APT40DS04HJ ISOTOP(R) Schottky Diode Full Bridge Power Module VRRM = 45V IF = 40A @ Tc = 80C Application Switch mode power supplies rectifier Induction heating Welding equipment Features + ~ ~ - Ultra fast recovery times Soft recovery characteristics High current Very low stray inductance High level of integration ISOTOP(R) Package (SOT-227) Benefits Outstanding performance at high frequency operation Low losses Low noise switching Direct mounting to heatsink (isolated package) Low junction to case thermal resistance RoHS Compliant Symbol VR VRRM IFAV IFSM Parameter Maximum DC reverse Voltage Maximum Peak Repetitive Reverse Voltage Rectangular, d = 0.5 Non-Repetitive Forward Surge Current t = 10ms TC = 80C TJ = 45C Max ratings Unit 45 V 40 450 A These Devices are sensitive to Electrostatic Discharge. Proper Handling Procedures Should Be Followed. See application note APT0502 on www.microsemi.com www.microsemi.com 1-4 APT40DS04HJ - Rev 1 October, 2012 Absolute maximum ratings APT40DS04HJ All ratings @ Tj = 25C unless otherwise specified Electrical Characteristics Symbol Characteristic Test Conditions IR Reverse Current VR = 45V VF Forward Voltage IF = 40A Min Tj = 25C Tj = 125C Tj = 25C Tj = 125C Typ Max 20 200 0.58 0.48 Unit mA V Thermal and package characteristics Symbol RthJC RthJA VISOL TJ,TSTG TL Torque Wt Characteristic Junction to Case Thermal resistance Junction to Ambient Min RMS Isolation Voltage, any terminal to case t =1 min, 50/60Hz 2500 -55 Storage Temperature Range Max Lead Temp for Soldering:0.063" from case for 10 sec Mounting torque (Mounting = 8-32 or 4mm Machine and terminals = 4mm Machine) Package Weight Typ Max 1.1 20 Unit C/W V 150 300 1.5 29.2 C N.m g SOT-227 (ISOTOP(R)) Package Outline 11.8 (.463) 12.2 (.480) 31.5 (1.240) 31.7 (1.248) 7.8 (.307) 8.2 (.322) r = 4.0 (.157) (2 places) W=4.1 (.161) W=4.3 (.169) H=4.8 (.187) H=4.9 (.193) (4 places) 4.0 (.157) 4.2 (.165) (2 places) 3.3 (.129) 3.6 (.143) 8.9 (.350) 9.6 (.378) Hex Nut M4 (4 places) 0.75 (.030) 0.85 (.033) 25.2 (0.992) 25.4 (1.000) 3.30 (.130) 12.6 (.496) 4.57 (.180) 12.8 (.504) 1.95 (.077) 2.14 (.084) 14.9 (.587) 15.1 (.594) Dimensions in Millimeters and (Inches) 38.0 (1.496) 38.2 (1.504) www.microsemi.com 2-4 APT40DS04HJ - Rev 1 October, 2012 30.1 (1.185) 30.3 (1.193) APT40DS04HJ Typical Performance Curve Forward Characteristic 80 60 IF (A) TJ=125C 40 TJ=25C 20 0 0.0 0.2 0.4 0.6 0.8 1.0 VF (V) maximum Effective Transient Thermal Impedance, Junction to Case vs Pulse Duration Thermal Impedance (C/W) 1.2 1 0.8 0.9 0.7 0.6 0.5 0.4 0.3 0.2 0.1 Single Pulse 0.05 0 0.00001 0.0001 0.001 0.01 0.1 1 10 Rectangular Pulse Duration in Seconds www.microsemi.com 3-4 APT40DS04HJ - Rev 1 October, 2012 ISOTOP(R) is a registered trademark of ST Microelectronics NV APT40DS04HJ DISCLAIMER The information contained in the document (unless it is publicly available on the Web without access restrictions) is PROPRIETARY AND CONFIDENTIAL information of Microsemi and cannot be copied, published, uploaded, posted, transmitted, distributed or disclosed or used without the express duly signed written consent of Microsemi. If the recipient of this document has entered into a disclosure agreement with Microsemi, then the terms of such Agreement will also apply. This document and the information contained herein may not be modified, by any person other than authorized personnel of Microsemi. No license under any patent, copyright, trade secret or other intellectual property right is granted to or conferred upon you by disclosure or delivery of the information, either expressly, by implication, inducement, estoppels or otherwise. Any license under such intellectual property rights must be approved by Microsemi in writing signed by an officer of Microsemi. Microsemi reserves the right to change the configuration, functionality and performance of its products at anytime without any notice. This product has been subject to limited testing and should not be used in conjunction with lifesupport or other mission-critical equipment or applications. Microsemi assumes no liability whatsoever, and Microsemi disclaims any express or implied warranty, relating to sale and/or use of Microsemi products including liability or warranties relating to fitness for a particular purpose, merchantability, or infringement of any patent, copyright or other intellectual property right. Any performance specifications believed to be reliable but are not verified and customer or user must conduct and complete all performance and other testing of this product as well as any user or customers final application. User or customer shall not rely on any data and performance specifications or parameters provided by Microsemi. It is the customer's and user's responsibility to independently determine suitability of any Microsemi product and to test and verify the same. The information contained herein is provided "AS IS, WHERE IS" and with all faults, and the entire risk associated with such information is entirely with the User. Microsemi specifically disclaims any liability of any kind including for consequential, incidental and punitive damages as well as lost profit. The product is subject to other terms and conditions which can be located on the web at http://www.microsemi.com/legal/tnc.asp Life Support Application Seller's Products are not designed, intended, or authorized for use as components in systems intended for space, aviation, surgical implant into the body, in other applications intended to support or sustain life, or for any other application in which the failure of the Seller's Product could create a situation where personal injury, death or property damage or loss may occur (collectively "Life Support Applications"). Buyer agrees not to use Products in any Life Support Applications and to the extent it does it shall conduct extensive testing of the Product in such applications and further agrees to indemnify and hold Seller, and its officers, employees, subsidiaries, affiliates, agents, sales representatives and distributors harmless against all claims, costs, damages and expenses, and attorneys' fees and costs arising, directly or directly, out of any claims of personal injury, death, damage or otherwise associated with the use of the goods in Life Support Applications, even if such claim includes allegations that Seller was negligent regarding the design or manufacture of the goods. www.microsemi.com 4-4 APT40DS04HJ - Rev 1 October, 2012 Buyer must notify Seller in writing before using Seller's Products in Life Support Applications. Seller will study with Buyer alternative solutions to meet Buyer application specification based on Sellers sales conditions applicable for the new proposed specific part.