Keysight U8030 Series
Triple-Output DC Power Supplies
Data Sheet
Higher Power. Better Reliability. Unrivalled Performance.
Keysight Technologies, Inc. extends its family of basic DC power supplies to include a one of a kind
power supply that offers up to 375 W power at three outputs. Equipped with output sequencing
capability, it allows you to generate output sequences even with minimal programming skills.
Each power supply is also built with excellent load regulation and clean output noise for continued
stability. With these and many other features, you get a solid and reliable triple-output power supply
at an unsurpassed performance.
The U8030 series offers two models — the U8031A and U8032A, each with different voltage and
current ratings to cater to your needs. Both models are well-regulated compact bench-tops with
total output of 375 W, making it an ideal power source alternative in electronics manufacturing,
research and development as well as education sector.
Generate power supply output sequences —
No extensive programming skills necessary
The output sequencing capability is carefully thought out for your convenience and ease when
operating. Designed to perform automation function, our U8030 series is well-suited even for those
with minimal programming skills. With easy-to-use knob and intuitive keypads, you can now set
your desired output sequences for margin test, burn-in test and other general purpose tasks in an
industrial setting.
Key Features
Provides total power of 375 W for three outputs
Output sequencing capability
Excellent load and line regulation (CV: < 0.01% + 2 mV; CC: < 0.02% + 2 mA) ensures stable out-
put
Provides clean output with ≤ 1 mVrms (0.5 mVrms typical) noise
Fast < 50 µs transient response for stable testing
Dual display shows both voltage and current reading
Over-voltage and over-current protection
Security features: keypad lock and physical lock mechanism
2
Introduction
3
Unrivalled performance—
with low output noise and
excellent load regulation
The U8030 series provides excellent
load and line regulation (CV: < 0.01%
+ 2 mV; CC: <0.02% + 2 mA) to
ensure stable output even when load
changes. This is crucial especially
when dealing with noise-sensitive
circuits that demand clean power. At
a wide bandwidth of 20 Hz to 20 MHz,
our bench power supplies continue
to provide clean output at the lowest
Vrms ≤ 1 mVrms (0.5 mVrms typical),
leaving your signals uncontaminated
and ensuring minimal interference to
your Device-Under-Test (DUT).
Added safety features—
with OVP, OCP and
physical lock mechanism
Safety is an important consideration
when dealing with power. Users may
not only want to protect themselves
from exposure to current, but also
the additional costs incurred to their
investment (DUT). Our U8030 series
power supplies are integrated with
an array of security features such as
over-voltage (OVP) and over-current
(OCP) protection to mitigate these
risks.
Additionally, security features such
as keypad locking capability prevents
accidental front panel usage while
physical lock mechanism which is
strategically located at the rear of
the unit provides secure instrument
storage.
Differentiated features—
allowing you to work better
Both models of the U8030 series
come with a set of features to suit
your needs while remaining easy to
use. The LCD screen displays both
voltage and current readings in a one-
view panel while the all ON/OFF but-
ton allows multiple outputs to be con-
trolled simultaneously. Additionally,
the auto-track feature simplifies setup
between output 1 and output 2. With
these, you get a solid bench power
supply plus a set of convenient and
easy to use features.
