER REDUCTION MODES 10.1 Hard Power Down A Hard Power Down is enabled with HIGH on pin RSTPD. This turns off all internal current sinks including the oscillator. All digital input buffers are separated from the input pads and defined internally (except pin RSTPD itself). The output pins are frozen at a certain value. This is shown in the following table: SYMBOL PIN TYPE DESCRIPTION OSCIN 1 I Not separated from input, pulled to AVSS IRQ 2 O High impedance RFU 3 I Separated from Input SIGOUT 4 O LOW TX1 5 O HIGH TX2 7 O LOW NWR 9 I Separated from Input NRD 10 I Separated from Input NCS 11 I Separated from Input D0 to D7 13 to 20 I/O Separated from Input ALE 21 I Separated from Input A0 22 I/O Separated from Input A1 23 I Separated from Input A2 24 I Separated from Input AUX 27 O High impedance RX 29 I Not changed VMID 30 A Pulled to AVDD RSTPD 31 I Not changed OSCOUT 32 O HIGH Table 10-1: Signal on Pins during Hard Power Down 10.2 Soft Power Down This mode is immediately entered by setting bit PowerDown in the Control-Register. All internal current sinks are switched off (including the oscillator buffer). Different from the Hard Power Down Mode, the digital input buffers are not separated from the input pads but keep their functionality. The digital output pins do not change their state. After resetting bit PowerDown in the Control-Register it needs 512 clocks until the Soft Power Down mode is left. This is indicated by the PowerDown bit itself. Resetting it does not immediately clear it, but it is cleared automatically by the SL RC400 when the Soft Power Down Mode is left. Note: If the internal oscillator is used, you have to take into account that it is supplied by AVDD and it will take a certain time tosc until the oscillator is stable. 80 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC SL RC400 10.3 Stand By Mode This mode is immediately entered by setting bit StandBy in the Control-Register. All internal current sinks are switched off (including the internal digital clock buffer but except the oscillator buffer). Different from the Hard Power Down Mode, the digital input buffers are not separated from the input pads but keep their functionality. The digital output pins do not change their state. Different from the Soft Power Down Mode, the oscillator does not need time to wake up. After resetting bit StandBy in the Control-Register it needs 4 clocks on pin OSCIN until the Stand By Mode is left. This is indicated by the StandBy bit itself. Resetting it does not immediately clear it, but it is cleared automatically by the SL RC400 when the Stand By Mode is left. 10.4 Receiver Power Down It is power saving to switch off the receiver circuit when it is not needed and switched it on again right before data is to be received from the label. This is done automatically by setting bit RxAutoPD to 1. If it is set to 0 the receiver is continuously switched on. 81 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC 11 SL RC400 START UP PHASE The phases executed during the start up are shown in the following figure: Start Up Phase States tPD tReset tInit Hard Power Down Phase Reset Phase Initialising Phase Ready Figure 11-1: Start Up Procedure 11.1 Hard Power Down Phase The Hard Power Down Phase is active during the following cases: * Power On Reset caused by power up at pin DVDD (active while DVDD is below the digital reset threshold) * Power On Reset caused by power up at pin AVDD (active while AVDD is below the analog reset threshold) * A HIGH level on pin RSTPD (active while pin RSTPD is HIGH) 11.2 Reset Phase The Reset Phase follows the Hard Power Down Phase automatically. It takes 512 clocks. During the Reset Phase, some of the register bits are preset by hardware. The respective reset values are given in the description of each register (see 5.2.). Note: If the internal oscillator is used, you have to take into account that it is supplied by AVDD and that it will take a certain time tosc until the oscillator is stable. 11.3 Initialising Phase The Initialising Phase follows the Reset Phase automatically. It takes 128 clocks. During the Initialising Phase the content of the EPROM blocks 1 and 2 is copied into the registers 10hex to 2Fhex (see 6.3.). Note: At production test, the SL RC400 is initialised with default configuration values. This reduces the -Processors effort for configuring the device to a minimum. 82 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC SL RC400 11.4 Initialising the Parallel Interface-Type For the different connections for the different -Processor interface types (see 4.3), a certain initialising sequence shall be applied to enable a proper -Processor interface type detection and to synchronise the -Processor's and the SL RC400's Start Up. During the whole Start Up Phase, the Command value reads as 3Fhex. At the end of the Initialising Phase the SL RC400 enters the Idle Command automatically. Consequently the Command value changes to 00hex. To ensure proper detection of the -Processor interface, the following sequence shall be executed: * Read from the Command-Register until the six bit register value for Command is 00hex. The internal initialisation phase is now completed and the SL RC400 is ready to be controlled. * Write the value 80hex to the Page-Register to initialise the -Processor interface. * Read the Command-Register. If its value is 00hex the -Processor interface initialisation was successful. After interface initialisation, the linear addressing mode can be activated by writing 0x00 to the page register(s). 83 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC 12 SL RC400 OSCILLATOR CIRCUITRY SL RC400 OSCOUT OSCIN 13.56 MHz 15 pF 15 pF Figure 12-1: Quartz Connection The clock applied to the SL RC400 acts as time basis for the coder and decoder of the synchronous system. Therefore stability of clock the frequency is an important factor for proper performance. To obtain highest performance, clock jitter has to be as small as possible. This is best achieved by using the internal oscillator buffer with the recommended circuitry. If an external clock source is used, the clock signal has to be applied to pin OSCIN. In this case special care for clock duty cycle and clock jitter is needed and the clock quality has to be verified. It needs to be in accordance with the specifications in chapter 19.5.3. Remark: It is recommend not to use an external clock source. 84 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC 13 SL RC400 TRANSMITTER PINS TX1 AND TX2 The signal delivered on TX1 and TX2 is the 13.56 MHz carrier frequency modulated by an envelope signal. It can be used to drive an antenna directly, using a few passive components for matching and filtering (see chapter 17). For that, the output circuitry is designed with an very low impedance source resistance. The signal of TX1 and TX2 can be controlled via the TxControl Register. 13.1 Configuration of TX1 and TX2 The configuration possibilities of TX1 are described in the table below: Register Configuration in TxControl Envelope Signal on TX1 0 X LOW (GND) 1 0 13.56 MHz carrier frequenzy modulated 1 1 13.56 MHz carrier frequenzy TX1RFEn Table 13-1: Configurations of Pin TX1 The configuration possibilities of TX2 are described in the table below: Register Configuration in TxControl Envelope Signal on TX2 X LOW (GND) 0 13.56 MHz carrier frequenzy modulated 1 13.56 MHz carrier frequenzy 0 13.56 MHz carrier frequenzy modulated, 180 phase shift relative to TX1 1 13.56 MHz carrier frequenzy, 180 phase shift relative to TX1 0 X 13.56 MHz carrier frequenzy 1 X 13.56 MHz carrier frequenzy, 180 phase shift relative to TX1 TX2RFEn TX2CW InvTX2 0 X X 0 0 1 1 1 Table 13-2: Configurations of Pin TX2 13.2 Operating Distance versus Power Consumption The user has the possibility to find a trade-off between maximum achievable operating distance and power consumption by using different antenna matching circuits as described in Error! Reference source not found. and/or by varying the supply voltage at the antenna driver supply pin TVDD. 85 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC SL RC400 13.2.1 ANTENNA DRIVER OUTPUT SOURCE RESISTANCE The output source conductance of TX1 and TX2 for driving a HIGH level may be adjusted via the value GsCfgCW in the CwConductance Register in the range from about 1 up to 100 Ohm. The values given are relative to the reference resistance Rsrel, that is measured during production test and stored in the SL RC400 EPROM. It can be obtained from the Product Information Field (see chapter 6.2). The electrical specification can be found in chapter 19.4.3. 