DC/DC Converter A05_XT-1WR3 Series FEATURES 1W isolated DC-DC converter Fixed input voltage and unregulated dual output Continuous short-circuit protection No-load input current as low as 5mA Operating ambient temperature range: -40 to +105 High efficiency up to 85% Compact SMD package I/O isolation test voltage 1.5k VDC Industry standard pin-out CB Patent Protection RoHS IEC62368, UL62368, EN62368 approved A05_XT-1WR3 series are specially designed for applications where two isolated voltage is required in a distributed power supply system. They are suitable for: pure digital circuits, low frequency analog circuits, relay-driven circuits and data switching circuits. Selection Guide Input Voltage(VDC) Certification Part No. A0509XT-1WR3 A0515XT-1WR3 Capacitive Load(F)* Max./Min. Min./Typ. Max. 5 100/10 78/82 1200 Voltage ( Range ) (VDC) 5 (4.5-5.5) A0512XT-1WR3 Full Load Efficiency(%) Current(mA) A0505XT-1WR3 UL/CE/CB Output Nominal A0524XT-1WR3 9 56/6 79/83 470 12 42/5 79/83 220 15 34/4 79/83 220 24 21/3 81/85 100 Note: * The specified maximum capacitive load for positive and negative output is identical. Input Specifications Item Operating Conditions Input Current (full load / no-load) 5VDC input Min. Max. Unit 5VDC output -- 244/5 257/10 9VDC/12VDC output -- 241/12 254/20 15VDC/24VDC output -- 241/18 254/30 -- 15 -- mA -- 9 VDC Reflected Ripple Current* Surge Voltage (1sec. max.) Typ. 5VDC input -0.7 Input Filter mA Capacitance filter Hot Plug Unavailable Note: * Refer to DC-DC Converter Application Notes for detailed description of reflected ripple current test method. Output Specifications Item Operating Conditions Min. Voltage Accuracy Linear Regulation Load Regulation Typ. Max. Unit See output regulation curve(Fig. 1) Input voltage change: 1% 10%-100% load Ripple & Noise* 20MHz bandwidth Temperature Coefficient Full load -- -- 1.2 5VDC output -- 10 15 9VDC output -- 8 10 12VDC output -- 7 10 15VDC output -- 6 10 24VDC output -- 5 10 Other output -- 30 75 24VDC output -- 50 100 -- 0.02 -- 2019.10.18-A/6 % % mVp-p %/ Page 1 of 5 MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation DC/DC Converter A05_XT-1WR3 Series Short-circuit Protection Continuous, self-recovery Note: * The "parallel cable" method is used for Ripple and Noise test, please refer to DC-DC Converter Application Notes for specific information. General Specifications Item Operating Conditions Input-output Electric Strength Test for 1 minute with a leakage current of 1mA max. Isolation Insulation Resistance Input-output resistance at 500VDC Isolation Capacitance Input-output capacitance at 100kHz/0.1V Operating Temperature Derating when operating temperature100, (see Fig. 2) Storage Temperature Case Temperature Rise Ta=25 Storage Humidity Non-condensing Min. Typ. Max. Unit 1500 -- -- VDC 1000 -- -- M -- 20 -- pF -40 -- 105 -55 -- 125 -- 15 -- -- -- 95 %RH Peak temp.245, maximum duration time60s over 217. Reflow Soldering Temperature* Switching Frequency Full load, nominal input voltage MTBF MIL-HDBK-217F@25 Moisture Sensitivity Level (MSL) IPC/JEDEC J-STD-020D.1 -- 270 3500 -- -- KHz -- K hours Level 1 Note: * For actual application, please refer to IPC/JEDEC J-STD-020D.1. Mechanical Specifications Case Material Black plastic; flame-retardant and heat-resistant (UL94 V-0) Dimensions 15.24 x 11.40 x 7.25 mm Weight 1.4g(Typ.) Cooling methods Free air convection Electromagnetic Compatibility (EMC) Emissions Immunity CE CISPR32/EN55032 CLASS B (see Fig. 5 for recommended circuit) RE CISPR32/EN55032 CLASS B (see Fig. 5 for recommended circuit) ESD IEC/EN61000-4-2 Air 8kV , Contact 4kV perf. Criteria B Typical Characteristic Curves Output P ower Percent(%) Temperature Derating Cur ve Fig. 1 120 100 80 60 Safe Ope rating Area 40 20 0 -40 40 71 100 105 0 Ambient Temp.( ) Fig. 2 2019.10.18-A/6 Page 2 of 5 MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation DC/DC Converter A05_XT-1WR3 Series Design Reference 1. Typical application circuit Input and/or output ripple can be further reduced, by connecting a filter capacitor from the input and/or output terminals to ground as shown in Fig. 3. Choosing suitable filter capacitor values is very important for a smooth operation of the modules, particularly to avoid start-up problems caused by capacitor values that are too high. For recommended input and output capacitor values refer to Table 1. The simplest device for output voltage regulation, over-voltage and over-current protection is a linear voltage regulator with overheat protection that is connected to the input or output end in series (see Fig. 4). Vin GND Cin +Vo Cout DC DC Vin 0V Cout REG GND -Vo REG DC DC 0V REG Fig.3 +Vo -Vo Fig.4 Recommended capacitive load value table (Table 1) Vin(VDC) Cin(F) 5 Vo (VDC) Cout(F) 5 4.7 4.7 9 2.2 12 1 15/24 1 2. EMC (CLASS B) compliance circuit Fig. 5 EMC recommended circuit value table (Table 2) Output voltage(VDC) Input voltage 5VDC EMI 5/9 12/15/24 C1/C2 4.7F /25V 4.7F /25V CY -- 1nF/2KVDC HEC C1206X102K202T JOHANSON 202R18W102KV4E C3 LDM Refer to the Cout in table 1 6.8H 6.8H Note: In the case of actual use, the requirements for EMI are high, it is subject to CY. 3.For additional information please refer to DC-DC converter application notes on www.mornsun-power.com. 2019.10.18-A/6 Page 3 of 5 MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation DC/DC Converter A05_XT-1WR3 Series Dimensions and Recommended Layout 2019.10.18-A/6 Page 4 of 5 MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation DC/DC Converter A05_XT-1WR3 Series Notes: 1. 2. 3. 4. 5. 6. 7. 8. For additional information on Product Packaging please refer to www.mornsun-power.com. Tube Packaging bag number: 58210023, Roll Packaging bag number: 58210034; If the product is not operated within the required load range, the product performance cannot be guaranteed to comply with all parameters in the datasheet; The maximum capacitive load offered were tested at input voltage range and full load; Unless otherwise specified, parameters in this datasheet were measured under the conditions of Ta=25, humidity<75%RH with nominal input voltage and rated output load; All index testing methods in this datasheet are based on our company corporate standards; We can provide product customization service, please contact our technicians directly for specific information; Products are related to laws and regulations: see "Features" and "EMC"; Our products shall be classified according to ISO14001 and related environmental laws and regulations, and shall be handled by qualified units. MORNSUN Guangzhou Science & Technology Co., Ltd. Address: No. 5, Kehui St. 1, Kehui development center,Science Ave., Guangzhou Science City, Huangpu District, Guangzhou,P.R.China Tel: 86-20-38601850 Fax: 86-20-38601272 E-mail:info@mornsun.cn www.mornsun-power.com 2019.10.18-A/6 Page 5 of 5 MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation