Sealed Snap Action Switch D2VW 1
Sealed Snap Action Switch
D2VW
Watertight Miniature Snap Action Switch
High-quality watertight, high-precision miniature Snap
Action switch. Switch Body meets IP67 requirements
Use of epoxy resin assures high sealing capability and is
ideal for dusty places or where water is sprayed
V-series internal mechanism assures high precision and
long life
General-load (5 A at 250 VAC) models and micro-load
models are available
RoHS Compliant
Ordering Information
Note: 1. The standard lengths of the lead wires (UL1015 AWG20 for UL/CSA models, AV0.75f otherwise) of models incorporating them are 300 mm.
Add “-0” to the end of the part number to obtain 1,000 mm long wires. (e.g.: D2VW-5L2A-1MS-0)
2. Remove “-HS” from the end of solder/quick-connect models to obtain non-UL/CSA versions. (e.g.: D2VW-01-1HS D2VW-01-1)
3. Remove “S” from the end of lead wire models to obtain non-UL/CSA versions with AV0.75f wire. (e.g.: D2VW-5L3-1MS D2VW-5L3-1M)
Model Number Legend
Actuator Terminal Model
Model 0.1 A Model 5 A
Pin plunger With solder and #187 tab terminals D2VW-01-1HS D2VW-5-1HS
With lead wires D2VW-01-1MS D2VW-5-1MS
Short hinge lever With solder and #187 tab terminals D2VW-01L1A-1HS D2VW-5L1A-1HS
With lead wires D2VW-01L1A-1MS D2VW-5L1A-1MS
Hinge lever With solder and #187 tab terminals D2VW-01L1-1HS D2VW-5L1-1HS
With lead wires D2VW-01L1-1MS D2VW-5L1-1MS
Long hinge lever With solder and #187 tab terminals D2VW-01L1B-1HS D2VW-5L1B-1HS
With lead wires D2VW-01L1B-1MS D2VW-5L1B-1MS
Simulated roller lever With solder and #187 tab terminals D2VW-01L3-1HS D2VW-5L3-1HS
With lead wires D2VW-01L3-1MS D2VW-5L3-1MS
Short hinge roller lever With solder and #187 tab terminals D2VW-01L2A-1HS D2VW-5L2A-1HS
With lead wires D2VW-01L2A-1MS D2VW-5L2A-1MS
Hinge roller lever With solder and #187 tab terminals D2VW-01L2-1HS D2VW-5L2-1HS
With lead wires D2VW-01L2-1MS D2VW-5L2-1MS
D2VW- - -
1. Ratings
5: 5 A at 250 VAC
01: 0.1 A at 30 VDC
2. Actuator
None: Pin plunger
L1A: Short hinge lever
L1: Hinge lever
L1B: Long hinge lever
L3: Simulated roller lever
L2A: Short hinge roller lever
L2: Hinge roller lever
3. Contact Form
1: SPDT
2: SPST-NC
3: SPST-NO
4. Terminals
None, HS: Solder terminals
(HS for UL and CSA approval.)
M, MS: Molded lead wires
5. Length of the molded lead wire
None: 300 mm
0: 1,000 mm
(MS for UL and CSA approval)
3 4 521
2Sealed Snap Action Switch D2VW
Specifications
Characteristics
Note: 1. Data shown are of initial value.
2. The dielectric strength shown is measured using a separator between the switch and metal mounting plate.
3. For the pin plunger models, the above values apply for use at the free position and total travel position. For the lever models, the values
apply at the total travel position.
4. The operating temperature of the lead wire (AV0.75f) for non-UL/CSA molded lead wire models is between -40 to 85°C.
Ratings (reference values)
D2VW-5
D2VW-01
Note: 1. The resistive load ratings apply under the following test conditions:
Ambient Temperature = 20±2°C, Ambient Humidity = 65±5%, Operating frequency = 30 operations/min.
