Panel Mount Datasheet GN Series DC Output SSRs * Current rating 10, 15 and 30 Amps * Output voltage 3-60, 1-50, 1-100 and 1-200 VDC * Transistor and Mosfet Output * Available with or without IP20 touch-safe cover * LED Input Status Indicator * UL Approved, CE Compliant to EN60950-1 * Improved SEMS screw and washer * Redesigned housing with anti-rotation barriers For Generation 3 datasheet click here PRODUCT SELECTION Control Voltage 3-32 VDC 3.5-32 VDC 10 A 15 A 30 A 84134750 84134850 84134860 84134870 AVAILABLE OPTIONS Output Type 7: Transistor 8: MOSFET Series 8413 4 7 Control Thermal Pad Voltage Blank: Not included 0:3.5-32 VDC H: Included 5 Touch Safe Cover 4: Not included (IP00) 7: Included (IP20) U 0 H Rated Voltage & Load Current 5: 3-60 VDC, 10 Amps (with output type 7 only) 5: 1-200 VDC, 10 Amps 6: 1-100 VDC, 15 Amps With output type 8 only 7: 1-50 VDC, 30 Amps Required for valid part number For options only and not required for valid part number OUTPUT SPECIFICATIONS (1) Description Recommended Operating Voltage [Vdc] Absolute Maximum Rating [Vdc] Maximum Off-State Leakage Current @ Rated Voltage [mArms] Maximum Load Current [Adc] (2) Minimum Load Current [mA] Maximum On-State Voltage Drop @ Rated Current [Vdc] Maximum On-State Resistance [RDS-ON] [Ohms] Maximum Surge Current [Adc] (10msec) Thermal Resistance Junction to Case (Rjc) [C/W] Minimum Heat Sink for Rated Current @ 40C [C/W] Maximum Pulse Width Modulation Frequency [Hz] (3) 8413x750 8413x850 8413x860 8413x870 3-48 60 1 10 100 1.4 N/A 15 2 5 1500 1-150 200 0.1 10 0.1 2.1 0.21 50 1.25 1.5 2000 1-72 100 0.1 15 0.1 0.8 0.05 50 2.1 2 2500 1-36 50 0.1 30 0.1 0.8 0.03 72 1.5 2 1200 Do not forget to visit us at: www.crydom.com Copyright (c) 2017 Crydom Inc. Specifications subject to change without notice. Panel Mount Datasheet INPUT SPECIFICATIONS (1) Description Control Voltage Range Maximum Reverse Voltage Minimum Turn-On Voltage Must Turn-Off Voltage Minimum Input Current (for on-state) Maximum Input Current [mA] Nominal Input Impedance [Ohms] Maximum Turn-On Time [sec] Maximum Turn-Off Time [sec] 8413x750 8413x8xx 3-32 VDC -32 VDC 3 VDC 1 VDC 9 mA 14.5 mA 3.5-32 VDC -32 VDC 3.5 VDC (4) 1 VDC 11 mA 15 mA Current Regulated 100 200 75 50 GENERAL SPECIFICATIONS (1) Description Dielectric Strength, Input to Output (50/60Hz) Dielectric Strength, Input/Output to Ground (50/60Hz) Minimum Insulation Resistance (@ 500 VDC) Maximum Capacitance, Input/Output Ambient Operating Temperature Range (5) Ambient Storage Temperature Range Weight (typical) Housing Material Baseplate Material Input Terminal Screw Torque Range (in-lb/Nm) Load Terminal Screw Torque Range (in-lb/Nm) SSR Mounting Screw Torque Range (in-lb/Nm) Humidity per IEC60068-2-78 LED Input Status Indicator MTBF (Mean Time Between Failures) at 40C ambient temperature (6) MTBF (Mean Time Between Failures) at 60C ambient temperature (6) Parameters 3700 Vrms 2500 Vrms 109 Ohms 8 pF -40 to 100 C -40 to 100 C 2.46 oz (70 g) UL94 V-0 Aluminum 13-15 /1.5-1.7 18-20 / 2-2.2 18-20 / 2-2.2 93% non-condensing Green 11,641,553 hours (1,328 years) 7,210,376 hours (823 years) GENERAL NOTES (1) All parameters at 25C unless otherwise specified. (2) Heat sinking required, see derating curves. (3) 8 VDC Minimum control voltage. Resistive loads only. Consider switching losses; at maximum frequency reduce to 75% output current. (4) Increase minimum voltage by 1V for operations from -20 to -40C. (5) Maximum ambient temperature for 8413x750 is 80C, decrease maximun control voltage 1.35V/C above 80C ambient temperature. (6) All parameters at 50% power rating and 100% duty cycle (contact Crydom tech support for detailed report). For additional information or specific questions, contact Crydom Technical Support. Do not forget to visit us at: www.crydom.com Copyright (c) 2017 Crydom Inc. Specifications subject to change without notice. Panel Mount Datasheet WIRING DIAGRAM * Inductive loads must be diode suppresed. + + V - Load - * Load + * Recommended Wire Sizes V + Wire Size (Solid / Stranded) Terminals 24 AWG (0.2 mm2) / 0.2 [minimum] Input 1 +2 OUTPUT 1 4 4 +3 INPUT 2 x 12 AWG (3.3 +2 OUTPUT S O L I D S TAT E R E L AY S O L I D S TAT E R E L AY Output +3 INPUT 10 [44.5] / 3.3 [maximum] 90 [400] 20 AWG (0.5 mm2) / 0.518 [minimum] 30 [133] 2 x 10 AWG (5.3 mm2) / 5.3 110 [490] 2 x 8 AWG (8.4 mm2) / 8.4 [maximum] 90 [400] 2 +DC Control Circuit OUTPUT +DC 3 Trigger Circuit 1 Current Limiter -DC Input Current (mA) EQUIVALENT CIRCUIT BLOCK DIAGRAMS INPUT mm2) + V - + V - -DC 4 Wire Pull-Out Strength (lb)[N] Input Current vs Input Voltage Standard Regulated DC Input 14 12 10 8 6 4 2 0 0 5 10 15 20 DC Input Voltage 25 30 35 MECHANICAL SPECIFICATIONS (1) Tolerances: 0.02 in / 0.5 mm All dimensions are in: inches [millimeters] Screw Termination, IP00 1.1 [27.9] 0.49 [12.4] 1.88 [47.6] Screw Termination, IP20 0.89 [22.6] Mounting Hole/Slot 0.19 [4.9] DIA. 1.7 [43.2] 1.10 [27.9] 0.49 [12.4] 2.25 [57.3] 1.88 [47.6] 1.7 [43.2] 1.0 [25.4] 1.75 [44.5] Do not forget to visit us at: www.crydom.com Copyright (c) 2017 Crydom Inc. Specifications subject to change without notice. Mounting Hole/Slot 0.19 [4.9] DIA. 2.25 [57.3] 2.32 [58.8] 1.0 [25.4] 1.75 [44.5] 1.22 [30.9] Panel Mount Datasheet THERMAL DERATE INFORMATION (i) SSR metal base plate acting as heat sink, it must be exposed to free ambient air. 8413x850 8413x750 5C/W 2C/W No Heat Sink (*) Load Current (Amps) Load Current (Amps) 8 6 4 2 0 20 30 40 50 60 70 Ambient Temperature (C) 6 4 2 0 80 3C/W 20 30 40 50 60 70 80 Ambient Temperature (C) 90 100 8413x870 2C/W 5C/W 15 3C/W 5C/W No Heat Sink (*) 30 Load Current (Amps) Load Current (Amps) 5C/W 8 8413x860 2C/W 10 5 0 3C/W 10 10 20 30 40 50 60 70 80 Ambient Temperature (C) 90 25 20 15 10 5 0 100 20 30 40 50 60 70 80 Ambient Temperature (C) 90 100 SURGE CURRENT INFORMATION 8413x750 8413x850 70 Surge Current (Amp) Surge Current (Amp) 20 15 10 5 0 0.1 1 10 100 1000 Do not forget to visit us at: www.crydom.com 60 50 40 30 20 10 0 0.1 Copyright (c) 2017 Crydom Inc. Specifications subject to change without notice. 1 10 100 1000 Panel Mount Datasheet Surge Duration (msec) 8413x870 8413x860 80 150 70 Surge Current (Amp) Surge Current (Amp) Surge Duration (msec) 60 50 40 30 20 10 0 0.1 1 10 Surge Duration (msec) Period Duty Factor 10% Pulse Width 1000 100 75 50 25 0 0.1 For Pulse Width Modulation applications select the curve according duty factor and pulse duration as following. Duty Factor = Duty Factor 20% Duty Factor 50% 100 125 Pulse Width Period x100 (%) (i) for Single Surge Pulse Tc=40C ;Tj 175C (ii) for Repetitive Surge Pulse Tc=40C ;Tj 130C AGENCY APPROVALS EN60950-1: Meets the requirements of sections1.5: 1,7: 2.9: 2.10.5.3: 4.2: 4.5: 4.7: E46203 Do not forget to visit us at: www.crydom.com Copyright (c) 2017 Crydom Inc. Specifications subject to change without notice. 1 10 Surge Duration (msec) 100 1000 Panel Mount Datasheet ACCESSORIES Recommended Accessories Cover Hardware Kit Heat Sink Part No. Thermal Resistance Lug Terminal Thermal Pad [C/W] KS101 HK1 HS501DR 5.0 TRM1 HSP-1 HK4 HS301 / HS301DR 3.0 TRM6 HSP-2 HS251 2.5 HS201 / HS201DR 2.0 HS202 / HS202DR 2.0 HS172 1.7 HS151 / HS151DR 1.5 HS122 / HS122DR 1.2 HS103 / HS103DR 1.0 HS101 1.0 HS073 0.7 HS072 0.7 HS053 0.5 HS033 0.36 HS023 0.25 Rev. 092816 Do not forget to visit us at: www.crydom.com Copyright (c) 2017 Crydom Inc. Specifications subject to change without notice. Panel Mount Datasheet DANGER / PELIGRO / DANGER /GEFAHR / PERICOLO / HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH. * Disconnect all power before installing or working with this equipment. * Verify all connections and replace all covers before turning on power. Failure to follow these instructions will result in death or serious injury. RIESGO DE DESCARGA ELECTRICA O EXPLOSION. * Desconectar todos los suministros de energia a este equipo antes de trabajar con este equipo. * Verificar todas las conexiones y