Fluke 725Ex Intrinsically Safe Multifunction Process Calibrator Simply powerful intrinsic safe calibration tool Technical Data The new Fluke 725Ex Intrinsically Safe Multifunction Process Calibrator is powerful yet easy-to-use. Combined with one of the (eight) new Fluke 700PEx Pressure Modules, the 725Ex is able to calibrate almost any process instrument likely to need service in an area where explosive gasses may be present. The Fluke 725Ex Intrinsically Safe Calibrator is a powerful, new intrinsically safe, multifunction calibration solution that offers: * * * * * * ATEX II 1G EEx ia IIB 171 C KEMA 04ATEX 1303X I.S. Class I, Division 1 Groups B-D, 171 C compliance Measure volts dc, mA, RTDs, thermocouples, frequency and ohms Source or simulate volts dc, mA, RTDs, thermocouples, frequency and ohms Two channel simultaneous source and measure capability for calibration of transmitters Power transmitters with internal loop supply * * * * * * Store frequently-used test setups for later use Pressure measurement to 3,000 psi/200 bar using any of the 8 intrinsically safe Fluke 700PEx Pressure Modules Pressure switch test function (requires 700PEx module) Compact size and weight Simple, push-button user interface Rugged and reliable, for field use The optional Fluke 700PEx Pressure Modules are ATEX-certified Ex II 1 G EEx ia IIC T4. They are also certified by CSA I.S. Class 1, Division 1 areas Group A-D per NEC-500. Simultaneous Function Capability Channel A Channel B 24.000 mA dc M M or S 24.000 mA dc with 24 V loop supply M 100.00 mV dc M or S 30.000 V dc measure M 20.000 V dc measure 10.000 V dc source M or S 15 to 3200 Ohms M or S Thermocouple J, K, T, E, R, S, B, L, U, N M or S RTD Ni120; Pt100 (392); Pt100 (JIS); Pt100, 200, 500, 1000 (385) M or S Pressure (requires Fluke 700Pxx modules) Frequency; Squarewave, 1 CPM to 10 kHz; fixed amplitude 5 V p-p M = Measure S = Source/Simulate M M used as S M or S Ordering information Model Fluke-725Ex Multifunction Process Calibrator Included accessories Protective red holster, TL75 test leads, AC70A test clips, one pair of stackable test leads, CD users manuals (English, French, German, Spanish, Italian, Dutch, Norwegian, Danish, Swedish, Finnish, Portuguese, Korean, Chinese, Japanese), Fluke 725Ex CCD control drawing, Statement of Quality Assurance Practices I.S. Class I Div 1 Groups B-D 171 C AEx ia IIB 171 C II 1 G EEx ia IIB 171 C KEMA 04 ATEX 1303X Ta = -10 C to +55 C Specifications Summary specifications (18 C to 28 C for one year) Function Measure or Source Voltage mA mV (TC terminals) Resistance Frequency Loop supply Range Resolution Accuracy Notes 0 to 100 mV 0 to 10 V (source) 0 to 30 V (measure) 0 to 24 -10.00 mV to +75.00 mV 15 to 3200 2.0 to 1000.0 CPM 1 to 1000 Hz 1.0 to 10.0 kHz < = 12 V 0.01 mV 0.01 V 0.01 V 0.001 mA .01 mV 0.01 to 0.1 0.1 CPM 1 Hz 0.1 kHz N/A .02 % Rdg + 2 LSD Max load, 1 mA .02 % Rdg + 2 LSD .025 % or range + 1 LSD 0.10 W to 1.0 W .05 % .05 % .25 % 10 % Max load, 500 @ 20 mA For frequency source, waveform is 5 V p-p squarewave, -0.1 V offset Temperature coefficient: -10 C to 18 C, 28 C to 55 C, .005 % of range per C RTD ranges and accuracy specifications Thermocouple accuracy specifications Thermocouple J K T E R S B L U N Measure or Source -200 to 0 C 1.0 0 to 1200 C 0.7 -200 to 0 C 1.2 0 to 1370 C 0.78 -200 to 0 C 1.0 0 to 400 C 0.8 -200 to 0 C 0.9 0 to 950 C 0.7 -20 to 0 C 2.5 0 to 500 C 1.8 500 to 1750 C 1.4 -20 to 0 C 2.5 0 to 500 C 1.8 500 to 1750 C 1.5 600 to 800 C 2.2 800 to 1000 C 1.8 1000 to 1800 C 1.4 -200 to 0 0 to 900 -200 to 0 0 to 400 -200 to 0 0 to 400 RTD Types, Ranges and Accuracies C C C C C C C C C C C C C C C C C C C 0.85 C 0.7 C C C C C 1.1 0.75 1.5 0.9 Ni 120 Pt 100 - 385 Pt 100 - 3926 Pt 100 - 3916 (JIS) Pt 200 - 385 Pt 500 - 385 Pt 1000 - 385 Resolution RTD -80 C to 260 -200 C to 800 -200 C to 630 -200 C to 630 -200 C to 250 250 C to 630 -200 C to 500 500 C to 630 -200 C to 100 100 C to 630 C C C C C C C C C C Measure Source (4 wire) 0.2 C 0.2 C 0.33 C 0.33 C 0.3 C 0.3 C 0.3 C 0.3 C 0.2 C 0.2 C 0.8 C 0.8 C 0.3 C 0.3 C 0.4 C 0.4 C 0.2 C 0.2 C 0.3 C 0.2 C 0.1 F, 0.1 F C C C C Resolution J, K, T, E, L, N, U 0.1 C, 0.1 F B, R, S 1 C, 1 F Notes Accuracy specifications include 0.2 C cold junction uncertainty. General specifications Fluke. Keeping your world up and running. Fluke Corporation PO Box 9090, Everett, WA USA 98206 Maximum voltage 30 V Temperature Relative humidity Shock Vibration Size Weight -40 C to 71 C (storage), -10 C to 55 C (operating) 95 % (10 to 30 C); 75 % (30 to 40 C); 45 % (40 to 50 C); 35 % (50 to 55 C) 30 g, 11 ms, half-sine shock (or 1 meter drop test) Random, 2 g, 5-500 Hz 7.9 in L x 3.8 in W x 1.9 in D (200 mm L x 96 mm W x 47 mm D) 23 oz (650 g) Battery EMC Warranty Four AA alkaline batteries. Battery life: 25 hours typical EN50082-1:1992 abd EN55022:1994 Class B Three years Fluke Europe B.V. PO Box 1186, 5602 BD Eindhoven, The Netherlands For more information call: In the U.S.A. (800) 443-5853 or Fax (425) 446-5116 In Europe/M-East/Africa (31 40) 2 675 200 or Fax (31 40) 2 675 222 In Canada (800) 36-FLUKE or Fax (905) 890-6866 From other countries +1 (425) 446-5500 or Fax +1 (425) 446-5116 Web access: http://www.fluke.com/ (c)2006 Fluke Corporation. All rights reserved. All copyrights are the property of their respective owners. Printed in U.S.A. 1/2006 2391035 D-EN-N Rev B