13.2.1.1 Source Resistance Table GsConfCW EXPGsConfCW MANTGsConfCW Rsrel GsConfCW EXPGsConfCW MANTGsConfCW Rsrel 0 0 0 24 1 8 0,0652 16 1 0 25 1 9 0,0580 32 2 0 37 2 5 0,0541 48 3 0 26 1 A 0,0522 1 0 1 1,0000 27 1 B 0,0474 17 1 1 0,5217 51 3 3 0,0467 2 0 2 0,5000 38 2 6 0,0450 3 0 3 0,3333 28 1 C 0,0435 33 2 1 0,2703 29 1 D 0,0401 18 1 2 0,2609 39 2 7 0,0386 4 0 4 0,2500 30 1 E 0,0373 5 0 5 0,2000 52 3 4 0,0350 19 1 3 0,1739 31 1 F 0,0348 6 0 6 0,1667 40 2 8 0,0338 7 0 7 0,1429 41 2 9 0,0300 49 3 1 0,1402 53 3 5 0,0280 34 2 2 0,1351 42 2 A 0,0270 20 1 4 0,1304 43 2 B 0,0246 8 0 8 0,1250 54 3 6 0,0234 9 0 9 0,1111 44 2 C 0,0225 21 1 5 0,1043 45 2 D 0,0208 10 0 A 0,1000 55 3 7 0,0200 11 0 B 0,0909 46 2 E 0,0193 35 2 3 0,0901 47 2 F 0,0180 22 1 6 0,0870 56 3 8 0,0175 12 0 C 0,0833 57 3 9 0,0156 13 0 D 0,0769 58 3 A 0,0140 23 1 7 0,0745 59 3 B 0,0127 14 0 E 0,0714 60 3 C 0,0117 50 3 2 0,0701 61 3 D 0,0108 36 2 4 0,0676 62 3 E 0,0100 15 0 F 0,0667 63 3 F 0,0093 Table 13-3: Source Resistance of n-Channel Driver Transistor of TX1 and TX2 vs. GsConfCW 86 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC SL RC400 13.2.1.2 Formula for the Source Resistance The relative resistance Rsrel is about Rsrel = 1 MANTGsConfCW ( 77 40 ) EXPGsConfCW 13.2.1.3 Calculating the Effective Source Resistance 13.2.1.3.1 Wiring Resistance Wiring and bonding adds a constant offset to the driver resistance, that is relevant if TX1 and TX2 are switched to low impedance. Rs wire ,TX 1 500m 13.2.1.3.2 Effective Resistance The source resistances of the driver transistors found in the Product Information Field (see 6.2) are measured at production test with GsModCW set to 01hex. To get the driver resistance for a specific value set in GsModCW the following formula may be used: Rs x = (Rsref ,max,n - Rswire ,TX 1 ) Rsrel + Rswire ,TX 1 . 87 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC SL RC400 13.3 Changing the Modulation Index The following table shows the modulation index, if a 50 ohm antenna is used and GsCfgCW is set to 0x3F. To change the modulation index the GsCfgMod register has to be changed similar as the GsCfgCW register. GsCfgMod rel. resistance Mod. index GsCfgMod Rrel(during modulation) Rant=50 rel. resistance Mod. index Rrel(during modulation) Rant=50 0x00 Infite 0x18 0,065 4,15% 0x10 Infite 0x19 0,058 3,63% 0x20 Infite 0x25 0,054 3,35% 0x30 Infite 0x1A 0,052 3,22% 0x01 1,000 43,45% 0x1B 0,047 2,87% 0x11 0,522 28,44% 0x33 0,047 2,82% 0x02 0,500 27,57% 0x26 0,045 2,69% 0x03 0,333 20,08% 0x1C 0,043 2,58% 0x21 0,270 16,83% 0x1D 0,040 2,33% 0x12 0,261 16,33% 0x27 0,039 2,22% 0x04 0,250 15,73% 0x1E 0,037 2,12% 0x05 0,200 12,88% 0x34 0,035 1,95% 0x13 0,174 11,32% 0x1F 0,035 1,93% 0x06 0,167 10,88% 0x28 0,034 1,86% 0x07 0,143 9,38% 0x29 0,030 1,58% 0x31 0,140 9,21% 0x35 0,028 1,43% 0x22 0,135 8,89% 0x2A 0,027 1,35% 0x14 0,130 8,59% 0x2B 0,025 1,17% 0x08 0,125 8,23% 0x36 0,023 1,08% 0x09 0,111 7,32% 0x2C 0,023 1,01% 0x15 0,104 6,86% 0x2D 0,021 0,88% 0x0A 0,100 6,57% 0x37 0,020 0,82% 0x0B 0,091 5,95% 0x2E 0,019 0,77% 0x23 0,090 5,89% 0x2F 0,018 0,67% 0x16 0,087 5,68% 0x38 0,018 0,63% 0x0C 0,083 5,43% 0x39 0,016 0,48% 0x0D 0,077 4,98% 0x3A 0,014 0,36% 0x17 0,075 4,81% 0x3B 0,013 0,26% 0x0E 0,071 4,59% 0x3C 0,012 0,18% 0x32 0,070 4,50% 0x3D 0,011 0,11% 0x24 0,068 4,32% 0x3E 0,010 0,05% 0x0F 0,067 4,26% 0x3F 0,009 0,00% Note: If the output source conductance (GsCfgCW) has been changed GsCfgMod must also be changed to get the same modulation index. 88 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC SL RC400 13.4 Pulse Width The envelope carries the information of the data signal, that shall be transmitted to the label. This is done by coding the data signal according to the 1 out of 256, RZ or 1 out of 4 code. Furthermore, each pause of the coded signal again is coded as a pulse of certain length. The width of this pulse can be adjusted by means of the ModWidth Register. The pulse length is calculated by TPulse = 2 ModWidth + 1 fC where fc = 13.56MHz. 89 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC 14 SL RC400 RECEIVER CIRCUITRY 14.1 General The SL RC400 employs an integrated quadrature-demodulation circuit which extracts the sub-carrier signal from the 13.56 MHz ASK-modulated signal applied to pin RX. The quadrature-demodulator uses two different clocks, Q- and I-clock, with a phase shift of 90 between them. Both resulting subcarrier signals are amplified, filtered and forwarded to the correlation circuitry. The correlation results are evaluated, digitised and passed to the digital circuitry. For all processing units various adjustments can be made to obtain optimum performance. 14.2 Block Diagram Figure 14-1 shows the block diagram of the receiver circuitry. The receiving process includes several steps. First the quadrature demodulation of the carrier signal of 13.56 MHz is done. To achieve an optimum in performance an automatic clock Q calibration is recommended (see 14.3.1). The demodulated signal is amplified by an adjustable amplifier. A correlation circuit calculates the degree of similarity between the expected and the received signal. The bit phase register allows to align the position of the correlation intervals with the bit grid of the received signal. In the evaluation and digitizer circuitry the valid bits are detected and the digital results are send to the FIFO register. Several tuning steps in this circuit are possible. ClockQDelay[4:0] ClockQCalib ClockQ180 BitPhase[7:0] CollLevel[3:0] Gain[1:0] I to Q Conversion I-clock MinLevel[3:0] RcvClkSelI RxWait[7:0] clock Q-clock s_valid RX 13.56 MHz Demodulator Correlation Circuitry Evaluation and Digitizer Circuitry s_data s_coll s_clock VRxFollQ VRxFollI VRxAmpQ VCorrNI VCorrDI VRxAmpI VCorrNQ VCorrDQ VEvalR VEvalL to TestAna OutSel Figure 14-1: Block Diagram of Receiver Circuitry The user may observe the signal on its way through the receiver as shown in the block diagram above. One signal at a time may be routed to pin AUX using the TestAnaSelect-Register as described in 18.3. 90 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC SL RC400 14.3 Putting the Receiver into Operation In general, the default settings programmed into the Start Up Initialisation File are suitable to use the SL RC400 for data communication with I*CODE labels. However, in some environments specific user settings may achieve better performance. 14.3.1 AUTOMATIC CLOCK-Q CALIBRATION The quadrature demodulation concept of the receiver generates a phase signal I-clock and a 90 shifted quadrature signal Q-clock. To achieve an optimum demodulator performance, the Q- and the I-clock have to have a difference in phase of 90. After the reset phase of the SL RC400, a calibration procedure is done automatically. It is possible to have an automatic calibration done at the ending of each Transceive command. To do so, the ClkQCalib bit has to be configured to a value of 0. Configuring this bit to a constant value of 1 disables all automatic calibrations except the one after the reset sequence. It is also possible to initiate one automatic calibration by software. This is done with a 0 to 1 transition of bit ClkQCalib. The details: calibration impulse from reset sequence a rising edge initiates a clock Q calibration calibration impulse from ending of TRANSEIVE command the ClkQCalib bit Note: The duration of the automatic clock Q calibration is at most 65 oscillator periods which is approx. 4,8s. The value of ClkQDelay is proportional to the phase shift between the Q- and the I-clock. The status flag ClkQ180Deg shows, that the phase shift between the Q- and the I-clock is greater than 180. Notes: * The startup configuration file enables an automatically Q-clock calibration after the reset. * While ClkQCalib is 1, no automatic calibration is done. Therefore leaving this bit 1 can be used to permanently disable the automatic calibration. * It is possible to write data to ClkQDelay via the -Processor. The aim could be a disabling of the automatic calibration and to pre-set the delay by software. But notice, that configuring the delay value by software requires that bit ClkQCalib has already been set to 1 before and that a time interval of at least 4.8s has elapsed since then. Each delay value must be written with the ClkQCalib bit set to 1. If ClkQCalib is 0 the configured delay value will be overwritten by the next interval automatic calibration. 