https://www.phoenixcontact.com/us/products/2308098 Universal current transducer - MCR-SL-CUC-600-I - 2308098 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) Universal current transducer, for measuring DC, AC, and distorted currents, 0 ... 600 A input current, 4 ... 20 mA output The MCR-SL-CUC-100-I is illustrated Product Features Variable mounting on DIN rail and mounting plate Simple connection technology thanks to COMBICON plug-in connection terminal blocks Compact dimensions also enable distributed use 3-way isolation Universal current measurement, no shunt required Key commercial data Packing unit 1 pc Weight per Piece (excluding packing) 297.6 GRM Custom tariff number 90303310 Country of origin Japan Technical data Dimensions Width 90 mm Height 33.8 mm Depth 85 mm Ambient conditions Ambient temperature (operation) -40 C ... 65 C Ambient temperature (storage/transport) -40 C ... 85 C Degree of protection IP20 Input data 09/03/2014 Page 1 / 4 https://www.phoenixcontact.com/us/products/2308098 Universal current transducer - MCR-SL-CUC-600-I - 2308098 Technical data Input data Input current range 0 A ... 600 A Overload capacity 3 x IIN Frequency measuring range 20 Hz ... 6000 Hz (0 Hz) Connection method Cable design: 32 mm diameter Output data Output name Current output Current output signal 4 mA ... 20 mA Max. output current < 25 mA Load/output load current output < 300 Switching output Output name No switching output Power supply Nominal supply voltage 24 V DC Supply voltage range 20 V DC ... 30 V DC Max. current consumption (30 + IOUT) mA Connection data Conductor cross section solid min. 0.25 mm Conductor cross section solid max. 2.5 mm Conductor cross section AWG/kcmil min. 24 Conductor cross section AWG/kcmil max 12 Conductor cross section stranded min. 0.2 mm Conductor cross section stranded max. 2.5 mm Stripping length 10 mm General Maximum transmission error < 1 % (of final value) Temperature coefficient, typical 0.02 %/K (0 ... 60C) 0.04 %/K (-40 ... 65C) Linearity error < 1 % (From the range end value) Step response (10-90%) 150 ms Surge voltage category III Pollution degree 2 Rated insulation voltage 300 V AC Test voltage input/output 3.5 kV (50 Hz, 1 min.) Test voltage input/power supply 3.5 kV (50 Hz, 1 min.) Noise emission EN 61000-6-4 09/03/2014 Page 2 / 4 https://www.phoenixcontact.com/us/products/2308098 Universal current transducer - MCR-SL-CUC-600-I - 2308098 Technical data General Noise immunity EN 61000-6-2 Color green Housing material Frianyl B63 V0 GV30 Conformance CE-compliant Classifications eCl@ss eCl@ss 4.0 27200303 eCl@ss 4.1 27200303 eCl@ss 5.0 27200303 eCl@ss 5.1 27210902 eCl@ss 6.0 27210902 eCl@ss 7.0 27210902 eCl@ss 8.0 27210902 ETIM ETIM 3.0 EC002475 ETIM 4.0 EC002048 ETIM 5.0 EC002475 UNSPSC UNSPSC 6.01 30211506 UNSPSC 7.0901 39121008 UNSPSC 11 39121008 UNSPSC 12.01 39121008 UNSPSC 13.2 39121008 Drawings 09/03/2014 Page 3 / 4 https://www.phoenixcontact.com/us/products/2308098 Universal current transducer - MCR-SL-CUC-600-I - 2308098 Dimensioned drawing Circuit diagram 90 33,8 O32 ADC C 1.4 GND 1.3 NC 1.2 OUT I 1.1 +24 V DC DAC I 70 IN Schematic diagram A B Phoenix Contact 2014 (c) - all rights reserved http://www.phoenixcontact.com 09/03/2014 Page 4 / 4