MODEL YW512A YW515A
MAX OUTPUT WATTAGE[W] 5.28 5.10
DC OUTPUT
*1
t12V 0.22A or +24V 0.22A t15V 0.17A or +30V 0.17A
SPECIFICATIONS
MODEL YW512A YW515A
INPUT
VOLTAGE[V] AC85 - 132 1for DC110 - 170
CURRENT[A]
ACIN 100V
0.15typ (Io=100%)
FREQUENCY[Hz] 47 - 440 or DC
EFFICIENCY[%]
ACIN 100V
70typ (Io=100%)
INRUSH CURRENT[A]
ACIN 100V
15typ (Io=100%)
OUTPUT
VOLTAGE[V] t12 (+24)t15 (+30)
CURRENT[A] 0.22 0.17
LINE REGULATION[mV] 60max 75max
LOAD REGULATION[mV] 600max 750max
RIPPLE[mVp-p]
*2
120max 120max
RIPPLE NOISE[mVp-p]
*2
150max 150max
TEMPERATURE REGULATION[mV]
0to+55
C
150max 180max
START-UP TIME[ms] 200max (ACIN 85V,Io=100%)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
Fixed
OUTPUT VOLTAGE SETTING[%]
t5max (Rated input/output,Ta=25C)
HOLD-UP TIME[ms] 10typ (ACIN 85V,Io=100%)
PROTECTION
CIRCUIT
OVERCURRENT PROTECTION
Works over 105% of rating and recovers automatically
ISOLATION
INPUT-FG,OUTPUT AC2,000V 1minute,Cutoff current = 10mA,DC500V 50MWmin (At Room Temperature)
OUTPUT-FG AC500V 1minute,Cutoff current = 100mA,DC500V 50MWmin (At Room Temperature)
ENVIRONMENT
OPERATING TEMP.,HUMID.AND ALTITUDE
-10 to +70C,20 - 95%RH (Non condensing)(
Refer to DERATING CURVE), 3,000m (10,000feet)max
STORAGE TEMP.,HUMID.AND ALTITUDE
-20 to +75C,20 - 95%RH (Non condensing), 9,000m (30,000feet)max
VIBRATION 10 - 55Hz,98.0m/s2(10G), 3minutes period,30minutes each along X,Y and Z axis
IMPACT 490.3m/s2(50G), 11ms,once each X,Y and Z axis
SAFETY AND
NOISE
REGULATIONS
AGENCY APPROVALS UL60950-1,C-UL
CONDUCTED NOISE Complies with FCC-B