Figure 1. Output sequencing made easy with
intuitive keypads
Figure 2. Backlight on/off feature with dual
reading (voltage and current) on an LCD display
Figure 3. Simplifies Output 1 and Output 2
setup with tracking feature
4
Front Panel Description
Output sequencing function:
Generates output sequences
without a PC
LCD display:
Allows dual reading (voltage
and current) in one display
Channel control:
Allows channels to be controlled
individually/simultaneously (ON/OFF)
Tracking:
Auto-tracking between output 1 and
output 2 with single control
Essential security features:
Over-voltage protection (OVP)/
Over-current protection (OCP),
keypad lock and physical lock
mechanism
Backlight On/Off:
Switches backlight off
when not needed
Rotary knob:
Allows quick and easy volt-
age and current setting
Keypad lock/unlock:
Locks front panel to prevent
accidental change
Physical lock mechanism as illustrated
Figure 4. The U8032A as illustrated
5
Key Specications
Electrical Specications
Table 1.1 Electrical specications 1
Parameter
U8031A U8032A
Total power output (W) 0 – 375 W
Voltage output (V)
Output Channel 1 & 2 (@ 0 to 40 °C)
0 to 30 V 0 to 60 V
Current output (A)
Output Channel 1 & 2 (@ 0 to 40 °C)
0 to 6 A 0 to 3 A
Number of outputs Three isolated outputs
Two variable: CV and CC operation
One fixed: CV operation only
5 V fixed output 2
Output Channel 3
Voltage/Current output: 5 V, 3A
Output accuracy: ≤ 5% or (5 V ± 0.25 V)
Vrms: < 2 mVrms, or Vpp: < 50 mVpp
Load and line regulation: ≤ 5 mV
Overload condition: 3 A + 20% (typical)
Line & load regulation
(for variable output)
CV: < 0.01% + 2 mV
CC: < 0.02% + 2 mA
Ripple & noise
Based on calculation at temp 18 - 28 °C and
bandwidth at 20 Hz to 20 MHz
CV: ≤1 mVrms, 0.5 mVrms (typical)
or ≤ 10 mVpp, 5 mVpp (typical)
CC: ≤ 1 mArms
Load transient response time
Within 15 mV from full load to half load
and from half load to full load
< 50 us
Stability (output drift)
Following a 30-minute warm-up, with the output in the ON state
according to the operating mode (CC with load or CV), and with a
change in the output over 8 hours under constant load, line, and ambient
temperature.
Voltage: < 0.02%
Current: < 0.1%
Programming accuracy (23 °C ± 5 °C) CV: ≤ 0.25% + 15 mV
CC: ≤ 0.30% + 15 mA
Meter readback accuracy (23 °C ± 5 °C) CV: ≤ 0.25% + 10 mV
CC: ≤ 0.25% + 10 mA
Programming/meter resolution Voltage: 10 mV (4 digits)
Current: 10 mA (3 digits)
Maximum output float voltage ±240 Vdc
1. The specifications stated are based on a 1 hour warm-up period.
2. The specifications referenced in this row are for Output Channel 3 (5 V fixed output). All other specifications listed in this table are intended for
Output Channel 1 and 2, unless otherwise stated. .
6
Physical characteristics
Table 1.2 Physical characteristics
Parameter
U8031A/U8032A
Display LCD with amber backlight
Rotary knob for reading adjustment Yes
Size 4U, half rack
Dimensions (H x W x D) 179.0 x 212.3 x 379.0 mm
Weight 8.2 kg
Supplemental characteristics
Table 1.3 Supplemental characteristics
Parameter
U8031A U8032A
Temperature coefficient (for 12 months)
±(% of output + offset)
Output
CV: (0.01% + 1 mV)/°C
CC: (0.01% + 1 mA)/°C
OVP, OCP
CV: < 0.05%/°C
CC: < 0.05%/°C
Output voltage overshoot
During turn-on or turn-off of AC power, if output control is
set less than 1 V
< 1 V
Voltage programming speed to within 1 % of total excursion
Up Full load
No load
Down Full load
No load
30 V 60 V
80 ms
80 ms
30 ms
150 ms
200 ms
100 ms
30 ms
300 ms
Over temperature protection Yes
Last memory setting enabled Yes
Three memory storage locations for voltage and current settings Yes
Erasing non-volatile memory Yes, erasable through front panel
Rack mount capability Yes, front panel and rear have rack-mountable support
7
AC power input specications
Table 1.4 AC power input specications
Parameter
U8031A/U8032A
Input power option (selectable) 100 Vac ± 10%, 47 to 63 Hz
115 Vac ± 10%, 47 to 63 Hz
230 Vac ± 10%, 47 to 63 Hz
Maximum input power 600 VA
Fuse External, located at the rear panel
Environmental specications
Table 1.5 Environmental specications
Parameter
U8031A/U8032A
Operating temperature 0 to 40 °C
Storage temperature –40 to 70 °C
Humidity 15% RH (relative humidity) to 85% RH at 40 °C (non condensing)
Altitude Up to 2000 m
Fan acoustic noise No load: follow Keysight Class CO, 45 dB sound pressure
and 50 dB sound power
Full load: follow Keysight Class GP, 55 dB sound pressure
and 60 dB sound power
Environment of use Installation category II
Pollution Degree 2
Connection specications
Table 1.6 Connection specications
Parameter
U8031A/U8032A
Output connections +Out, –Out, and chassis ground on the front panel.