91 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC SL RC400 14.3.2 AMPLIFIER The demodulated signal has to be amplified with the variable amplifier to achieve the best performance. The gain of the amplifiers can be adjusted by means of the register bits Gain[1:0]. The following gain factors are selectable: Register Setting Gain Factor (Simulation Results) Gain Factor [dB] (Simulation Results) 0 22 26.9 1 35 30.9 2 82 38.3 3 130 42.2 Table 14-1: Gain Factors for the Internal Amplifier 92 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC SL RC400 14.3.3 CORRELATION CIRCUITRY The correlation circuitry calculates the degree of matching between the received and an expected signal. The output is a measure for the amplitude of the expected signal in the received signal. This is done for both, the Q- and the I-channel. The correlator delivers two outputs for each of the two input channels, resulting in four output signals in total. For optimum performance, the correlation circuitry needs the phase information for the signal coming from the label. This information has to be defined by the -Processor by means of the register BitPhase[7:0]. This value defines the phase relation between the transmitter and receiver clock in multiples of tBitPhase = 1/13.56 MHz. 14.3.4 EVALUATION AND DIGITIZER CIRCUITRY For each bit-half of the Manchester coded signal the correlation results are evaluated. The evaluation and digitizer circuit decides from the signal strengths of both bit-halves, whether the current bit is valid, and, if it is valid, the value of the bit itself or whether the current bit-interval contains a collision. To do this in an optimum way, the user may select the following levels: * MinLevel: Defines the minimum signal strength of the stronger bit-half's signal for being considered valid. * CollLevel: Defines the minimum signal strength that has to be exceeded by the weaker half-bit of the Manchester-coded signal to generate a bit-collision. If the signal's strength is below this value, a 1 and 0 can be determined unequivocally. CollLevel defines the minimum signal strength relative to the amplitude of the stronger half-bit. After transmission of data, the label is not allowed to send its response before a certain time period, called frame guard time in the standard ISO 15693 (similar to I*CODE1). The length of this time period after transmission shall be set in the RxWait-Register. The RxWait-Register defines when the receiver is switched on after data transmission to the label in multiples of one bit-duration. If register bit RcvClkSelI is set to 1, the I-clock is used to clock the correlator and evaluation circuits. If set to 0, the Q-clock is used. Note: It is recommended to use the Q-clock. 93 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC 15 SL RC400 SERIAL SIGNAL SWITCH 15.1 General Two main blocks are implemented in the SL RC400. A digital circuitry, comprising state machines, coder and decoder logic and so on and an analog circuitry with the modulator and antenna drivers, receiver and amplification circuitry. The interface between these two blocks can be configured in the way, that the interfacing signals may be routed to the pin SIGOUT. 15.2 Block Diagram Figure 15-1 describes the serial signal switches. Three different switches are implemented in the serial signal switch in order to use the SL RC400 in different configurations. The serial signal switch may also be used during the design In phase or for test purposes to check the transmitted and received data. Chapter 18.2, describes analog test signals as well as measurements at the serial signal switch. 0 0 Serial Data Out 1 out of 256 or RZ or 1 out of 4 1 1 Envelope 2 RFU 3 Modulator Driver Tx1 Tx2 2 Modulator Source (Part of) Serial Data Processing Manchester 5 Carrier Demodulator Rx 3 SigOut Select Manchester with Subcarrier 4 Subcarrier Demodulator RFU Transmitt NRZ 3 1 1 0 0 Decoder Source 6 Envelope 3 RFU 2 RFU Manchester Out 2 RFU 2 Serial Data In 0 1 Internal Manchester Decoder 7 0 (Part of) Analog Circuitry 1 0 Digital Test Signal SignalTo SigOut Serial Signal Switch SIGOut Figure 15-1: Serial Signal Switch The following chapters describe the relevant registers used to configure and control the serial signal switch. 94 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC SL RC400 15.3 Registers Relevant for the Serial Signal Switch The flags DecoderSource define the input signal for the internal Manchester decoder in the following way: Input Signal for Decoder DecoderSource 0 Constant 0 1 Output of the analog part. This is the default configuration. 2 RFU 3 RFU Table 15-1: Values for DecoderSource ModulatorSource defines the signal that modulates the transmitted 13.56 MHz carrier frequenzy. The modulated signal drives the pins TX1 and TX2. Input Signal for Modulator ModulatorSource 0 Constant 0 (carrier frequency off at pin TX1 and TX2). 1 Constant 1 (continuous carrier frequency delivered at pin TX1 and TX2). 2 Modulation signal (envelope) from the internal coder. This is the default configuration. 3 RFU Table 15-2: Values for ModulatorSource SIGOUTSelect defines the input signal for the internal Manchester decoder in the following way: Signal Routed to Pin SIGOUT SIGOUTSelect 0 Constant 0 1 Constant 1 2 Modulation signal (envelope) from the internal coder. 3 Serial data stream that is to be transmitted (same as for SIGOUTSelect = 2, but not coded by the "selected" pulse coder yet). 4 Output signal of the receiver circuit (label modulation signal regenerated and delayed) 5 Output signal of the sub-carrier demodulator (Manchester-coded label signal) 6 RFU 7 RFU Table 15-3: Values for SIGOUTselect Note: To use SIGOUTSelect, the value of test signal control bit SignalToSIGOUT has to be 0. 95 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC 16 SL RC400 SL RC400 COMMAND SET 16.1 General Description The SL RC400 behaviour is determined by an internal state machine that is capable to perform a certain set of commands. These commands are started by writing the according command-code to the CommandRegister. Arguments and/or data necessary to process a command are exchanged via the FIFO buffer. 16.2 General Behaviour * Each command, that needs a data stream (or data byte stream) as input will immediately process the data it finds in the FIFO buffer. * Each command, that needs a certain number of arguments will start processing only when it has received the correct number of arguments via the FIFO buffer. * The FIFO buffer is not cleared automatically at command start. Therefore, it is also possible to write the command arguments and/or the data bytes into the FIFO buffer and start the command afterwards. * Each command (except the StartUp-Command) may be interrupted by the -Processor by writing a new command code into the Command-Register e.g.: the Idle-Command. 96 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC SL RC400 16.3 SL RC400 Commands Overview Command Code Action Arguments and Data passed via FIFO Returned Data via FIFO see Chapter - - 16.3.2 - - 16.3.3 - 16.4.1 Data Stream 16.4.2 Data Stream 16.4.3 - 16.5 Data Bytes 16.5.2 Runs the Reset- and Initialisation Phase. StartUp 3Fhex Idle 00hex No action: cancels current command execution. Transmit 1Ahex Transmits data from the FIFO buffer to the label. Note: This command can not be activated by software, but only by a Power-On or Hard Reset Data Stream Activates Receiver Circuitry. Receive 16hex Note: Before the receiver actually starts, the state machine waits until the time configured in the register RcvWait has passed. - Note: This command may be used for test purposes only, since there is no timing relation to the TransmitCommand. Transmits data from FIFO buffer to the label and activates automatically the receiver after transmission. Transceive 1Ehex Note: Before the receiver actually Data Stream starts, the SL RC400 waits until the time configured in the register RcvWait has passed. Note: This command is the combination of Transmit and Receive WriteE2 01hex Gets data from FIFO buffer and writes it to the internal EPROM. Start Address LSB Start Address MSB Data Byte Stream ReadE2 03hex Reads data from the internal EPROM and puts it into the FIFO buffer. Start Address LSB Start Address MSB Number of Data Bytes LoadConfig 07hex Reads data from EPROM and initialises the SL RC400 registers. Start Address LSB Start Address MSB - 16.6.1 Data Byte-Stream - 16.5 Activates the CRC-Coprocessor. CalcCRC 12hex Note: The result of the CRC calculation can be read from the registers CRCResultLSB and CRCResultMSB Table 16-1: SL RC400 Command Overview 97 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC SL RC400 16.3.1 BASIC STATES 16.3.2 STARTUP COMMAND 3FHEX Command Action Codehex Arguments and Data Returned Data - - Runs the Reset- and Initialisation Phase StartUp 3F Note: This command can not be activated by software, but only by a Power-On or Hard Reset The StartUp-Command runs the Reset- and Initialisation Phase. It does not need or return any data. It can not be activated by the -Processor but is started automatically after one of the following events: * Power On Reset caused by power up at Pin DVDD * Power On Reset caused by power up at Pin AVDD * Negative Edge at Pin RSTPD The Reset-Phase defines certain register bits by an asynchronous reset. The Initialisation-Phase defines certain registers with values taken from the EPROM. When the StartUp-Command has finished, the Idle-Command is entered automatically. Notes: * The -Processor must not write to the SL RC400 as long as the SL RC400 is busy executing the StartUp-Command. To ensure this, the -Processor shall poll for the Idle-Command to determine the end of the Initialisation Phase (see also chapter 11.4). * As long as the StartUp-Command is active, only reading from page 0 of the SL RC400 is possible. * The StartUp-Command can not be interrupted by the -Processor. 16.3.3 IDLE COMMAND 00HEX Command Codehex Action Arguments and Data Returned Data Idle 00 No action: cancels current command execution - - The Idle-Command switches the SL RC400 to its inactive state. In this Idle-state it waits for the next command. It does not need or return any data. The device automatically enters the Idle-state when a command finishes. In this case the SL RC400 simultaneously initiates an interrupt request by setting bit IdleIRq. Triggered by the -Processor, the Idle-Command may be used to stop execution of all other commands (except the StartUp Command). In that case no IdleIRq is generated. Remark: Stopping a command with the Idle Command does not clear the FIFO buffer content. 