Walsin Technology Corporation
Page 6 of 7 WR04X Version 13 Nov.-2006
TEST AND REQUIREMENTS(JIS C 5201-1 : 1998)
REQUIREMENT
TEST PROCEDURE / TEST METHOD Resistor 0Ω
DC resistance
Clause 4.5
DC resistance values measured at the test voltages specified below :
<10Ω@0.1V, <100Ω@0.3V, <1KΩ@1.0V,
<10KΩ@3V, <100KΩ@10V, <1MΩ@25V, <10MΩ@30V
Within the specified tolerance <50mΩ
Temperature
Coefficient of
Resistance(T.C.R)
Clause 4.8
Natural resistance change per change in degree centigrade.
()
6
121
12 10×
−
−
ttR RR (ppm/°C) t1 : 20°C+5°C-1°C
R1 : Resistance at reference temperature
R2 : Resistance at test temperature
Refer to
“QUICK REFERENCE DATA”
N/a
Short time overload
(S.T.O.L)
Clause 4.13
Permanent resistance change after a 5second application of a voltage
2.5 times RCWV or the maximum overload voltage specified in the
above list, whichever is less.
∆R/R max. ±(2%+0.10Ω) <50mΩ
Resistance to
soldering heat(R.S.H)
Clause 4.18
Un-mounted chips completely immersed for 10±1second in a solder
bath at 270℃±5ºC ΔR/R max. ±(1%+0.05Ω)
no visible damage <50mΩ
Solderability
Clause 4.17
Un-mounted chips completely immersed for 2±0.5second in a solder
bath at 235℃±5℃ 95% coverage min., good tinning and no
visible damage
Leach Test
Clause 4.18
Un-mounted chips completely immersed for 60±1second in a solder
bath at 260℃±5℃ Ditto
Temperature cycling
Clause 4.19
30 minutes at -55°C±3°C, 2~3 minutes at 20°C+5°C-1°C, 30 minutes at
+155°C±3°C, 2~3 minutes at 20°C+5°C-1°C, total 5 continuous cycles ∆R/R max. ±(1%+0.05Ω) < 50mΩ
Damp Heat
(Load life in humidity)
Clause 4.24
1000+48/-0 hours; 1.5hours ON, 0.5hours OFF at RCWV in a humidity
chamber controlled 40±2°C, 90~95% RH
10Ω≤R<1MΩ :
∆R/R max. ±(3%+0.10Ω)
R<10Ω, R≥1MΩ :
∆R/R max. ±(5%+0.10Ω)
< 50mΩ
Load Life (Endurance)
Clause 4.25
1000+48/-0 hours; loaded with Pn or Vmax; 1.5 hours ON, 0.5 hours OFF Ditto.
Bending strength
Clause 4.33
Resistors mounted on a 90mm glass epoxy resin PCB(FR4), bending
once 5mm for 10sec.
No visual damaged,
∆R/R max. ±(1%+0.05Ω) < 50mΩ
Adhesion
Clause 4.32
Pressurizing force: 5N, Test time: 10±1sec. No remarkable damage or removal of the
terminations