EMC Filters Series/Type: B84113C The following products presented in this data sheet are being withdrawn. Ordering Code Substitute Product B84113C0000L110 B84113C0000L060 B84113C0000L030 Date of Withdrawal 2013-04-12 2013-04-12 2013-04-12 Deadline Last Orders 2013-07-31 2013-07-31 2013-07-31 Last Shipments 2013-10-31 2013-10-31 2013-10-31 (c) EPCOS AG 2015. Reproduction, publication and dissemination of this publication, enclosures hereto and the information contained therein without EPCOS' prior express consent is prohibited. EPCOS AG is a TDK Group Company. Ordering Code B84113C0000K030 Substitute Product Date of Withdrawal 2013-04-12 Deadline Last Orders 2013-07-31 Last Shipments 2013-10-31 For further information please contact your nearest EPCOS sales office, which will also support you in selecting a suitable substitute. The addresses of our worldwide sales network are presented at www.epcos.com/sales. 2-line filters B84113C SIFI-C for very high insertion loss Power line filters for 1-phase systems Rated voltage 250 V DC/AC, 50/60 Hz Rated current 3 to 10 A Alternative version Series B84113H (SIFI-H) offers a low-cost solution Construction 2-line filters Metal case Polyurethane potting (UL 94 V-0) Features Compact design Optimized leakage current Cost-optimized construction Also for assembly on top-hat rails ENEC10, UL and CSA approval Applications Switch-mode power supplies in - industrial electronics - telecommunications - data systems - medical equipment DC applications Case styles and terminal styles Case style A Tab connectors on face ends, lateral fixing lugs. Particularly suitable for mounting on a shielding wall. Case style B Tab connectors on face ends, fixing lugs on face ends. Case style K IEC connector as per IEC 60320 C 14 on line side, tab connectors on load side, mounting holes with metric thread. Case style L Litz wires on face ends, fixing lugs on face ends Marking Marking on component: Manufacturer's logo, ordering code, rated voltage, rated current, rated temperature, climatic category, date code Minimum marking on packaging: Manufacturer's logo, ordering code Please read Cautions and warnings and Important notes at the end of this document. 2 01/06 2-line filters B84113C SIFI-C for very high insertion loss Circuit diagram LINE LOAD L L' N N' SSB0257-G Technical data and measuring conditions Rated voltage VR 250 V DC/AC, 50/60 Hz Rated current IR Referred to 40 C ambient temperature Test voltage Vtest 1414 V DC, 2 s (line/line) 2700 V DC, 2 s (lines/case) Leakage current lleak At 230 V AC, 50 Hz Climatic category (IEC 60068-1) 25/085/21 (-25 C/+85 C/21 days damp heat test) Approvals EN 133200, UL 1283, CSA C22.2 No.8 Characteristics and ordering codes IR CR A LR Ileak mH mA Case Approx. Ordering code style weight g Mounting plate for top-hat rail (ordering code) VR = 250 V DC/AC, 50/60 Hz 3 2 x 0.47 F (X2) + 2 x 4700 pF (Y2) 4x 4.7 < 0.5 A B K L 210 210 270 210 B84113C0000A030 B84113C0000B030 B84113C0000K030 B84113C0000L030 6 2 x 0.47 F (X2) + 2 x 4700 pF (Y2) 4x 4.7 < 0.5 A B L 510 510 510 B84113C0000A060 -- B84113C0000B060 C62122A0132B095 B84113C0000L060 -- 10 2 x 0.47 F (X2) + 2 x 4700 pF (Y2) 4x 3.6 < 0.5 A B L 690 690 690 B84113C0000A110 -- B84113C0000B110 C62122A0132B095 B84113C0000L110 -- Please read Cautions and warnings and Important notes at the end of this document. 3 01/06 -- C62122A0132B092 -- -- 2-line filters B84113C SIFI-C for very high insertion loss Case styles and dimensions Case style IR Dimensions (mm) b2 b3 b4 b1 l1 l2 l3 l4 h1 h2 Litz mm2 Style 1015 50.8 50.8 50.8 50.8 70 -- -- -- 63.5 63.5 63.5 63.5 -- 74.7 -- 74.7 -- 84.5 -- 84.5 89.5 89.5 -- -- 38.1 38.1 38 38.1 28 28 -- -- -- -- -- 0.82 -- -- -- AWG18 -- See dimensional drawing See dimensional drawing 133 142.9 153 -- 44.5 -- 0.82 AWG18 -- See dimensional drawing See dimensional drawing 133 142.9 153 -- 44.5 -- 1.35 AWG16 A A B K L 3 3 3 3 A B L 6 6 6 A B L 10 10 10 31.5 31.5 -- -- 50.8 -- 50.8 -- 60.4 -- -- -- -- -- Case style A Case style A 3 A (B84113C0000A030) 6 and 10 A (B84113C0000A060, A110) 44.5 0.8 h2 0.8 h1 b2 281 50.8 31.5 b1 Tab connector A6.3 x 0.8 Tab connector A6.3 x 0.8 o4.7 159 133 101.6 4 1 o4.7 b3 b4 SSB0531-6-E 60.4 70 Please read Cautions and warnings and Important notes at the end of this document. 4 01/06 SSB0261-9-E 2-line filters B84113C SIFI-C for very high insertion loss Case style B Case style B 3 A (B84113C0000B030) 6 and 10 A (B84113C0000B060, B110) 44.5 0.8 h1 0.8 159 153 142.9 3 2 1 Tab connector A6.3 x 0.8 133 h2 Tab connector A6.3 x 0.8 o4.7 4 281 50.8 31.5 b1 b2 SSB0528-L-E o4.7 Case style K SSB0262-H-E Case style L b1 16 0.8 h1 161 M4 h1 3.41 101 41 b1 40 105+15 o4.7 1 2 3 1 13 BN BU 6 _2 Tab connector A6.3 x 0.8 GNYE 6 _2 20.5 3 19 31.5 28.5 400.2 BU SSB0255-Z-E SSB0529-U-E Please read Cautions and warnings and Important notes at the end of this document. BN 105+15 Panel cutout o4.5 5 01/06 2-line filters B84113C SIFI-C for very high insertion loss Insertion loss (typical values at Z = 50 ) unsymmetrical, adjacent branches terminated common mode, all branches in parallel (asymmetrical) differential mode (symmetrical) Filters for 3 A Filters for 6 A 100 dB B84113C0000*030 SSB0258-P 100 dB B84113C0000*060 SSB0259-X 80 80 60 60 40 40 20 20 0 10 4 10 5 10 6 10 7 0 10 4 Hz 10 8 f Filters for 10 A SSB0260-1 100 dB B84113C0000*110 80 60 40 20 0 10 4 10 5 10 6 10 7 Hz 10 8 f Please read Cautions and warnings and Important notes at the end of this document. 