2. The above current ratings are the values of the steady-state current.
3. Inductive load has a power factor of 0.7 min. (AC) and a time constant of 7 ms max. (DC).
4. Lamp load has an inrush current of 10 times the steady-state current.
5. Rating for UL/CSA approval is as follows (See “Approved Standards” section):
Model D2VW-01 D2VW-5
Operating speed 0.1 mm to 1 m/s (at pin plunger)
Operating frequency Mechanical: 300 operations/minute max.
Electrical: 60 operations/minute max.
Insulation resistance 100 MΩmin. (at 500 VDC)
Contact resistance 50 mΩmax. for solder terminal models
100 mΩmax. for 300 mm molded lead wire models
200 mΩmax. for 1,000 mm molded lead wire models
Dielectric strength (See note 2) 1,000 VAC, 50/60 Hz for 1 min. between terminals of the same polarity
1,500 VAC, 50/60 Hz for 1 min. between each current-carrying metal parts and ground, and
between each terminal and non-current-carrying metal parts.
Vibration resistance (See note 3) Malfunction: 10 to 55 Hz, 1.5 mm double amplitude
Shock resistance (See note 3) Destruction: 1,000 m/s2(approx. 100G) max.
Malfunction: 300 m/s2(approx. 30G) max.
Degree of protection IEC IP67 (excluding the terminals on terminal models).
Degree of protection against electric shock Class I
Proof tracking index (PTI) 175
Ambient operating temperature -40°to 85°C (at 60% RH max.) with no icing
Ambient operating humidity 95% max. (for 5°Cto35°C)
Life expectancy Mechanical 10,000,000 operations min. at 60 operations per minute
Electrical
1,000,000 operations min. at 30 ops. per minute.
100,000 operations min. at 30 ops. per minute
Weight Approx. 7g (pin plunger models without wires)
Rated Voltage Non-inductive load Inductive load
Resistive load Lamp load Inductive load Motor load
NC NO NC NO NC NO NC NO
125 VAC 5 A 0.5 A 4 A
250 VAC 5 A 0.5 A 4 A
30VDC 5A 3A 4A
125 VDC 0.4 A 0.1 A 0.4 A
Rated Voltage Non-inductive load Inductive load
Resistive load Lamp load Inductive load Motor load
NC NO NC NO NC NO NC NO
125 VAC 0.1 A
30 VDC 0.1 A
D2VW-01 0.1A @ 125 VAC
0.1A @ 30 VDC
D2VW-5 3A @ 125 VAC, 250 VAC
Sealed Snap Action Switch D2VW 3
Approved Standards
Consult your OMRON sales representative for specific models with
standard approvals.
UL Recognized, CSA Certified
EN 61058-1 (VDE Approval)
Testing conditions:
25E3 (25,000 operations), T55 (0°Cto55°C) for D2VW-5
1E5 (100,000 operations), T85 (0°Cto85°C) for D2VW-01
Contact Specifications
Note: Minimum applicable loads are indicated by N standard refer-
ence values. This value represents the failure rate at a 60%
60) reliability level (JIS C5003).
The equation λ60=0.5 x 10-6 / operations indicates that a failure
rate of less than 1/2,000,000 operations can be expected at a
reliability level of 60%
Engineering Data
Structure
Mounting
All switches may be panel mounted using M3 mounting screws with
plane washers or spring washers to securely mount the switch.
Tighten the screws to a torque of 0.39 to 0.59 N·m.
Rated Voltage D2VW-5 D2VW-01
125 VAC
250 VAC
3A
3A
0.1 A
---
30 VDC - - - 0.1 A
Rated Voltage D2VW-5 D2VW-01
125 VAC
250 VAC
---
3A
0.1 A
---
Item D2VW-5 D2VW-01
Specification Rivet Crossbar
Material Silver alloy Gold alloy
Gap (standard value) 0.5 mm
Inrush current NC: 15 A max.
NO: 15 A max. ---
Minimum applicable load
(see note)
160 mA at 5 VDC 1 mA at 5 VDC
NC (red)
NO (blue)
COM (black)
SPDT
NC (red)
COM (black)
SPST-NC
NO (blue)
COM (black)
SPST-NO
Note: Colors in parentheses indicate lead wire colors.