(Either positive or negative output terminal may be grounded or can be
operated floating at up to a maximum of 240 V off ground. Total output
voltage to ground must not exceed 240 Vdc)
Binding posts Output binding post located horizontally and side by side
I/O connections N/A
AC input 3 pins standard IEC AC power connector with fuse and line
selection at the rear
8
Protection features
Table 1.7 Protection features
Parameter
U8031A U8032A
Overvoltage protection accuracy ± (% of output + offset) < 0.5% +0.5 V
Overvoltage protection programmable range 0.1 to 33.0 V 0.1 to 66.0 V
Overvoltage protection response time < 10 ms
Overcurrent protection accuracy ± (% of output + offset) < 0.5% + 0.5 A
Overcurrent protection programmable range 0.1 to 6.6 A 0.1 to 3.3 A
Overcurrent protection response time < 10 ms
Ordering Information
Included documentation:
U8030 Series Product Reference CD-ROM
Additional documentation:
U8031A-ACF Japanese language user guide, printed
U8031A-ABA English language user guide, printed
U8032A-ACF Japanese language user guide, printed
U8032A-ABA English language user guide, printed
Calibration document:
U8031A-UK6 Commercial calibration with test result data
U8032A-UK6 Commercial calibration with test result data
Other Options:
E3600A-100 Test lead kit
Option 1CM Rack-mount kit
Rack-mount kits:
To rack-mount a single instrument:
Adapter kit (P/N 5063-9245)
For more information on Keysight
Technologies’ products, applications or
services, please contact your local Keysight
office. The complete list is available at:
www.keysight.com/find/contactus
Americas
Canada (877) 894 4414
Brazil 55 11 3351 7010
Mexico 001 800 254 2440
United States (800) 829 4444
Asia Pacic
Australia 1 800 629 485
China 800 810 0189
Hong Kong 800 938 693
India 1 800 112 929
Japan 0120 (421) 345
Korea 080 769 0800
Malaysia 1 800 888 848
Singapore 1 800 375 8100
Taiwan 0800 047 866
Other AP Countries (65) 6375 8100
Europe & Middle East
Austria 0800 001122
Belgium 0800 58580
Finland 0800 523252
France 0805 980333
Germany 0800 6270999
Ireland 1800 832700
Israel 1 809 343051
Italy 800 599100
Luxembourg +32 800 58580
Netherlands 0800 0233200
Russia 8800 5009286
Spain 0800 000154
Sweden 0200 882255
Switzerland 0800 805353
Opt. 1 (DE)
Opt. 2 (FR)
Opt. 3 (IT)
United Kingdom 0800 0260637
For other unlisted countries:
www.keysight.com/find/contactus
(BP-07-01-14)
This information is subject to change without notice.
© Keysight Technologies, 2012 – 2014
Published in USA, August 2, 2014
5990-9321EN
www.keysight.com
09 | Keysight | U8030 Series Triple-Output DC Power Supplies – Data Sheet
myKeysight
www.keysight.com/find/mykeysight
A personalized view into the information most relevant to you.
www.axiestandard.org
AdvancedTCA® Extensions for Instrumentation and Test (AXIe) is an
open standard that extends the AdvancedTCA for general purpose and
semiconductor test. Keysight is a founding member of the AXIe consortium.
www.lxistandard.org
LAN eXtensions for Instruments puts the power of Ethernet and the
Web inside your test systems. Keysight is a founding member of the LXI
consortium.
www.pxisa.org
PCI eXtensions for Instrumentation (PXI) modular instrumentation delivers a
rugged, PC-based high-performance measurement and automation system.
www.keysight.com/quality
Keysight Technologies, Inc.
DEKRA Certified ISO 9001:2008
Quality Management System
Keysight Channel Partners
www.keysight.com/find/channelpartners
Get the best of both worlds: Keysight’s measurement expertise and product
breadth, combined with channel partner convenience.
www.keysight.com/find/U8030