6 01/06 10 5 10 6 10 7 Hz 10 8 f EMC filters Cautions and warnings Important information Please read all safety and warning notes carefully before installing the EMC filter and putting it into operation (see ). The same applies to the warning signs on the filter. Please ensure that the signs are not removed nor their legibility impaired by external influences. Death, serious bodily injury and substantial material damage to equipment may occur if the appro priate safety measures are not carried out or the warnings in the text are not observed. Using according to the terms The EMC filters may be used only for their intended application within the specified values in low voltage networks in compliance with the instructions given in the data sheets and the data book. The conditions at the place of application must comply with all specifications for the filter used. Warnings It shall be ensured that only qualified persons (electricity specialists) are engaged on work such as planning, assembly, installation, operation, repair and maintenance. They must be provided with the corresponding documentation. Danger of electric shock. EMC filters contain components that store an electric charge. Danger ous voltages can continue to exist at the filter terminals for longer than five minutes even after the power has been switched off. The protective earth connections shall be the first to be made when the EMC filter is installed and the last to be disconnected. Depending on the magnitude of the leakage currents, the particular specifications for making the protective-earth connection must be observed. Impermissible overloading of the EMC filter, such as impermissible voltages at higher frequen cies that may cause resonances etc. can lead to destruction of the filter housing. EMC filters must be protected in the application against impermissible exceeding of the rated currents by suitable overcurrent protective. 7 01/06 EMC filters Important notes The following applies to all products named in this publication: 1. Some parts of this publication contain statements about the suitability of our products for certain areas of application. These statements are based on our knowledge of typical requirements that are often placed on our products in the areas of application concerned. We nevertheless expressly point out that such statements cannot be regarded as binding statements about the suitability of our products for a particular customer application. As a rule, EPCOS is either unfamiliar with individual customer applications or less familiar with them than the customers themselves. For these reasons, it is always ultimately incumbent on the customer to check and decide whether an EPCOS product with the properties described in the product specification is suitable for use in a particular customer application. 2. We also point out that in individual cases, a malfunction of passive electronic components or failure before the end of their usual service life cannot be completely ruled out in the current state of the art, even if they are operated as specified. In customer applications requiring a very high level of operational safety and especially in customer applications in which the malfunction or failure of a passive electronic component could endanger human life or health (e.g. in accident prevention or life-saving systems), it must therefore be ensured by means of suitable design of the customer application or other action taken by the customer (e.g. installation of protective circuitry or redundancy) that no injury or damage is sustained by third parties in the event of malfunction or failure of a passive electronic component. 3. The warnings, cautions and product-specific notes must be observed. 4. In order to satisfy certain technical requirements, some of the products described in this publication may contain substances subject to restrictions in certain jurisdictions (e.g. because they are classed as "hazardous"). Useful information on this will be found in our Material Data Sheets on the Internet (www.epcos.com/material). Should you have any more detailed questions, please contact our sales offices. 5. We constantly strive to improve our products. Consequently, the products described in this publication may change from time to time. The same is true of the corresponding product specifications. Please check therefore to what extent product descriptions and specifications contained in this publication are still applicable before or when you place an order. We also reserve the right to discontinue production and delivery of products. Consequently, we cannot guarantee that all products named in this publication will always be available. 6. Unless otherwise agreed in individual contracts, all orders are subject to the current version of the "General Terms of Delivery for Products and Services in the Electrical Industry" published by the German Electrical and Electronics Industry Association (ZVEI). 7. The trade names EPCOS, EPCOS-Jones, Baoke, CeraDiode, CSSP, MLSC, PhaseCap, PhaseMod, SIFI, SIKOREL, SilverCap, SIMID, SIOV, SIP5D, SIP5K, UltraCap, WindCap are trademarks registered or pending in Europe and in other countries. Further information will be found on the Internet at www.epcos.com/trademarks. 8 01/06 Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: EPCOS: B84113C0000L060