98 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC SL RC400 16.4 Commands for Label Communication The SL RC400 is a fully ISO 15693 and I*CODE1 compliant reader IC. The following chapter describe the command set for label communication in general. 16.4.1 TRANSMIT COMMAND 1AHEX Command Codehex Transmit 1A Action Arguments and Data Transmits data from FIFO buffer to the label Data Stream Returned Data - The Transmit-Command takes data from the FIFO buffer and forwards it to the transmitter. It does not return any data. The Transmit-Command can only be started by the -Processor. 16.4.1.1 Working with the Transmit Command To transmit data one of the following sequences may be used: 1. All data, that shall be transmitted to the label is written to the FIFO while the Idle-Command is active. After that, the command code for the Transmit-Command is written to the Command-Register. Note: This is possible for transmission of data with a length of up to 64 bytes. 2. The command code for the Transmit-Command is written to Command-Register first. Since no data is available in the FIFO, the command is only enabled but transmission is not triggered yet. Data transmission really starts with the first data byte written to the FIFO. To generate a continuous data stream on the RF-interface, the -Processor has to put the next data bytes to the FIFO in time. Note: This allows transmission of data of any length but requires that data is available in the FIFO in time. 3. A part of the data, that shall be transmit to the label is written to the FIFO while the Idle-Command is active. After that, the command code for the Transmit-Command is written to the Command-Register. While the Transmit-Command is active, the -Processor may feed further data to the FIFO, causing the transmitter to append it to the transmitted data stream. Note: This enables transmission of data of any length but requires that data is available in the FIFO in time. When the transmitter requests the next data byte to keep the data stream on the RF-interface continuous but the FIFO buffer is empty, the Transmit-Command automatically terminates. This causes the internal state machine to change its state from Transmit to Idle. If data transmission to the label is finished, the SL RC400 sets the flag TxIRq to signal it to the -Processor. Remark: If the -Processor overwrites the transmit code in the Command-Register with the Idle-Command or any other command, transmission stops immediately with the next clock cycle. This may produce output signals that are not according to the standard ISO 15693 or the I*CODE1 protocol. 99 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC SL RC400 16.4.1.2 RF-Channel Redundancy and Framing Each transmitted ISO 15693 frame consists of a SOF (start of frame) pattern, followed by the data stream and is closed by an EOF (end of frame) pattern. All I*CODE1 command frames consists of a START PULSE followed by the data stream. The I*CODE1 commands have a fix length and no EOF is needed. These different phases of the transmit sequence may be monitored by watching ModemState of PrimaryStatusRegister (see 16.4.4). Depending on the setting of bit TxCRCEn in the ChannelRedundancy-Register a CRC is calculated and appended to the data stream. The CRC is calculated according the settings in the ChannelRedundancy Register. 16.4.1.3 Transmission of Frames with more than 64 Bytes To generate frames with more than 64 bytes, the -Processor has to write data into the FIFO buffer while the Transmit Command is active. The state machine checks the FIFO status when it starts transmitting the last bit of the actual data stream (the check time is marked below with arrows). TxLastBits TxLastBits = 0 FIFO Length 0x01 0x00 FIFO empty TxData Bit7 Bit0 Bit7 Bit0 Bit7 Check FIFO empty Accept Further Data Figure 16-1: Timing for Transmitting Byte Oriented Frames As long as the internal signal `Accept Further Data' is 1 further data may be loaded into the FIFO. The SL RC400 appends this data to the data stream transmitted via the RF-interface. If the internal signal `Accept Further Data' is 0 the transmission will terminate. All data written into the FIFO buffer after `Accept Further Data' went 0 will not be transmitted anymore, but remain in the FIFO buffer. 100 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC SL RC400 16.4.2 RECEIVE COMMAND 16HEX Command Codehex Receive 16 Action Activates Receiver Circuitry Arguments and Data Returned Data - Data Stream The Receive-Command activates the receiver circuitry. All data received from the RF interface is returned via the FIFO buffer. The Receive-Command can be started either by the -Processor or automatically during execution of the Transceive-Command. Note: This command may be used for test purposes only, since there is no timing relation to the TransmitCommand. 16.4.2.1 Working with the Receive Command After starting the Receive Command the internal state machine decrements the value set in the RxWaitRegister with every bit-clock. From 3 down to 1 the analog receiver circuitry is prepared and activated. When the counter reaches 0, the receiver starts monitoring the incoming signal at the RF-interface. If the signal strength reaches a level higher than the value set in the MinLevel-Register it finally starts decoding. The decoder stops, if no more signal can be detected on the receiver input pin Rx. The decoder indicates termination of operation by setting bit RxIRq. The different phases of the receive sequence may be monitored by watching ModemState of the PrimaryStatus-Register (see 16.4.4). Note: Since the counter values from 3 to 0 are necessary to initialise the analog receiver circuitry the minimum value for RxWait is 3. 16.4.2.2 RF-Channel Redundancy and Framing For ISO 15693 the decoder expects a SOF pattern at the beginning of each data stream. If a SOF is detected, it activates the serial to parallel converter and gathers the incoming data bits. For I*CODE1 the decoder do not expects a SOF pattern at the beginning of each data stream. It activates the serial to parallel converter with the first received bit of the data. Every completed byte is forwarded to the FIFO. If an EOF pattern (ISO15693) is detected or the signal strength falls below MinLevel set in the RxThreshold Register, the receiver and the decoder stop, the Idle-Command is entered and an appropriate response for the Processor is generated (interrupt request activated, status flags set). If bit RxCRCEn in the ChannelRedundancy Register is set a CRC block is expected. The CRC block may be one byte or two bytes according to bit CRC8 in the ChannelRedundancy Register. Remark: The received CRC block is not forwarded to the FIFO buffer if it is correct. This is realised by shifting the incoming data bytes through an internal buffer of either one or two bytes (depending on the defined CRC). The CRC block remains in this internal buffer. As a consequence all data bytes are available in the FIFO buffer one or two bytes delayed. If the CRC fails all received bytes are forwarded to the FIFO buffer (including the faulty CRC itself). 101 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC SL RC400 16.4.2.3 Collision Detection If more than one label is within the RF-field during the label selection phase, they will respond simultaneously. The SL RC400 supports the algorithm defined in ISO 15693 as well as the I*CODE1 anticollision algorithm to resolve data-collisions of label serial numbers by doing the so-called anti-collision procedure. The basis for this is the ability to detect bit-collisions. Bit-collision detection is supported by the used bit-coding scheme, namely the Manchester-coding. If in the first and second half-bit of a bit a sub-carrier modulation is detected, instead of forwarding a 1 or a 0 a bit collision will be signalled. To distinguish a 1 or 0-bit from a bit-collision, the SL RC400 uses the setting of CollLevel. If the amplitude of the half-bit with smaller amplitude is larger than defined by CollLevel, the SL RC400 indicates a bit-collision. If a bit-collision is detected, the error flag CollErr is set. Independent from the detected collision the receiver continues receiving the incoming data stream. In case of a bit-collision, the decoder forwards 1 at the collision position. Note: As an exception, if bit ZeroAfterColl is set, all bits received after the first bit-collision are forced to zero, regardless whether a bit-collision or an unequivocal state has been detected. This feature eases for the software to carry out the anti-collision procedure defined in ISO 15693. When the first bit collision in a frame is detected, the bit position of this collision is stored in the CollPos Register. The collision position follows the table below: Collision in Bit Value of CollPos SOF 0 LSBit of LSByte 1 ... ... MSBit of LSByte 8 LSBit of second Byte 9 ... ... MSBit of second Byte 16 LSBit of third Byte 17 ... ... Table 16-2: Returned Values for Bit Collision Positions If a collision is detected in the SOF a frame error is reported and no data is forwarded to the FIFO buffer. In this case the receiver continues to monitor the incoming signal and generates the correct notifications to the -Processor when the ending of the faulty input stream is detected. This helps the -Processor to determine the time when it is allowed next to send anything to the label. 