PGFS Series 30 Amp Multi-Phase Permanent Series (Splice-In) GFCI INTRODUCTION The LineGardTM 30 Amp Permanent Series is an industrial grade ground fault interrupter device designed and manufactured by North Shore Safety, Ltd., a leader in innovated safety products. The unique design offers the flexibility of splicing in protection of a GFCI anywhere within the length of the circuit run, making it ideal for both new and existing applications. Unlike breaker style GFCI's which have limitations of circuit length from the service panel, the PFGS series can be integrated directly into a circuit or paired in tandem with an approved receptacle and enclosure. Available with an operating voltage of 120/240 VAC dual voltage, 3O 120/208 VAC, 3O 240 VAC (certified to CSA 22.2 only), 3O 208 VAC or 3O 277 VAC (UL 1053 compliant), all units have 18" splicing leads and a 3/4" NPT fitting to allow connection to 3/4" PVC, EMT, burial and flexible conduits. All units are MADE IN THE USA and are listed per UL 943 and CSA 22.2 No.144 FEATURES * Power and fault status indicators * Double insulated user interface * Industrial design for rough service * Chemical and UV resistant enclosure * cULus Listed as a Class A GFCI per UL 943 and CSA 22.2 No. 144 * 30 amp configurations in 120/240 VAC 4-wire, 3O 120/208 VAC 5-wire, 3O 240 VAC 4-wire, 3O 208 VAC 4-wire, 3O 277 VAC 4-wire (UL 1053) * NEMA 4X and 6P wet location rated (indoor / outdoor) * Available in automatic or manual reset configurations1 Specifications Listing Type Rated Supply Voltage cULus Listed Class A UL 943 CSA 22.2 No. 144 120/240 VAC Dual Voltage, 120/208 VAC 3O, 240 VAC 3O (CSA only), 208 VAC 3O, 277 VAC 3O (UL 1053) Rated Current Up to 30 Amps or rating of wiring device and/or cable Horse Power 1HP@120 VAC, 3HP@240 VAC Trip Level Operating Frequency Reset Type1 Phase Response Time Operating Temperature Operating Voltage Range Let-Go Voltage Open Neutral Protection Grounded Neutral Protection 5mA +/-1mA 60 Hz Automatic or Manual Dual voltage and 3 phase 25mS max -35C to 66C 85% to 110% of rated VAC 60% of supply voltage Trips upon loss of neutral Trips if ground and neutral touch at load side 1. Manual configuration should be specified if automatic start-up after power restoration of circuit power creates an unsafe condition. 2. Applicable models only 282 PGFS Series - 30 Amp Multi-Phase Permanent (Splice-In) Series http://airpax.sensata.com/ Confined Space Construction Sites Application Opportunities: (NEC 590.6) Commercial Garages (NEC 511.12) Outdoor Signs (NEC 600.10) Fountains & Water Displays (NEC 680.58) Spa & Hot Tubs (NEC 680.40) Marinas & Boat Yards Electrical wet locations Power generators Agricultural equipment Outdoor electrical equipment Cement cutting equipment Portable electric heaters Submersible pumps Pipeline heaters Automotive garages Industrial part washers Outdoor signage De-icing equipment (roof heaters) OSHA 29 CFR 1926.404 (b)(1)(ii), OSHA 29 CFR 1926.405 (a)(2)(ii)(G) (NEC 555.3) Ground Fault / Equipment Leakage RELATED CODES DECISION TABLES 1 Product Type PGFS - 4 3 0 0 5 6 Mounting Type 5 2 Voltage 3 Ampacity 4 Reset Type C 120/240 VAC split O 3 0 Manual 1 Automatic 30 amps 4 120/208 VAC 3O 1 Panel mount 5 Fault Output Options 0 None 7 240 VAC 3O 8 208 VAC 3O B 277 VAC 3O *Note: 1. Manual configuration should be specified if automatic power-up, after power restoration of circuit power, could create an unsafe condition. Flying Leads (Splice-in) http://airpax.sensata.com/ PGFS Series - 30 Amp Multi-Phase Permanent (Splice-In) Series 283