colocar todas las tapas antes de energizer el equipo. El incumplimiento de estas instrucciones puede provocar la muerte o lesiones serias. RISQUE DE DESCHARGE ELECTRIQUE OU EXPLOSION * Eteindre toutes les sources d'energie de cet appareil avant de travailler dessus de cet appareil * Verifier tous connections, et remettre tous couverts en olace avant de mettre sous De non-suivi de ces instructions provoquera la mort ou des lesions serieuses serieuses. GEFAHR EINES ELEKTRISCHE N SCHLAGES ODER EINER EXPLOSION. * Stellen Sie jeglichen Strom ab, der dieses Gerat versorgt, bevor Sie an dem Gerat Arbeiten durchfuhren * Vor dem Drehen auf Energie alle Anschlusse uberprufen und alle Abdeckungen ersetzen. Unterlassung dieser Anweisungen konnen zum Tode oder zu schweren Verletzungen fuhren. RISCHIO DI SCOSSA ELETTRICA O DELL'ESPLOSI ONE. * Spenga tutta l'alimentazion e che fornisce questa apparecchiatu ra prima del lavorare a questa apparecchiatu ra * * Verificare tutti i collegamenti e sostituire tutte le coperture prima della rotazione sull'alimentazi one L'omissione di seguire queste istruz ioni provochera la morte o di lesioni serie WARNING / AVERTISSEMENT / WARNUNG /ADVERTENCIA / AVVERTENZA / RISK OF MATERIAL DAMAGE AND HOT ENCLOSURE RISQUE DE DOMMAGE MATERIEL ET DE SURCHAUFFE DU BOITIER GEFAHR VON MATERIALSCHADEN UND GEHAUSEERHITZUNG * The product's side panels may be hot, allow the product to cool before touching. * Follow proper mounting instructions including torque values. * Do not allow liquids or foreign objects to enter this product. * Les panneaux lateraux du produit peuvent etre chauds. Laisser le produit refroidir avant de le toucher. * Respecter les consignes de montage, et notamment les couples de serrage. * Ne pas laisser penetrer de liquide ni de corps etrangers a l'interieur du produit. * Die Seitenwande konnen hei sein. Lassen Sie das Produkt abkuhlen, bevor Sie es beruhren. * Beachten Sie die Montageanweisungen, * Fuhren Sie keine Flussigkeiten oder Fremdkorper in das Produkt ein. Le non-respect de cette directive peut entrainer, Failure to follow these instructions can result in des lesions corporelles graves ou des serious injury, or equipment damage. dommages materiels. Die Nichtbeachtung dieser Anweisung kann Korperverletzung oder Materialschaden zur Folge haben. RIESGO DE DANOS MATERIALES Y DE SOBRECALENTAMIENTO DE LA UNIDAD RISCHIO DI DANNI MATERIALI E D'INVOLUCRO CALDO * Los paneles laterales del producto pueden estar calientes. Esperar que el producto se enfrie antes de tocarlo. * Respetar las instrucciones de montaje, y en particular los pares de apretado. * No dejar que penetren liquidos o cuerpos extranos en el producto. * I pannelli laterali dell'apparecchio possono scottare; lasciar quindi raffreddare il prodotto prima di toccarlo. * Seguire le istruzioni di montaggio corrette. * Non far entrare liquidi o oggetti estranei in questo apparecchio. Si no se respetan estas precauciones pueden producirse graves lesiones, danos materiales. La mancata osservanza di questa precauzione puo causare gravi rischi per l'incolumita personale o danni alle apparecchiature. Do not forget to visit us at: www.crydom.com Copyright (c) 2017 Crydom Inc. Specifications subject to change without notice. * * * Panel Mount Datasheet ANNEX - ENVIROMENTAL INFORMATION The environmental information disclosed in this annex including the EIP Pollution logo are in compliance with People's Republic of China Electronic Industry Standard SJ/T11364 - 2006, Marking for Control of Pollution Caused by Electronic Information Products. Part Name Toxic or hazardous Substance and Elements Lead (Pb) Mercury (Hg) Cadmium (Cd) Hexavalent Chromium (Cr (VI)) Polybrominated biphenyls (PBB) Polybrominated diphenyl ethers (PBDE) Semiconductor die Solder - SJ/T11364 - 2006, (Pb) (Hg) (Cd) (Cr (VI)) 50 Do not forget to visit us at: www.crydom.com Copyright (c) 2017 Crydom Inc. Specifications subject to change without notice. (PBB) (PBDE)