102 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC SL RC400 16.4.2.4 Communication Errors The following table shows which event causes the setting of error flags: Cause Bit, that is set Received data did not start with a SOF pattern. FramingErr The CRC block is not equal the expected value. CRCErr The received data is shorter than the CRC block. CRCErr A collision is detected. CollErr Table 16-3: Communication Error Table 16.4.3 TRANSCEIVE COMMAND 1EHEX Command Codehex Transceive 1E Action Arguments and Data Transmits data from FIFO buffer to the label and then activates automatically the receiver Data Stream Returned Data Data Stream The Transceive-Command first executes the Transmit-Command (see 16.4.1) and then automatically starts the Receive-Command (see 16.4.2). All data that shall be transmitted is forwarded via the FIFO buffer and all data received is returned via the FIFO buffer. The Transceive-Command can be started only by the -Processor. Note: To adjust the timing relation between transmitting and receiving, the RxWait Register is used to define the time delay from the last bit transmitted until the receiver is activated. Furthermore, the BitPhase Register determines the phase-shift between the transmitter and the receiver clock. 16.4.4 STATES OF THE LABEL COMMUNICATION The actual state of the transmitter and receiver state machine can be fetched from ModemState in the PrimaryStatus Register. The assignment of ModemState to the internal action is shown in the following table: ModemState Name of State Description 000 Idle 001 TxSOF Transmitting the `Start Of Frame' Pattern 010 TxData Transmitting data from the FIFO buffer (or redundancy check bits) 011 TxEOF Transmitting the `End Of Frame' Pattern Neither the transmitter nor the receiver is in operation, since none of them is started or the transmitter has not got input data GoToRx1 Intermediate state passed, when receiver starts GoToRx2 Intermediate state passed, when receiver finishes 101 PrepareRx Waiting until the time period selected in the RxWait Register has expired 110 AwaitingRx Receiver activated; Awaiting an input signal at pin Rx 111 Receiving 100 Receiving data Table 16-4: Meaning of ModemState 103 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC SL RC400 16.4.5 STATE DIAGRAM FOR THE LABEL COMMUNICATION Command = (Transmit OR Receive OR Transceive) FI C FO (T omm no t ra ns a n em m d = pty it AN O R D Tr an sc ei ve ) Idle (000) Co m Re ma ce nd iv e = GoToRx1 (100) TxSOF (001) next bit clock SOF transmitted TxData (010) PrepareRx (101) RxMultiple = 1 && TimeSlotPeriod > 0 && TimeSlot Trigger && Data in FIFO RxWaitCounter =0 Data transmitted TxEOF (011) AwaitingRx (110) Signal Strength > MinLevel EOF transmitted AND Command = Transceive Receiving (111) EOF transmitted AND Command = Transmit Frame Received End of Receive frame && RxMultiple = 0 && TimeSlotPeriod = 0 Set CommandRegister = Idle (000) GoToRx2 (100) RxMultiple = 0 && TimeSlotPeriod > 0 && TimeSlot Trigger && Data in FIFO Idle (000) Preparing to send the Quit value Remark: I*CODE1 do not have a SOF and a EOF 104 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC SL RC400 16.5 Commands to Access the EPROM 16.5.1 WRITEE2 COMMAND 01HEX 16.5.1.1 Overview Command Codehex WriteE2 01 Arguments and Data passed via FIFO Action Get data from FIFO buffer and write it to the EPROM Start Address LSB Start Address MSB Data Byte Stream Returned Data via FIFO - The WriteE2-Command interprets the first two bytes in the FIFO buffer as EPROM starting byte-address. Any further bytes are interpreted as data bytes and are programmed into the EPROM, starting from the given EPROM starting byte-address. This command does not return any data. The WriteE2-Command can only be started by the -Processor. It will not stop automatically but has to be stopped explicitly by the -Processor by issuing the Idle-Command. 16.5.1.2 Programming Process One byte up to 16 byte can be programmed into the E2PROM in one programming cycle. The time needed will be in any case about 5.8ms. The state machine copies all data bytes prepared in the FIFO buffer to the EPROM input buffer. The internal EPROM input buffer is 16 byte long which is equal the block size of the EPROM. A programming cycle is started either if the last position of the EPROM input buffer is written or if the last byte of the FIFO buffer has been fetched. As long as there are unprocessed bytes in the FIFO buffer or the EPROM programming cycle still is in progress, the flag E2Ready is 0. If all data from the FIFO buffer are programmed into the EPROM, the flag E2Ready is set to1. Together with the rising edge of E2Ready the interrupt request flag TxIRq indicates a 1. This may be used to generate an interrupt when programming of all data is finished. After the E2Ready bit is set to 1, the WriteE2-Command may be stopped by the -Processor by issuing the Idle-Command. Important: The WriteE2-Command must not be stopped by starting another command before the E2Ready flag is set to 1. Otherwise the content of the currently processed EPROM block will not be defined or in worst case the SL RC400 functionality is in-reversibly reduced. 105 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC SL RC400 16.5.1.3 Timing Diagram The following diagram shows programming of 5 bytes into the EPROM: tprg,del NWrite Data WriteE2 command active EPROM Programming Write Adr E2 LSB Adr MSB Byte0 Byte1 Byte2 Byte3 Idle Cmd Byte4 tprog tprog Programming Byte0 Programming Byte1, Byte2, and Byte3 tprog Programming Byte4 E2Ready TxIRq Figure 16-3: Timing Diagram for EPROM programming Explanation: It is assumed, that the SL RC400 finds and reads Byte 0 before the -Processor is able to write Byte 1 (tprog,del = 300 ns). This causes the SL RC400 to start the programming cycle, which needs about tprog = 2.9 ms. In the meantime the -Processor stores Byte 1 to Byte 4 to the FIFO buffer. Assuming, that the EPROM starting byte-address is e.g. 4Chex then Byte 0 is stored exactly there. The SL RC400 copies the following data bytes into the EPROM input buffer. Copying Byte 3, it detects, that this data byte has to be programmed at the EPROM byte-address 4Fhex. Since this is the end of the memory block, the SL RC400 automatically starts a programming cycle. In the next turn, Byte 4 will be programmed at the EPROM byteaddress 50hex. Since this is the last data byte, the flags (E2Ready and TxIRq) that indicate the end of the EPROM programming activity will be set. Although all data has been programmed into the E2PROM, the SL RC400 stays in the WriteE2-Command. Writing further data to the FIFO would lead to further EPROM programming, continuing at the EPROM byte-address 51hex. The command is stopped using the Idle-Command. 16.5.1.4 Error Flags for the WriteE2 Command Programming is inhibited for the EPROM blocks 0 (EPROM's byte-address 00hex to 0Fhex). Programming to these addresses sets the flag AccessErr. No programming cycle is started (for the EPROM memory organisation refer to chapter 6.). It is strictly recommended to use only the described EPROM address area. 106 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC SL RC400 16.5.2 READE2 COMMAND 03HEX 16.5.2.1 Overview Command Codehex ReadE2 03 Action Arguments Reads data from EPROM and puts it to the FIFO buffer Start Address LSB Start Address MSB Number of Data Bytes Returned Data Data Bytes The ReadE2-Command interprets the first two bytes found in the FIFO buffer as EPROM starting byte-address. The next byte specifies the number of data bytes that shall be returned. When all three argument-bytes are available in the FIFO buffer, the specified number of data bytes is copied from the EPROM into the FIFO buffer, starting from the given EPROM starting byte-address. The ReadE2-Command can be triggered only by the -Processor. It stops automatically when all data has been delivered. Note: It is strictly recommended to use only the described EPROM address area. 107 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC SL RC400 16.6 Diverse Commands 16.6.1 LOADCONFIG COMMAND 07HEX 16.6.1.1 Overview Command Codehex LoadConfig 07 Action Arguments and Data Reads data from EPROM and initialises the registers Start Address LSB Start Address MSB Returned Data - The LoadConfig-Command interprets the first two bytes found in the FIFO buffer as EPROM starting byte-address. When the two argument-bytes are available in the FIFO buffer, 32 bytes from the EPROM are copied into the SL RC400 control and configuration registers, starting at the given EPROM starting byte-address. The LoadConfig-Command can only be started by the -Processor. It stops automatically when all relevant registers have been copied. Note: It is strictly recommended to use only the described EPROM address area. 16.6.1.2 Register Assignment The 32 bytes of EPROM content, beginning with the EPROM starting byte-address, is written to the SL RC400 register 10hex up to register 2Fhex (for the EPROM memory organisation see 6). Note: The procedure for the register assignment is the same as it is for the Start Up Initialisation (see 11.3). The difference is, that the EPROM starting byte-address for the Start Up Initialisation is fixed to 10hex (Block 1, Byte 0). With the LoadConfig-Command it can be chosen. 