Two, 3.1-dia. mounting holes or
M3 screw holes
22.2 ± 0.1
10.3 ± 0.1
4Sealed Snap Action Switch D2VW
Dimensions
Terminals
Note: 1. Unless otherwise specified, all units are in millimeters and a tolerance of ±0.4 mm applies to all dimensions
2. The pin plunger model is shown here as a typical example for both the solder/quick connect terminals and the molded lead wire versions.
Dimensions and Operating Characteristics
Note: 1. Unless otherwise specified, all units are in millimeters and a tolerance of ±0.4 mm applies to all dimensions
2. Omitted dimensions are the same as pin plunger type.
3. The operating characteristics are for operation in the A direction( )
Solder/Quick Connect Terminals
t=0.5
Three, solder terminals
1.3 dia. hole2.4 dia. hole
8.4
5.2
1.2
4.810.3
2.5
5.2
5.2
41.4
33
22.2±0.1
0.5
2.8
Molded Lead Wires
* UL/CSA approved models have AWG20 UL1015 approved wiring.
AV 0.75f Lead wire (red)*
AV 0.75f Lead wire (blue)*
AV 0.75f Lead wire (black)*
33
2.8
(5) 10.3
22.2±0.1
L
300 mm type 1,000 mm type
L300 ±10 mm 1,000 ±30 mm
Pin Plunger Models
D2VW-01-1HS
D2VW-5-1HS
t=0.5
Three, solder terminals
1.3 dia. hole2.4 dia. hole
8.4
5.2
1.2
4.810.3
20.2±0.25
2.5 dia.
2.5
5.2
5.2
41.4
33
22.2±0.1
10.3±0.1
15.9
OP
PT
2.8
3.1+0.13
–0.03
3.1+0.13
–0.03 dia. holes
0.5
3.2±0.1 dia.
2.8
A
OF max 200 gf
RF min. 30 gf
PT max. 1.2 mm
OT min. 1.0 mm
MD max. 0.4 mm
OP 14.7 ±0.4 mm
Short Hinge Lever Models
D2VW-01L1A-1MS
D2VW-5L1A-1MS
PT
OP
10.3
54.3
15.9
*Stainless-steel lever
t=0.5*
24.3±0.8
A
OF max 200 gf
RF min. 20 gf
PT max. 1.6 mm
OT min. 0.8 mm
MD max. 0.5 mm
OP 15.2 ±0.5 mm
Hinge Lever Models
D2VW-01L1-1MS
D2VW-5L1-1MS
PT
OP
10.3
4.3
*Stainless-steel lever
5
t=0.5*
35.6±0.8
15.9
A
OF max 120 gf
RF min. 15 gf
PT max. 4.0 mm
OT min. 1.6 mm
MD max. 0.8 mm
OP 15.2 ±1.2 mm
Sealed Snap Action Switch D2VW 5
Note: 1. Unless otherwise specified, all units are in millimeters and a tolerance of ±0.4 mm applies to all dimensions
2. Omitted dimensions are the same as pin plunger type.
3. The operating characteristics are for operation in the A direction( )
Long Hinge Lever Models
D2VW-01L1B-1MS
D2VW-5L1B-1MS
PT
OP
10.3
4.3
15.9
*Stainless-steel lever
5
t=0.5*
59.4±0.8
AOF max 60 gf
RF min. 5gf
PT max. 9.0 mm
OT min. 3.2 mm
MD max. 2.0 mm
OP 15.2 ±2.6 mm
Simulated Roller Lever Models
D2VW-01L3-1MS
D2VW-5L3-1MS 54.3
10.3
3.5R t=0.5*
PT
OP
32.6±0.8
*Stainless-steel lever
15.9
t=0.5*
A
OF max 120 gf
RF min. 15 gf
PT max. 4.0 mm
OT min. 1.6 mm
MD max. 0.8 mm
OP 18.7 ±1.2 mm
Short Hinge Roller Lever Models
D2VW-01L2A-1MS
D2VW-5L2A-1MS
24.3±0.8
20.1±0.8
t=0.5*
4.8 dia. 4.8 **
PT
7.2
10.3
15.9
OP
*Stainless-steel lever
**Oil-less polyacetal resin roller
5
A
OF max 230 gf
RF min. 20 gf
PT max. 1.6 mm
OT min. 0.8 mm
MD max. 0.5 mm
OP 20.7 ±0.6 mm
Hinge Roller Lever Models
D2VW-01L2-1MS
D2VW-5L2-1MS 4.8 dia. 4.8 **
7.2
10.3
5
*Stainless-steel lever
**Oil-less polyacetal resin roller
t=0.5*
34±0.8
PT
OP
15.9
AOF max 120 gf
RF min. 15 gf
PT max. 4.0 mm
OT min. 1.6 mm
MD max. 0.8 mm
OP 20.7 ±1.2 mm
6Sealed Snap Action Switch D2VW
Precautions
Be sure to read the precautions and information common to all Snap Action and Detection Switches, contained in the Technical User’s Guide,
“Snap Action Switches, Technical Information” for correct use.
