Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 1119A Triad - 600V Tray Cable For more Information please call 1-800-Belden1 General Description: 16 AWG triads stranded (7x24) bare copper conductors, twisted triads, overall Beldfoil(R) shield (100% coverage), PVC/Nylon insulation, PVC jacket. Physical Characteristics (Overall) Conductor AWG: # Triads AWG Stranding Conductor Material 1 16 7x24 BC - Bare Copper Total Number of Conductors: 3 Insulation Insulation Material: Insulation Material PVC/Nylon - Polyvinyl Chloride/Nylon Inner Shield Inner Shield Material: Inner Shield Trade Name Type Inner Shield Material Beldfoil(R) Coverage (%) Tape Aluminum Foil-Polyester Tape 100 Inner Shield Drain Wire AWG: AWG 18 Inner Shield Drain Wire Stranding: 7x26 Inner Shield Drain Wire Conductor Material: TC - Tinned Copper Inner Shield Color Code Chart: Number Color 1 Black & Red & Blue Outer Shield Outer Shield Material: Outer Shield Material Unshielded Outer Jacket Outer Jacket Material: Outer Jacket Material Nom. Wall Thickness (mm) PVC - Polyvinyl Chloride 1.1938 Outer Jacket Ripcord: Yes Overall Cable Overall Nominal Diameter: 7.874 mm Mechanical Characteristics (Overall) Wet Temperature Range: -30C To +75C Dry Temperature Range: -30C To +90C Bulk Cable Weight: 99.709 Kg/Km Page 1 of 3 08-21-2013 Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 1119A Triad - 600V Tray Cable Max. Recommended Pulling Tension: 573.818 N Min. Bend Radius/Minor Axis: 78.740 mm Applicable Specifications and Agency Compliance (Overall) Applicable Standards & Environmental Programs NEC/(UL) Specification: TC, NPLF, UL 1277 EU Directive 2011/65/EU (ROHS II): Yes EU CE Mark: Yes EU Directive 2000/53/EC (ELV): Yes EU Directive 2002/95/EC (RoHS): Yes EU RoHS Compliance Date (mm/dd/yyyy): 04/01/2005 EU Directive 2002/96/EC (WEEE): Yes EU Directive 2003/11/EC (BFR): Yes CA Prop 65 (CJ for Wire & Cable): Yes MII Order #39 (China RoHS): Yes Other Specification: ICEA S-73-532, S-61-402 Flame Test UL Flame Test: UL1685 UL Loading CSA Flame Test: FT4 IEEE Flame Test: 1202 ICEA Flame Test: T-29-520 Suitability Suitability - Indoor: Yes Suitability - Outdoor: Yes Suitability - Burial: Yes Sunlight Resistance: Yes Plenum/Non-Plenum Plenum (Y/N): No Electrical Characteristics (Overall) Nom. Conductor DC Resistance: DCR @ 20C (Ohm/km) 12.0413 Nominal Outer Shield DC Resistance: DCR @ 20C (Ohm/km) 16.3722 Max. Operating Voltage - UL: Voltage 600 V RMS (NEC Type TC) 150 V RMS (NPLF) Notes (Overall) Notes: Alternate color coding available upon request. Put Ups and Colors: Item # Putup Ship Weight Color Notes Item Desc 1119A 0101000 305 MT 30.844 KG BLACK CZ 3 #16 PVC/NYL FS PVC Page 2 of 3 08-21-2013 Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 1119A Triad - 600V Tray Cable 1119A 01010000 3,048 MT 317.516 KG BLACK CZ 3 #16 PVC/NYL FS PVC 1119A 010500 152 MT 15.876 KG BLACK CZ 3 #16 PVC/NYL FS PVC Notes: C = CRATE REEL PUT-UP. Z = FINAL PUT-UP LENGTH MAY VARY (+ OR -) 10% FOR SPOOLS OR REELS AND(+ OR -) 5% FOR UNREEL CARTONS FROM LENGTH SHOWN. Revision Number: 1 Revision Date: 12-19-2012 (c) 2013 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale. Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the compliance date may be in stock at Belden facilities and in our Distributor's inventory. The information provided in this Product Disclosure, and the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Belden's knowledge, information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product. Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 73/23/EEC), as amended by directive 93/68/EEC. Page 3 of 3 08-21-2013