16.6.1.3 Relevant Error Flags for the LoadConfig-Command Valid EPROM starting byte-addresses are in the range from 10hex up to 60hex. 16.6.2 CALCCRC COMMAND 12HEX 16.6.2.1 Overview Command Codehex CalcCRC 12 Action Arguments and Data Activates the CRC-Coprocessor Data Byte-Stream Returned Data - The CalcCRC-Command takes all data from the FIFO buffer as input bytes for the CRC-Coprocessor. All data stored in the FIFO buffer before the command is started will be processed. This command does not return any data via the FIFO buffer, but the content of the CRC-register can be read back via the CRCResultLSB-register and the CRCResultMSB-register. The CalcCRC-Command can only be started by the -Processor. It does not stop automatically but has to be stopped explicitly by the -Processor with the Idle-Command. If the FIFO buffer is empty, the CalcCRC-Command waits for further input from the FIFO buffer. Note: Do not use this command to calculate the Quit value for ICODE1 tag's because this would terminate the Transceive command. 108 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC SL RC400 16.6.2.2 CRC-Coprocessor Settings For the CRC-Coprocessor the following parameters may be configured: Parameter Value Bit Register CRC Register Length 8 Bit or 16 Bit CRC CRC8 ChannelRedundancy CRC Algorithm 1 = Algorithm according ISO 15693 or according ISO/IEC3309 CRC3309 ChannelRedundancy 0 = algorithm according to I*CODE1 Bit-Processing Direction Shift the MSBit or LSBit first into the CRCregister CRCMSBFirst ChannelRedundancy CRC Preset Value Any CRCPresetLSB, CRCPresetMSB CRCPresetLSB, CRCPresetMSB Table 16-5: CRC-Coprocessor Parameters The CRC polynomial for the 8-bit CRC is fixed to x + x + x + x + 1 . 8 4 16 The CRC polynomial for the 16-bit CRC is fixed to x 3 2 + x12 + x 5 + 1 . 16.6.2.3 Status Flags of the CRC-Coprocessor The status flag CRCReady indicates, that the CRC-Coprocessor has finished processing of all data bytes found in the FIFO buffer. With the CRCReady flag setting to 1, an interrupt is requested with TxIRq being set. This supports interrupt driven usage of the CRC-Coprocessor. When CRCReady and TxIRq are set to 1, respectively, the content of the CRCResultLSB- and CRCResultMSB-register and the flag CRCErr is valid. The CRCResultLSB- and CRCResultMSB-register hold the content of the CRC register, the CRCErr flag indicates CRC validity for the processed data. 16.7 Error Handling during Command Execution If any error is detected during command execution, this is shown by setting the status flag Err in the PrimaryStatus Register. For information about the cause of the error, the -Processor may evaluate the status flags in the ErrorFlag Register. Error Flag of the ErrorFlag Register Related to Command AccessError WriteE2, ReadE2, LoadConfig FIFOOvl Not related to a command CRCErr Receive, Transceive, CalcCRC FramingErr Receive, Transceive CollErr Receive, Transceive Table 16-6: Error Flags Overview 109 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC 17 SL RC400 TYPICAL APPLICATION 17.1 Circuit Diagram The figure below shows a typical application, where the antenna is direct connected to the SL RC400: DVDD DVDD Reset AVDD RSTPD AVDD Processor Data Bus IRQ TVDD TX1 Processor Bus Control Lines TVDD C1 L0 C0 C2a C0 C2b TVSS IRQ SL RC400 TX2 L0 R1' C1 RX R1 DVSS OSCIN OSCOUT AVSS VMID R2 C4 100 nF 13.56 MHz 15 pF 15 pF Figure 17-1: Circuit Diagram for Application Example: Direct Matched Antenna 110 C3 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC SL RC400 17.2 Circuit Description The matching circuit consists of an EMC low pass filter (L0 and C0), a matching circuitry (C1 and C2), and a receiving circuit (R1, R2, C3 and C4), and the antenna itself. For more detailed information about designing and tuning an antenna please refer to the Application Note 'MIFARE(R) and ICODE MICORE reader IC family; Directly Matched Antenna Design' 17.2.1 EMC LOW PASS FILTER The ICODE system operates at a frequency of 13.56 MHz. This frequency is generated by a quartz oscillator to clock the SL RC400 and is also the basis for driving the antenna with the 13.56 MHz energy carrier. This will not only cause emitted power at 13.56 MHz but will also emit power at higher harmonics. The international EMC regulations define the amplitude of the emitted power in a broad frequency range. Thus, an appropriate filtering of the output signal is necessary to fulfil these regulations. A multi-layer board it is recommended to implement a low pass filter as shown in the circuit above. The low pass filter consists of the components L0 and C0. The recommended values are given in the above mentioned application notes. Note: To achieve best performance all components shall have at least the quality of the recommended ones. Note: The layout has a major influence on the overall performance of the filter. 17.2.2 ANTENNA MATCHING Due to the impedance transformation of the given low pass filter, the antenna coil has to be matched to a certain impedance. The matching elements C1 and C2 can be estimated and have to be fine tuned depending on the design of the antenna coil. The correct impedance matching is important to provide the optimum performance. The overall Quality factor has to be considered to guarantee a proper ICODE communication scheme. Environmental influences have to considered as well as common EMC design rules. For details refer to the above mentioned application notes. Note: Do not exceed the current limits ITVDD, otherwise the chip might be destroyed. Note: The overall 13.56MHz RFID proximity antenna design with the SL RC400 chip is straight forward and doesn't require a special RF-know how. However, all relevant parameters have to be considered to guarantee an overall optimum performance together with international EMC compliance. 111 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC SL RC400 17.2.3 RECEIVING CIRCUIT The internal receiving concept of the SL RC400 makes use of both side-bands of the sub-carrier load modulation of the label response. No external filtering is required. It is recommended to use the internally generated VMID potential as the input potential of pin RX. This DC voltage level of VMID has to be coupled to the Rx-pin via R2. To provide a stable DC reference voltage a capacitance C4 has to be connected between VMID and ground. Considering the (AC) voltage limits at the Rx-pin the AC voltage divider of R1 + C3 and R2 has to be designed. Depending on the antenna coil design and the impedance matching the voltage at the antenna coil varies from antenna design to antenna design. Therefore the recommended way to design the receiving circuit is to use the given values for R1, R2, and C3 from the above mentioned Application Note, and adjust the voltage at the Rx-pin by varying R1 within the given limits. Note: R2 is AC-wise connected to ground (via C4). 17.2.4 ANTENNA COIL The precise calculation of the antenna coils' inductance is not practicable but the inductance can be estimated using the following formula. We recommend designing an antenna either with a circular or rectangular shape. l 1,8 L1 [nH ] = 2 l 1 [cm ] ln 1 - K N1 D1 l1 ............... Length of one turn of the conductor loop D1 ............. Diameter of the wire or width of the PCB conductor respectively K............... Antenna Shape Factor (K = 1,07 for circular antennas and K = 1,47 for square antennas) N1 ............. Number of turns ln .............. Natural logarithm function The actual values of the antenna inductance, resistance, and capacitance at 13.56 MHz depend on various parameters like: * * * * * antenna construction (Type of PCB) thickness of conductor distance between the windings shielding layer metal or ferrite in the near environment Therefore a measurement of those parameters under real life conditions, or at least a rough measurement and a tuning procedure is recommended to guarantee the optimum performance. For details refer to the above mentioned application notes. 112 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC 18 SL RC400 TEST SIGNALS 18.1 General The SL RC400 allows different kind of signal measurements. These measurements can be used to check the internally generated and received signals using the possibilities of the serial signal switch as described in chapter 15. Furthermore, with the SL RC400 the user may select internal analog signals to measure them at pin AUX and internal digital signals to observe them on pin SIGOUT by register selections. These measurements can be helpful during the design-in phase to optimise the receiver's behaviour or for test purpose. 