Correct Use
Operations
Make sure that the switching object is perfectly separated from the
actuator when the switch is not operated and the actuator is pressed
appropriately by the switching object when the switch is operated.
The switch should be set so that its stroke will be within the rated OT
when the switch is operated.
With the pin plunger models, set the switch so that the plunger can
be actuated from directly above. Since the plunger is covered with a
rubber cap, applying a force from lateral directions may cause
damage to the plunger or reduction in the sealing capability.
Handling
Handle the switch carefully so as not to break the sealing rubber of
the plunger.
Using Microloads
Using a model for ordinary loads to switch microloads may result in
faulty operation. Instead, use the models that are designed for
microloads and that operate in the following range;
However, even when using microload models within the operating
range shown above, if inrush current or inductive voltage spikes
occur when the contact is opened or closed, then contact wear may
increase and so decrease the service life. Therefore, insert a contact
protection circuit where necessary.
Soldering - Connecting to Solder Terminals
When soldering the lead wire to the terminal, first insert the lead wire
conductor through the terminal hole and then conduct soldering.
Complete the soldering at the iron tip temperature between 350 to
400 C within 3 seconds, and do not apply any external force for 1
minute after soldering. Soldering at an excessively high temperature
or soldering for more than 3 seconds may deteriorate the character-
istics of the switch.
Mounting
Use M3 mounting screws with plane washers or spring washers to
securely mount the switch.
Tighten the screws to a torque of 0.39 to 0.59 N·m(4to6kgf·cm)
Cautions
Degree of Protection
Do not use the Switch underwater.
The switch was tested and found to satisfy the conditions necessary
to meet the following standards. However, the test only checks for
water intrusion after immersion for a specified time period, not for
switching and operation underwater.
The switch is tested and conforms to JIS C0920 (Degrees of protec-
tion provided by enclosures of electrical apparatus) and IEC60529
(Degrees of protection provided by enclosures).
Note: The object to be tested is submerged at a depth of 1 meter for
30 minutes, then checked for water intrusion.
Protection Against Chemicals
Prevent the switch from coming into contact with oil and chemicals.
Otherwise, damage to or deterioration of the switch materials may
occur.
Correct
Incorrect
Incorrect
Operating range
for micro load
models D2VW-01
Operating
range for
general-load
models
D2VW-05
Current (mA)
Voltage (V)
Inoperable
range
30
24
12
5
0
110 100 1,000
0.16mA 100mA
100mA 160mA
26mA
1mA
Sealed Snap Action Switch D2VW 7
MEMO
8Sealed Snap Action Switch D2VW
OMRON ON-LINE
Global - http://www.omron.com
USA - http://www.components.omron.com
Cat. No. C095-E-05 Printed in USA
OMRON ELECTRONIC
COMPONENTS LLC
847-882-2288
09/14 (11/10) Specifications subject to change without notice
All sales are subject to Omron Electronic Components LLC standard terms and conditions of sale, which
can be found at http://www.components.omron.com/components/web/webfiles.nsf/sales_terms.html
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.