ACDC
Specification
400 Watts
•400 W Continuous, 600 W Peak
•IT and Medical Approvals
•80 V 275 VAC Operation
•Low Noise Fan
•Screw Terminals
•5 V Standby, AC OK and Remote On/Off
•3 Year Warranty
FCM Series
Input
Input Voltage • 80-275 VAC, derate output power
<90 VAC (see derating curve)
Input Frequency • 47-63 Hz
Input Current • 4.1 A at 115 VAC typical
2.1 A at 230 VAC with 400 W load
Inrush Current • 60 A max at 264 VAC, cold start 25 °C
Power Factor • >0.9
Earth Leakage Current • 260 µA max, 264 VAC, 60 Hz
Input Protection • F10 A / 250 V internal fuse in line
and neutral
Output
Output Voltage • 12-48 VDC (see tables)
Output Voltage Trim • ±10% V1
Initial Set Accuracy • ±1% V1, ±5% V2
Minimum Load • No minimum load required
Start Up Delay • 1 s typical
Start Up Rise Time • 50 ms
Hold Up Time • 20 ms minimum
Line Regulation • ±0.5% maximum
Load Regulation • ±1% V1, ±5% V2
Transient Response • 4% max. deviation, recovery to
within 1% in 500 µs for a 50-75-50%
load change
Ripple & Noise • 1% pk-pk, 20 MHz bandwidth
Overvoltage Protection • 115-140% Vnom, recycle input to reset
Overtemperature • Auto reset
Protection
Overload Protection • 150-165%, V1 only
Short Circuit Protection • Continuous, approximately constant
current
Temperature • 0.05% / °C
Coefficient
Remote On/Off • Uncommitted isolated optocoupler diode,
powered diode inhibits V1 & Fan
xppower.com
General
Efficiency • 85% typical
Isolation • 4000 VAC input to output, 2 x MOPP,
1500 VAC input to ground, 1 x MOPP,
500 VAC output to ground
Switching Frequency • PFC 70 kHz, main converter 65 kHz typical
Power Density • 8.6 W/in3
Signals • AC OK, remote on/off, 5 V standby
MTBF • 236 kHrs to MIL-HDBK-217F at 25 °C, GB
Environmental
Operating Temperature • -10 °C to +70 °C, derate linearly
from +50 °C at 2.5% / °C to 50%
load at +70 °C
Cooling • Forced cooled with integral fan
Operating Humidity • 95% RH, non-condensing
Storage Temperature • -40 °C to +85 °C
Operating Altitude • 3000 m
Shock • 30 g pk, half sine, 6 axes
Vibration • 2 g rms, 5 Hz to 500 kHz, 3 axes
EMC & Safety
Emissions • EN55011/22 level B conducted
EN55011/22 level A radiated
Harmonic Currents • EN61000-3-2, class A
EN61000-3-2, class C for loads ≥50%
Voltage Flicker • EN61000-3-3
Radiated Immunity • EN61000-4-3, level 3 Perf Criteria A
EFT/Burst • EN61000-4-4, level 3 Perf Criteria A
Surge • EN61000-4-5, installation class 3,
Perf Criteria A
Conducted Immunity • EN61000-4-6, level 3, Perf Criteria A
Dips & Interruptions • EN61000-4-11, 30% 10 ms, 60% 100 ms,
100% 5000 ms, Perf Criteria A, B, B,
EN60601-1-2, 30% 500 ms, 60% 100 ms,
100% 10 ms, 100% 5000 ms, Perf Criteria
A, A, A, B - 230 VAC. Consult longform
datasheet for 115 V operation
Safety Approvals • IEC60950-1 CB report, UL60950-1, TUV,
EN60950-1, IEC60601-1 CB report, CSA
22.2 No.60601-1, ANSI/AAMI ES60601-1,
TUV60601-1, including risk management