18.2 Measurements Using the Serial Signal Switch Using the serial signal switch at pin SIGOUT the user may observe data send to the label or data received from the label. The following tables give an overview of the different signals available. SignalToSIGOUT SIGOUTSelect Signal routed to SIGOUT pin 0 0 LOW 0 1 HIGH 0 2 Envelope 0 3 Transmit NRZ 0 4 Manchester with Subcarrier 0 5 Manchester 0 6 RFU 0 7 RFU 1 X Digital Test signal Table 18-1 Signal routed to SIGOUT pin 113 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC SL RC400 18.3 Analog Test-Signals The analog test signals may be routed to pin AUX by selecting them with the register bits TestAnaOutSel. Value Signal Name Description 0 Vmid 1 Vbandgap Internal reference voltage generated by the band gap. 2 VRxFollI Output signal from the demodulator using the I-clock. 3 VRxFollQ Output signal from the demodulator using the Q-clock. 4 VRxAmpI I-channel subcarrier signal amplified and filtered. 5 VRxAmpQ Q-channel subcarrier signal amplified and filtered. 6 VCorrNI Output signal of N-channel correlator fed by the I-channel subcarrier signal. 7 VCorrNQ Output signal of N-channel correlator fed by the Q-channel subcarrier signal. 8 VCorrDI Output signal of D-channel correlator fed by the I-channel subcarrier signal. 9 VCorrDQ Output signal of D-channel correlator fed by the Q-channel subcarrier signal. A VEvalL Evaluation signal from the left half bit. B VEvalR Evaluation signal from the right half bit. C VTemp Temperature voltage derived from band gap. D RFU Reserved for future use E RFU Reserved for future use F RFU Reserved for future use Voltage at internal node Vmid Table 18-2: Analog Test Signal Selection 114 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC SL RC400 18.4 Digital Test-Signals Digital test signals may be routed to pin SIGOUT by setting bit SignalToSIGOUT to 1. A digital test signal may be selected via the register bits TestDigiSignalSel in Register TestDigiSelect. The signals selected by a certain TestDigiSignalSel setting is shown in the table below: TestDigiSignalSel Signal Name Description F4hex s_data Data received from the label. E4hex s_valid Shows with 1, that the signals s_data and s_coll are valid. D4hex s_coll Shows with 1, that a collision has been detected in the current bit. C4hex s_clock Internal serial clock: during transmission, this is the coder-clock and during reception this is the receiver clock. D5hex rd_sync Internal synchronised read signal (derived from the parallel -Processor interface). C5hex wr_sync Internal synchronised write signal (derived from the parallel -Processor interface). 96hex int_clock Internal 13.56 MHz clock. 00hex no test signal output as defined by SIGOUTSelect are routed to pin SIGOUT. Table 18-3: Digital Test Signal Selection If no test signals are used, the value for the TestDigiSel-Register shall be 00hex. Note: All other values of TestDigiSignalSel are for production test purposes only. 115 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC SL RC400 18.5 Examples of Analog- and Digital Test Signals Fig. 17 shows the answer of an I*CODE1 Label IC to a unselected read command using the Qclock receiving path. RX -Reference is given to show the Manchester modulated signal at the RX pin. This signal is demodulated and amplified in the receiver circuitry VRXAmpQ shows the amplified side band signal having used the QClock for demodulation. The signals VCorrDQ and VCorrNQ generated in the correlation circuitry are evaluated and digitised in the evaluation and digitizer circuitry. VEvalR and VEvalL show the evaluation signal of the right and left half bit. Finally, the digital test-signal S_data shows the received data which is send to the internal digital circuit and S_valid indicates that the received data stream is valid. Receiving path Q-Clock VrxAmpQ VcorrDQ VcorrNQ VevalR VevalL Sdata 50sec/Dev. SValid 500sec/Dev. Figure 17. Receiving path Q-Clock 116 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC 19 SL RC400 ELECTRICAL CHARACTERISTICS 19.1 Absolute Maximum Ratings SYMBOL PARAMETER MIN MAX UNIT Ambient or Storage Temperature Range -40 +150 C DC Supply Voltages -0.5 6 V Vin,abs Absolute voltage on any digital pin to DVSS -0.5 DVDD + 0.5 V VRX,abs Absolute voltage on RX pin to AVSS -0.5 AVDD + 0.5 V Tamb,abs DVDD AVDD TVDD Table 19-1: Absolute Maximum Ratings 19.2 Operating Condition Range SYMBOL PARAMETER Tamb Ambient Temperature DVDD Digital Supply Voltage AVDD Analog Supply Voltage TVDD Transmitter Supply Voltage CONDITIONS MIN TYP MAX UNIT - -25 +25 +85 C 4.5 5.0 5.5 V 4.5 5.0 5.5 V 3.0 5.0 5.5 V TYP MAX UNIT Idle Command 8 11 mA Stand By Mode 3 5 mA Soft Power Down Mode 800 1000 A Hard Power Down Mode 1 10 A Idle Command, Receiver On 25 40 mA Idle Command, Receiver Off 12 15 mA Stand By Mode 10 13 mA Soft Power Down Mode 1 10 A Hard Power Down Mode 1 10 A 150 mA DVSS = AVSS = TVSS = 0V Table 19-2: Operating Condition Range 19.3 Current Consumption SYMBOL IDVDD IAVDD PARAMETER CONDITIONS Digital Supply Current Analog Supply Current MIN Continuous Wave ITVDD Transmitter Supply Current TX1 and TX2 unconnected TX1RFEn, TX2RFEn = 1 5.5 7 mA TX1 and TX2 unconnected TX1RFEn, TX2RFEn = 0 65 130 A Table 19-3: Current Consumption 117 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC SL RC400 19.4 Pin Characteristics 19.4.1 INPUT PIN CHARACTERISTICS Pins D0 to D7, A0 and A1 have TTL input characteristics and behave as defined in the following table. SYMBOL PARAMETER ILeak VT CONDITIONS MIN MAX UNIT Input Leakage Current -1.0 +1.0 A Threshold 0.8 2.0 V Table 19-4: Standard Input Pin Characteristics The digital input pins NCS, NWR, NRD, ALE and A2 have Schmitt-Trigger characteristics, and behave as defined in the following table. SYMBOL PARAMETER ILeak CONDITIONS MIN MAX UNIT Input Leakage Current -1.0 +1.0 A VT+ Positive-Going Threshold 1.4 2.0 V VT- Negative-Going Threshold 0.8 1.3 V Table 19-5: Schmitt-Trigger Input Pin Characteristics Pin RSTPD has Schmitt-Trigger CMOS characteristics. In addition, it is internally filtered with an RC-lowpass filter, which causes a relevant propagation delay for the reset signal: SYMBOL PARAMETER ILeak CONDITIONS MIN MAX UNIT Input Leakage Current -1.0 +1.0 A VT+ Positive-Going Threshold 0.65 DVDD 0.75 DVDD V VT- Negative-Going Threshold 0.25 DVDD 0.4 DVDD V tRSTPD,p Propagation Delay 20 s MAX UNIT 15 pF Table 19-6: RSTPD Input Pin Characteristics The analog input pin RX has the following input capacitance: SYMBOL PARAMETER CRX Input Capacitance CONDITIONS Table 19-7: RX Input Capacitance 118 MIN Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC SL RC400 19.4.2 DIGITAL OUTPUT PIN CHARACTERISTICS Pins D0 to D7, SIGOUT and IRQ have TTL output characteristics and behave as defined in the following table. SYMBOL PARAMETER VOH Output Voltage HIGH VOL Output Voltage LOW IO Output Current source or sink CONDITIONS MIN TYP MAX UNIT DVDD = 5 V, IOH = -1 mA 2.4 4.9 V DVDD = 5 V, IOH = -10 mA 2.4 4.2 V DVDD = 5 V, IOL = 1 mA 25 400 mV DVDD = 5 V, IOL = 10 mA 250 400 mV 10 mA DVDD = 5 V Table 19-8:Digital Output Pin Characteristics Note: IRQ pin may also be configured as open collector. In that case the values for VOH do not apply. 19.4.3 ANTENNA DRIVER OUTPUT PIN CHARACTERISTICS The source conductance of the antenna driver pins TX1 and TX2 for driving the HIGH level can be configured via GsCfgCW in the CwConductance Register, while their source conductance for driving the LOW level is constant. For the default configuration, the output characteristic is specified below: SYMBOL PARAMETER VOH Output Voltage HIGH VOL Output Voltage LOW ITX Transmitter Output Current CONDITIONS MIN TYP MAX UNIT TVDD = 5.0 V, IOL = 20 mA 4.97 V TVDD = 5.0 V, IOL = 100 mA 4.85 V TVDD = 5.0 V, IOL = 20 mA 30 mV TVDD = 5.0 V, IOL = 100 mA 150 mV Continuous Wave Table 19-9:Antenna Driver Output Pin Characteristics 119 200 mApeak Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC SL RC400 19.5 AC Electrical Characteristics 19.5.1 AC SYMBOLS Each timing symbol has five characters. The first character is always 't' for time. The other characters indicate the name of a signal or the logic state of that signal (depending on position): Designation: Signal: Designation: Logic Level: A address H HIGH D data L LOW W NWR or nWait Z high impedance R NRD or R/NW or nWrite X any level or data L ALE or AS V any valid signal or data C NCS S NDS or nDStrb and nAStrb Example: tAVLL = time for address valid to ALE low 120 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC SL RC400 19.5.2 AC OPERATING SPECIFICATION 19.5.2.1 Bus Timing for Separated Read/Write Strobe SYMBOL PARAMETER MIN tLHLL ALE pulse width 20 MAX UNIT tAVLL Multiplexed Address Bus valid to ALE low (Address Set Up Time) 15 ns tLLAX Multiplexed Address Bus valid after ALE low (Address Hold Time) 8 ns ns tLLWL ALE low to NWR, NRD low 15 ns tCLWL NCS low to NRD, NWR low 0 ns tWHCH NRD, NWR high to NCS high 0 tRLDV NRD low to DATA valid ns 65 ns tRHDZ NRD high to DATA high impedance 20 ns tWLDV NWR low to DATA valid 35 ns tWHDX DATA hold after NWR high (Data Hold Time) 8 ns tWLWH NRD, NWR pulse width 65 ns tAVWL Separated Address Bus valid to NRD, NWR low (Set Up Time) 30 ns tWHAX Separated Address Bus valid after NWR high (Hold Time) 8 ns tWHWL period between sequenced read / write accesses 150 ns Table 19-10: Timing Specification for Separated Read/Write Strobe tLHLL ALE tCLWL tWHCH NCS tLLWL tWHWL tWLWH tWHWL NWR NRD tAVLL D0 ... D7 tWLDV tRLDV tLLAX Multiplexed Addressbus tWHDX tRHDZ D0 ... D7 A0 ... A2 tAVWL tWHAX Separated Addressbus A0 ... A2 A0 ... A2 Figure 19-1: Timing Diagram for Separated Read/Write Strobe Note: For separated address and data bus the signal ALE is not relevant and the multiplexed addresses on the data bus don't care. For the multiplexed address and data bus the address lines A0 to A2 have to be connected as described in 4.3. 121 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC SL RC400 19.5.2.2 Bus Timing for Common Read/Write Strobe SYMBOL tLHLL tAVLL tLLAX tLLSL tCLSL tSHCH tSLDV,R tSHDZ tSLDV,W tSHDX tSHRX tSLSH tAVSL tSHAX tSHSL tRVSL PARAMETER AS pulse width Multiplexed Address Bus valid to AS low (Address Set Up Time) Multiplexed Address Bus valid after AS low (Address Hold Time) AS low to NDS low NCS low to NDS low NDS high to NCS high NDS low to DATA valid (for read cycle) NDS low to DATA high impedance (read cycle) NDS low to DATA valid (for write cycle) DATA hold after NDS high (write cycle, Hold Time) R/NW hold after NDS high NDS pulse width Separated Address Bus valid to NDS low (Hold Time) Separated Address Bus valid after NDS high (Set Up Time) period between sequenced read/write accesses R/NW valid to NDS low MIN 20 15 8 15 0 0 MAX 65 20 35 8 8 65 30 8 150 8 UNIT ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns Table 19-11: Timing Specification for Common Read/Write Strobe tLHLL ALE tCLSL tSHCH NCS tRVSL tSHRX R/NW tLLSL tSHSL tSLSH tSHSL NDS tAVLL D0 ... D7 tSLDV,R tSLDV,W tLLAX Multiplexed Addressbus tSHDX tSHDZ D0 ... D7 A0 ... A2 tAVSL tSHAX Separated Addressbus A0 ... A2 A0 ... A2 Figure 19-2: Timing Diagram for Common Read/Write Strobe Note: For separated address and data bus the signal ALE is not relevant and the multiplexed addresses on the data bus don't care. For the multiplexed address and data bus the address lines A0 to A2 have to be connected as described in 4.3. 122 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC SL RC400 19.5.2.3 Bus Timing for EPP SYMBOL PARAMETER MIN tLLLH nAStrb pulse width 20 MAX UNIT tAVLH Multiplexed Address Bus valid to nAStrb high (Set Up Time) 15 ns tLHAX Multiplexed Address Bus valid after nAStrb high (Hold Time) 8 ns ns tCLSL NCS low to nDStrb low 0 ns tSHCH nDStrb high to NCS high 0 ns tSLDV,R nDStrb low to DATA valid (read cycle) 65 ns tSHDZ nDStrb low to DATA high impedance (read cycle) 20 ns 35 ns tSLDV,W nDStrb low to DATA valid (write cycle, Set up Time) tSHDX DATA hold after nDStrb high (write cycle, Hold Time) tSHRX nWrite hold after nDStrb high 8 ns tSLSH nDStrb pulse width 65 ns 8 8 ns tRVSL nWrite valid to nDStrb low tSLWH nDStrb low to nWait high 75 ns ns tSHWL nDStrb high to nWait low 75 ns Table 19-12: Timing Specification for Common Read/Write Strobe tCLSL tSHCH NCS tRVSL tSHRX nWrite tSLSH nDStrb nAStrb tSLDV,R tSLDV,W tSHDX tSHDZ D0 ... D7 A0 ... A7 D0 ... D7 tSLWH tSHWL nWait Figure 19-3: Timing Diagram for Common Read/Write Strobe Remark: The figure does not distinguish between the Address Write Cycle and a Data Write Cycle. Take in account, that timings for the Address Write and Data Write Cycle different. For the EPP-Mode the address lines A0 to A2 have to be connected as described in 4.3. 123 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC SL RC400 19.5.3 CLOCK FREQUENCY The clock input is pin 1, OSCIN. PARAMETER SYMBOL Clock Frequency (checked by the clock filter) fOSCIN Duty Cycle of Clock Frequency dFEC Jitter of Clock Edges tjitter MIN TYP MAX 13.56 40 50 UNIT MHz 60 % 10 ps The clock applied to the SL RC400 acts as time basis for the coder and decoder of the synchronous system. Therefore stability of clock frequency is an important factor for proper performance. To obtain highest performance, clock jitter shall be as small as possible. This is best achieved using the internal oscillator buffer with the recommended circuitry (see 12). 124 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC 20 SL RC400 E2PROM CHARACTERISTICS The EPROM has a size of 8x16x8 = 1.024 bit. SYMBOL PARAMETER CONDITIONS MIN tEEEndurance Data Endurance tEERetention Data Retention UNIT tEEErase Erase Time 2.9 ms tEEWrite Write Time 2.9 ms 100.000 erase/write cycles 10 years Tamb 55C Table 20-1:EPROM Characteristics 125 MAX Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC 21 SL RC400 PACKAGE OUTLINES 21.1 SO32 SO32: plastic small outline package; 32 leads; body width 7.5 mm SOT287-1 D E A X c y HE v M A Z 17 32 Q A2 pin 1 index A (A3 ) A1 Lp L 16 1 0 detail X w M bp e 5 10 mm scale DIMENSIONS (inch dimensions are derived from the original mm dimensions) A UNIT max. A1 A2 A3 bp c D (1) E (1) e HE mm inches 2.65 0.10 0.3 0.1 2.45 2.25 0.012 0.096 0.004 0.086 10.65 10.00 L Lp Q 1.4 1.1 0.4 1.2 1.0 0.25 0.49 0.36 0.27 0.18 20.7 20.3 7.6 7.4 1.27 0.01 0.02 0.01 0.011 0.007 0.81 0.80 0.30 0.29 0.419 0.043 0.047 0.055 0.050 0.394 0.016 0.039 v 0.25 0.01 w 0.25 0.01 y Z (1) 0.1 0.95 0.55 0.037 0.004 0.022 8o 0o Note 1. Plastic or metal protrusions of 0.15 mm maximum per side are not included. OUTLINE VERSION REFERENCES IEC JEDEC EIAJ EUROPEAN PROJECTION ISSUE DATE 95-01-25 97-05-22 SOT287-1 Figure 21-1: Outline and Dimension of SL RC400 in SO32 126 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC 22 SL RC400 TERMS AND ABBREVIATIONS Designation: Description: -Processor Micro Processor EPROM Electrically Erasable Programmable Read Only Memory EOF End of Frame FWT Frame Waiting Time: maximum time delay between last bit transmitted by the reader and first bit received from the label's response. ICODE A family of hard-wired logic contactless label ICs. The protocol of these labels is according to I*CODE1 and ISO 15693. On top they use a fixed set of commands. POR Power On Reset: triggers a reset, caused by a rising edge on a supply pin. ROM Read Only Memory SOF Start of Frame 127 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC 23 SL RC400 DEFINITIONS Data sheet status Objective specification This data sheet contains target or goal specifications for product development. Preliminary specification This data sheet contains preliminary data; supplementary data may be published later. Product specification This data sheet contains final product specifications. Limiting values Limiting values given are in accordance with the Absolute Maximum Rating System (IEC 134). Stress above one or more of the limiting values may cause permanent damage to the device. These are stress ratings only and operation of the device at these or at any other conditions above those given in the Characteristics section of the specification is not implied. Exposure to limiting values for extended periods may affect device reliability. Application information Where application information is given, it is advisory and does not form part of the specification. 24 LIFE SUPPORT APPLICATIONS These products are not designed for use in life support appliances, devices, or systems where malfunction of these products can reasonably be expected to result in personal injury. Philips customers using or selling these products for use in such applications do so on their own risk and agree to fully indemnify Philips for any damages resulting from such improper use or sale. 128 Philips Semiconductors Product Specification Rev. 3.1 August 2004 I*CODE Reader IC 25 SL RC400 REVISION HISTORY REVISION DATE 1.0 2.0 3.1 CPCN PAGE DESCRIPTION First published version 14.11.01 Preliminary version 17.08.04 Update current consumption Table 19-3 Update register description 0x14, 0x19 Update Table 18-3 Change from preliminary to product specification Table 25-1: Document Versions Up to Revision 1.0 129 Philips Semiconductors - a worldwide company Contact Information For additional information please visit http://www.semiconductors.philips.com.Fax: +31 40 27 24825 For sales offices addresses send e-mail to: sales.addresses@www.semiconductors.philips.com. (c) Koninklijke Philips Electronics N.V. 2002 SCA74 All rights are reserved. Reproduction in whole or in part is prohibited without the prior written consent of the copyright owner. The information presented in this document does not form part of any quotation or contract, is believed to be accurate and reliable and may be changed without any notice. No liability will be accepted by the publisher for any consequence of its use. Publication thereof does not convey nor imply any license under patent- or other industrial or intellectual property rights. PHILIPS SEMICONDUCTORS